Special Repairs To Lt Panels Of Various Locations And Sub-Stations Alongwith Connected Items And Provn Of Augmentation Of Interconnecting Electric Supply From Transformer To Existing Overhead Line Of Bde Camp At Rayang Mil Stn Under Ge 872 Ews, RAYANG-Arunachal Pradesh

Military Engineer Services-MES has published Special Repairs To Lt Panels Of Various Locations And Sub-Stations Alongwith Connected Items And Provn Of Augmentation Of Interconnecting Electric Supply From Transformer To Existing Overhead Line Of Bde Camp At Rayang Mil Stn Under Ge 872 Ews. Submission Date for this Tender is 30-03-2021. Electrical Panel Tenders in RAYANG Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27261927
Corrigendum : Special Repairs To Lt Panels Of Various Locations And Sub-Stations Alongwith Connected Items And Provn Of Augmentation Of Interconnecting Electric Supply From Transformer To Existing Overhead Line Of Bde Camp At Rayang Mil Stn Under Ge 872 Ews
National Competitive Bid
Indian
Arunachal Pradesh
RAYANG
30-03-2021

Tender Details

Special Repairs To Lt Panels Of Various Locations And Sub-Stations Alongwith Connected Items And Provn Of Augmentation Of Interconnecting Electric Supply From Transformer To Existing Overhead Line Of Bde Camp At Rayang Mil Stn Under Ge 872 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 45200.0 /-
Tender Value
INR 22.60 Lakhs /-

BOQ Items

NAME OF WORK : SPECIAL REPAIRS TO LT PANELS OF VARIOUS LOCATIONS & SUB-STATIONS ALONGWITH CONNECTED ITEMS AND PROVN OF AUGMENTATION OF INTERCONNECTING ELECTRIC SUPPLY FROM TRANSFORMER TO EXISTING OVERHEAD LINE OF BDE CAMP AT RAYANG MIL STN UNDER GE 872 EWS
Sl. No. Item Description Item Code / Make Quantity UNITS
1 1 Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for of Laying of Cable Line, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. BI01010001010000000000000515BI0100001113 94.5 CUBIC METRE
2 2 Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line, etc. with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed. BI01010001010000000000000515BI0100001114 94.5 CUBIC METRE
3 3 Supply & Laying XLPE insulated, Armoured, Heavy duty Electric Cable with Aluminium Stranded Conductor, 1100 Volts grade, Cross-sectional Area 300 Sqmm, 3½ Core and Testing, complete all as specified and as directed. \nNOTE : Earth Works, Pipes, Concrete Cable Cover, etc. will be Measured and Paid separately under relevent Items. BI01010001010000000000000515BI0100001115 350 RUNNING METRE
4 4 M&L Cable Jointing Kit for 11 KV (Earthed) Grade Cable for Outdoor Termination Heat Shrink type Joint complete with Jointing Materials and Accessories suitable for 3½ Core XLPE Armoured Aluminium Conductor Cable of size 240 Sqmm to 300 Sqmm and Testing, complete all as specified and as directed. BI01010001010000000000000515BI0100001116 2 EACH
5 5 M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.\nNOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured. BI01010001010000000000000515BI0100001117 28.35 CUBIC METRE
6 6 Supply & Laying Bricks, Sub-class ‘B’, Well burnt of size 230x115x75mm, Covering as Mechanical Protection to Cable, laid Flat dry with Width Equal to Length of Brick, complete all as specified and as directed. BI01010001010000000000000515BI0100001118 3850 EACH
7 7 Taking down Old Unserviceable Feeder Pillar Box/ Panel Board (both Outdoor and Indoor type) from Existing Position (for Item No. 9 to 13) after disconnect-ing All Electric Connections and providing Temporary Restoration of Normal Electric Supply till Final installation of Feeder Pillar Box/ Panel Board including Making good Disturbed Surfaces of Floors, Walls, etc., complete all as specified and as directed. BI01010001010000000000000515BI0100001119 4 EACH JOB
8 8 Supply, Installation & Commissioning Feeder Pillar Box Factory Made (CPRI approved Manufacturer), made out of 3.15mm thick for Load Bearing and 2.00mm thick for Non-load Bearing CRCA Sheet, Outdoor Cubical type, with Locking Arrangement, Fully Compartmentalized, Totally Enclosed Weather and Vermin Proof suitably ventilated 440 Volts, 50 Cycles, AC Supply having IP-54 Protection as per IS-2147 of 1962 with Pre-treatment and Powder Coated of approved Colour with Mild Steel Angle Iron 40x40x5.0mm Frame Work/ Supports, grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Formworks, Earth Works, etc., Providng all Electric Connections and Testing, complete all as specified and as directed and Comprising with including to accumodating the followings:-\n(a) Bus-bar in Equal size of Aluminum Conductor with PVC Colored - 01 No. \n Heat Shrinkable type Sleeves Continuous rating of 400 Amp mounted \n on Non-cracking Resin type \n(b) MCCB 320 Amp 4 Pole, 36 kA, 415 Volt, AC - 01 No. \n(c) Digital Amp Meter 0-40 Amp with CTs of suitable ratio & Selector - 01 No.\n Switch\n(d) Digital Volt Meter 0-500 Volt - 01 No.\n(e) Indicating Lamp (RYB), LED type - 01 Set\n(f) Spare Compartment for Future Expansion - 01 No. BI01010001010000000000000515BI0100001120 2 EACH JOB
9 9 Supply, Installation & Commissioning Feeder Pillar Box Factory Made (CPRI approved Manufacturer), made out of 2.0mm thick CRCA Sheet, Indoor type, Weather & Vermin Proof, Front & Rear Openable, Double Doors type, Compart- mentalized design, duly Epoxy Powder coated, complete with Heat Shrink, PVC Gasketed and Sealed, Making All Incoming & Out-going Electrical Cable Connections with Lugs, Glands, etc. and provided at Cable Entries, having insulated Aluminium Bus-bar 400 Amp rating 4 No. provided all Electrical Connections with Aluminium Strips, Danger Notice Plate with Skull & Bone Sign including Mild Steel Channel Frame of ISMC-75 at the Base of Panel and Mild Steel Angle Iron Support 50x50x6.0mm with 50 Cm Height from Ground Level at the base of Panel, grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Form-works, Earth Works, etc., Providng all Electrical Connections and Testing, complete all as specified and as directed and Comprising with including to accumodating the followings:-\nINCOMMING:-\n(a) Copper Bus-bar Strips of suitable size & suitable length of 200 Amp rating \n (03 No.) and 100 Amp (01 No.) for Neutral \n(b) MCCB 125 Amp, 4 Pole, 25 kA with Adjustable Thermal Magnetic - 01 No.\n Release\n(c) Digital Amp Meter 0-400 Amp including Copper wounded CT Coils - 01 No.\n Assembly of suitable ratio and size Class I accuracy, 0.5 VA burden \n and on Site Programmability\n(d) Digital Volt Meter 0-500 Volt, 3 Phase, 4 Digit, high resolution, LED - 01 No.\n type with One Side Programmability\n(e) LED Indicating Lamp (RYB) with Holder Key & Toggle Switch - 03 Set\nOUTGOING:-\n(a) On Load Changeover Switch 63 Amp, 4 Pole, 415 Volt in Open - 01 No.\n Execution Front Operated type for fixing in Panel Board\n(b) MCB TPN 32 Amp, 10 kA with Fixed Thermal Magnetic Release - 01 No.\n(c) MCB TPN 40 Amp, 25 kA with Fixed Thermal Magnetic Release - 01 No.\n(d) Star Delta Starter Open Execution for Submersible Pump 12.5 HP - 01 No.\n(e) Spare Compartment for Future Expansion - 01 No. BI01010001010000000000000515BI0100001121 1 EACH JOB
10 10 Supply, Installation & Commissioning Feeder Pillar Box Factory Made (CPRI approved Manufacturer), made out of 2.0mm thick CRCA Sheet, Indoor type, Weather & Vermin Proof, Front & Rear Openable, Double Doors type, Compart- mentalized design, duly Epoxy Powder coated, complete with Heat Shrink, PVC Gasketed and Sealed, Making All Incoming & Out-going Electrical Cable Connections with Lugs, Glands, etc. and provided at Cable Entries, having insulated Aluminium Bus-bar 400 Amp rating 4 No. provided all Electrical Connections with Aluminium Strips, Danger Notice Plate with Skull & Bone Sign including Mild Steel Channel Frame of ISMC-75 at the Base of Panel and Mild Steel Angle Iron Support 50x50x6.0mm with 50 Cm Height from Ground Level at the base of Panel, grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Form-works, Earth Works, etc., Providng all Electrical Connections and Testing, complete all as specified and as directed and Comprising with including to accumodating the followings:-\nINCOMMING:-\n(a) Copper Bus-bar Strips of suitable size & suitable length of 800 Amp rating \n (03 No.) and 400 Amp (01 No.) for Neutral \n(b) On Load Changeover Switch 200 Amp, 4 Pole 415 Volt in Open - 01 No.\n Execution Front Operated type for fixing in Panel Board\n(c) Digital Amp Meter 0-800 Amp with Copper wounded CT Coils - 01 No.\n Assembly of suitable ratio and size Class I accuracy, 0.5 VA burden\n and on Site Programmability\n(d) Digital Volt Meter 0-500 Volt, 3 Phase, 4 Digit, high resolution, LED - 01 No.\n type with One Side Programmability\n(e) LED Indicating Lamp (RYB) with Holder Key & Toggle Switch - 03 Set\nOUTGOING:-\n(a) On Load Changeover Switch 100 Amp, 4 Pole 415 Volt in Open - 01 No.\n Execution Front Operated type for fixing in Panel Board\n(b) MCB TPN 32 Amp, 10 kA with Fixed Thermal Magnetic Release - 01 No.\n(c) MCB TPN 40 Amp, 25 kA with Fixed Thermal Magnetic Release - 01 No.\n(d) Star Delta Starter Open Execution for Submersible Pump 12.5 HP - 01 No.\n(e) Spare Compartment for Future Expansion - 01 No. BI01010001010000000000000515BI0100001122 1 EACH JOB
11 11 Supply, Installation & Commissioning Feeder Pillar Box Factory Made (CPRI approved Manufacturer), made out of 2.0mm thick CRCA Sheet, Indoor type, Weather & Vermin Proof, Front & Rear Openable, Double Doors type, Compartmentalized design, duly Epoxy Powder coated, complete with Heat Shrink, PVC Gasketed and Sealed, Making All Incoming & Out-going Electrical Cable Connections with Lugs, Glands, etc. and provided at Cable Entries, having insulated Aluminium Bus-bar 400 Amp rating 4 No. provided all Electrical Connections with Aluminium Strips, Danger Notice Plate with Skull & Bone Sign including Mild Steel Channel Frame of ISMC-75 at the Base of Panel and Mild Steel Angle Iron Support 50x50x6.0mm with 50 Cm Height from Ground Level at the base of Panel, grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Form-works, Earth Works, etc., Providng all Electrical Connections and Testing, complete all as specified and as directed and Comprising with including to accumodating the followings:-\nINCOMMING:-\n(a) Copper Bus-bar Strips of suitable size & suitable length of 200 Amp rating\n (03 No.) and 100 Amp (01 No.) for Neutral \n(b) MCCB 200 Amp, 4 Pole, 25 kA with Adjustable Thermal Magnetic - 01 No.\n Release \n(c) Digital Amp Meter 0-400 Amp with Copper wounded CT Coils - 01 No.\n Assembly of suitable ratio and size Class I accuracy, 0.5 VA burden\n and on Site Programmability\n(d) Digital Volt Meter 0-500 Volt, 3 Phase, 4 Digit, high resolution, LED - 01 No.\n type with One Side Programmability\n(e) LED Indicating Lamp (RYB) with Holder Key & Toggle Switch - 03 Set\nOUTGOING:-\n(a) On Load Changeover Switch 63 Amp, 4 Pole 415 Volt in Open - 01 No.\n Execution Front Operated type for fixing in Panel Board\n(b) MCCB 125 Amp, 3 Pole, 25 kA with Adjustable type 160-200 Amp - 01 No.\n Thermal Magnetic Release \n(c) MCB TPN 32 Amp, 10 kA with Fixed Thermal Magnetic Release - 01 No.\n(d) MCB TPN 40 Amp, 25 kA with Fixed Thermal Magnetic Release - 01 No.\n(e) DOL Starter Open Execution suitable for Motor 5 HP - 01 No. BI01010001010000000000000515BI0100001123 1 EACH JOB
12 12 Supply, Installation & Commissioning Feeder Pillar Box Factory Made (CPRI approved Manufacturer), made out of 2.0mm thick CRCA Sheet, Indoor type, Weather & Vermin Proof, Front & Rear Openable, Double Doors type, Compart- mentalized design, duly Epoxy Powder coated, complete with Heat Shrink, PVC Gasketed and Sealed, Making All Incoming & Out-going Electrical Cable Connections with Lugs, Glands, etc. and provided at Cable Entries, having insulated Aluminium Bus-bar 1200 Amp rating 4 No. provided all Electrical Connections with Aluminium Strips, Danger Notice Plate with Skull & Bone Sign including Mild Steel Channel Frame of ISMC-75 at the Base of Panel and Mild Steel Angle Iron Support 50x50x6.0mm with 50 Cm Height from Ground Level at the base of Panel, grouting Legs in Cement Concrete 1:2:4 (20mm graded stone aggregate) Block of size 300x300x450mm including necessary Form-works, Earth Works, etc., Providng all Electrical Connections and Testing, complete all as specified and as directed and Comprising with including to accumodating the followings:-\nINCOMMING:-\n(a) Air Circuit Breaker Thermal Magnetic type with ACB 800 Amp, 50 kA, - 01 No.\n 4 Pole, 415 Volts, 50 Hz for rated Current at Ambient Temperature\n 50°C, conforming to IS:13947 (Part 3, 1993) & IEC\n(b) Digital Volt Meter 0-500 Volt with Selector Switch - 01 No.\n(c) Multi-Function Digital Energy Meter with RS-485 Communication - 01 No.\n cation Port with CTs\n(d) CT Coils of suitable ratio - 01 Set\n(e) Phase Indicating Lamp Assembly - 01 Set\nOUTGOING:-\n(a) MCCB 200 Amp, TPN, 36 kA, 415 Volt, 50Hz with Thermal Magnetic - 05 No.\n Release, Ics =100% Icu, Front Face Isolataion with Positive Break\n indication with Double Break Contacts with Spreader and Phase Barrier\n(b) Spare Compartment for Future Expansion - 01 No. BI01010001010000000000000515BI0100001124 1 EACH JOB
13 13 M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Old Unserviceable Earthing of any description (08 No.), complete all as per specified and as directed. \nNOTE : All Joints should be joined by Exothermic Welding or Brazing. BI01010001010000000000000515BI0100001125 12 EACH SET