| 1 | 1 | CONSTRUCTION OF LIVELIHOOD BUSINESS INCUBATION CENTER AND BAMBOO BAZAAR - KOTHAMANGALAM | | | |
|---|
| 2 | 1.01 | 2.6.1.Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil. | | 129.65 | cum |
|---|
| 3 | 1.02 | 4.1.8.Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size). | | 5.5 | cum |
|---|
| 4 | 1.03 | 5.1.2.Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: \n1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size | | 18.87 | cum |
|---|
| 5 | 1.04 | 5.3.Reinforced cement concrete work in columns, beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size). | | 68.31 | cum |
|---|
| 6 | 1.05 | 5.22.6.Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level \nThermo - Mechanically Treated bars of grade Fe-500D or more | | 2075.15 | kg |
|---|
| 7 | 2 | 5.22A.6.Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more | | 7514.16 | kg |
|---|
| 8 | 3 | 5.9.1.Centering and shuttering including strutting, etc. and removal of form for:\nFoundations, footings, bases of columns, etc for mass concrete | | 102.5 | sqm |
|---|
| 9 | 4 | 5.9.3.Centering and shuttering including strutting, etc. and removal of form for:\nSuspended floors, roofs, landings, balconies and access platform | | 396.34 | Nos |
|---|
| 10 | 5 | 5.9.5.Centering and shuttering including strutting, etc. and removal of form for:\nLintels, beams, plinth beams, girders bressumers and cantilevers | | 229.1 | sqm |
|---|
| 11 | 6 | 5.9.6.Centering and shuttering including strutting, etc. and removal of form for:\nColumns, Pillars, Piers, Abutments, Posts and Struts | | 150.7 | sqm |
|---|
| 12 | 7 | 5.9.7.Centering and shuttering including strutting, etc. and removal of form for:\nStairs, (excluding landings ) except spiral - staircases) | | 60 | sqm |
|---|
| 13 | 8 | 11.3.1.Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate)finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.\n40 mm thick with 20 mm nominal size stone aggregate | | 85.63 | sqm |
|---|
| 14 | 9 | 50.2.25.1.Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge | | 38.53 | cum |
|---|
| 15 | 10 | 50.6.1.5.Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete | | 67.46 | cum |
|---|
| 16 | 11 | 50.6.1.6.Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete | | 8.46 | cum |
|---|
| 17 | 12 | 50.6.2.2.Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete | | 34.88 | cum |
|---|
| 18 | 13 | 13.1.1.Providing & applying plastering in 12mm thick with cement mortar 1:4 for walls ,columns ,beams and compound wall etc .including chipping concrete surface if required ,finishing ,scuffolding ,curing etc complete | | 1478.43 | sqm |
|---|
| 19 | 14 | 11.38.Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc.,(IN TOILET AREA ONLY) complete. | | 38.64 | sqm |
|---|
| 20 | 15 | 11.39.Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS: 15622, of approved make in colours White, Ivory, Grey, fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., (Double charged tiles) complete./bamboo flooring tiles supplied by us | | 253.53 | sqm |
|---|
| 21 | 16 | 11.36.Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.(Toilet area only) | | 100.15 | sqm |
|---|
| 22 | 17 | 17.2.1.Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:\nW.C. pan with ISI marked white solid plastic seat and lid | | 9 | Nos |
|---|
| 23 | 18 | 17.7.4. Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:\nWhite Vitreous China Flat back wash basin size 550x400mm with single 15 mm C.P.brass pillar taps | | 6 | Nos |
|---|
| 24 | 19 | 17.23.Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. | | 3 | Nos |
|---|
| 25 | 20 | 17.31.Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | | 6 | Nos |
|---|
| 26 | 21 | 50.18.9.20.7.Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl | | 4 | Nos |
|---|
| 27 | 22 | 50.18.9.19.1.Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall | | 12 | m |
|---|
| 28 | 23 | 50.18.9.9.1.Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 | | 15 | m |
|---|
| 29 | 24 | 50.18.9.17.1.Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall | | 45 | m |
|---|
| 30 | 25 | 50.18.9.16.2 .Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wal | | 45 | m |
|---|
| 31 | 26 | 50.18.8.4.1.Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 | | 45 | m |
|---|
| 32 | 27 | 50.18.8.3.2.Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2 | | 45 | m |
|---|
| 33 | 28 | 50.18.8.2.2.Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 | | 45 | m |
|---|
| 34 | 29 | Providing and fixing good quality PVC floor trap with gratings | | 12 | Nos |
|---|
| 35 | 30 | 50.17.1.4.Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. | | 9 | Nos |
|---|
| 36 | 31 | 50.17.1.3.Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. | | 4 | Nos |
|---|
| 37 | 32 | 50.17.1.1.Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge | | 6 | Nos |
|---|
| 38 | 33 | 18.52.1.Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 8931\n15 mm nominal bore | | 5 | Nos |
|---|
| 39 | 34 | 18.51.1.Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.\n15 mm nominal bore | | 10 | Nos |
|---|
| 40 | 35 | 18.53.1. Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 8931\n15 mm nominal bore | | 9 | Nos |
|---|
| 41 | 36 | 18.22.2.Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:\n150 mm diameter | | 4 | Nos |
|---|
| 42 | 37 | 51.19.ST3.Supplying and installing ready made PVC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately)\n3. 25 to below 35 flush capacity | | 1 | Nos |
|---|
| 43 | 38 | 18.48.Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | | 2000 | Nos |
|---|
| 44 | 39 | 19.30.1.1.Constructing brick masonry chamber for underground C.I. inpection chamber and bends with bricks in cement mortar 1:4 ( 1 cement: 4 coarse sand) C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg), R.C.C top slab with 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:\nInside dimensions 455x610 mm and 45 cm deep for single pipe line:\nWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | | 2 | Nos |
|---|
| 45 | 40 | Providing and fixing factory made door frame and 30mm thick door shutter made of solid PVC foam profile .fraem will be milted & jointed with self driven self tapping screws of size 38 mm X 4 mm & PVC solvent cement,including fixing the frame to wall with suitable dia & length anchor fastener as per manufactures specification after dismantling the existing door frame & shutters .single piece extruded solid PVC lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of siz 100mm X 8mm ,fitting tower bolt,door handle /Aldrops and all other fittings as per the standerd specifications and directions of officers | | 12 | Nos |
|---|
| 46 | 41 | 10.6.2.Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.\n80x1.20 mm M.S. laths with 1.20 mm thick top cover | | 42.9 | Sqm |
|---|
| 47 | 42 | Suppling and fixing hand rails for stairs and balconies using 304 grade stainless steel tubes per the direction of site Engineer-in-charge | | 40.63 | m |
|---|
| 48 | 43 | 21.1.1.2.Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):\nFor fixed portion\nPowder coated aluminium (minimum thickness of powder coating 50 micron) | | 67.5 | Kg |
|---|
| 49 | 44 | 21.3.1.Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness | | 22.5 | Sqm |
|---|
| 50 | 45 | 50.9.1.1.Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length , using good quality Anjili wood /jack wood | | 0.15 | m3 |
|---|
| 51 | 46 | 50.9.4.1.Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Anjili/ Jack wood | | 6 | Sqm |
|---|
| 52 | 47 | 9.97.2.Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:\n250x10 mm | | 8 | Nos |
|---|
| 53 | 48 | 9.103.Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete. | | 4 | Nos |
|---|
| 54 | 49 | 9.66.1.Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screws etc. complete:\n125 mm | | 8 | Nos |
|---|
| 55 | 50 | 13.43.1.Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:\nWater thinnable cement primer | | 1478.43 | sqm |
|---|
| 56 | 51 | 13.44.1.Finishing walls with water proofing cement paint of required shade:\nNew work (Two or more coats applied @ 3.84 kg/10 sqm) | | 1478.43 | sqm |
|---|
| 57 | 52 | 13.61.1.Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:\nTwo or more coats on new work | | 15 | sqm |
|---|
| 58 | 53 | 16.68.Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. | | 80.1 | sqm |
|---|
| 59 | 54 | Electrification(lump-sum as per the drawing) | | 1 | LS |
|---|