| 1 | 1 | Panel board and cabling | BI01010001010000000000000515BI0100001113 | | |
|---|
| 2 | 1.01 | od330261/2020_2021 : 1. Supply, conveyance, installation testing and commissioning of floor mounting fully partitioned, dust and vermin proof panel assembly as per form 4 of IS 8623 (with latest amendments) comprising of the following components/devices using 1.6mm CRCA sheet as per approved design and requirement, with front and near access facility, bus bar chambers, hinged doors for all switchgear compartments, earthing the doors using 4 as mm braided copper conductor, providing necessary cut-outs for meters, relays, indication lamps, bus bar interconnection. Volimeters, Ammeters CT's etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/flats/slotted angles etc shall not be used for the fabrication of panel assembly (cable-top-entry) <br>1) 120A 10KA 4P MCCB set at 100 A- 1No 2) 100 A 10KA 4PMCCB - 1No AMF control to be provided for automatic change over from KSEB supply to DG supply in case of power failure. AMF relay, contractors etc complete as required shall be provided in the panel including all wiring as required. Outgoing : 1) 100 A 10KA 4P MCCB Set at 80A - 1No 2) 63A 10KA 4P MCB - 1 | BI01010001010000000000000515BI0100001114 | 1 | each |
|---|
| 3 | 1.02 | od330262/2020_2021 : 2. Supply: conveyance, installation testing and commissioning of floor mounting fully partitioned, dust and vermin proof panel assembly as per form 4 of JS 8623 (with latest amendments) comprising of the following components/devices using 1.6mm CRCA sheet as per approved design, and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switchgear compartments, earthing the doors using 4sq mm braided copper conductor, providing necessary cut-outs for accounting meters, relays, indication lamps, bus bar interconnection, Voltmeters, Ammeters CT's etc, detachable covers for bus bar chamber an cable alley, powder coating the assembly after subjecting to 7 tank process etc, as required. CRCA sheet alone be used for the fabrication. Angles/flats/a=slotted angles etc shaall not be used for the fabrication of panel assembly (cable-top entry) Incoming 1) 100 A 10 KA 4PMCCB set at 100A- 1No 2) 63A 10KA 4P MCB- 1No. 3) 100A Change over Switch- 1No. Manual COS from KSEB supply to DG supply in case of power failure. Outgoing 32A10KA4P MCB – 4No. | BI01010001010000000000000515BI0100001115 | 1 | each |
|---|
| 4 | 1.03 | od330263/2020_2021 : 3. Supply: laying and commissioning of PVC sheathed 1.1KV grade 3.5 x 35 sqm armoured aluminium cable including excavation (60 on depth ) laying of brick & sand, chipping of the floor, closing of walls etc as directed completely from AMD panel at ACSTI Training block electrical room to MSB at Hostel. | BI01010001010000000000000515BI0100001116 | 130 | metre |
|---|
| 5 | 1.04 | od330264/2020_2021 : Supply, laying and commissioning of PVC sheathed 1.1kv grade 3.5c x 9.5 sq. mm armoured aluminium cable using clamps noted along with the cables, spacing of clamps not exceeding 60 cms in existing ray or wall as directed complete, From AMF panel at ACSTI Training block Electrical room to CS Panel as ACSTI Training block Electrical room. | BI01010001010000000000000515BI0100001117 | 30 | metre |
|---|
| 6 | 1.05 | od330265/2020_2021 : 5.1 Supply and Carrying out cable and termination for the following cables using brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size etc. complete.<br>3.5Cx95sq.mm Al Cable (kseb meter panel & AMF Panel) | BI01010001010000000000000515BI0100001118 | 2 | each |
|---|
| 7 | 1.06 | od330266/2020_2021 : 5.2 Supply and Carrying out cable and termination for the following cables using brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size etc. complete.<br>3.5Cx70 sq.mm Al Cable (GC Panel & AMF panel) | BI01010001010000000000000515BI0100001119 | 1 | each |
|---|
| 8 | 1.07 | od330267/2020_2021 : 5.3 Supply and Carrying out cable and termination for the following cables using brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size etc. complete.<br>3.5Cx70sq.mm Al Cable (CS Panel & AMF Panel) | BI01010001010000000000000515BI0100001120 | 2 | each |
|---|
| 9 | 1.08 | od330268/2020_2021 : 5.4 Supply and Carrying out cable and termination for the following cables using brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size etc. complete.<br>4Cx35 sq.mm Al Cable (MSB AT Hostel & AMF Panel) | BI01010001010000000000000515BI0100001121 | 2 | each |
|---|
| 10 | 1.09 | od330269/2020_2021 : 5.5 Supply and Carrying out cable and termination for the following cables using brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size etc. complete.<br>4Cx10 sq.mm Al Cable (MSB AT Hosel) | BI01010001010000000000000515BI0100001122 | 4 | each |
|---|
| 11 | 1.1 | od330270/2020_2021 : 5.6 Supply and Carrying out cable and termination for the following cables using brass cable gland, compression type aluminium crimping lugs, gland earthing of adequate size etc. complete.<br>2Cx6sq.mm Al Cable (pump room & electrical room) | BI01010001010000000000000515BI0100001123 | 2 | each |
|---|
| 12 | 1.11 | od330271/2020_2021 : 6.1 Cleaning and Painting with a suitable painting of following panels<br>common service panel (size-2.2mx1.8mx0.7m) | BI01010001010000000000000515BI0100001124 | 21.44 | each |
|---|
| 13 | 1.12 | od330272/2020_2021 : 6.2 Cleaning and Painting with a suitable painting of the following panels<br>SSB-1(Size-2mx15mx0.7m) | BI01010001010000000000000515BI0100001125 | 16.9 | each |
|---|
| 14 | 1.13 | od330273/2020_2021 : 6.3 Cleaning and Painting with a suitable painting of the following panels<br>SSB-2 (Size-2mx1.5mx0.7m) | BI01010001010000000000000515BI0100001126 | 16.9 | each |
|---|
| 15 | 1.14 | od330274/2020_2021 : 6.4 Cleaning and Painting with a suitable painting of the following panels<br>SSB-3 (Size-2mx1.5mx0.7m) | BI01010001010000000000000515BI0100001127 | 16.9 | each |
|---|
| 16 | 1.15 | od330275/2020_2021 : 6.5 Cleaning and Painting with the suitable painting of the following panels<br>Metering panel (size-1mx1.2mx0.5m) | BI01010001010000000000000515BI0100001128 | 16.9 | each |
|---|
| 17 | 1.16 | od330276/2020_2021 : 7. Painting/stickering letters or figures of the sizes 1cm, 1.5cm or 2.5cm bright neatly as identification mark to MSB, SSB, CSP, AMF panel etc as required. | BI01010001010000000000000515BI0100001129 | 250 | each |
|---|
| 18 | 1.17 | od330277/2020_2021 : 8.1 Supply/laying/fixing of earthing conductor CU flat/wires jointing as per IS:3043 /87 I pulling through pipes, fixing directly on trays along with cables/directly in-ground and giving necessary and cushioning etc as required with all accessories required for successful installation as instructed by the engineer in site.<br>8 SWG Copper | BI01010001010000000000000515BI0100001130 | 19 | metre |
|---|
| 19 | 1.18 | od330278/2020_2021 : 8.2 Supply/laying/fixing of earthing conductor CU flat/wires jointing as per IS:3043 /87 I pulling through pipes, fixing directly on trays along with cables/directly in-ground and giving necessary and cushioning etc as required with all accessories required for successful installation as instructed by the engineer in the site.<br>25 x 3 cu strip | BI01010001010000000000000515BI0100001131 | 15 | metre |
|---|
| 20 | 1.19 | od330279/2020_2021 : 9. Supply, laying and commissioning of PVC insulated PVC sheathed 1.1kv grade 1RX2CX6 sq.mm armoured aluminium cable including excavation (40cm depth), laying of brick & sand, chipping of floor, chasing of walls etc., as directed complete from electrical room to pump room for pump control. | BI01010001010000000000000515BI0100001132 | 100 | each |
|---|