Repair / Replacement And Maint Of External Lt Network Including Lt Equipments And Allied Works At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala, GE Kapurthala-Punjab

Military Engineer Services-MES has published Repair / Replacement And Maint Of External Lt Network Including Lt Equipments And Allied Works At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala. Submission Date for this Tender is 23-03-2021. Electrical Products Tenders in GE Kapurthala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

27253426
Corrigendum : Repair / Replacement And Maint Of External Lt Network Including Lt Equipments And Allied Works At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala
Open Tender
Indian
Punjab
GE Kapurthala
23-03-2021

Tender Details

Repair / Replacement And Maint Of External Lt Network Including Lt Equipments And Allied Works At Mil Stn Beas And Jandiala Guru Under Ge Kapurthala-1. Power Transformers 132 / 66 / 33 / 22Kv 2. Distribution Transformers 11 Kv Above 500 Kva Capacity 3. Distribution Transformers Upto 500 Kva Capacity 4. Chemical Earthing 5. Star Rated Energy Efficient Step Down Transformers Upto 200 Kva Capacity ( 4 / 5 Star Rating Only To Be Used ) 6. Ht Switch Gear 132 / 33 Kv & 66 Kv, Vcb ( Out Door / Indoor ) / Ct & Pt 7. Ht Switch Gear 33 / 66 Kv, Sf6 ( Out Door / Indoor ) 8. Ht Switch Gear 11 Kv, Vcb ( Indoor / Out Door ) , Ht Ring Main Unit, Sf6 / Vacuum, 11 Kv / Ct & Pt 9. Ht Switch Gear Protection Relays ( Electromechanical / Numerical ) 10. Package / Unified Sub- Station Abb, Schneider, Voltamp, 11. Lt / Ht Cable Joints Heat Shrinkable / Cold Shrinkable / Push On Type Denson, Raychem, 12. Gang Operated Switch Device Abb, 13. Lightening Arrestor Bhel, Greaves, Pactil, Electrical, 14. Ht / Lt Pcc Poles Cement Concrete Chandigarh, Cement, Lucknow, 15. Ct & Pt, 11 & 33 Kv Abb, Ae, Kappa Panel 16. Ht Xlpe Cables 132 / 66 / 33 Kv & 11 Kv Cci, Finolex, Industires 17. Ht / Lt Steel Tubular Swaged Poles National Kanpur, Steel Electric 18. Steel Tubular Decorative Pole Octagonal / High Mast Light And Poles Finolex, Crompton Electric, 19. Lt Panels / Apfc Panels / Ac Control Panels / Pump House Panels For Ss Siemens, Schnieder, 20. High Voltage Insulating Rubber Mat Jyoti, 21. Lt Air Circuit Breakers Abb, Schneider, Alstom, 22. Mccb‟S Abb, Schneider, Merlin Benlo 23. Mcb / Elcb / Rccb / Rocb / Isolators / Mcb Dist Boards L& Siemens, Benlo, 24. Power Contactors L& Siemens, Power 25. Voltmeter / Ammeter / Frequency Meter / Pf Meter ( Analog Type ) Ae, Legrand, 26. Voltmeter / Ammeter / Frequency Meter / Pf Meter ( Electronic Type / Digital Type ) Secure, ( Rishabh ) , C& 27. Lt Cables, 1100 Volts, Xlpe Cci, Cables, Industries Rallison 28. Pcc Cable Covers Mehtab 29. Change Over Switches Siemens, Schneider 30. Smart / Tamper Proof Energy Meters Abb, Schenider, 31. Voltage Stabilizers Upto 25 Kva Ae, Yule, 32. Voltage Stabilizers Above 25 Kva ( Servo Controlled ) Ae, Yule, 33. Ups ( Off Line & On Line Emerson, Libert, 34. Dg Sets ( I ) Engine ( Ii ) Alternator Cotton Cummins, Caterpillar Bharat Kirloskar Volvo, 35. Dg Set Integrator Akson, Mahindra, Kirloskar 36. Lt Capacitor Banks 37. Ht Capacitor Banks 38. Pvc Rigid Conduit 39. Ms Conduit / Erw Conduit Pipe 40. Pvc Copper Wires 650 / 1100 Volts 41. Pt Switch / Sockets / Ceiling Roses / Fan Regulators 42. Laminated Sheet Cover 43. Modular Switches / Sockets / Fan Regulators 44. Street Light Fittings Accessories– Hpsv ( 70 / 150 / 250 / 400 ) , Hpmv– ( 80 / 125 / 250 / 400 ) / Metal Halide 45. Tube Light / Street Light Fittings 46. Flood Light Fittings 47. Acsr Conductor 48. Box Type Decorative Light Fittings 49. Cfl Fittings 50. Cfl Lamps 51. Led Lamps 52. Sk Fittings 53. Ceiling Fans / Exhaust Fans / Wall Mounted Fans / Air Circulators ( Only 5 Star Bee Rating Fans Shall Be Provided ) 54. Water Heaters ( Only 5 Star Bee Rating Water Heaters Shall Be Provided ) 55. Bus Bar Trunking Systems 56. Battery Charger 57. Lead Acid Batteries 58. Led Light Fittings 59. Flame Proof Switches / Sockets / Db‟S 60. Flame Proof Light / Fittings 61. Flame Proof Exhaust Fans / Pedestal Fans / Flame Proof Ac 62. Solar Street Light Fittings 63. Street Lifgt Timers 64. Aviation Obstruction Light 65. Transformer Oil 66. Gi Pipes / Ms Pipes 67. Hdpe / Upvc / Ppr Pipes 68. Ci Pipes 69. Di Pipes 70. Sluice Valves / Non Return Valves / Air Release Valves 71. Butterfly Valve / Check Valves 72. Gun Metal Globe Valve 73. Gi Fittings 74. Pump Sets- Mono Block 75. Centrifugal Pumps 76. Submersible Pumps 77. Non Clog Sewage Pumps 78. Vertical Turbine Pumps 79. Dosing Pump / Bleaching Dozer 80. Motor Starters 81. Electric Motor 82. Single Phase Preventors / Phase Sequence Corrector 83. Lifts / Elevators

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 16-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 60400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Repair/replacement & maint of external LT network including LT equipments and allied works at Mil Stn beas and Jandiala Guru under GE Kapurthala
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out old cable/laying of under ground cable/foundation of poles/stays including segregation of old serviceable bricks complete all as specified and directed by Engineer-in-Charge. 459 Cum
2 2 Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge. 265 Cum
3 3 Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. 194 Cum
4 4 M & L for brick protection using old size sub class 'B' bricks, laid flat dry but adjoining to each other laid lengh wise perpendicular to the axis of cable complete all as specified and directed. 13.5 Per 1000 Nos
5 5 Supplying, filling in trenches spreading, leveling sand cushioning 8 cm below and 15 cm above the cable for under ground cable complete all as specified & directed. Note:- Depth after punning down 18 cm shall be measured recorded for payment purpose 137 Cum
6 6 Supply laying, commissioning and testing XLPE insulated armoured heavy duty, electric cable with aluminium stranded conductor for working 1100 Voltage grade size 2 core, 10 sqmm including taking out existing unserviceable cable complete all as specified and directed (Earth work, sand cushioning and brick protection shall be measured and paid for separetaly). 300 RM
7 7 All as per item ser No 6 above here in before but 16 sqmm 2 Core 300 RM
8 8 All as per item ser No 6 above here in before but 16 sqmm 4 Core 250 RM
9 9 All as per item ser No 6 above here in before but 3.5 core 25 sq mm 250 RM
10 10 All as per item ser No 6 above here in before but 3.5 core 50 sq mm 250 RM
11 11 All as per item ser No 6 above here in before but size 3.5 core 70 sq mm 300 RM
12 12 All as per item ser No 6 above here in before but size 3.5 core 95 sq mm 400 RM
13 12.01 Note for Ser Item No 6 to 10 : Contractor will deposit old retrievd unsv XLPE LT Cable to MES Store Yard and will be taken on ledger charge as salvage.
14 13 Supply and layng in replacement GI pipe light grade 40 mm bore for cable porotection fixed to poles/along wall/floor/under road/preparation of GI bracket etc across the drain or nallah with clamps. Bolts, nuts & washers etc complete all as specified including taking down the old unsv (clamps. Bolts, nuts & washers shall be measured and paid seperatly) 30 RM
15 14 Ditto all as per item No 13 above but of 80 mm dia 20 RM
16 15 Supply and erect in truly vertical position pretressed concrete pole 9.0 mtr long 102mm x 172mm at top and 102 mm x 279mm at bottom, class 10 including painting of pole upto 1.5 mtr height from coping of pole with synthetic enamelled paint black & White strips each of 30 cm height complete all as specified and directed including taking out the old unservicebale one.(Excavation, earth work, PCC shall be measured & paid seperatly) 10 Each
17 16 Supply and Fixing in replacement, shackle type porcelain vitrous white, green or brown insulators for working pressure 1100 volts grade 90 mm dia x 75 mm height including galvanised MS straps, washers, insulator bolts, washers & nuts complete all as specified and directed.complete all as specified. 50 Each
18 17 Supply & fixing in replacement pin type porcelain, vitrous white, brown insulator including one galvanised MS spindle and two galvanised iron washers and one galvanised MS nut, 100 mm height 65 mm dia for 1100 volt grade complete all as specified and directed. 50 Each
19 18 Taking down unserviceable MCB’s and S&F MCB 63 Amp, TPN 240 volts Make : Havells/L&T/Indo Asian/Schnider/C&S or equivalent 5 Each
20 19 S & F Sintex make PVC looping box comprising of 04 Nos Aluminimum bus bar mounted on insulator and one No 06 Amps SP MCB complete with necessary fixing arrangement , clamps, nuts bolts etc on pole including taking down the old unserviceable existing DB/looping box all as specified and directed with necessary 150 Each
21 20 M & L for wiring for Circuit from MCB box to Street light including supply and fixing (with suitable clamp) of pvc conduit of size 20 mm dia on pole with FR PVC insulated copper conductor single core cable with 2 x 2.5 sqmm + 1 x 1.5 sqmm earth wire in surfaces/recessed as required and as directed. Note:- Two run of cable 2.25 sqmm, one run of cable 1.5 sqmm & one run of PVC conduit to gether shall measured as one unit of RM. 250 RM
22 21 Supply fabricate and fixing in replacement GI bracket made out of galvanised pipe light grade 32 mm dia 1.5 Mtr long bent to shape for fixing of security light and all as specified and directed. 50 Each
23 22 Supply and fix in replacement of old unserviceable T5/HPSV/HPMV/FTL street light with 45 Watt LED STREET LIGHT - INDUS-i SERIES fitting Powder coated pressure die cast aluminium SMD LED Street light with heat resistant toughened glass. Product Code - INDUS-i/45W Cat Part No LTESSI45WLED Make- C&S or equivalent in Bajaj/Philips/Havells/Crompton (Contractor will provide 1 Years warranty for repair/replacement of fittings and driver etc) 45 Each
24 23 Supply and fix in replacement of old unserviceable T5/HPSV/HPMV/FTL street light with 60 Watt LED STREET LIGHT - INDUS-i SERIES fitting Powder coated pressure die cast aluminium SMD LED Street light with heat resistant toughened glass. Product Code - INDUS-i/60W Cat Part NoLTESSI60WLED Make- C&S or equivalent in Bajaj/Philips/Havells/Crompton (Contractor will provide 1 Years warranty for repair/replacement of fittings and driver etc) 42 Each
25 24 Supply and fix in replacement of old unserviceable T5/HPSV/HPMV/FTL street light with 30 Watt LED STREET LIGHT - INDUS-i SERIES fitting Powder coated pressure die cast aluminium SMD LED Street light with heat resistant toughened glass. Product Code - INDUS-i/30W Cat Part No LTESSI30WLED Make- C&S or equivalent in Bajaj/Philips/Havells/Crompton (Contractor will provide 2 Years warranty for repair/replacement of fittings and driver etc) 45 Each
26 25 S & F in replacement bus bar chamber panel LT out door cubical type, single door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 30mm x 50mm x 6 mm of size 600mm x600mm x 300mm with removable hinged doors on both side, locking arrangement, verin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide including foundation suitable for 440 V, 3 phase, 50 Hz comprising of the following fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation and painted internal and external surfaces with grey enamelled paint over a coat of red oxide complete all as specified and comprising the following. 4 Each Job
27 25.01 (a) Bus bar chamber having 04 strip of copper bus bars of 200 Amp
28 25.02 (b) MCCB 4 Pole 63 Amp 25 KA-01 No
29 25.03 (c) MCB SPN-04 Nos Make- Legrand/ Schnider/C&S/L&T
30 26 M & L for PCC 1:4:8 type D-2 (Using stone aggregate 40 mm graded) as in base fouundation for electric poles including necessary form work where required and fair finish to the exposed surfaces complete all as specified and directed. 2 Cum
31 27 Ditto all as per item No 26 here-in-before but PCC 1:3:6 type C-2 (Using 40mm graded stone aggregates) as in main foundation of stays and poles and coping of poles. 7 Cum
32 28 M&L in replacement ACSR conductor of any size including binding on existing LT poles or new poles with 2 mm dia aluminium binding wire complete including dismantling/taking down of old unserviceable ACSR conductor all as specified and directed. (Squirrel/Weasel type ACSR to be used) 12 Quintal
33 29 Fabricating,supply and fixing in replacement cross arms (any type) supports bracing, stiffeners anticlimbing spikes etc made out of MS, MS channel, angle iron, flat of any size including drilling of holes, making of clamps, nut, bolts etc including painting with two coat of aluminium paint over a coat of red oxide primer after preperation of surface to all steel and iron surfaces complete all as specified and as directed by Engr-in-charge. 3 Quintal
34 30 Supply and Fixing in replacement, lightning arrester for out door use non-linear resister type horn gap and chocking coil for working pressure 1100 volt, 30 KA,complete including nuts, bolts, clamps, bracket etc and connecting with GI earth wire, complete all as specified and directed. Make : Alstom/ Oblum 2 Set of three
35 31 Supply and fixing in replacement of Danger Notice Plate of size 20 x 15 cm and of 1.6 mm thick mild steel sheet vitreous enameled white, with letters figures (In English, Hindi & Punjabi) and conventional skull and bones in signal red colour and fixing arrangement for LT complete all as specified and directed. 80 Each
36 32 Supply and fixing in replacement of MCCB, 4 pole, 415 volt of cpacity. Adjustable type 160 Amp, short circuit breaking capacity 35/36 KA, thermal setting 70-100% confirming to IS, including thimbles, nuts, bolts, washers etc disconnecting from LT panel and making incoming, out going connections complete all as specified and directed. (Cost of copper thimbles, nut & bolts shall be included in the quoted rate) Make : HAVELLS/C&S/Legrand/L&T/Indo Asian/ HPL 4 Each
37 33 Ditto all as per item No 32 above but of cap 200 Amps and breaking capacity 35/36 KA and thermal setting 5 to 10 times. 3 Each
38 34 Ditto all as per item No 32 above but of cap 250 Amps and breaking capacity 35/36 KA and thermal setting 5 to 10 times. 3 Each
39 35 Ditto all as per item No 32 above but of cap 300-350 Amps and breaking capacity 35/36 KA and thermal setting 5 to 10 times. 2 Each
40 36 Ditto all as per item No 32 above but of cap 400 Amps and breaking capacity 35/36 KA and thermal setting 5 to 10 times. 2 Each
41 36.01 Note for Item No 32 to 36 : Contractor will provide MCCBs as per site requirement/design of LT Panel (as per Make,model, type of existing MCCBs) for proper housing of MCCBs in existing LT Panels)
42 37 M & L for providing earthing in replacement earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level connected to GI earth wire 4mm dia by means of bolts, nuts and washers (earth plate covered with charcoal dust and common salt in alternate layers) GI earth wire protected by galvanized steel pipe light grade of 15 mm bore upto 5 mtr and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shawn in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indiated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCC covered with CI cover hinged with frame including excavation and earth work complete all as specified. 10 Each set
43 38 M & L for providing earthing in replacement earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level covered on all sides with alternative layers of charcol dust and common salt 15 cm thick connected to galvanised earth lead Galvanised Iron strip 32 x 6 cm by means of bolts, nuts, check nuts and washers of Galvanised Iron or steel with protection pipe earth wire protected by galvanized steel pipe light grade 40 mm bore from top of the earth plate electrode upto test point and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shawn in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indiated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCC covered with CI cover hinged with frame including excavation and earth work complete all as specified. 10 Each Job
44 39 Supply and fix in replacement cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable of size 25 to 50 sq mm indoor/outdoor type all as specified and directed by Engr in Charge 2 Each
45 40 Ditto all as per item No 39 above but for cable of size 70 to 95 sq mm. 2 Each
46 41 Ditto all as per item No 39 but for cable of size 120 to 150 sq mm. 2 Each
47 42 Ditto all as per item No 39 but for cable of size 185 to 240 sq mm. 2 Each
48 43 Ditto all as per item No 39 but for cable of size 300 to 400 sq mm. 2 Each
49 44 M & L for unbinding from insulators the ACSR conductor on pole and restretching the loose ACSR conductor of any size on LT poles and binding the same with 2 mm dia new alumunium binding wire complete all as specified and directed. 5000 RM
50 45 Labour only for cutting/pruning of tree branches 1.5 mtr all around the LT overhead lines of span n.exc 40 mtr and around the pole obstruction the overhead line & removing the branches to distance n.exc 50 mtr to be the entire satisfaction of Engineer-in-charge, 100 Each Span of 30 Mtrs
51 46 Labour only by providing a trained electrician with helper for servicing, repair/maint, replcement of unservicable components like changeover, MCCBs, Volt meter, Ammeter etc , cutting/drilling/welding wk etc ,replacement of copper/alumn bus bar , thimbles, changing of connection copper wire lead etc all as specified and directed by Engr in Charge. \n(The job under item No 46, also includes labour for replacement of electrical fittings/fixturesas per Sl No 46.1 to 46.9 component in existing LT Panel Boards including disconnecting and taking down the UNSV components at different locations all as specified and directed by Engr in Charge :- (Items used will be measured and paid separately as mentioned below (a) to (k) 30 Each Job
52 46.01 (a) Aluminium thimbles or lugs 35 sqmm 75 Each
53 46.02 (b) Aluminium thimbles or lugs 50 sqmm 75 Each
54 46.03 (c) Aluminium thimbles or lugs 70 sqmm 75 Each
55 46.04 (d) Aluminium thimbles or lugs 95 sqmm 75 Each
56 46.05 (e) Aluminium thimbles or lugs120 sqmm 50 Each
57 46.06 (g) Voltmeter Digital type ,0-500 Volts 4 Each
58 46.07 (h) Ammeter Digital type of 400 amps capacity 4 Each
59 46.08 (j) Selector switch for voltmeter 4 Each
60 46.09 (k) Selector switch for Ammeter 4 Each
61 47 M&L for cleaning and preparation of old painted surface of HT/LT PCC pole 9/ 11 mtr long and painting with one coat of marking 30 cm high alternate black & white strips with synthetic enameled paint up to 1.5 mtr height and writing pole Nos and applying one coat of cement base paint on PCC coping complete all as specified and directed by Engr in Charge 200 Each\nJob
62 48 M&L for preparation of old painted steel pole of 9 m long and painting with two coats of aluminium paint from top of the pole to 1.5 m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer upto 1.5m from bottom of the pole complete all as specified and directed 100 Each
63 49 Taking down existing old unserviceable LT panel and supply, fabricating, installation, commissioning, testing and electrically connected CPRI approved manufacturer LT panel out door cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 50mm x 50mm x 6 mm of size 1.5m x1.5 m x.0.50 m with removable hinged doors on both side, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal& external surface) with heat shrinkable sleeves on Copper bus bar 400 Amp capacity - 04 Nos for distribution, complete wiring with thimbles and other accessories using crimping tool including foundation for fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation complete all as specified and directed by Engr in Charge comprising the following :- 1 Each Job
64 49.01 Note: All MCCB must have the provision of load setting.
65 49.02 Incoming.
66 49.03 (i) MCCB 400 Amps 36KA, 4 pole 415 volts , 50 C/S with spreader link - 01 Nos Make : Schneider/L&T/Legrand
67 49.04 Outgoing
68 49.05 (i) MCCB 250 Amps 25 KA, 4 pole 415 volts , 50 C/S - 03 Nos with spreader link Make : Schneider/L&T/Legrand
69 49.06 (ii) MCCB 100 Amps 25KA, 4 pole 415 volts , 50 C/S - 02 Nos with spreader link Make : Schneider/L&T/Legrand
70 49.07 (iii) Indicating lamps, LED type, 230VAC - 3Nos.
71 49.08 (iv) Digital Voltmeter , 3Phase -01 Nos
72 49.09 (v) Digital Ammeter 3Phase - 1 Nos
73 49.1 (vi) CT coils - 3 Nos.
74 50 Taking down existing old unsv LT panel and supply, fabricating, installation, commissioning, testing and electrically connected CPRI approved manufacturer LT panel out door cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 50mm x 50mm x 6 mm of size 1.5m x1.1 m x.0.50 m with removable hinged doors on both side, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal& external surface) with heat shrinkable sleeves on Copper bus bar 400 Amp capacity - 04 Nos for distribution, complete wiring with thimbles and other accessories using crimping tool including foundation for fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation complete all as specified and directed by Engr in Charge comprising the following :- 1 Each Job
75 50.01 Note: All MCCB must have the provision of load setting.
76 50.02 Incoming.
77 50.03 (i) MCCB 315 Amps 35KA, 4 pole 415 volts , 50 C/S with link - 01 Nos Make : Schneider/L&T/Legrand
78 50.04 Outgoing
79 50.05 (i) MCCB 250 Amps 25 KA, 4 pole 415 volts , 50 C/S with link - 02 Nos Make : Schneider/L&T/Legrand
80 50.06 (ii) MCCB 100 Amps 25KA, 4 pole 415 volts , 50 C/S with link - 03 Nos Make : Schneider/L&T/Legrand
81 50.07 (iii)Indicating lamps, LED type, 230VAC - 3Nos.
82 50.08 (iv) Digital Voltmeter , 3Phase -01 Nos (v) Digital Ammeter 3Phase - 1 Nos (vi) CT coils - 3 Nos.
83 51 Taking down existing old unsv LT panel and supply, fabricating, installation, commissioning, testing and electrically connected CPRI approved manufacturer LT panel out door cubical type, Double door, made of 3.15 mm thick CRCA sheet steel on angle iron frame 50mm x 50mm x 6 mm of size 1.5m x1.2 m x 0.50 m with removable hinged doors on both side, locking arrangement, vermin proof, painted with 2 coats of synthetic enamel paint over a coat of red oxide (internal& external surface) with heat shrinkable sleeves on Copper bus bar 400 Amp capacity - 04 Nos for distribution, complete wiring with thimbles and other accessories using crimping tool including foundation for fixing over PCC (1:2:4) type B-1 using 20mm graded stone aggregate foundation complete all as specified and directed by Engr in Charge comprising the following :- 1 Each Job
84 51.01 Note: All MCCB must have the provision of load setting.
85 51.02 Incoming.
86 51.03 (i) MCCB 315 Amps 36 KA, 4 pole 415 volts , 50 C/S with Link - 01 Nos Make : Schneider/L&T/Legrand
87 51.04 Outgoing
88 51.05 (i) MCCB 250 Amps 25 KA, 4 pole 415 volts, 50 C/S with Link- 01 Nos Make : Schneider/L&T/Legrand
89 51.06 (i) MCCB 125 Amps 25 KA, 4 pole 415 volts, 50 C/S with Link - 01 Nos Make : Schneider/L&T/Legrand
90 51.07 (iv) Indicating lamps, LED type, 230VAC - 3Nos. (v) Digital Voltmeter , 3Phase -01 Nos(vi) Digital Ammeter 3Phase - 1 Nos (vii) CT coils - 3 Nos.
91 52 Dismantling and taking down only existing ACSR conductor of any size/type from LT electric pole with the help of suitable T&P and proper safety gears to clear the disturbed area due to wind/storm complete all as specified and directed by Engr in Charge 3 Qtl
92 53 Dismantling and taking out/ down old existing broken/ deshaped LT PCC poles 9 mtr including insulators from site by means of JCB/ Hydra machine/Typhor or suitable T&P with proper safety arrangements, providing proper stay wires etc to avoid damage to others poles/span of ACSR including depositing/collecting the pole a side in a proper way complete all as specified and directed by Engr in Charge. (Items includes dismantling of 4/2 pole structure also) 10 Each Pole
93 54 M&L for repalcement of Stay assembly comprising of GI stay bow 14 mm dia, 40 cm long (over all) galvanized steel stay rod 20 mm dia, 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30cmx30cmx6mm complete all as specified and directed. 5 Each set
94 55 Supply & Replacement of stay wire standard of 7/4 mm of GI wire complete all as specified and directed by Engineer-in-Charge. 0.5 Qtl
95 56 Supply & Replacement of loop type insulators, vitreous porcelain brown or green large size with over all dimension 90 x 140 mm clearance of hole 25.5 mm all as specified. 6 Each
96 57 M&L for repair/maint/servicing/overhauling of Servo Voltage stabilizer (AVR) 50-75 KVA Capacity by service engineer of authorised dealer includes cleaning of tank, dehydration of transformer oil, refilling of transfrmer oil including top up the tank, replacement of spares such as Voltmeter, Ammeter, selector switch etc. The contractor will arrange suitable T&P for dehydration of oil, and opening lifting of coils of stablizer though chain pullely tripod etc . Spares will be measured and paid separately vide item No 57.1 to 57.5 below as supply only. 2 Each Job
97 57.01 (a) Supply only Controller (PCB) of AVR 2 Each
98 57.02 (b) Supply only Synchronising Motor suitable for 50-75 KVA Servo Voltage Stabilizer 2 Each
99 57.03 (c) Supply only Dimmer stat suitable for 50-75 KVA Servo Voltage Stabilizer 1 Each
100 57.04 (d) Supply only Voltmeter 0-500 V 2 Each
101 57.05 (e) Supply only Ammeter 0-100 Amp 2 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail