Construction Of Rcc Glsr, Providing Laying & Jointing Of Pipe Line With Pump Machinery At Village- Umarbawdi, Gram Panchayat Borwa, Block- Bhim, District- Rajsamand With One Year Defect Liability Period
Tender Value
24.50 Lakhs
Estimated cost
Bid Submission
15 Mar 2021
0 days left
EMD
24500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
AMET → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction of RCC GLSR, Providing Laying & Jointing of Pipe Line with Pump Machinery at Village- UmarBawdi, Gram panchayat Borwa, Block- Bhim, District- Rajsamand with one year defect liability period
BOQ
| Name of Work: Construction of RCC GLSR, Providing Laying & Jointing of Pipe Line with Pump Machinery at Village- UmarBawdi, Gram panchayat Borwa, Block- Bhim, District- Rajsamand with one year defect liability period | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Construction of RCC Ground Level Service Reservoir Hillock at Village Umarbawdi | 1 | ||
| 2 | 2 | Construction of RCC Circular Ground Service Reservoirs on Hillock of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab, top roof slab/dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion and food grade epoxy paint to inner face of the container and dome/slab, including refilling and disposing of surplus stuff , all labour and material charges, providing and fixing accessories such as M.S./Alluminium ladder/RCC Stairs inside and outside, manhole frame and cover, puddle collar, ventilators, satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure etc. complete in all respect as per design data, criteria, obligatory requirements and detailed specifications, scope of work and GA drawing. The job include painting the name of the scheme and other details on the reservoir and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. | 2 | ||
| 3 | 3 | The rate indicated below are excluding the cost of pipes, specials and valve required for inlet, outlet, washout, overflow piping arrangement, but inclusive of DI puddle collar for inlet, outlet, overflow and washout pipe of appropriate sizes to be embedded in concrete. | 3 | ||
| 4 | 4 | 50 KL on hillock | 4 | 50000 | /Liter |
| 5 | 5 | Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS : 8329 - 2000 (amended upto date) as vertical pipes for RCC Reservoirs including specials required such as duckfoot bend, bend, tees etc. providing clamps at every 3 mtr , jointing materials such as nuts, bolts, rubber packing, hydraulic testing etc. complete in all resepect upto and from valve chamber as per direection OF EIC, Technical Specification and scope of work. | 5 | ||
| 6 | 6 | (a) Inlet , Outlet, Overflow pipe - 100 mm dia - | 6 | 15 | /Each |
| 7 | 7 | (d) Wash out pipe - 100 mm dia | 7 | 5 | /Each |
| 8 | 8 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work. | 8 | ||
| 9 | 9 | Manually Operated CI Sluice valve of Class PN-1.0 | 9 | ||
| 10 | 10 | 100 mm | 10 | 3 | /Each |
| 11 | 11 | Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6 | 11 | ||
| 12 | 12 | 100 mm dia PN-1.0 | 12 | 3 | /Each |
| 13 | 13 | Providing,Laying, Jointing & Testing of Rising main Line at Village Umarbawdi | 13 | ||
| 14 | 14 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | 14 | ||
| 15 | 15 | DI K-7 Pipe 80 mm dia | 15 | 500 | /mtr |
| 16 | 16 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work. | 16 | ||
| 17 | 17 | Manually Operated CI Sluice valve of Class PN-1.0 | 17 | ||
| 18 | 18 | 80 mm | 18 | 2 | /Each |
| 19 | 19 | 100 mm | 19 | 1 | /Each |
| 20 | 20 | Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI single Air Valve Flanged/ Screwed type of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended upto date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1,Body seat ring - Leaded tin bronze/ SS , Seal ring and face ring - EPDM/NBR, Ends flanged according to IS:6418 or screwed type shall have external pipe threads conforming to IS:554, Fasteners - CS. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.\nNote: Rates are exclusive of connecting tee, pipe piece and earth work. | 20 | ||
| 21 | 21 | Class PN 1.6 | 21 | ||
| 22 | 22 | 50 mm S-2 Type | 22 | 2 | /Each |
| 23 | 23 | Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work.\n19.36.1 PN 1.0 rating | 23 | ||
| 24 | 24 | Class PN 1.0 | 24 | ||
| 25 | 25 | 80 mm dia | 25 | 2 | /Each |
| 26 | 26 | 100 mm dia | 26 | 1 | /Each |
| 27 | 27 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. | 27 | ||
| 28 | 28 | In all type of soil | 28 | ||
| 29 | 29 | For HDPE pipe line dia up to 110 mm | 29 | 250 | /mtr |
| 30 | 30 | In soft Rock | 30 | ||
| 31 | 31 | For HDPE pipe line dia up to 110 mm | 31 | 150 | /mtr |
| 32 | 32 | In Hard Rock ( Blasting prohibited) | 32 | ||
| 33 | 33 | For dia of pipe up to 150 mm nominal. | 33 | 100 | /mtr |
| 34 | 34 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths Dl standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 5382 1985 such as tees, bends, tapers, caps etc. within trenches in DI pipe line complere including all marerial, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work) | 34 | ||
| 35 | 35 | AJS Tee , Bend, Reducer (All End Socketed) | 35 | ||
| 36 | 36 | Upto 300 mm Diameter | 36 | 100 | /Kg. |
| 37 | 37 | Providing,Laying, Jointing & Testing of Distribution pipe Line at Village Umarbawdi | 37 | ||
| 38 | 38 | Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. | 38 | ||
| 39 | 39 | DI K-7 Pipe 80 mm dia | 39 | 410 | /mtr |
| 40 | 40 | Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . \nNote : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.\nSupply may be in coil or straight length in 6 M/12 M. | 40 | ||
| 41 | 41 | HDPE PE-80 PN - 6 | 41 | ||
| 42 | 42 | 90 mm dia | 42 | 1000 | /mtr |
| 43 | 43 | 75 mm dia | 43 | 515 | /mtr |
| 44 | 44 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. \nNote: Rates are exclusive of tail piece/ dismantling joints and earth work. | 44 | ||
| 45 | 45 | Manually Operated CI Sluice valve of Class PN-1.0 | 45 | ||
| 46 | 46 | 80 mm | 46 | 4 | /Each |
| 47 | 47 | 100 mm | 47 | 1 | /Each |
| 48 | 48 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. | 48 | ||
| 49 | 49 | In all type of soil | 49 | ||
| 50 | 50 | For HDPE pipe line dia up to 110 mm | 50 | 1443.75 | /mtr |
| 51 | 51 | In soft Rock | 51 | ||
| 52 | 52 | For HDPE pipe line dia up to 110 mm | 52 | 385 | /mtr |
| 53 | 53 | In Hard Rock ( Blasting prohibited) | 53 | ||
| 54 | 54 | For dia of pipe up to 150 mm nominal. | 54 | 96.25 | /mtr |
| 55 | 55 | Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. | 55 | 29 | /Cum |
| 56 | 56 | Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work. | 56 | ||
| 57 | 57 | M20 grade Nominal Mix\n1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm\nnominal size). | 57 | 40 | /Cum |
| 58 | 58 | Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths Dl standard specials with rubber ring (EPDM)/ nut bolt and insertion sheet and jointing as per IS: 5382 1985 such as tees, bends, tapers, caps etc. within trenches in DI pipe line complere including all marerial, labour, taxes, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge (excluding earth work) | 58 | ||
| 59 | 59 | AJS Tee , Bend, Reducer (All End Socketed) | 59 | ||
| 60 | 60 | Upto 300 mm Diameter | 60 | 120 | /Kg. |
| 61 | 61 | Providing, lowering, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning and as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6\n | 61 | ||
| 62 | 62 | 100 mm dia | 62 | 2 | /Each |
| 63 | 63 | Providing, installation, testing and commissioning of pump set at Village Umarbawdi | 63 | ||
| 64 | 64 | Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee. | 64 | ||
| 65 | 65 | 2 Nos Pump Sets x 5.00 HP Each (Q- 2.5 LPS , H- 70 m) For existing OW | 65 | 2 | /Each |
| 66 | 66 | Supply and Fixing of Electric control feeder panel comprising of suitable rating MCCB , Fully automatic star-delta starter, over load relay , ampere meter with CTs, Volt meter , Phase prevender, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set . The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating. panel should be of minimum size 35 x 35 x 5 mm ) duly bolted/screwed with enclosure box having 4 legs. each leg's length 18\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plate form. The size of CC plateform should be equal or bigger than the base size of panel feeder panel having height of at least 200 mm from ground level. The panel should having opening of suitable size in front of space for engery meter with glass for meter reading. operation of panel should be suitable for on 440 volt. | 66 | ||
| 67 | 67 | Above 5.00 HP & upto 10 HP | 67 | 2 | /Each |
| 68 | 68 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. | 68 | ||
| 69 | 69 | MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet) | 69 | 50 | /Kgs. |
| 70 | 70 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover. | 70 | ||
| 71 | 71 | 0 to 10.0 kg/cm² | 71 | 1 | /Each |
| 72 | 72 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. : 3 core 4.0 mm2 | 72 | 60 | /mtr |
| 73 | 73 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. | 73 | ||
| 74 | 74 | 4core 10.00 Sq. mm | 74 | 40 | /mtr |
| 75 | 75 | Providing & Lowering in tube well ISI marked GI Pipe “B\" class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. | 75 | ||
| 76 | 76 | 50 mm dia | 76 | 30 | /mtr |
| 77 | 77 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. | 77 | 4 | /Each |
| 78 | 78 | Only Lowering of the submersible pump set in to tube well along with submersible cable,lowering pipes depth up to 120 mtr, specials etc and coiommissioning of the tube well . The job also include cables jointing, checking of discharge of pump set , interconnection of lowering pipe from nearby distribution pipeline, checking of the strater and reporing for completion of job or fault/problem if any. | 78 | ||
| 79 | 79 | For three phase pump set | 79 | ||
| 80 | 80 | G.I. Double Flanged Pipe Lowering Assembly of nominal dia | 80 | ||
| 81 | 81 | 50 mm dia | 81 | 1 | /Each |
AI Tender Summary
Tender Timeline
Mar 06, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedMar 15, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 16, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender