Border Security Force-BSF has published Cleaning And Repair Of Rcc Overhead Tank And Rcc Water Storage Tanks On Roofs Of Type Iii 20 Type Iv 10 And Type V 01 Qtrs Of Bsf Campus Lakhnaur Under Hq Sdg Bsf Wc Chandigarh. Submission Date for this Tender is 18-03-2021. Water Tank Tenders in BSF CAMPUS LAKHNAUR Punjab. Bidders can get complete Tender details and download the document.
Name of Work:Cleaning and repair of RCC overhead tank & RCC water storage tanks on roofs of type-III/20, type-IV/10 and type-V/01 Qtrs of BSF Campus Lakhnaur under HQ SDG BSF (WC) Chandigarh | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In- harge. With cement mortar 1:4 (1 cement : 4 fine sand) | BI01010001010000000000000515BI0100001113 | 10 | Sqm |
2 | 2 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. | BI01010001010000000000000515BI0100001114 | 0.7 | Per bag of 50 Kg cement used in the mix |
3 | 3 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) | BI01010001010000000000000515BI0100001115 | 42000 | Ltr |
4 | 4 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore | 42 | Each | |
5 | 5 | Cleaning of RCC overhead tank including disposal of slit and rubbish, the cleaning shall consists of following operations:- (i) The bottom of tank shall be cleaned from slit and other deposits (ii) Entire surface area of the sump shall scrubbed throughly with wire brush & removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.3 gm per litre capacity of tank all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001116 | 180000 | Ltr |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy