Military Engineer Services-MES has published Repair Maint Of Internal Wiring And Connected Works For Buildings At Dcra Dad New Leading Area And Otm Accn At Varunapuri Iii Under Age Em Ii Of Ge Nw Vasco 8333/E8. Submission Date for this Tender is 22-03-2021. Electrification Work Tenders in VASCO Goa. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 15-Mar-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 22-03-2021 |
NAME OF WORK : REPAIR / MAINT OF INTERNAL WIRING AND CONNECTED WORKS FOR BUILDINGS AT DCRA, DAD, NEW LEADING AREA AND OTM ACCN AT VARUNAPURI-III UNDER AGE E/M – II OF GE (NW) VASCO. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down aluminium/copper point wiring (light, socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials (credit for above items should be made as per conditions seperately) and making good the disturbed surface all as directed . | 1010 | Point | |
2 | 2 | Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed. | 810 | RM | |
3 | 3 | Taking down existing DB TPN 4 way and DB SPN 8 way of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. | 25 | Each | |
4 | 4 | M&L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision MS boxes made out of 1.6mm thick MS sheet factory painted rectangular as required with 3mm thick plastic laminated sheet top cover / modular top cover for housing switches, sockets etc concealed on wall complete all as specified and directed for the following :- | |||
5 | 4.01 | (a) One light point / Fan point controlled by one switch | 600 | Point | |
6 | 4.02 | (b) One call bell point controlled by bell push | 40 | Point | |
7 | 4.03 | (c) One 3 pin socket outlet, on the same board socket 5 Amps point with other switches with cable 1.5 sqmm | 100 | Point | |
8 | 4.04 | (d) One 3 pin socket outlet, 5 Amps on independent board. | 150 | Point | |
9 | 4.05 | (e) One light point controlled by two, two way switches. | 20 | Point | |
10 | 5 | All as per item No 4.00 above but complete with 1100Volt grade PVC insulated unsheathed multistranded wire with 2.5 sqmm copper cable through casing and capping of suitable size and one run of 2.5 sqmm copper cable as earth continuity conductor including connecting with earth dolly for 15 Amps socket outlet on independent board. | 100 | Point | |
11 | 6 | S&F switch piano, flush type single pole one way 5 Amp complete all as specified and directed. | 400 | Each | |
12 | 7 | All as per item No. 7.00 but of Modular type with module. | 200 | Each | |
13 | 8 | S&F switch piano, flush type single pole two way 5 Amp complete all as specified and directed . | 30 | Each | |
14 | 9 | All as per item No. 8.00 but of Modular type with module. | 10 | Each | |
15 | 10 | S&F in repair switch socket combination 2 in 1, 3 pin 5 Amp and and 2 pin 5 Amp combined flush type universal complete all as specified and directed . | 200 | Each | |
16 | 11 | All as per item No.10.00 but of Modular type with module. | 50 | Each | |
17 | 12 | S&F in repair Switch socket combination 5 in 1 pin 5 / 16A, flush type complete all as specified and directed. | 100 | Each | |
18 | 13 | All as per item No. 12.00 but of Modular type with module. | 50 | Each | |
19 | 14 | S&F in repair ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body complete all as specified and directed. | 600 | Each | |
20 | 15 | S&F in repair Ding dong bell, AC, 230 volts, single phase, 50 HZ complete all as specified and directed | 150 | Each | |
21 | 16 | S & F in repair bell push 5 Amp flush type / Modular type with module complete all as specified and directed. | 30 | Each | |
22 | 17 | All as per item No. 16.00 but of Modular type with module. | 10 | Each | |
23 | 18 | S&F in repair lamp holder, insulated body, with back plate for batten fitting complete all as specified and directed. | 200 | Each | |
24 | 19 | M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 04sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC CONDUIT in Ivory/Grey/white colour medium grade etc fixed on wall/ ceiling including provision of 01 run of 4 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 04 sqmm and 01 run of 4 sqm including 01 run of Pvc conduit will be measured as one length complete all as specified and directed . | 250 | RM | |
25 | 20 | M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC CONDUIT in Ivory/Grey/white colour medium grade etc fixed on wall/ceiling including provision of 01 run of 6.0 sqmm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 6.0 sqm including 01 run of PVC CONDUIT will be measured as one length.complete all as specified and directed. | 560 | RM | |
26 | 21 | S&F MCB DB SPN double door 8 way sheet metal enclosure SPN 240 V 50 Hz horizontal with IP-43 degree protection complete all as specified and directed. | 15 | Each | |
27 | 22 | S&F MCB DB TPN double door 4 way 415 volts 50 Hz horizontal with IP-43 degree protection complete all as specifed and directed | 10 | Each | |
28 | 23 | S&F in repair MCB TPN 'C' series 63 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and directed | 20 | Each | |
29 | 24 | S&F in repair MCB 'C' series SP 06 to 32 Amp, 230 volts, 50Hz, Breaking Capacity 10 KA complete all as specified and directed | 150 | Each | |
30 | 25 | S& F in repairs 'C' series 20 to 32 Amp SPN MCB complete all as specified and directed | 30 | Each | |
31 | 26 | M&L in repair for RCCB , DP, 25 Amp, 30 mA, 230 volts, 50 HZ, 10 KA breaking capacity complete all as specified and directed . | 50 | Each | |
32 | 27 | Supply and fix in repairs MCCB 4 Pole, current rating 100 Amp, Adjustable thermal setting breaking capacity 25 kA at 415V, 50Hz, \n | 15 | Each | |
33 | 28 | S&F in repair deluxe fan regulator electronic stepped type 230 volts 50 Hz complete all as specified and directed | 35 | Each | |
34 | 29 | All as per item No. 28.00 but of Modular type with module. | 15 | Each | |
35 | 30 | S&F in repair Hylum sheet top cover 3 mm thick for fixing switches, sockets, fan regulators etc including cutting into suitable sizes all as specified and directed . | 17 | Sq Mtr | |
36 | 31 | S & F in repair LED INTEGRATED BATTEN surface type tube light fitting type 1 x 20 watt indoor decorative aluminium extruded T5 LED Battens-integrated type complete with all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. | 350 | Each | |
37 | 32 | S & F in repair LED INTEGRATED BATTEN T5 tube light fitting type 1x 10 watt indoor decorative aluminium extruded T5 LED Battens-integrated type complete with all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. | 290 | Each | |
38 | 33 | S & F in repair LED spot light fitting complete recess mounting type 12 Watt with all accessories internally prewilized including connecting up with twin core twisted flexible copper cable and complete all as directed. \nNote:- \n1) For Ser No. 31 to 33 (for LED light fittings) the contractor for submit original manufactures's replacement warranty certificate stating defective light fittings shall be replaced without any extra cost for minimum two years after completion of the work.\n(2) The Contractor shall write CA No and date of completeion on each LED light fittings. \n(3) An amount of 15000/- shall be retained as security deposit against replacement warranty and this amount shall be released after successful completion of two years replacement warranty. Contractor can not be claimed any interest for this amount. | 10 | Each | |
39 | 34 | M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR Part - I and all directed including connections and testing on completion. | 25 | Each |