Provision Of Deficient Sailors Single Living Accommodation At Ins Virabahu , Visakhapatnam ., INS VIRABAHU-Andhra Pradesh

Military Engineer Services-MES has published Provision Of Deficient Sailors Single Living Accommodation At Ins Virabahu , Visakhapatnam .. Submission Date for this Tender is 15-07-2021. Housekeeping Equipments Tenders in INS VIRABAHU Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27325890
Corrigendum : Provision Of Deficient Sailors Single Living Accommodation At Ins Virabahu , Visakhapatnam .
Open Tender
Indian
Andhra Pradesh
INS VIRABAHU
15-07-2021

Tender Details

Provision Of Deficient Sailors Single Living Accommodation At Ins Virabahu , Visakhapatnam . - 2 Lumpsum Price Worked Out By The Contractor For Buildings & Structures, As Listed In Schedule A Part – I On Serial Page No. 34. 3 Lumpsum Price Worked Out By The Contractor For Site Clearance / Area Development / Earthwork Excavation, As Listed In Schedule A Part – Ii On Serial Page No. 35. 4 Lumpsum Price Worked Out By The Contractor For Pile Foundation, As Listed In Schedule A Part – Iii On Serial Page No. 36. 5 Lumpsum Price Worked Out By The Contractor For Internal Electrification, As Listed In Schedule A Part – Iv On Serial Page No. 37. 6 Lumpsum Price Worked Out By The Contractor For Internal Water Supply, As Listed In Schedule A Part – V On Serial Page No. 38. 7 Lumpsum Price Worked Out By The Contractor For Sewage Disposal, As Listed In Schedule A Part – Vi On Serial Page No. 40. 8 Lumpsum Price Worked Out By The Contractor For External Water Supply, As Listed In Schedule A Part – Vii On Serial Page No. 42. 9 Lumpsum Price Worked Out By The Contractor For External Electrification, As Listed In Schedule A Part – Viii On Serial Page No. 43. 10 Lumpsum Price Worked Out By The Contractor For Roads / Path / Hard Standing / Culvert, As Listed In Schedule A Part – Ix On Serial Page No. 44. 11 Lumpsum Price Worked Out By The Contractor For Area Drainage, As Listed In Schedule A Part – X On Serial Page No. 45. 12 Lumpsum Price Worked Out By The Contractor For Fencing / Gate / Compound Wall, As Listed In Schedule A Part – Xi On Serial Page No. 46. 13 Lumpsum Price Worked Out By The Contractor For Lightening Protection, As Listed In Schedule A Part – Xii On Serial Page No. 47. 14 Lumpsum Price Worked Out By The Contractor For Solar Water Heater, As Listed In Schedule A Part – Xiii On Serial Page No. 48. 15 Lumpsum Price Worked Out By The Contractor For Fire Fighting System, Fire Alaram And Detection, As Listed In Schedule A Part – Xiv On Serial Page No. 49. 16 Lumpsum Price Worked Out By The Contractor For Cooling Appliances / Laundry Equipment, As Listed In Schedule A Part – Xv On Serial Page No. 51. 17 Lumpsum Price Worked Out By The Contractor For Dismantling / Demolition, As Listed In Schedule A Part – Xvi On Serial Page No. 52. Schedule A Part - Xx [ Miscellaneous Items ] 18 Schedule A Part - Xvii [ Miscellaneous Items ] 19 Pile Foundation 20 Boring For Bored Cast–In–Situ Piles 450Mm Dia In Any Type Of Soil Strata Except Sdr / Hard Rock And Getting Out And Disposal Of Spoil Outside Md Land Using Hydraulic System Of Boring Method, Complete All As Specified And Directed. 21 Boring For Bored Cast–In–Situ Piles 450Mm Dia In Soft / Fractured Rock And Getting Out And Disposal Of Spoil Outside Md Land Using Hydraulic System Of Boring Method, Complete All As Specified And Directed. 22 Carrying Out Initial Load Test On 450Mm Dia Bored Cast–In–Situ Piles As Per Is – 2911 [ Part – Iv ] Complete All As Specified And As Directed. 23 Carrying Out Lateral Load Test On 450Mm Dia Bored Cast–In–Situ Piles As Per Is – 2911 [ Part – Iv ] Complete All As Specified And As Directed. 24 Carrying Out Pullout Test On 450Mm Dia Bored Cast–In–Situ Piles As Per Is – 2911 [ Part – Iv ] Complete All As Specified And As Directed. 25 Carrying Out Routine Load Test On 450Mm Dia Bored Cast–In–Situ Piles As Per Is – 2911 [ Part – Iv ] Complete All As Specified And As Directed. 26 Carrying Out Low Strain Integrity Test On Bored Cast–In–Situ Piles Of 450Mm Dia Including Analysing The Results As Per Astm D 5882 Complete All As Specified And As Directed. 27 Chipping Out Pile Up To Cut Off Level Including Disposal Up To A Distance Of 50M Complete All As Specified And As Directed. 28 External Water Supply 29 Supply, Install, Testing And Commissioning Of Monoblock Pump Set With Minimum Rating As 15Hp, 70M Head, 5.1Lps With Delivery Size Of 80Mm Bore, 4 Pole, 415Volts, 50Hz, Ac 3 Phase Supply, Electric Driven, Inclusive Of Air Valve At Delivery, Pressure Gauge Along With Cabling By Xlpe Copper Cables From Starter To Pump Set With Cable Tray And Pcc Foundation All As Specified And Directed. 30 Valve Chamber Of Internal Size 750 X 750 X 750 Mm , With 50Mm Thick Pcc 1:5:10, Type E2, Using 40Mm Graded Aggregate For Foundation, 200 Mm Thick Brickwork With Fly Ash Bricks In Cement Mortar 1:6, 100 Mm Thick Pcc, 1:3:6, Type C1, Using 20Mm Graded Aggregate As In Coping, 15 Mm Thick Rendering In Cm 1:4 Internally And Externally Up To 50 Mm Below Gl Including Provision Of Mild Steel Sheet Cover 3 Mm Thick With 40 X 40 X 6 Mm Size Angle Iron Frame Work Embedded In Concrete With Suitable Hinges And Locking Arrangements Including Two Coat Of Synthetic Enamel Black Paint Over A Coat Of Red Oxide Zinc Chrome Primer To Steel Surfaces And Including Necessary Earth Work Excavation In Any Type Of Soil Etc., Removal Of Surplus Soil Off The Premises Complete All As Specified. 31 Cutting The Existing Steel Tubing Line For Alteration / Addition Necessarily Done In Position Without Taking Down And Inserting Tee Of 100X80x80 Mm And Tee Of 80X50x50mm With Collars And Required Specials For Taping Including Necessary Earth Work / Excavation Complete All As Specified And As Directed. 32 Supply, Laying, Testing And Commissioning Of 100 Mm Bore Ductile Iron ( Di ) Pipe, With Spigot And Socket End Centrifugally Cast [ Spun ] , Class K-9 With Double Flanged Conforming To Is - 8329 In Standard Lengths Including Necessary Fittings Such As Tees, Elbows, Bends, Reducers, Taper Pieces Including Testing And Commissioning Complete All As Specified And As Directed. N Note: Di Specials Will Be Measured And Paid Separately. 33 Supply, Installation, Testing And Commissioning Of Lt Panel Board Made Out Of Crca Sheet 2Mm Thick Indoor Pedestal Type Totally Enclosed With Front And Rear Opening, Hinged Doors With Projected On Raised Platform Of Suitable Size, Weather And Water Proof With Necessary Locking Arrangements Along With Lugs, Cable Glands Of Various Sizes For Cables, Danger Notice Plate, Strickering Of Switcher Gear About Termination Of Switch Gear, And The Nuts / Bolts Etc Used Are To Be Made Of Rust Proof Material Including As Per Is:8623, Aluminium Bus Bar Of 100Amps Rating With Heat Proof Colour Code, Insulators Suitable For Three Phase And Four Wire Lt Ac, 50Hz 415V, 100A Capacity Complete With Powder Coating, Necessary Internal Electric Connection As Required With Cpri Test And With The Following Complete All As Specified And As Directed: [ Lt Panel For Pump House Panel ] Nincoming- Nlt 440 Volts 3 Phase, 4 Wire 50 Cycles, 25Ka, Adjustable Type Mccb Of 40 Amps Rated Complete With Overload Protection, No-Volt Thermal Based Release- 01 Nos Noutgoing- Na ) Mcb C-Curve , 32 Amps Tpn, 50Hz, 240 / 415 Volts ( For Utility Services ) - 03 Nos ( 02 For Pumps And 01 Spare ) Nb ) Mcb C-Curve , 16 Amps Tpn, 50Hz, 240 / 415 Volts ( For Utility Services ) - 01 Nos ( 01 For Pumps House Bldg ) Nc ) Led Indicating Lamps For Each Phase With Colour Code Red Yellow Blue For R, Y And B Phases-01 Set Of 03. Nd ) Standered Automatic Star Delta Starter For 3 Phase Pumpset Upto Capacity 15Hp-02 Nos. N N N N N 34 External Electrification 35 Design, Manufacture, Supply, Installation, Testing And Commissioning Of 11Kv / 0.433Kv, 500 Kva Factory Assembled, Factory Tested Ready To Install And Connections Type Compact Substation With An Outdoor Enclosure, Equipped With 500 Kva Ester Oil Cooled Transformer, 3 Way, 11 Kv Ring Main Unit [ Sf6 Gas Insulated Switchgear ] Consisting Of 2 Nos, 630A At 11Kv Fault Making Load Breaking Switch Two Load Breakin Switches & 01 No Vcb Sf6 Gas Insulated Vacum Circuit Breaker And With 630Amps, Air Circuit Breaker As Secondary Side Control Complete With Ht Cable Interconnection In Between Transformer And Rmu And Suitable Sized Busbar Between Tranformer And Lv Incoming Main Switchgear-Acb For Full Load Output Current Of The Transformer And Internal Earthing Connections By Gi Strips All As A Single Transport Unit And Comprising Of The Following Accessories Consisting As Per Details Mentioned In Annexure - A Of Boq Complete All As Specified And As Detailed Below: Note : ( I ) Annexure - A Has Been Uploaded Separately Alongwith Tender Documents And Is Part Of Boq For All Purposes. 36 Supply, Installation, Testing And Commissioning Of Ht 11 Kv, 3 Phase 50 Hz, Indoor Type, Totally Enclosed Metal Clad Switchgear Complete With Vacuum Circuit Breaker Having Rupturing Capacity 350 Mva, Overload And Earth Fault Protection, Ammeter, Voltmeter And Of Rating Upto 630 Amp Complete All As Specified And As Directed. N 37 Supply, Fixing, Jointing And Testing Cable Jointing Kit For 11 Kv Grade Cable For Indoor Termination Cold Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Ht Xlpe Armoured Aluminium Conductor Cable Of Size 120 Sqmm And 3 Core Complete All As Specified And As Directed. N 38 Supply, Fixing, Jointing And Testing Cable Jointing Kit For 11 Kv Grade Cable For Indoor Termination Cold Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Ht Xlpe Armoured Aluminium Conductor Cable Of Size 185 Sqmm And 3 Core Complete All As Specified And As Directed. N 39 Supply, Laying, Jointing And Testing Of Ht Ug Cable, Xlpe Insulated, Screened, Pvc Bedded, Earthened, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 11000 Volts Grade With Stranded Aluminium Conductor Conforming To Is 7098 ( Part Ii ) Passing Through Pipe / Duct / Trenches / Under Floor / Under Road Of Size 185 Sqmm And 3 Core Complete All As Specified And As Directed. N 40 Supply, Laying, Jointing And Testing Of Lt Ug Cable, Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Passing Through Pipe / Duct / Trenches / Under Floor / Under Road Of Size 400 Sqmm And 3.5 Core Complete All As Specified And As Directed. 41 Supply, Laying, Jointing And Testing Of Lt Ug Cable, Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Passing Through Pipe / Duct / Trenches / Under Floor / Under Road Of Size 120 Sqmm And 3.5 Core Complete All As Specified And As Directed. 42 Supply, Laying, Jointing And Testing Of Lt Ug Cable, Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Passing Through Pipe / Duct / Trenches / Under Floor / Under Road Of Size 95 Sqmm And 3.5 Core Complete All As Specified And As Directed. 43 Supply, Laying, Jointing And Testing Of Lt Ug Cable, Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Passing Through Pipe / Duct / Trenches / Under Floor / Under Road Of Size 35 Sqmm And 3.5 Core Complete All As Specified And As Directed. 44 Supply, Laying, Jointing And Testing Of Lt Ug Cable, Xlpe Insulated, Screened, Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor Passing Through Pipe / Duct / Trenches / Under Floor / Under Road Of Size 16 Sqmm And 4 Core Complete All As Specified And As Directed. 45 Supply, Installation, Testing And Commissioning Of Lt Fpb Made Out Of Crca Sheet 3.15Mm Thick Outdoor Pedestal Type Totally Enclosed With Front And Rear Opening, Hinged Doors With Projected On Raised Platform Of Suitable Size, Weather And Water Proof With Necessary Locking Arrangements Along With Lugs, Cable Glands Of Various Sizes For Cables, Danger Notice Plate, Strickering Of Switcher Gear About Termination Of Switch Gear, And The Nuts / Bolts Etc Used Are To Be Made Of Rust Proof Material Including As Per Is:8623, Tinned Copper Bus Bar Of 1000 Amps Rating With Heat Proof Colour Code, Insulators Suitable For Three Phase And Four Wire Lt Ac, 50Hz 415V, 1000 A Capacity Complete With Powder Coating, Necessary Internal Electric Connection As Required With Cpri Test And With The Following Complete All As Specified And As Directed: [ Main Panel ] Nincoming- Na ) Acb 4 Pole, 415 V With Thermal Magnetic Release ( Manual Drawout Type ) Of Capacity 630 A , With Adjustable Type Overload Protection , Short Circuit Protection, With Necessary Cts, Meters And Cable Boxes - 01 No Noutgoing- Na ) Mccb Ac 3 Phase 415 V , 50 Hz 4 Pole 500 A Capacity 35 Ka With Adjustable Type Thermal And Magnetic Setting Relays- 02 No ( 01 For Building Panel 01 Spare ) Nb ) Mccb Ac 3 Phase 415 V , 50 Hz 4 Pole 250 A Capacity 35 Ka With Adjustable Type Thermal And Magnetic Setting Relays- 02 No ( 01 For Dg Amf Panel And 01 Spare ) Nc ) Intelligent Panel Meter To Measure Volatge, Current, Frequency, Power Factor, Kwh Etc. With All Connected Cts - 01 No D ) Led Indicating Lamps For Ech Phase With Colour Code Red Yellow Blue For R, Y And B Phases-01 Set 46 Supply, Install, Test And Commissioning Of Lt Fpb Made Out Of Crca Sheet 3.15Mm Thick Outdoor Pedestal Type Totally Enclosed With Front And Rear Opening, Hinged Doors With Projected An Raised Platform Of Suitable Size Weather And Water Proof With Necessary Locking Arrangements Along With Lugs, Cable Glands Of Various Sizes For Cables, Danger Notice Plate, Strickering Of Switcher Gear About Termination Of Switch Gear, And The Nuts / Bolts Etc Used Are To Be Made Of Rust Proof Material Including As Per Is:8623 Tinned Copper Bus Bar Of 450Amps Rating With Heat Proof Colour Code, Insulators Suitable For Three Phase And Four Wire Lt Ac, 50Hz 415V, 450 A Capacity Complete With Powder Coating, Necessary Internal Electric Connection As Required With Cpri Test And With The Following Complete All As Specified And As Directed: [ Bldg Panel ] Nincoming- Na ) Mccb Ac 3 Phase 415 V , 50 Hz 4 Pole 500 A Capacity 35 Ka With Adjustable Type Thermal And Magnetic Setting Relays- 01 No Noutgoing- Na ) Mccb Ac 3 Phase 415 V, 59 Hz 4 Pole 63 Amps Capacity 25 Ka With Adjustable Type Thermal And Magnetic Setting Relays - 12 Nos ( 10 For Floor Connection+ 01 For Laundary+01 Spare ) Nb ) Intelligent Panel Meter To Measure Volatge, Current, Frequency, Power Factor, Kwh Etc. With All Connected Cts -01 No Nc ) Led Indicating Lamps For Each Phase With Colour Code Red Yellow Blue For R, Y And B Phases-01 Set N 47 Supply, Install, Test And Commissioning Of Lt Panel Board Made Out Of Crca Sheet 2Mm Thick Indoor Pedestal Type Totally Enclosed With Front And Rear Opening, Hinged Doors With Projected An Raised Platform Of Suitable Size Weather And Water Proof With Necessary Locking Arrangements Along With Lugs, Cable Glands Of Various Sizes For Cables, Danger Notice Plate, Strickering Of Switcher Gear About Termination Of Switch Gear, And The Nuts / Bolts Etc Used Are To Be Made Of Rust Proof Material Including As Per Is:8623 Tinned Copper Busbar Of 400Amps Rating With Heat Proof Colour Code, Insulators Suitable For Three Phase And Four Wire Lt Ac, 50Hz 415V, 400A Capacity Complete With Powder Coating, Necessary Internal Electric Connection As Required With Cpri Test And With The Following Complete All As Specified And As Directed: [ Dg Panel ] Nincoming- Na ) Mccb Ac 3 Phase 415 V , 50 Hz 4 Pole 250 A Capacity 35 Ka With Adjustable Type Thermal And Magnetic Setting Relays- 01 No Noutgoing: Na ) Mccb Ac 3 Phase 415 V , 50 Hz 4 Pole 40 A Capacity 25 Ka With Adjustable Type Thermal And Magnetic Setting Relays - 10 Nos ( 05 For 05 Lifts+ 01 For Mi Room+ 01 For Pump House Panel + 01 For Street Light+02 Spare ) Nc ) Led Indicating Lamps For Ech Phase With Colour Code Red Yellow Blue For R, Y And B Phases - 01 Set N N N 48 Integral Led Street Light Luminaire 60 Watts, Comprising Of Epoxy Powder Coated, Pressure Die Cast Aluminium Hosing Enclosed With Glass Cover In Frame, With Suitable Size Of Bracket, Nut And Bolts, Pvc Insulated Three Core Flexible Cable Of Suitable Size And Length Duly Connected To Light Fitting Complete Including Installation And Testing Complete All As Specified And Directed. 49 Loop In Loop Out Box Of Frp Made With Ip65 Protection Of Thermoplastic Circuit Breaker Boxes With Metric Knockouts For Cable Entry And Exit, Combi Climate Cable Glands Of Ip 66 / Ip67 For Cable Entry And Grommets Ip 65 For Conduit For Cable Exit With Mcb 6 Amps, 10Ka, C Curve Overload And Short Circuit Protection, Terminals As Bus Terminals For Cable With Necessary Fixing Arrangements And With Cable Glands All As Specified And Directed. N 50 Earthing Complete With Galvanised Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground [ Earth Pit Not Less Than 2.25 M Deep Below Ground Level ] With Top Edge Of Plate Not Less Than 1.50 M Below Normal Ground Level Connected To 4 Mm Gi Wire [ Earth Lead ] And Gi Pipe 15 Mm, Medium Grade For Earthing Lead Protection To The Extent Of Maximum 7.5M, Earth Plate Electrode Surrounded By 150Mm Thick Packed Layers Of Charcoal And Common Salt Filled In Alternate Layers, Connected To The Plate By Means Of Gi Bolts & Nuts Complete All As Per Electrical Plate No. 3 Of Ssr Part - I, Connected To Panel / Db Including Testing On Completion Including Main Earthing, Charcoal, Common Salt, Pcc [ 1:2:4, Type B1 ] Pit With Ci Top Cover With Handle, Ms Frame Made With 40 X 40 X 6 Mm Angle Iron, Ms Funnel With 20 Mm Bore, Medium Grade Gi Watering Pipe, Wire Mesh, Earth Work Excavation, Return Filling, Removal Of Surplus Soil Etc. Complete All As Specified. 51 Earthing Complete With Galvanised Steel Earth Plate Electrode 600 X 600 X 6 Mm Thick Burried Directly In Ground [ Earth Pit Not Less Than 2.25 M Deep Below Ground Level ] With Top Edge Of Plate Not Less Than 1.50 M Below Normal Ground Level Connected To 32X6 Mm Gi Earth Strip [ Earth Lead ] And Gi Pipe 50 Mm, Medium Grade For Earthing Lead Protection To The Extent Of Maximum 7.5M In Length From Earth Plate, Earth Plate Electrode Surrounded By 150Mm Thick Packed Layers Of Charcoal And Rock Salt Filled In Alternate Layers, Connected To The Plate By Means Of Brass Bolts & Nuts Complete All As Per Electrical Plate No. 3 Of Ssr Part - I, Connected To Panel / Db Including Testing On Completion Including Main Earthing, Charcoal, Rock Salt, Pcc [ 1:2:4, Type B1 ] Pit With Ci Top Cover With Handle, Ms Frame Made With 40 X 40 X 6 Mm Angle Iron, Ms Funnel With 20 Mm Bore, Medium Grade Gi Watering Pipe, Wire Mesh, Earth Work Excavation, Return Filling, Removal Of Surplus Soil Etc. Complete All As Specified. 52 Supply And Installation Of Steel Tubular Swaged Pole Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts And Screws All As Specified Type 410 Sp-31 ( 9M Long ) As Per Is-2713 ( Part-Iii ) Of 1980 And Applying Three Coats Of Black Bituminous Paint Through Out Internally And Two Coats Externally On The Portion Embedded In Concrete And Applying Two Coats Of Aluminium Paint Over A Coat Of Zinc Chrome Primer To The Exposed Surfaces All As Directed Including Dismantling Existing Pole. N ( Note: Excavation And Concrete Shall Be Measured And Paid Separately ) 53 Automatic Power Factor Correction ( Apfc ) Panel Mpp-H Capacitor And Mccb As Incomer, System Of Capacity 180 Kvar With 6 Steps ( 2X50 + 2X25 + 2X15 ) With Suitable Size Of Mcbs Tp And Relays Complete All As Specified And As Directed. 54 Time Switch 415 V Single Phase Of Max 20 Amps Rating With Contactor Fitted Inside Steel Enclosure Complete All As Specified And Directed. 55 Boring Of Holes Under Road, Pavement, Hard Standing By Trenchless Technology Using Ultra Sound Technique And Necessary Machine Including Hdpe Pipe Of 150Mm Dia Suitable For 0.4 Mpa Working Pressure Complete All As Specified And As Directed. 56 Triple Pole And Earth Enclosure With A Three Pin And Earth Plug With Socket 415 V Complete With One Triple Pole Mcb 32 Amp Complete All As Specified And As Directed. 57 Internal Electric Supply 58 Point Wiring Complete With 1100 Volts, Frls Grade, 1.5 Sq.Mm, Single Core, Pvc Insulated, Unsheathed, Multistranded Copper Conductor Cable, Confirming To Is - 694 Drawn Through And Including Medium Grade Pvc Conduit, 20 Mm Dia Including All Accessories Concealed In Walls / Roofs / Floors / Ceiling Etc. And Pressed Metal Flush Box Made Out Of 2Mm Thick Ms Sheet Of Suitable Size And 3 Mm Thick Phenolic Laminated White Sheet Top Cover For Fixing Switches, Fittings, Regulators Etc. Concealed In Walls, Including 1100 Volts, Frls Grade, 1.5 Sq.Mm, Single Core, Pvc Insulated, Unsheathed, Multistranded Copper Conductor Cable As Earth Continuity Conductor With Colour Coding And Connecting To Earth Dolly For One Light / Fan Point / Bell Point Controlled By One Switch / Bell Push Complete All As Specified. Nnote For Item No. 70 To 73: Cutting Chases And Making Good Surfaces Shall Be Included In The Unit Rate. 59 All As Per Serial Item No. 60 Above But One Light Point Controlled By Two Two Way Switches Complete All As Specified. 60 All As Per Serial Item No. 60 Above But One 3 Pin Switch Socket Outlet 5 Amps On Same Board With Other Switches Complete All As Specified. 61 All As Per Serial Item No. 60 Above But One 3 Pin Switch Socket Outlet 5 Amps On Independent Board Complete All As Specified. 62 All As Per Serial Item No. 70 Above But One 3 Pin Switch Socket Outlet 15 Amps On Independent Board, With 1100 Volts, Frls Grade, 2.5 Sq.Mm, Single Core, Pvc Insulated, Unsheathed, Multistranded Copper Conductor Cable Confirming To Is - 694 And Including 1100 Volts, Frls Grade, 2.5 Sq.Mm, Single Core, Pvc Insulated, Unsheathed, Cable As Earth Continuity Conductor. 63 Energy Efficient 4 Feet Led Light Fitting With Tube Minimum 20 Watt Or Nearest Size, 230V Surface Mounted Led Batten Type With Extruded Aluminium / Crca Housing And Robust Constrution With Necessary Acrylic Cover As Diffuser Complete With Mounting Bracket Etc Including Connecting Up With Three Core 1.0 Sqmm Twisted Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed. 64 Energy Efficient 2 Feet Led Light Fitting With Tube Minimum 10 Watt Or Nearest Size, 230V Surface Mounted Led Batten Type With Extruded Aluminium / Crca Housing And Robust Constrution With Necessary Acrylic Cover As Diffuser Complete With Mounting Bracket Etc Including Connecting Up With Three Core 1.0 Sqmm Twisted Flexible Copper Conductor Cable With Suitable Size Complete All As Specified And Directed. 65 Energy Efficent Led Security Light Fitting With Minimum 20 W New Generation Energy Saving &Environmental Friendly Long Life Versatile Pressure Die Cast Aluminium Luminiare With Mid Power Leds As Source And Hf Electronic Driver Pre Wired With 1.0 Sq Mm Copper Conductor Cable Upto Connector Including 2 Mtr Long Gi Tubing Med Grade Suitable Dia Bend To Shape Fixing On Wall With Suitable Ms Brackets Compelte All As Specified And As Directred. N 66 Ceiling Fans Ac Single Phase 230V Of Size 1200Mm Sweep With Complete Set With Fixtures, 5 Star Rating, Mettallic Body And Connecting Up With Three Core Pvc Insulated, Sheathed Flexible Copper Conductor Cable Of Size 1.5 Sq.Mm Complete All As Specified And Directed. 67 Mcb Db Concealed In Wall Vertical Db Tpn 4 Way 415V, 50Hz Double Door, Ip 43 Protection With 200A Rated Bus Bar, Including Provision For Mccb Fp As I / C And Mcbs Sp / Tp As Outgoing Circuits Complete, Fill Empty With Blanks Complete All As Specified And Directed. 68 Mcb Db Concealed In Wall Vertical Db Tpn 6 Way 415V, 50Hz Double Door, Ip 43 Protection With 200A Rated Bus Bar, Including Provision For Mccb Fp As I / C And Mcbs Sp / Tp As Outgoing Circuits Complete, Fill Empty With Blanks Complete All As Specified And Directed. 69 Mcb Sp 6 To 32 Amps 240 Volts, 10Ka Complete All As Specified And Directed. 70 Mcb Spn Upto 32 Amps 240 Volts, 10Ka Complete All As Specified And Directed. 71 Triple Pole And Earth Enclosure With A Three Pin And Earth Plug With Socket Complete With One Triple Pole Mcb 63 Amp Complete All As Specified And As Directed. 72 Mccb 3 Pole 415V, 50Hz, 16Ka Of Capacity 25-100 Amps, Complete All As Specified And Directed. . 73 Mcb Tp 63 Amps 240 Volts, 10Ka, C Curve Complete All As Specified And Directed. . 74 Mcb Db Double Door Type, Concealed In Wall, Spn 8 Way 415V, 50Hz , Sheet Steel Phospetised Powder Painted With Ip 43 Protection With 240A Rated Bus Bar, Fill Empty Way With Blanking Plates Complete All As Specefied And Directed. 75 Sub Main Wiring With 4 Runs Of Single Core 10 Sq.Mm Single Core, Frls, Pvc Insulated, Unsheathed, Multistranded Copper Conductor Cable, 1100 Volts, Frls Grade, Isi Marked, Drawing Through And Including Medium Duty Pvc Conduit, 32 Mm Dia With All Accessories Concealed In Walls / Roofs / Floors / Ceiling Etc. Including Two Run Of 10 Sq.Mm, Single Core, Frls Pvc Insulated, Unsheathed, Multistranded Copper Conductor Cable, 1100 Volts, Frls Grade Earth Continuity Conductor Complete All As Specified. Nnote: 4 Runs Of 10 Sq.Mm, 2 Runs Of 10 Sq.Mm & One Run Of 32Mm Dia Pvc Conduit Will Be Measured As One Unit 76 Sub Main Wiring With 2 Runs Of Single Core 4 Sq.Mm Single Core, Frls, Pvc Insulated, Unsheathed, Multistranded Copper Conductor Cable, 1100 Volts, Frls Grade, Isi Marked, Drawing Through And Including Medium Duty Pvc Conduit, 20 Mm Dia With All Accessories Concealed In Walls / Roofs / Floors / Ceiling Etc. Including One Run Of 4 Sq.Mm, Single Core, Frls Pvc Insulated, Unsheathed, Multistranded Copper Conductor Cable, 1100 Volts, Frls Grade Earth Continuity Conductor Complete All As Specified. Nnote: 2 Runs Of 4 Sq.Mm, 1 Runs Of 4 Sq.Mm & One Run Of 20Mm Dia Pvc Conduit Will Be Measured As One Unit 77 Cooling Appliances 78 Refrigerator, Electric Driven ( Single Phase ) , Capacity 465 Litres Bee 5 Star Rated Completed All As Specified And As Directed. 79 Refrigerator, Electric Driven ( Single Phase ) , Capacity 198 Litres Bee 5 Star Rated Completed All As Specified And As Directed. 80 Refrigerator, Electric Driven ( Single Phase ) , Capacity 282 Litres Bee 5 Star Rated Completed All As Specified And As Directed. ( For Mi Room ) 81 Voltage Stabilizer Of Capacity 2.0 Kva For Automatic Operation , Single Phase, Naturally Air Cooled Indoor Type And Designed For Input Varaition Between 170V To 250 V With Output Voltage Stabilised At 230 V With Accuracy Of ( + / - ) 2.5% Complete All As Directed. 82 Voltage Stabilizer Of Capacity 3.0 Kva For Automatic Operation , Single Phase, Naturally Air Cooled Indoor Type And Designed For Input Varaition Between 170V To 250 V With Output Voltage Stabilised At 230 V With Accuracy Of ( + / - ) 2.5% Complete All As Directed. 83 Voltage Stabilizer Of Capacity 4.0 Kva For Automatic Operation , Single Phase, Naturally Air Cooled Indoor Type And Designed For Input Varaition Between 170V To 250 V With Output Voltage Stabilised At 230 V With Accuracy Of ( + / - ) 2.5% Complete All As Directed. 84 Laundry Equipment 85 Supply, Installation, Testing And Commencing Of Industrial Washing Machine Of Capacity 60Kg Vertical Type Suitable To Supply Of 3 Phase, 415 Volts, 50Hz, Noise Less, Cylinder Made Of Stainless Steel, With Front Loading Safety Door Lock, Fully Automatic, Inlet Water Pipe, Waste Water Drain Pipe Etc Complete All As Specified And Directed. 86 Supply, Installation, Testing And Commencing Hydro Extractor Of Capacity 60 Kg Vertical Type Suitable To Supply 3 Phase, 415 Volts, 50Hz, Direct Drive, Noise Less, Cylinder Made Of Stainless Steel, Safety Door Lock, Fully Automatic Etc Complete All As Specified And Directed. 87 Supply, Installation, Testing And Commencing Tumble Drier Of Capacity 60Kg Vertical Type Suitable To Supply Voltage Of 3 Phase, 415 Volts, 50Hz, Direct Drive, Noise Less, Cylinder Made Of Stainless Steel, Safety Door Lock, Fully Automatic Etc Complete All As Specified And Directed. 88 Mcb Db Vtpn, 8 Way Mounted On Wall / Flush In Wall, Double Door Including Provision Of Mccb 100Amps As Incomer And Mcbs Of Suitable Capacities As Outgoing Complete All As Specified And Directed. 89 Metal And Plug Socket Db, Suitable For Flush Mounting And Surface Mounting Supplied With Neutral Link, With Provision For Mounting Modular Devices, With Mcb, Tpn, 63A, C- Curve Complete All As Specified And Directed. 90 Submain Wiring With Pvc Insulated Frls Copper Conductor Cable Unsheathed For Circuit Along With Earth Wire Including Pvc Rigid Conduit Of Suitable Size With Accessories Complete And Making Good The Disturbed Area For 4 Runs 10.0 Sqmm And 2 Run Of 10. Sqmm Complete Complete All As Specified And Directed. N Note: 6 Runs Of 10 Sqmm And 1 Run Of Pvc Conduit Will Be Measured And Paid As One Unit. 91 Supply, Laying And Testing Lt Cable, Xlpe Insulated, Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor 3.5 Core 35 Sqmm Size Complete All As Specified And As Directed. 92 Aviation Light 93 Cable Pvc Insulated Armoured Pvc Sheathed Lt 1100 V Grade With Copper Conductor Of Size 3 Core 2.5 Sqmm Multi Stranded Conductor Laid In Ground Fixed To Wall Roof Etc With Suitable Clamps Spacers Bolts, Nuts Etc. Complete All As Specified And Directed. 94 Aviation Obstruction Light Led Type Filament-Less Bulb With 10 Watt Bulb Complete Including Standard Fixing Arrangements Complete All As Specified And Directed. 95 Time Switches 250V Single Phase Of 20 Amps Rating With Contactor Fitted Inside Steel Enclosure Complete All As Specified And Directed. 96 Fire Fighting And Fire Alarm And Detection 97 Supply, Laying And Testing Lt Cable, Xlpe Frls Insulated, Screened Pvc Bedded, Galvanized Steel Strip Or Wire Armoured, Electric Power Cables ( Heavy Duty ) 1100 Volts Grade With Stranded Aluminium Conductor 4 Core 10 Sqmm Size Complete All As Specified And As Directed. 98 Supply, Laying And Testing Lt Cable, Pvc Frls Insulated, Pvc Sheathed Cable Galvanized Steel Strip Or Wire Armoured, Electric Control Cables 1100 Volts Grade With Stranded Copper Conductor 2 Core 1.5 Sqmm Size Complete All As Specified And Directed. 99 Gi Cable Tray With Cover For Fixing Xlpe Cables From Duty Room To Terrace For Siren And At Various Places To Accommodate The Cables For Mcbs, Panel Etc Of Size Not Less Than 75X38mm With Necessary Bends, Angles, Supports For Fixing Etc Complete All As Specified And Directed. 100 Dol Starter For Siren Set Upto Capacity Of 2.0 Hp Complete All As Specified And Directed. 101 Dg Set - 102 Silent Engine Generating Set With Accoustic Enclosure As Per Cpcb Norms 415 Volts 160 Kva 3 Phase 0.8 Power Factor 50 Hz, 1500 Rpm Self Excited Self Regulated Brushless Ac Generator Including Accoustic Enclosure Suitable For Ambient Condition At Sea Area And Conforming To Condition Under Is 4722, Bs 5514 / 2613 / 5000 And Comprising Of The Following Accessories Consisting As Per Details Mentioned In Annexure - B Of Boq Complete All As Specified And As Detailed Below: Note : ( I ) Annexure - B Has Been Uploaded Separately Alongwith Tender Documents And Is Part Of Boq For All Purposes. 103 Lifts - 104 Design, Supply , Install, Testing And Commissioning Of Electrically Operated Passenger Gearless Lift Of Capacity 08 Passenger Lift ( G+9 ) ( 544 Kgs ) In The Existing Lift Well, 1.0 M / S Speed With Automatic Gien Micro Stroke Button Control, Microprocessor Based Controller, Simplex Selective / Collective Control Suitable For 3 Phase, 50 Hz 415 Volts Ac Supply Independent Operation With Ac Variable Voltage Variable Frequency ( Ac Vvvf ) Control Closed Loop With Power Saving Regenerative Drive With Suitable Motor And Gear Less Unit To Serve Ground Plus Nine Upper Floors I.E With 10 Stops And 10 Landings With Or Without Attendant Suitable For Synchronised Operation Automatic Power Operated Centre Opening Sliding Stainless Steel Door With Mirror Finish Of 16 Gauge With Infra-Red Sensors All Along The Height For Car Door And View Glass On Upper Part Of All Doors And Built In Announcing System Without Hand Set ( 3 Nos. One Each In Car, Machine Room And Near Ground Floor Landing Door ) Complete With Automatic Rescue / Leveling Device ( Ard ) System ( With + Or -5 Mm ) With Suitable Batteries, Haul Position, Digital Indicators In Car And All Landingwith Call Indicating Lights Etc Complete Conforming To Is- 14665 Including Necessary Joists And Beams For Mounting Machine In Machine Room Including Addition And Alteration To Existing Lift Well If Any And All Necessary Civil Works In Connection With Erection Of Lift Complete All As Specified And As Directed To Serve Upto 10 Floors ( G+9 Floors ) . The Lift Shall Comprise Of The Following Accessories Consisting As Per Details Mentioned In Annexure - C Of Boq Complete All As Specified And As Detailed Below: Note : ( I ) Annexure - C Has Been Uploaded Separately Alongwith Tender Documents And Is Part Of Boq For All Purposes. 105 Design, Supply , Install, Testing And Commissioning Of Electrically Operated Passenger Gearless Lift Of Capacity 13 Passenger Lift ( G+9 ) ( 884 Kgs ) In The Existing Lift Well, 1.5 M / S Speed With Automatic Gien Micro Stroke Button Control, Microprocessor Based Controller, Simplex Selective / Collective Control Suitable For 3 Phase, 50 Hz 415 Volts Ac Supply Independent Operation With Ac Variable Voltage Variable Frequency ( Ac Vvvf ) Control Closed Loop With Power Saving Regenerative Drive With Suitable Motor And Gear Less Unit To Serve Ground Plus Nine Upper Floors I.E With 10 Stops And 10 Landings With Or Without Attendant Suitable For Synchronised Operation Automatic Power Operated Centre Opening Sliding Stainless Steel Door With Mirror Finish Of 16 Gauge With Infra-Red Sensors All Along The Height For Car Door And View Glass On Upper Part Of All Doors And Built In Announcing System Without Hand Set ( 3 Nos. One Each In Car, Machine Room And Near Ground Floor Landing Door ) Complete With Automatic Rescue / Leveling Device ( Ard ) System ( With + Or -5 Mm ) With Suitable Batteries, Haul Position, Digital Indicators In Car And All Landingwith Call Indicating Lights Etc Complete Conforming To Is- 14665 Including Necessary Joists And Beams For Mounting Machine In Machine Room Including Addition And Alteration To Existing Lift Well If Any And All Necessary Civil Works In Connection With Erection Of Lift Complete All As Specified And As Directed To Serve Upto 10 Floors ( G+9 Floors ) . The Lift Shall Comprise Of The Following Accessories Consisting As Per Details Mentioned In Annexure - D Of Boq Complete All As Specified And As Detailed Below: Note : ( I ) Annexure - D Has Been Uploaded Separately Alongwith Tender Documents And Is Part Of Boq For All Purposes. 106 Design, Supply, Install, Testing & Commissioning Goods Lift Of Capacity 500 Kg, Speed 0.5 Metre / Sec With Single Speed Motor, 415 Volts, 3 Phase Ac 50Hz Supply, Conforming To Is-.14665 And As Amended, Suitable To Serve G+01 Upper Floors With Ac Variable Voltage & Variable Frequency Drive ( Vvvf Drive ) Complete With All Standard Accessories, Simplexautomatic & Manual Dual Controlled Operation With / Without Attendant, Centre Opening Doors With Door Drive ( Electric Motor Driven Mechanism ) , Sliding Stainless Steel Doors, Automatic Rescue Device ( Ard ) System, 3D Infra Red Sensor In Full Height Of Door & Built In Announcing System Without Hand Set ( 03 Nos, One Each In Car, Machine Room & Near Ground Floor Landing Door ) Complete All As Specified. 107 Schedule A Part-Viii Nphase -Ii First Year Comprehensive Maintenance Of 8, 13 Passengers & Good Lifts As Provided Under This Contract As Per Serial Item No. 92, 93 And 94 After Completion Of Defects Liability Period Of 02 Years 108 Comprehensive Maintenance Of Electrically Operated 08 Passenger Lifts ( 544 Kgs ) To Serve G+9 Upper Floors All As Mentioned In Si No. 92 Above ( Three Lifts ) During 1St Year After Expiry Of Defects Liability Period All As Specified And Directed 109 Comprehensive Maintenance Of Electrically Operated 13 Passenger Lifts ( 884 Kgs ) To Serve G+9 Upper Floors All As Mentioned Vide Si No. 93 Above ( One Lift ) During 1St Year After Expiry Of Defects Liability Period All As Specified And Directed 110 Comprehensive Maintenance Of Electrically Operated Goods Lifts ( 500 Kgs ) To Serve G+1 Upper Floors All As Mentioned Vide Si No. 94 Above ( One Lift ) During 1St Year After Expiry Of Defects Liability Period All As Specified And Directed 111 Schedule A Part-Ix Nphase -Iii Nsecond Year Comprehensive Maintenance Of 8, 13 Passengers & Good Lifts As Provided Under This Contract As Per Serial Item No. 92, 93 And 94 After Completion Of First Year Comprehensive Maintenance. 112 Comprehensive Maintenance Of Electrically Operated 08 Passenger Lifts ( 544 Kgs ) To Serve G+9 Upper Floors All As Mentioned In Si No. 92 Above ( Three Lifts ) During Second Year After Expiry Of Defects Liability Period And After Completion Of First Year Comprehensive Maintenance. 113 Comprehensive Maintenance Of Electrically Operated 13 Passenger Lifts ( 884 Kgs ) To Serve G+9 Upper Floors All As Mentioned Vide Si No. 93 Above ( One Lift ) During Second Year After Expiry Of Defects Liability Period And After Completion Of First Year Comprehensive Maintenance. 114 Comprehensive Maintenance Of Electrically Operated Goods Lifts ( 500 Kgs ) To Serve G+1 Upper Floors All As Mentioned Vide Si No. 94 Above ( One Lift ) During Second Year After Expiry Of Defects Liability Period And After Completion Of First Year Comprehensive Maintenance. 115 Schedule A Part-X Nphase -Iv Nthird Year Comprehensive Maintenance Of 8, 13 Passengers & Good Lifts As Provided Under This Contract As Per Serial Item No. 92, 93 And 94 After Completion Of Second Year Comprehensive Maintenance. 116 Comprehensive Maintenance Of Electrically Operated 08 Passenger Lifts ( 544 Kgs ) To Serve G+9 Upper Floors All As Mentioned In Si No. 92 Above ( Three Lifts ) During Third Year After Expiry Of Defects Liability Period And After Completion Of Second Year Comprehensive Maintenance. 117 Comprehensive Maintenance Of Electrically Operated 13 Passenger Lifts ( 884 Kgs ) To Serve G+9 Upper Floors All As Mentioned Vide Si No. 93 Above ( One Lift ) During Third Year After Expiry Of Defects Liability Period And After Completion Of Second Year Comprehensive Maintenance. 118 Comprehensive Maintenance Of Electrically Operated Goods Lifts ( 500 Kgs ) To Serve G+1 Upper Floors All As Mentioned Vide Si No. 94 Above ( One Lift ) During Third Year After Expiry Of Defects Liability Period And After Completion Of Second Year Comprehensive Maintenance. 119 Note For Sl No: 95 To 103 :- N ( I ) Comprehensive Maintenance Consists Of Preventive And Breakdown Services Including Replacement Of Material And Labour For Major / Minor Spare Parts And Consumables Like Topping Of Oils / Grease / Door Rollers / Relays / Door Belts / Gate Lock Contacts And Hardware Like Bolts And Nuts Including Load Testing Of Lift For Satisfactory Performance Once In A Year Complete And Rate Quoted By The Tenderer Includes For The Above Lifts. N ( Ii ) Preventive Maintenance Consists Of Carrying Out Routine Check By Skilled Personnel As Specified In Particular Specifications And As Directed By Engineer-In-Charge And Lubricating To All Moving Parts, Topping Parts, Topping Up Of Oils As Per Lubrication Chart Including Material And Labour For All Consumable And Major / Minor Spare Parts. N ( Iii ) Breakdown Maintenance Consists Of Attending To The Faults That May Occur And Carrying Out Necessary Repairs To Electrical, Control Circuits And Mechanical Components Including Materials & Labour For All Minor & Major Spare Parts And Consumables Of The Lift That May Occur During The Operation. 120 ( Iv ) Fortnightly, Quarterly Maintenance Registers Shall Be Maintained And Signed By The Site Engineer And Contractor. N ( V ) Load Testing Shall Be Arranged By The Contractor To The Lift For Which Repairs Were Carried Out As And When Directed By Engr -In-Charge. N ( Vi ) All Maintenance Works Shall Be Carried Out By Well Qualified Tradesmen And Supervisor Of Oem. ( Vii ) The Quoted Rate Shall Be Deemed To Be Included The Above Aspect And For Consumables Such As Timely Toping Up Oils, Acrylic Covers, Fuses, Grease, Waste Cotton, Stationery And Other Miscellaneous Items And All Minor & Major Spare Parts. N ( Viii ) The Tenderer Shall Submit Mou From The Original Manufacturer Of The Lift For Comprehensive Maintenance To Undertake Comprehensive Maintenance During And After Defects Liability Period Directly Or Through Their Nearest Authorized / Accredited Agencies Service Personel. The Mou Shall Be Submitted At Least 06 Months Prior To Issue Of Completion Certificate Of Main Contract As Per Work Order No I.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Mar-2021 85381 Date corrigendum 30 Mar 2021 Date 29-04-2021
2 21-Apr-2021 postpone tender Date 08-05-2021
3 28-Apr-2021 Date corrigendum Date 22-05-2021
4 11-May-2021 85381 date corrigendum 11 May 2021 Date 19-06-2021
5 08-Jun-2021 85381 Date corrigendum 08 June 2021 Date 28-06-2021
6 11-Jun-2021 amendment to tender Other 28-06-2021
7 11-Jun-2021 amendment to drawing Other 28-06-2021
8 26-Jun-2021 85381 Date corrigendum 26 June 2021 Date 15-07-2021

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 40.39 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail