Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Near, GE (P) AF Gurgaon-Haryana

Military Engineer Services-MES has published Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Near. Submission Date for this Tender is 20-03-2021. Cushioning Supplies Tenders in GE (P) AF Gurgaon Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

27341289
Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Near
Open Tender
Indian
Haryana
GE (P) AF Gurgaon
20-03-2021

Tender Details

Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light To Led Flood Lights From Near Smc To Stn Armoury And From Airmen Mess To Station Sports Complex At Af Station Gurgaon , Shifting Of High Mast Light Pole Including Replacement Of Unserviceable Halogen Light With Energy Efficient Led Flood Lights From Near Smc To Stn Armoury And From Airmen Mess To Station Sports Complex At Af Station Gurgaon Comprising Of Following Work :- A ) M&L To Demolish Old Pcc Foundation Platform And Hiring Hydra Machine For Shifting Of High Mast Light Pole From Airmen Mess To Stn Sports Complex Including Provision Of New Foundation Suitable For 13 Mtr High Highmast Of Rcc Column Size 1 . 0Mtr X1 . 0 Mtr X 2 . 3 Mtr And Raft Size 2 . 4Mtrx2 . 4Mtrx0 . 4 Mtr Using M-25 Concrete And Tmt Steel Bars Of 10 Mm Dia To Be Placed At 150 C/C Both Ways For Raft And 16 No Vertical Bars With 8Mm Dia Bar Stirrups / Rings At 150 C/C For Columns Complete With Suitable Pcc 1:3:6 Lean Concrete Complete All As Directed By Engineer-In-Charge - 02 NosB ) S&F Foundation Nut And Bolt Of Size 2 . 5 Mtr Long And 20 Mm Dia To Be Embeded In Rcc Foundation Complete All As Directed By Engineer-In-Charge- 16 Nos , C ) Supply And Laying Cable Xlpe Insulated Screened Pvc Bedded . Galvanised Steel Strip Or Wire Armoured Electric Power Cable ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 35 Sqmm 3 . 5 Core Complete All As Directed By Engineer-In-Charge - 150 RmD ) Excavation In Trenches In Soft/Loose Soil , Not Exc 1 . 5 Mtr Wide And Not Exc 1 . 5 Mtr Deep And Getting Out In Soft/Loose Soil For Laying Of Cable/ Foundation Of Pole Etc Complete As Specified - 40 . 50 CumE ) Returning Filling Including Spreading , Levelling , Watering And Well Ramming In Layers N . Exc 25 Cm - 25 . 92 CumF ) Removing Excavated Materials Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1 . 5 Mtr Above Gropund Level From Starting Point - 13 . 15 CumG ) M&L For Sand Cushioning In Trenches For Protection Of Lt Under Ground Cable Including Watering And Consolidation - 12 . 20 CumH ) Supply And Laying Well Burnt Sub Class B Bricks , Locally Available In Trenches For Protection Of Under Ground Cable Complete All As Specified - 1350 NosJ ) Supply And Fixing In Replacement Of Energy Saving Environmental Firiendly , Long Life Ip 65 Flood Light With High Power Leds As Light Source , Suitable For High Mast Lighting 150 Watt Including All Fixing Acessories Complete All As Directed By Engineer-In-Charge . Make Havells Cat Part No Jetairisfls150wled757psyml7tg - 12 NosK ) Repair/ Replacement Of Outdoor Type Panel Factory Made Poly Carbonate ( Shock Proof , Rust Free , Corrosion Free , Dust Proof , Acid And Chemical Reisistant Fire Retardant , Having High Impact , Made Of Halogen And Silica Free Recyclable Material ) , Uv Resistant , Having High Grade Gasket Made Of Polyurethane , Should Withstand Glow Wire Test At 650 C Should Be Flame Retardant , , Ser No ( K ) Contd - The Feeder Pillar Panel Should Be As Per Erda Certification With Switchgear Assemblies As Per Iec 60 439-1 . Following Tests Performed And Passed And Satisfactory : ( 1 ) Temperature Rise ( 2 ) Dielectric Properties ( 3 ) Short Circuit Withstand Current Rate Peak & Shor Time Withstand Current And Rated Conditional Short Circuit Current ( 4 ) Effectiveness Of Protective Circuits ( 5 ) Clearance & Creep Age Distand ( 6 ) Mechanical Operation , Mounted On Angle Iron Frame Of Sie 40 Mm X 40 Mm X 6 Mm Thick Complete With Necessary Foundation Work As Directed At Site ( Location ) Make : Univeral Switch Gear Control - 02 Nos PanelsInstrument Chamber :- ( I ) Ryb Phase Indicating Light Led Type - 01 ( Ii ) Control Mcb 6A Sp C Series - 1 SetIncoming:- ( ( I ) Mcb 63 Amps 4 Pole , 10 Ka , 50Hz , 415 Volts - 1 No , Make L&T/Havells , Legrand ( Ii ) Power Contactor 3 Pole , 70 Amps , 50 Hz , 415 Volts - 1 No Make L&T/Havells/Abb Or Equivalent ( Iii ) Time Switch Electronic Type . , Qt One Dial Daily , 240/415 Volt , 50 Hz - 1 No Make : L&T/Havells Or Equivalent ( Iv ) Auto Manual Selector Switch 6 A Sp -1 No Make : L&T/Schneider/Kaycee ( V ) Red Phase Indicating Light Led Type -1 No Make L&T/Vishnu/ SchneiderPanel Wiring For Control Circuit With Copper Flexible 1 . 5Sqmm & Power Wiring 10 Sqmm Flexible . Note : In Case Of Failure , Manual System Should Also Be Provided . , L ) M&L For Drilling Hole Under Hard Standing/ Road In Different Location As Per Site Requirement ( Between 03 Mtr To 12 Mtr Maximum ) For Laying Of Pipe For Protection Of Cable Etc By Means Of Bookle And Without Disturbing The Top Surface And Making Good The Disturbed Surface If Any Complete All As Specified - 08 NosM ) Supply , Fixing And Laying Gi Tube Light Grade 80 Mm Bore ( Make : Prakash/ Jindal/Itc ) - 08 Rm

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work : Shifting of high mast light pole including replacement of unserviceable Halogen light to LED Flood lights from near SMC to Stn Armoury and from Airmen mess to Station Sports Complex at AF Station Gurgaon
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Shifting of high mast light pole including replacement of unserviceable Halogen light with energy efficient LED Flood lights from near SMC to Stn Armoury and from Airmen mess to Station Sports Complex at AF Station Gurgaon comprising of following work :- \na) M&L to demolish old PCC foundation platform and hiring hydra machine for shifting of high mast light pole from Airmen Mess to Stn Sports complex including provision of new foundation suitable for 13 Mtr high highmast of RCC column size 1.0mtr x1.0 mtr x 2.3 mtr and raft size 2.4mtrx2.4mtrx0.4 mtr using M-25 concrete and TMT steel bars of 10 mm dia to be placed at 150 c/c both ways for raft and 16 No vertical bars with 8mm dia bar stirrups / rings at 150 c/c for columns complete with suitable PCC 1:3:6 lean concrete complete all as directed by Engineer-in-Charge - 02 Nos\nb) S&F foundation nut and bolt of size 2.5 mtr long and 20 mm dia to be embeded in RCC foundation complete all as directed by Engineer-in-Charge- 16 Nos\n 1 Job
2 2 c) Supply and laying cable XLPE insulated screened PVC bedded. Galvanised steel strip or wire armoured electric power cable(heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as directed by Engineer-in-Charge - 150 RM\nd) Excavation in trenches in soft/loose soil, not exc 1.5 mtr wide and not exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/ foundation of pole etc complete as specified - 40.50 Cum\ne) Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm - 25.92 Cum\nf) Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above gropund level from starting point - 13.15 Cum\ng) M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation - 12.20 Cum\nh) Supply and laying well burnt sub class 'B' bricks, locally available in trenches for protection of under ground cable complete all as specified - 1350 Nos\nj) Supply and fixing in replacement of energy saving environmental firiendly, long life IP 65 flood light with high power LED's as light source, suitable for high mast lighting 150 watt including all fixing acessories complete all as directed by Engineer-in-Charge. Make Havells Cat Part No JETAIRISFLS150WLED757PSYML7TG - 12 Nos\nk) Repair/ Replacement of outdoor type panel factory made poly carbonate (shock proof, rust free, corrosion free, dust proof, acid and chemical reisistant fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of polyurethane, should withstand glow wire test at 650 C should be flame retardant,\n
3 3 Ser No (k) contd - the feeder pillar panel should be as per ERDA certification with switchgear assemblies as per IEC 60 439-1. Following tests performed and passed and satisfactory : (1) Temperature rise (2) Dielectric properties (3) short circuit withstand current rate peak & shor time withstand current and rated conditional short circuit current (4) Effectiveness of protective circuits (5) Clearance & creep age distand (6) Mechanical operation, mounted on angle iron frame of sie 40 mm x 40 mm x 6 mm thick complete with necessary foundation work as directed at site ( Location) Make : Univeral switch Gear Control - 02 Nos panels\nINSTRUMENT CHAMBER :-\n(i) RYB phase indicating light LED type - 01\n(ii) Control MCB 6A SP C Series - 1 Set\nINCOMING:-\n((i) MCB 63 Amps 4 pole, 10 KA, 50Hz, 415 Volts - 1 No, Make L&T/Havells,Legrand\n(ii) Power contactor 3 pole, 70 Amps, 50 Hz,415 Volts - 1 No Make L&T/Havells/ABB or equivalent\n(iii) Time switch electronic type., QT one dial daily, 240/415 volt, 50 Hz - 1 No Make : L&T/Havells or equivalent\n(iv) Auto manual selector switch 6 A SP -1 No Make : L&T/Schneider/Kaycee\n(v) Red Phase indicating light LED type -1 No Make L&T/Vishnu/ Schneider\nPanel wiring for control circuit with copper flexible 1.5sqmm & power wiring 10 sqmm flexible.\nNote : In case of failure, manual system should also be provided. \n
4 4 l) M&L for drilling hole under hard standing/ road in different location as per site requirement (between 03 mtr to 12 mtr maximum) for laying of pipe for protection of cable etc by means of bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified - 08 Nos\nm) Supply, fixing and laying GI tube light grade 80 mm bore \n(Make : Prakash/ Jindal/ITC)- 08 RM
Disclaimer :