Repair/ Preventive Maintanance Of Water Cooler , Desert Cooler , Split Ac And Central Ac Including Ahu At Dscc Bhopal, GE Dronachal-Madhya Pradesh

Military Engineer Services-MES has published Repair/ Preventive Maintanance Of Water Cooler , Desert Cooler , Split Ac And Central Ac Including Ahu At Dscc Bhopal. Submission Date for this Tender is 01-04-2021. Air Handling Unit Tenders in GE Dronachal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27283526
Corrigendum : Repair/ Preventive Maintanance Of Water Cooler , Desert Cooler , Split Ac And Central Ac Including Ahu At Dscc Bhopal
Open Tender
Indian
Madhya Pradesh
GE Dronachal
01-04-2021

Tender Details

Repair/ Preventive Maintanance Of Water Cooler , Desert Cooler , Split Ac And Central Ac Including Ahu At Dscc Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-04-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ PREVENTIVE MAINTANANCE OF WATER COOLER, DESERT COOLER, SPLIT AC AND CENTRAL AC INCLUDING AHU AT DSCC BHOPAL
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M & L for servicing of split type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge.\nNote : Refrigerant required for topping (R22 / 134) shall be maesured and paid for separately as "supply only rates" under respective item. 35 Each Job
2 2 Replacement of following unserviceable item in Split type AC 1.5/2 TR :-
3 2.1 Blade for condensing fan motor 5 Each
4 2.2 Running Capacitor 45 Mfd 5 Each
5 2.3 Running Capacitor 6 Mfd 5 Each
6 3 S & F in repairs running capacitor (ISI Marked), 36 Mfd suitable for AC of capacity 1.5/2 TR. Complete all as directed. \n 5 Each
7 4 S & F in repairs starting capacitor, 100-120 Mfd suitable for AC of capacity 1.5/2 TR. Complete all as directed.\n 5 Each
8 5 S&F in repairs aluminium fan blade suitable for condenser of split type AC of 1.5/2 TR capacity. 2 Each
9 6 S&F in repairs cooling fan motor of split type AC of 1/30 or 1/35 HP capacity all as directed by Engineer-in-Charge. 3 Each
10 7 S&F in repairs cooling blower fan motor of split type AC of 1/30 or 1/20 HP capacity all as directed by Engineer-in-Charge. 3 Each
11 8 S & F Foam type insulating flexible pipe & air tight outer tapping fitted on ACs of any capacity for suction / discharge copper tubes complete all as specified and directed. 200 RM
12 9 S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 5 KVA. 3 Each
13 10 S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 4 KVA. 2 Each
14 11 S&F in repairs Rotary type Compressor (Sealed Unit) of window / split type AC 1.5 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard. 5 Each
15 12 S&F in repairs Rotary type Compressor (Sealed Unit) of window / split type AC 02 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard. 3 Each
16 13 S&F in repairs Rotary type Compressor (Sealed Unit) of refrigerator 165/175 ltr capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard. 1 Each
17 14 Supply and top up of Refrigerant gas R- 22 in company sealed cylender of capacity all as directed by Engr-in-charge 52 KG
18 15 Supply and top up of Refrigerant gas R-134 in company sealed cylender of capacity all as directed by Engr-in-charge 22 KG
19 16 Supply and fix PCB for split type AC of capacity 1.5/2 TR all as per directed by EIC.make as per site requirment 1 Each
20 17 M&L for cleaning after taking down complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc including preparation and cleaing the surface over a coat of rubber seal paint applying two coats of synthetic enamel paint inside water tank and re-writing the letters on the cooler as directed by Engr-in-Charge. 15 Each
21 18 S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc complete all as specified and directed. 5 RM
22 19 S&F in repairs selector switches three way 230 Volts single phase of standard quality fixed in desert coolers. 5 Each
23 20 S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers including GI wiremesh of 20 Gauge wire and mesh size 100 x 100 mm complete all as directed . 30 Each
24 21 S&F in repairs switch piano type 250 Volts, single pole one ways 5 amps, fixed in desert coolers complete all as specified and directed. \n 20 Each
25 22 S&F in repairs capacitor 4 MFD for fan motors of desert coolers complete all as specified and directed. 10 Each
26 23 S& F in repairs Sub mersible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiring complete all as directed.\n 10 Each
27 24 S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142gm/each. Complete all as directed.\n 5 Each
28 25 S & F in repairs Aluminium fan blade for fan motor of desert cooler 300 mm sweep complete all as specified and directed. 15 Each
29 26 S & F in repair desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer all as directed. 10 Each
30 27 Supply and lay PVC pipe 20 mm dia with fittings in repair fixed on wall / ceiling. 30 RM
31 28 M&L for complete servicing of AHU unit of various capacity installed in DSCC Bhopal including repair/replacement of defective parts like fan belts,oiling greassing cleanning of filters, winding of motor of AHU and other assesories as required at site and testing of plant after replacement of spares completed all as specified and directed by Engineer in Charge 6 Each Job
32 29 M&L for repair and rewinding of blower motor of capacity 7.5 HP/5.5 after taking out from its existing location, transporting to work shop, removing defective burnt wiring, rewinding of motor with new copper wire of suitable gauge including replacement of insulation paper, baking, heating , varnishing of winding, replacement of bearing, any machining and lath work as required, replacement of hardware as required etc and refixing it in existing location, testing comissioning complete up to the satisfaction of engineer in charge. Make of motor:- Bharat Bijili Ltd. 2 Each Job
33 30 Supply and fixing in replacement of HMI display with programming of softwares as per chiler design for 65 TR chiller plant as per existing make and model. 2 Each
34 31 Supply and fixing for liquid sensor including RFGT recovery & pressure testing required for 65 TR chiller plant as per existing make and model installed at site. 1 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail