Indian Oil Corporation Limited-IOCL has published Painting Of Above Ground Pump Station Piping And Tank Farm Piping At Wrpl , Viramgam. Submission Date for this Tender is 09-04-2021. Pipe Laying Tenders in IOCL Viramgam Gujarat. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 31-Mar-2021 | Bid duration extension | Date | 09-04-2021 |
Tender No: VGMTS20125: Painting of Above Ground Pump Station Piping and Tank farm piping at WRPL, Viramgam | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 10 | SURFACE PREPARATION | 1 | ||
2 | 20 | Surface preparation using hand tool cleaning including removal of oil, grease and other contaminants by solvent cleaning followed by removal of defective paint, loose mill scale, loose rust, loose paint, weld flux, slag from the metallic surfaces, by hand chipping, hand brushing, hand scrappers / chisels, steel wools, final cleaning with high pressure ( 10000 PSI ) low TDS fresh soft water jet cleaning and drying with compressed air as per the specifications and directions of Site Engineer. Prepared surface shall conform to WJ-4 /ST-2as per NACE no.5/SSPC SP-12 standards. | 3 | 22100 | SQM |
3 | 30 | Sweep blasting (NACE No. 4):- Abrasive (Copper Slag blasting) blasting of piping (all sizes / all heights) conforming to SSPC-SP 7/NACE No. 4 (brush off / sweep blasting). This item is inclusive of providing all required manpower, tools, tackles, consumables, non-consumables, equipments etc. to complete the work in all respects as per technical specifications and instructions of EIC/ Site Engineer. | 5 | 2450 | SQM |
4 | 40 | Wet abrasive blasting : Wet Abrasive blast cleaning of of piping (all sizes / all heights) conforming to Swedish standard SA 2.5 standard. This item is inclusive of providing all required manpower, tools, tackles, consumables, non-consumables, equipments etc. to complete the work in all respects as per technical specifications and instructions of EIC/ Site Engineer. | 6 | 490 | SQM |
5 | 50 | Dry abrasive blasting NACE No. 2 :- Surface preparation of piping (all sizes / all heights) using water washing (WJ4) with low TDS potable sweet water followed by copper slag blasting (conforming to SA 2.5 surface finish) and profile of 40 to 70µm inclusive of all required water, abrasives, equipments, manpower, consumables, tools, tackles, consumables, non-consumables to complete the work in all respects as per specifications and instructions of the EIC/ Site Engineer. | 8 | 1390 | SQM |
6 | 60 | PAINT APPLICATION | 9 | ||
7 | 70 | Supply and application of one coat @ 125µm of surface tolerant epoxy follwed by another coat @ 50µm DFT of Aliphatic polyurethane by airless spray application on piping (all sizes / all heights) including the supply of paints, equipments, tools & tackles, labours, consumables etc. The scope shall include stripe coat over all weld joints/Projected, sharp corners, supply of all equipments, tools, tackles, labour, greasing of all flange studs including supply of grease before the application of paint etc. as per specifications and directions/instructions of EIC/Site Engineer. | 10 | 22100 | SQM |
8 | 80 | Supply and application of two coats (2 x 100µm per coat of Surface tolerant epoxy) and top coat (50µm DFT of Aliphatic polyurethane) by airless spray application, on piping (all sizes / all heights) along with stripe coat of surface tolerant epoxy on all weld joints/ projections by brush including supply of all requisite resources (paints, equipments, tools, tackles, manpower, consumables, non-consumables etc.) to complete the work in all respects as per specifications and directions of the EIC/ Site Engineer. | 11 | 2940 | SQM |
9 | 90 | Supply & application of two coats (2 x 400µm per coat of solvent free epoxy paint) over piping facilities such as Soil/air interface of piping, culvert sections etc.including supply of all requisite resources (paints, equipments, tools, tackles, manpower, consumables, non-consumables etc.) to complete the work in all respects as per specifications and directions of the EIC/ Site Engineer. The thickness of coating shall be around 800-1000 micron. | 13 | 1390 | SQM |
10 | 100 | MISCELLANEOUS | 16 | ||
11 | 110 | Painting lines, Arrows, letter writing etc. with the HB Synthetic Enamel Paint of the Shade/Color as mentioned by Site Enginner/EIC including manual cleaing of the surface. The scope of contractor also includes the re-painting of thickness survey points after final painting. | 17 | 2468 | SQFT |