Military Engineer Services-MES has published Repair / Maintenance Of Electrical Installations And Transformers , Feeder Pillar Boxes , Apfc Panels , Lt Overhead Lines , Ug Cable Incl Allied Works At Cantt Area And 119Ta Bn Under Ge Shillong. Submission Date for this Tender is 24-03-2021. Electrical Maintenance Tenders in SHILLONG Meghalaya. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 17-Mar-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-03-2021 |
Name of Work: REPAIR / MAINTENANCE OF ELECTRICAL INSTALLATIONS AND TRANSFORMERS, FEEDER PILLAR BOXES, APFC PANELS, LT OVERHEAD LINES, UG CABLE INCL ALLIED WORKS AT CANTT AREA AND 119TA BN UNDER GE SHILLONG. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Filtration and dehydration of transformer oil and removing sludge by continuous circulation through filtration plant with strip heater and improvement of dielectric strength to minimum 40 KV at 4mm gap of electrode for 63 KVA to 500 KVA capacities of transformer including refilling of filtered transformer oil complete all as specified and as directed by Engineer-in-Charge. | 10000 | LITRE | |
2 | 2 | M&L for Topping up / replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade, including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap transformer for various capacities of transformer complete all as directed. Make of transformer oil : Gulf /Castrol /HP /IOC/BP. \nNotes : For Ser Item No 1 & 2\n(a) New transformer oil (ISI marked) shall be supplied by the contractor in sealed container with original manufacturing test certificate.\n(b) Filtration/dehydration of transformer oil shall be carried out at the location where transformer is installed and necessary tools & instruments shall be brought at working site by the contractor.\n(c) During the process of filtration, transformer will be on load condition.\n(d) The old unserviceable transformer oil shall be sold to the contractor under schedule of credit.\n(e) Filtration and topping up work of transformer shall only be carried out by manufacturer of transformer or its authorised agent. | 1400 | LITRE | |
3 | 3 | Supply and replacement of silica gel grains in the breather assembly of transformers of various capacities including removal of old unserviceable one etc complete all as specified and as directed by Engineer-in-Charge. | 4 | KG | |
4 | 4 | Supply and replacement of breather assembly of size 50mm dia, min 250mm long for transformer of various capacities including removal of old unserviceable one etc complete all as specified and as directed by Engineer-in-Charge. | 8 | EACH | |
5 | 5 | S&F in repair transformer temperature gauge, dial type, having temperature range 0 to 120°C etc complete all as specified and as directed by Engineer-in-Charge. | 8 | EACH | |
6 | 6 | Opening of top cover by unscrewing all nuts, bolts and washers for replacement of transformer HT/LT bushing, lifting of core assembly, cleaning and refixing the complete unit with new cork sheet, gasket, existing / wherever required with new nuts, bolts and washers for transformer capacity 63 to 500 KVA indoor/outdoor type complete all as directed by Engineer-in-Charge. \nNote: - (i) HT/LT bushing shall be measured and paid separately under relevant items of these schedule as 'supply only' items and labour element involved for replacing the same shall deemed to be included in the rate quoted by the tenderer in this item.\n(ii) Repair works to be carried out by manufacturer of transformer or its authorized agent. | 10 | EACH JOB | |
7 | 7 | Supply only HT porcelain bushing suitable for 11 KV grade complete with brass rod & rubber bush, for 63 to 500 KVA capacities of transformer complete all as specified and as directed. | 21 | EACH | |
8 | 8 | Supply only LT bushing suitable for 1100 volts grade complete with brass rod & rubber bush for the rating 63 to 500kVA capacities indoor/outdoor transformer complete all as specified and as directed. | 27 | EACH | |
9 | 9 | M&L for Shifting of transformer carefully of capacity of 63 - 500 KVA from its position upto road n.exc 50 m high by manually or chain pulley arrangement and carrying it to other installation by vehicle (Recovery Van) within Cantonment area n.exc 2KM and install it to new places including commissioning and testing complete all as directed by Engineer-in-Charge.Note:- All necessary requirement of Vehicles and other equipments shall be arranged and payment of the same done by contractors only. | 8 | EACH JOB | |
10 | 10 | Servicing and repair to 11KV/415V Transformer of capacity 63 to 500 KVA.15 MVA including the following works :-\n(a) Transport the transformer to workshop and return back after servicing including installation and commissioning and testing complete all as directed by Engineer-in-Charge.\n(b) Dismantling the transformer limb, draining out transformer oil and lifting the core coil assembly, keep the assembly in oven up to obtain required IR value of the transformer winding complete all as directed by Engineer-in-Charge.\n(c) Cleaning the core coil assembly by oil complete and remove the dirt, sludge in the coil and core gently without making damage of insulation complete all as directed by Engineer-in-Charge.\n(d) Cleaning inside the chamber of transformer, scrapping complete all sludge and iron particle.\n(e) M & L Two coats of oil resistance paint on inside surfaces of transformer over a coat of red oxide metal primer.\n(f) Re-assembling all dismantled parts including provision of new gaskets, spacers, nut, bolt refilling with new transformer oil.\nNote :-(i) The servicing of transformer carried out by authorized dealer of manufacturer of transformer.\n(ii) Oil filtration, supply of new oil will be measured and paid separately.\n(iii) All petty parts including nut, bolts, gaskets, minor welding deemed to be included in the rate quoted.\n(iv) All defective spare parts shall be approved by Board of Officers conveyed by Accepting Officers for replacement. | 10 | EACH JOB | |
11 | 11 | M&L for Rewinding of HT coils suitable for 11000 volts grade with new super enamelled copper wire having Class - F insulation as per existing size and turns for capacity of transformer 63- 500 KVA complete all as directed by Engineer-in-Charge. | 225 | KG | |
12 | 12 | M&L for Rewinding of LT coils suitable for 1100 volt grade with new DPC copper wire having Class F insulation as per existing size and turns for capacity of transformer 63 to 500 KVA complete all as directed by Engineer-in-Charge. | 200 | KG | |
13 | 13 | Supply and replace conservator oil inspection glass after opening by unscrewing nuts, bolts and washers and replacement with heat resistance glass of size n.exc 75 Sqmm and 3mm thick complete with new cork sheet, gasket, nuts, bolts and washers complete all as specified and directed. | 8 | EACH | |
14 | 14 | M&L for Painting of transformer outer surface with one coat of synthetic enamel paint for transformer capacity 63- 500 KVA after preparation of old painted surface by spray painting complete all as directed by Engineer-in-Charge. | 6 | EACH JOB | |
15 | 15 | Supply and replace HT / LT side terminal box (40x40x5 cm) made out of mild steel angle iron and 2mm thick MS sheet including removable cover with required holes on flange to fix at body of transformer and removable cover and fixing with new cork sheet gasket with nuts, bolts and washers including one coat of synthetic enamel paint as under coat and one as finishing coat to both side of box complete all as directed by Engineer-in-Charge. | 2 | EACH | |
16 | 16 | S&F Gun metal gate valve (ISI marked) Class-I, 25 mm bore with iron wheel head screwed both ends for iron pipe suitable for following bore of pipe including taking down old unserviceable one complete all as speficied and directed. Make: Upadhyay/Zoloto/RMCO | 5 | EACH | |
17 | 17 | S&F Heavy duty capacitor of 3 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : Havells Cat Part No:QHBTMC5003X0 or its equivalent model of L&T/Indo asian. | 2 | EACH | |
18 | 18 | S&F Heavy duty capacitor of 5 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : Havells Cat Part No:QHBTMC5005X0 or its equivalent model of L&T/Indo asian. | 2 | EACH | |
19 | 19 | S&F Heavy duty capacitor of 7.5 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : Havells Cat Part No:QHBTMC5007x5 or its equivalent model of L&T/Indo asian. | 2 | EACH | |
20 | 20 | S&F Heavy duty capacitor of 10 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : Havells Cat Part No:QHBTMC50010X0 or its equivalent model of L&T/Indo asian. | 2 | EACH | |
21 | 21 | S&F Heavy duty contactor of 3 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : L&T Cat Part No:CS96146 or its equivalent model of Havells/Indo asian. | 3 | EACH | |
22 | 22 | S&F Heavy duty contactor of 5 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : L&T Cat Part No:CS96127 or its equivalent model of Havells/Indo asian. | 2 | EACH | |
23 | 23 | S&F Heavy duty contactor of 8.5 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : L&T Cat Part No:CS96320 or its equivalent model of Havells/Indo asian. | 2 | EACH | |
24 | 24 | S&F Heavy duty contactor of 10.0 KVAR 3 Phase including taking down old unserviceable one complete all as speficied and directed. Make : L&T Cat Part No:CS96156 or its equivalent model of Havells/Indo asian. | 2 | EACH | |
25 | 25 | S&F 8 step APFC controller relay including taking down old unserviceable one complete all as speficied and directed. Make : Havells Cat Part No:QHOSBSN008 or L&T Cat part No-ETACONM008R. | 6 | EACH | |
26 | 26 | S&F 6 step APFC controller relay including taking down old unserviceable one complete all as speficied and directed. Make : Havells Cat Part No:QHOSBSN006 or L&T Cat part No-ETACONM006R. | 6 | EACH | |
27 | 27 | M&L for Earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth strip 32 X 6 mm as earth lead by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I including taking down old unserviceable earthing plate with accessories. Note:- GI strip upto 7.5 m length shall be deemed to be included in the quoted rate against ibid item. The quantity required over 7.50 m shall be measured and paid under relevant items seperately. | 9 | EACH JOB | |
28 | 28 | M&L for PCC (1:4:8), type D2, (using 40mm graded stone aggregates) as in foundation for filling in mass concrete or for foundation of transformer/poles and sorrounding of transformers etc complete all as specified and as directed by Engr-in-Charge. | 12 | CUM | |
29 | 29 | S& F XLPE Cable joining kit 11000 Volt grade, outdoor termination heat shrinkable type with joining materials and accessories suitable for HT XLPE armoured aluminium condoctor cable of size 95 sqmm 3 core complete including taking down old unserviceable joining kit all as directed by Engineer-in-Charge. | 6 | EACH | |
30 | 30 | S& F XLPE Cable joining kit 11000 Volt grade, indoor termination heat shrinkable type with joining materials and accessories suitable for HT XLPE armoured aluminium condoctor cable of size 95 sqmm 3 core complete including taking down old unserviceable joining kit all as directed by Engineer-in-Charge. | 6 | EACH | |
31 | 31 | Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation, etc n exc 10 sqmtr on plan, in soft/loose soil and getting out complete all as specified and directed. | 394 | CUM | |
32 | 32 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm thick as in soft/loose soil etc complete all as specified and as directed. | 97 | CUM | |
33 | 33 | Removing excavated materials (soil) n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as directed. | 94 | CUM | |
34 | 34 | M&L for Sand cushioning with dry clean river sand for protection/covering of under ground cable in trenches complete all as specified and directed by Engr-in-Charge. \nNote:- Punned thickness only shall be measured for payment. | 94 | CUM | |
35 | 35 | Supply and laying Sub class 'B' well burnt brick, laid flat in trenches as protection to LT XLPE cable complete all as specified and as directed. | 10 | PER 1000 NOS | |
36 | 36 | Supply and laying GI tubing light grade,50 mm bore with all fittings, fixed complete to walls and ceiling or laid in floor for cable crossing complete all as specified and as directed including taking down old unserviceable one. | 60 | RM | |
37 | 37 | Supply, laying XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable with stranded aluminum conductor 1100 volt grade of size 185 Sqmm 3.5 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed including taking down old unserviceable one etc complete all as specified and as directed. | 25 | RM | |
38 | 38 | All as per Item No.37.00 above but size of XLPE cables 70 Sqmm 4.0 Core.\n | 50 | RM | |
39 | 39 | All as per Item No.37.00 above but size of XLPE cables 50 Sqmm 4.0 Core.\n | 50 | RM | |
40 | 40 | All as per Item No.37.00 above but size of XLPE cables 25 Sqmm 4.0 Core.\n | 50 | RM | |
41 | 41 | All as per Item No.37.00 above but size of XLPE cables 16 Sqmm 4.0 Core.\n | 50 | RM | |
42 | 42 | Relaying only XLPE insulated PVC inner sheathed, armoured with galvanized steel strip or wire heavy duty underground cable with stranded aluminum conductor 1100 volt grade of size 150 Sqmm 3.5 Core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing after clearing fault including taking down old unserviceable one etc complete all as specified and as directed. | 50 | RM | |
43 | 43 | All as per item no. 42.00 here in above but for XLPE cable 95 Sqmm 3.5 Core etc complete all as specified and as directed. | 200 | RM | |
44 | 44 | All as per item no. 42.00 here in above but for XLPE cable 70 Sqmm 3.5 Core etc complete all as specified and as directed. | 200 | RM | |
45 | 45 | All as per item no.42.00 here in above but for XLPE cable 35/50Sqmm 3.5 Core etc complete all as specified and as directed. | 200 | RM | |
46 | 46 | All as per item no. 42.00 here in above but for XLPE cable 25Sqmm 3.5 Core etc complete all as specified and as directed. | 200 | RM | |
47 | 47 | All as per item no.42.00 here in above but for XLPE cable 16Sqmm 3.5 Core etc complete all as specified and as directed. | 200 | RM | |
48 | 48 | All as per item no. 42.00 here in above but for XLPE cable 10Sqmm 3.5 Core etc complete all as specified and as directed. | 100 | RM | |
49 | 49 | Supply and fix or lay PVC insulated and sheathed twin core flat cables 1100 volts each core having single stranded aluminium conductor service cable of size 10 sqmm etc complete all as specified and as directed. | 100 | RM | |
50 | 50 | Supply and fix or lay PVC insulated and sheathed twin core flat cables 1100 volts each core having single stranded aluminium conductor service cable of size 4 sqmm etc complete all as specified and as directed. | 100 | RM | |
51 | 51 | Supply and fix or lay PVC insulated and sheathed twin core flat cables 1100 volts each core having single stranded aluminium conductor service cable of size 2.5 sqmm etc complete all as specified and as directed. | 100 | RM | |
52 | 52 | Supply and erecting steel tubular swaged pole 9.00 m long type 410 SP-31 complete with cast iron base plate and final taper plug duly painted with anti corrosive paint internally and externally and upto 1.5 m length of pole above ground level (externally) shall be painted with two coats of synthetic enamel paint in strips of 30 Cm length, black and yellow alternatively and balance of pole with two coats of aluminium paint including dismantling of old unserviceable steel tubular pole of any size with necessary disconnection of electric wire, fitting and fixtures etc as required complete all as specified and as directed by Engr-in-Charge. Make:- Bansal / M/s Calcutta poles ltd or equivalent and approved.\n | 4 | EACH | |
53 | 53 | Supply and fix in repair LT cable jointing kit 1100 volt grade cable for straight through joint , cold shrink type complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm etc complete all as specified and as directed by Engr-in-Charge. \n | 3 | EACH | |
54 | 54 | Supply and fix in repair LT cable jointing kit 1100 volt grade cable for straight through joint , cold shrink type complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm etc complete all as specified and as directed by Engr-in-Charge. \n | 3 | EACH | |
55 | 55 | Supply and fix in repair LT cable jointing kit 1100 volt grade cable for indoor / outdoor termination joint , heat shrink type complete with jointing material and accessories suitable for 4.0 core XLPE armoured aluminium conductor cable of size 70 to 150 sqmm etc complete all as specified and as directed by Engr-in-Charge. \n | 3 | EACH | |
56 | 56 | Cutting or trimming of tree branches after disconnection of electric connection ,to clear OH lines in the area of LT OH lines feeders for a span of 30 m each and removal of the trimmed branches of trees and depositing the same in MCD waste bins inside the campus including resuming electric supply by necessary electric connection etc complete all as specified and directed. | 30 | PER SPAN | |
57 | 57 | M&L for PCC (1:3:6), type C1 (using 20mm graded stone aggregates) as in coping of poles including necessary formwork etc complete all as specified and as directed by Engr-in-Charge. | 1 | CUM | |
58 | 58 | S&F in repair indicator LED lamp ( AC / DC ) . etc complete all as specified and as directed by Engr-in-Charge. Make: Legrand/Siemens/L&T/Havells | 1 | SET OF THREE | |
59 | 59 | S&F in repair 3 phase LED Ammeter etc complete all as specified and as directed by Engr-in-Charge. Make:-L&T Cat part No:WL131020OOO or equivalent in Havells / Legrand. | 1 | EACH | |
60 | 60 | S&F in repair 3 phase LED Voltmeter etc complete all as specified and as directed by Engr-in-Charge. Make:-L&T Cat part No:WL132020OOO or equivalent model from make Havells / Legrand. | 1 | EACH | |
61 | 61 | S&F in repair MCCB, four pole, 100-125 Amps , 415 Volts, thermal and magnetic release, 25 kA, 50Hz, complete all as specified and directed by Engr-in-Charge . Make:- L&T Cat part No:CM90642OOLO of or equivalent model from makeSiemens / Legrand. | 5 | EACH | |
62 | 62 | S&F in repair MCCB, four pole, 250 Amps , 415 Volts, adjustable thermal and fixed magnetic setting, 25 kA, 50Hz, complete all as specified and directed by Engr-in-Charge . Make:- L&T Cat part No:CM90642OOPO of or equivalent model from make Siemens / Legrand. | 2 | EACH | |
63 | 63 | S&F in repair MCCB, four pole, 125-160 Amps , 415 Volts, adjustable thermal and fixed magnetic setting, 25 kA, complete all as specified and directed by Engr-in-Charge . Make:- L&T Cat part No:CM90642OOMO of or equivalent model from make Siemens / Legrand. | 2 | EACH | |
64 | 64 | S&F in repair MCCB, four pole, 630 Amps , 415 Volts, adjustable thermal and fixed magnetic setting, 50 kA, complete all as specified and directed by Engr-in-Charge . Make:-L&T Cat part No:CM9410600T1OG or equivalent model from make of Havells /Legrand. | 1 | EACH | |
65 | 65 | S&F in repair ACB, four pole, 800 Amps , 415 Volts, adjustable thermal and fixed magnetic setting, 50 kA, complete all as specified and directed by Engr-in-Charge . Make:-L&T/Havells /Legrand/Siemens. | 1 | EACH | |
66 | 66 | S&F in repair MCCB, four pole, 400 Amps , 415 Volts, adjustable thermal and fixed magnetic setting,36 kA complete all as specified and directed by Engr-in-Charge . Make:- L&T Cat Part No. CM9410600S1OG or equivalent model from make Siemens /Legrand. | 1 | EACH | |
67 | 67 | S&F in repair MCB, TPN, 415 Volts, adjustable thermal and fixed magnetic setting, 10 KA, 63 amps 'C' series complete all as specified and directed by Engr-in-Charge . Make:- L&T Cat part No:BB40630C of or equivalent in Siemens /Legrand. | 10 | EACH | |
68 | 68 | S&F in repair MCB, SPN, 415 Volts, adjustable thermal and fixed magnetic setting, 10 KA, 63 amps 'C' series complete all as specified and directed by Engr-in-Charge . Make:- L&T Cat part No:BB20630C of or equivalent model from make L&T /Legrand. | 6 | EACH | |
69 | 69 | M&L for painting of LT panel / feeder pillar with one coat of synthetic enamel paint including necessary preparation of old painted steel surfaces etc complete all as specified and as directed. | 8 | SQM | |
70 | 70 | Servicing of LT Panel of size 1.60 m x 1.20 m x 0.60 m after necessary shut down and removing all dust particles and proper layout of LT Panel with gland packing including 2.5 sqmm copper single core copper cable including repairing / replacing of door hinges / door lock etc including thereafter electric connection etc complete all as specified and as directed. | 2 | EACH JOB | |
71 | 71 | S&F in repair onload change over 400 Amps ,415 Volts,50Hz etc complete all as specified and directed by Engr-in-Charge . Make:- L&T/Siemens / Schneider /Legrand / ABB/Havells. | 1 | EACH | |
72 | 72 | S&F in repair onload change over 100 Amps ,415 Volts,50Hz etc complete all as specified and directed by Engr-in-Charge . Make:- L&T/Siemens / Schneider /Legrand / ABB/Havells. | 1 | EACH | |
73 | 73 | S&F in repair onload change over 63 Amps ,415 Volts,50Hz etc complete all as specified and directed by Engr-in-Charge . Make:- L&T/Siemens / Schneider /Legrand / ABB/Havells. | 1 | EACH | |
74 | 74 | M&L for preparation of old painted ( outer exposed surface ) of electric steel swaged tubular poles over all diemension 8.50/ 9.00 meter long, painting starts from ground level with black bituminous paint upto one meter and thereafter applying one coat of aluminium paint including over MS channel / angle iron and clamps with bolts, nuts of street light fittings and writing pole No using black colour synthetic enamel paint of existing size or letters etc complete all as specified and as directed. | 400 | EACH JOB |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy