Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #27325044

Special Repairs For Replacement Of Lt Oh Line Ht Fp Structure With Ht Ug Cable And Rmu At Ashoka Park , Pallava Park And Meghadripeta , Visakhapatnam

Issued by Statutory Bodies & Commissions/Committees · Visakhapatnam, Andhra Pradesh
Tender Value
1.47 Crore
Estimated cost
Bid Submission
08 Apr 2021
0 days left
EMD
2.22 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Visakhapatnam → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repairs For Replacement Of Lt Oh Line Ht Fp Structure With Ht Ug Cable And Rmu At Ashoka Park , Pallava Park And Meghadripeta , Visakhapatnam

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Apr-2021 82118 Corrigendum 1 Financial Bid 08-Apr-2021

BOQ

Name of the Work: Special Repairs for Replacement of LT OH Line / HT FP Structure with HT UG Cable & RMU at Ashoka Park, Pallava Park and Meghadripeta, Visakhapatnam
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep in Soft / Loose soil for laying Cables etc. complete all as specified and as directed.BI01010001010000000000000515BI0100001111320Cubic Metre
22Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.BI01010001010000000000000515BI0100001112220Cubic Metre
33Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m complete all as specified and as directed.BI01010001010000000000000515BI0100001113100Cubic Metre
44M & L for Dry River Sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.BI01010001010000000000000515BI010000111465Cubic Metre
55Supplying and laying un–reinforced Precast Concrete Cable Cover, Class HV, Type 1, Flat, of size 300mm x 180mm x 40mm complete all as specified and as directed.BI01010001010000000000000515BI01000011154400Each
66Supplying and laying GI pipe, 100mm dia, Light grade for cable protection at road crossing etc. or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed.BI01010001010000000000000515BI010000111612Runnng Metre
77Cutting Bituminous Road / Hardstanding etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed.BI01010001010000000000000515BI01000011171Cubic Metre
88Supplying, laying and testing HT UG Cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 11000 Volts grade [heavy duty] suitable for Earthed Dystem with aluminium conductor of size 3 Core, 185 Sq.mm conforming to IS – 7098 [Part – II] laid in trenches, fixed to walls or passing through pipes and connecting up including taking down old HT Cables of any description complete all as specified and as directed.BI01010001010000000000000515BI0100001118450Runnng Metre
99Supplying, laying and testing HT UG Cable, XLPE insulated, screened insulated, steel strip armoured and pressure extruded PVC bedded, 11000 Volts grade [heavy duty] suitable for Earthed Dystem with aluminium conductor of size 3 Core, 240 Sq.mm conforming to IS – 7098 [Part – II] laid in trenches, fixed to walls or passing through pipes and connecting up including taking down old HT Cables of any description complete all as specified and as directed.BI01010001010000000000000515BI0100001119750Runnng Metre
1010M & L for Straight Through Joint, Heat Shrinkable type, suitable for 11000 Volts Grade, 3 Core, 120 to 185 Sq.mm, HT, XLPE Insulated, Armoured Power Cable Aluminium Conductor and testing after jointing complete all as specified and as directed.BI01010001010000000000000515BI01000011203Each
1111M & L for Straight Through Joint, Heat Shrinkable type, suitable for 11000 Volts Grade, 3 Core, 240 to 300 Sq.mm, HT, XLPE Insulated, Armoured Power Cable Aluminium Conductor and testing after jointing complete all as specified and as directed.BI01010001010000000000000515BI01000011214Each
1212M & L for Cable End Termination Joint, Heat Shrinkable type, Indoor type, suitable for 11000 Volts, 3 Core, 120 to 185 Sq.mm, HT, XLPE Insulated, Armoured Power Cable with Aluminium Conductor and testing after jointing complete all as specified and as directed.BI01010001010000000000000515BI010000112226Each
1313Supply, install, testing & commissioning of Factory Made 11 KV, 630 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor, 3 Way RMU Consisting of 2 Nos VCB Incoming and 1 Nos VCB Outgoing for Feeder complete all specified and as directed and shall comprise of the following:\n\n[A] RMU shall be 11 KV, 630 Amps, 21 kA for 3 Seconds, SF6 Insulated, Motorized, Outdoor, 8 Way RMU, Right side Extensible with Air Insulated Bus Connected Metering unit, Type tested in line with latest IEC Standards, suitable for operations at a height up to 1000 Meters above sea level and at 40ºC Ambient Temperature without any de-rating, Switchgear and Busbar shall all be contained in a Stainless Steel Enclosure [Minimum 2mm thick AISI 441 Grade] filled with SF6 at 0.3 Bar [300 hPa] Relative Pressure, RMU Tank shall provide Full Insulation and Switchgear shall be insensitive to the environment with Degree of Protection of IP67, Switchgear Operating Mechanism shall have an IP2X Protection and Cable Chamber shall have IP3X Protection, Outer Enclosure shall be IP 54 type tested, Powder Coated with Pure Polyester Based Paint, suitable for the site installation conditions, Accidental Overpressure due to an Internal Arc is limited by the opening of the safety valve, at the bottom of the metal enclosure, away from the operator, Plug in type of extensibility must be provided and coupling busbar should not be exposed to air to avoid oxidation of busbars. Extension of cubicle shall require 450mm to handle and the gap between the coupled RMU’s must be within 10mm.BI01010001010000000000000515BI01000011234Each Job
1413.1[B] Vacuum Circuit Breaker [VCB], comprising of the following: \n[i] 11 KV, 630 Amps, 21 kA VCB with Manual / Motorised Spring Assisted Mechanism and Series Trip Coil – 1 No, \n[ii] Load Break Switch with Built-In Earth Switch – 1 No\n[iii] Position Indicator through clear front mimic in line with IEC 62271-103 – 1 No\n[iv] Self Powered Relay with O/C, S/C, E/F Protection. Relay shall have a Front USB / RS485 / RS232 Port for Laptop Interface / Modbus Communication, LCD Display, 10 Event Records, 5 Fault Records, min 2 setting group and keypad for setting parameters for the relay – 1 No\n[v] CT Ratio 200-100/1-1A for Incoming, 100-50/1-1A for Outgoing and, Class - 1.0, 2.5VA for Metering and Class 10P10, 2.5 VA for Protection – 1 Set\n[vi] Live Cable Indicator with indication at the Front and Three Inlets to check the Synchronization of Phases – 1 No\n[vii] Cable Termination Bushing suitable for up to 1 Run, 3 Core, 185 Sq.mm, XLPE Cable – 1 Set\n[viii] Cable Termination Cover Boots [Push on type] – 1 Set\n[ix] Fault Passage Indicator FPI.\n[x] Circuit Breakers shall have Two Positions: Open or Disconnected and Closed. A separate and independent 3 Position Earthing Switch and disconnector shall be fitted to open and earth the cables in such way that interlocks prevent all unauthorised operations. An operating mechanism shall be used to manually close the circuit breaker and charge the mechanism in a single movement. An independent mechanism shall be fitted for the 3 Positions Earthing Switch and Disconnector Circuit breaker shall be fitted with a local system for manual tripping by an Integrated Push Button. There shall be no automatic reclosing. Circuit Breaker shall have a min of 2000 Mechanical and Electrical Operations and 50 Nos Short Circuit Operations, Disconnector and Earth Switch shall have a minimum of 1000 [M1] Mechanical Operations, 100 Electrical Operations at rated current and 5 Nos Operations at Rated Short Circuit Current.BI01010001010000000000000515BI0100001124
1513.2[C] Air Insulated Bus Connected Metering Unit comprising the following: – 1 Set\n[i] Air Insulated Enclosure with necessary Bus Connection – 1 No\n[ii] PT 11KV / RT 3 / 110V / RT3, 25 VA, Class-1.0 – 1 Set\n[iii] Voltmeter with Selector Switch – 1 No\n[iv] R / Y / B Indicating Lamps – 1 Set\n[v] 11 KV / 230V AC, 1 KVA Control Transformer – 1 No\n[vi] Battery and Battery Charger, 12 Ah, [I/P-230V AC, O/P - 24V DC] – 1 No\n[vii] Self Powered FRTU to detect Short Circuit and Earth Fault on the Cable System, Fault indication through LED Lamps, Reset through Remote and Local. As a minimum, the FRTU shall be capable of performing the following functions: \n[a] Acquiring Analog values from Multifunction Transducers or alternatively through Transducer – less modules and the status inputs of devices from the substation, processing and transmitting to Master stations. Capability to acquire analog inputs from analog input cards receiving standard signals viz. Current Loops 4 – 20 mA, etc.\n[b] Receiving and processing Digital Commands from the Master Station[s] \n[c] Data transmission rates – 300 to 19200 BPS for Serial ports for MODBUS and 10/100 MBPS for TCP/IP Ethernet Ports\n[d] Use of IEC 60870-5-104 Protocol to communicate with the Master Station[s]\n[e] Use of MODBUS over RS485 interface, Protocol to communicate with the MFTs, Protection Relay.\n[f] Have required number of Communication Ports for simultaneous communication with Master Station[s], MFTs.\n[g] FRTU shall have the capability of Automatic Start-Up and initialisation following restoration of Power after an outage without need of manual intervention. All restarts shall be reported to the connected Master Stations.BI01010001010000000000000515BI0100001125
1613.3[h] Remote Database downloading of FRTU from Master Station from SCADA/DMS Control Center.\n[i] Internal Battery Backup to hold Data in SOE Buffer Memory & also maintaining the Time & Date.\n[j] Communication with at least Four Master Stations simultaneously on IEC 60870-5-104\n[k] RTU shall be capable of Acquiring Analog Values through Transducers having output as 4-20 mA, 0-10 mA, 0-+10 mA etc using Analog Input Modules.\n[l] FRTU shall have one TCP/IP Ethernet Port for communication with Master Station[s] using IEC 60870-5-104 Protocol.\n[m] FRTU shall have one Serial RS 485 Port for communication with MFTs and connected in daisy chain using MODBUS Protocol. Minimum 15 Analog Values [Including 4 Energy Values] shall be considered per energy meter.\n[viii] Connection with adjacent modules shall be direct through busbar via metering bushing or through MV cables. VT’s and CT’s from the manufacturer conforming to IEC61869-3 and IEC 61869-2 respectively shall be accepted.BI01010001010000000000000515BI0100001126
1713.4Note:\n\n[a] The make of Vacuum Interrupter, FRTU offered shall be of the same make as of the Ring Main unit.\n[b] An operator situated in front, lateral and rear [A-FLR 21kA – 1 Sec, Downwards Exhaust, for Tank as well as Cable Compartment] of the RMU Switchboard during an internal fault shall not be exposed to the effects of Arcing. Internal Arc Type Test Report for IAC AFLR 21 kA for 1 Sec for both Tank & Cable Box shall be for minimum 3 Way / 3 Function RMU.\n[c] All operations shall be from front of the RMU, including access to cable bushings. Bushings along the sides or the rear of the RMU are not acceptable.\n[d] Construction of Plinth / Foundation for 11KV RMU: The rate quoted is deemed to be including the cost of Plinth / Foundation and shall be paid extra on this account. The foundation shall consists of Two Parallel Brick Walls built using Fly Ash bricks straight or curved on plan to any radius built in Cement Mortar 1:6 of length 2.10m, suitable thickness and height as per the manufacturer’s instructions over PCC Concrete Bed of 150mm thick in PCC 1:4:8, Type D-2, using 40mm graded stone aggregate over 150mm thick Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick watered and rolled, over 150mm thick Sand Bed, rendering to brick surfaces, 15 mm thick in Cement Mortar 1:4, and finishing the top surface even and smooth without using extra cement, applying Three coats of white washing including earthwork excavation of pit size 2.10 X 1.20 X 0.60 Metres complete all as per manufacturer’s recommendations, drawings, as specified and as directed.\n[e] The rate quoted is also deemed to be including the cost of disconnection of HT Cables up to 3 Core, 240 Sq.mm from existing 2 Pole / 4 Pole Structures, removing of cable loop and reconnection to RMU complete all as specified and as directed by the Engineer-in-Charge.\n[f] End termination joints shall be measured and paid separately.BI01010001010000000000000515BI0100001127
1814All as per Serial Item No. 13, but 4 Way Outdoor RMU, 2 Nos VCB Incoming, 2 Nos VCB Outoing with CT Ratio of 200-100/1-1A for incoming and outgoing complete all as specified and as directed.BI01010001010000000000000515BI01000011282Each Job
1915All as per Serial Item No. 13, but 4 Way Outdoor RMU, 2 Nos VCB Incoming with CT Ratio of 200-100/1-1A for incoming and 2 Nos VCB for Transformer Outgoing with CT Ratio of 100-50/1-1A complete all as specified and as directed.BI01010001010000000000000515BI01000011292Each Job
2016Supplying, Installation of Cable Sealing System made of Super Resistant Roxylon, Halogen Free EPDM Modules, consisting of Transit Frames, for 11 KV Cables in RMU Panels, Cable size up to 3 Core, 240 Sq.mm with Bonding & Grounding [Armor Earthing] feature as per IS - 3043 using a suitable Tin Plated Copper Braid complete all as specified and as directed. Make: Roxtec / Hilti / Hawke / AgroBI01010001010000000000000515BI010000113026Each
2117Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and also incuding disconnecting and taking down existing Earthing of any description complete all as specified and as directed.BI01010001010000000000000515BI010000113116Each Job
2218M & L for Precast RCC Cable Route Indicator duly engraved with letters \"HT/LT UG CABLE\", of size 600 X 450mm, 100 mm thick with Semi Circular Shaped Top made of RCC 1:2:4, using 20 mm graded stone aggregate, duly Reinforced with High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10 dia, duly grouted up to 550mm using PCC, 1:3:6, Type C1 complete including necessary excavation and earth work and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on all the exposed concrete surfaces complete all as specified and as directed.BI01010001010000000000000515BI010000113230Each Job
2319M & L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machinery including HDPE Pipe, 150mm bore, 0.4 Mpa working pressure complete all specified and as directed.\nNote: The horizontal directional drilling machine boring shall be minimum shot length of 100m horizontal length in a single span and depth shall not be less than 1.20m. The unit rate quoted is deemed to be inclusive for earth work as required at site for boring at starting and termination ends complete all as directed.BI01010001010000000000000515BI0100001133300Running Metre
2420Taking down existing 6 Pole Structure complete including Cross Arms, Insulators and all other accessories and breaking concrete foundation, removing debris outside MD Land and making good the surface to match with the existing complete all as specified and as directed.BI01010001010000000000000515BI01000011343Each Job
2521Taking down existing 11 metres high Steel Tubular HT Pole complete including ACSR Conductors, Cross Arms, Insulators and all other accessories and breaking concrete foundation, removing debris outside MD Land and making good the surface to match with the existing complete all as specified and as directed.BI01010001010000000000000515BI010000113518Each Job
2622Taking down existing 2 Pole Structure complete including Cross Arms, Insulators and all other accessories and breaking concrete foundation, removing debris outside MD Land and making good the surface to match with the existing complete all as specified and as directed.BI01010001010000000000000515BI01000011365Each Job

AI Tender Summary

OUR REF NO 27325044
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.47 Crore
LAST DATE 08-04-2021
Authority
Authority Name Military Engineer Services
Work Description Special Repairs For Replacement Of Lt Oh Line Ht Fp Structure With Ht Ug Cable And Rmu At Ashoka Park , Pallava Park And Meghadripeta , Visakhapatnam
Basic Detail
Tender No 82118 / E8
Bidding Type Tender
Location
City Visakhapatnam
State Andhra Pradesh
Key Dates
Publish Date 01 Apr 2021
Submission Date 08 Apr 2021
Open Date 15 Apr 2021
Finance
Tender Value 1.47 Crore
Tender Fee 1000
EMD 2.22 Lakhs
Exemption Not Available
Document List
82118Tender.pdf
Tendernotice_1.pdf
BOQ_479894.xls
51F5BB82-1608-4865-9CBD-EC7817B74F83.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Apr 01, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 08, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 08, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 15, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

82118Tender.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_479894.xls

html

51F5BB82-1608-4865-9CBD-EC7817B74F83.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender