}

Supply And Installation Of Fire Extinguishing Equipments At Tcc Srinagar ., TCC Srinagar-Jammu And Kashmir

Tourism Department has published Supply And Installation Of Fire Extinguishing Equipments At Tcc Srinagar .. Submission Date for this Tender is 17-03-2021. Forging machine Tenders in TCC Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

27323549
Supply And Installation Of Fire Extinguishing Equipments At Tcc Srinagar .
Tender
Indian
Jammu And Kashmir
Tcc Srinagar
17-03-2021

Tender Details

Supply And Installation Of Fire Extinguishing Equipments At Tcc Srinagar . -1 Supply, Installation, Testing And Commissioning Of Water Mist & Caf Based Fire Extinguisher Of 50 Ltrs Capacity Consisting Of A Stainless Steel ( Ss 316L ) Water Container, Two Units Of 6Ltrs Compresed Air Cylinder Of Mild Steel And One Atomization Gun With Jet Mode & Spray Mode. The System Operates On Twin Fluid Low Pressure Technology With Operating Pressure Being Lesser Than 15 Bars. ( Preferred Make: Cease Fire / Intime / Equivalent Standard Make ) Eloborate Specifications Are Given Below: 2 Details Technical Parameters 3 Capacity 50 Ltrs Mounted On A Wheeled Trolley 4 Contents Water + Special Foam 5 Test Of Foam Special Foam / Its Components Should Be Tested To Manufacturers Specifications For Viscocity, Density, Refrective Index & Ph Level As Per En 1568 From An International Lab Like Lpcb, Bsi And Mpa Dresden 6 Components As Per Cl. 5.2 As Per Cl. 5.2 Of Bs En 1866-1:2007 The Product Shall Be Tested & Shall Consist Of Extinguisher Body, Wheels, Gripping Device, Cylinder For Propellent, Control Device, Hose Assembly, Main Closure & Operating Device. 7 Safety Device Safety Device Should Be Available As Per Cl.6.8.3 Of Bs En 1866-1:2007 8 Propellant Air 9 Operating Pressure 11 Bar 10 Propellant Cylinder Mild Steel Cylinder With Peso Approval, Capacity 6Ltrs, Pressurised To 300 Bars, Hydrostatic Pressure Test At 500 Bars 11 Hose Length More Than 5 Meters 12 Hose Test The Hose Should Be Tested For No Damage When Rolled Up Or Stored As Per Cl. 6.8.6.6 Of Bs En 1866-1:2007 13 Jet Lancing Distance 14 Meters Minimum 14 Nozzle Modes Jet And Spray 15 Gross Weight Of The System 105 Kg ± 1% 16 Gun Weight 1.6 Kg ± 5% 17 Tested To Standard Product Shall Be Tested To Bs En 1866-1:2007 From Any International Body / Test Lab Like Bsi, Mpa Dresden And Lpcb. Test Report Should Not Be More Than Three Years Old.The Test Report Should Be With Ga Drawing, Components Drawing & List Of Components Along With Moc. 18 Electrical Non Conductivity The Extinguisher Should Be Tested To Bs En 3-7:2004+A1:2007, Clause 9, From Erda For Dielectric Test On Water And Water + Special Foam In Jet Mode & Spray Mode. Test Report Should Not Be More Than 3 Years Old. 19 Class A Fire Rating 43 A 20 Class B Fire Rating Ii B 21 Duration Of Operation 120 Sec Or More 22 Operating Temperature 5°C To 60°C 23 Storage Socket For Nozzle The Equipment Shall Be Provided With A Storage Socket For Nozzle As Per Cl.6.8.6.5 Of Bs En 1866-1:2007 24 Tested For Corrosion The Extinguisher Would Be Tested For External Corrosion As Per Cl.7.2.1 And For Internal Corrosion As Per Cl.7.2.2 Of Bs En 1866-1:2007 25 Colour Of The Body Red Ral 3000 As Per Cl.6.9.1 Of Bs En 1866-1:2007 26 Gun Operating Mode Gun Shall Have Both Jet & Spray Mode Of Operation. Change Over Of Spray Mode To Jet Mode & Vice Vers Shall Be By A Slight Twist Of The Nozzle In Front Of The Gun. 27 Ped Certification The Product Should Be Ped Certified To Ped 2014 / 68 / Eu, Annexiii ( Module H ) 28 Peso Licence The Supplier Should Have A Licence From Peso For Refilling & Storage Of High Pressure Gas Cylinders. 29 Warranty 3 Years 30 Spare Parts Support Minumum 10 Years 31 Supply, Installation, Testing And Commissioning Stored Pressure Water Mist Portable Fire Extinguisher Capacity 6 Liter. ( Stainless Steel ) For Class A, Electrical Fires. Stored Pressure Is: 15683 ( Preferred Make: Cease Fire / Intime / Equivalent Standard Make ) Eloborate Specification Are Given Below: 32 Construction 33 1. The Body Of The Extinguisher Shall Be Of Stainless Steel. 34 2. Vessel Used In The Manufacturing Should Be Constructed Using Deep Drawn Technology And Mig Welding. 35 3. Maximum Height Of The Can Should Not Be More Than 575 Mm Oem Will Certify These Dimensions 36 4. Minimum Diameter 175Mm ( Diameter Should Be Taken From Ped Certificate ) . 37 5. Sheet Metal Thickness Should Not Less Than: 1.5Mm. Thickness As Per Ped Certificate 38 6. Material Of Construction Should Be [ Ss 304 ( 1.4301 ) ] . 39 7. Valve Construction: Forging & Machining. 40 8. External Coating Of Can: Epoxy Polyester Powder Coating. 41 9. Gross Weight Should Be Within The Range Of 10.30Kg To 10.90Kg. 42 10. Content Mass Should Be 5.70Kg To 6.00Kg 43 11. The Equipment Should Have A Specialized Dual Pipe Dip Tube With Rotor To Mix Propellant And Agent. 44 12. Discharge Hose Should Provide And Length Of Flexible Section Should Not Be Less Than 460Mm 45 13. Hose Should Have A Single Fluid Mist Nozzle Attached To Its End. This Nozzle Shall Have Two Set Of 9 Holes Such That Each Set Is Arranged In Two Circles Arranged Concentrically. The Two Set Of Holes Are Aligned Such That Water Stream From Each Hole In Inner Circle Are In Collision Course With Its Pair In Outer Circle. 46 14. Serial No. And Date Of Manufacturing Should Be Embossed On The Body Of The Fire Extinguisher. 47 Performance 48 1. Extinguisher Should Be Stored Pressure Type. 49 2. Each Vessel Needs To Be Checked For Tensile Strength 35 Kgf / Cm2 And Manufacturer Has To Submit Hydrostatic Pressure Testing Certificate For The Same. 50 3. Extinguisher Must Have A Tamper-Proof Safety Pin To Avoid Unintended Use. 51 4. The Extinguisher Must Have Controllable Discharge Mechanism To Provide Flexibility Of Releasing Extinguishing Agent On Targeted Fire Location. 52 5. Min. Discharge Time Should Be 42 Seconds. 53 6. The Working Pressure Should Be At Least 15 Bars. 54 7. Actual Burst Pressure Should Not Be Less Than 105Bar 55 8. Bulk Range Throw Should Be Minimum 2.00 Meters. 56 9. The Extinguisher Must Have A Pressure Gauge To Enable The Checking Of Pressure Gauge’S Working Without Dismantling Or Opening Of The Cylinder. 57 10. Extinguisher Must Be Helium Leak Detection Tested & Test Report Must Be Furnished At The Time Of Delivery. A Sample Of The In-House Test Report To Be Submitted Along With The Bid. 58 11. Fire Rating Should Be Class A: 3A 59 12. Applicable On A, Electrically Started Fire. 60 13. Extinguisher Must Have 03 Year Warranty And A Sample Of The Warranty Card With Terms & Conditions To Be Submitted. 61 Certification 62 1. The Current And Valid Bis Certification Is 15683:2006 Needs To Be Submitted Along With The Offer 63 2. Product Should Be En Approved To Standards “En 3-7:2004 +A1:2007 And En 3-8: 2006” By Eu Notified Body And Ce Marked Along With Isi Marked. 64 3. The Firm Should Submit The Product Performance Test Report From Nabl Accredited Lab. 65 4. Minimum Fire Rating As Is: 15683, For Class A: 3A Needs To Be Provided For The Extinguisher.

Key Value

Document Fees
INR 300 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail