}

Modification Work In Lpg Pipeline And Providing Earthing Interlock System For Lpg Tank Lorry Filling/Unloading Bays At Lpg Bottling Plants Of Indian Oil Aod State Office . , LPG BOTTLING PLANTS OF IOAOD SO, IOCL-Assam

Indian Oil Corporation Limited-IOCL has published Modification Work In Lpg Pipeline And Providing Earthing Interlock System For Lpg Tank Lorry Filling/Unloading Bays At Lpg Bottling Plants Of Indian Oil Aod State Office . . Submission Date for this Tender is 22-03-2021. Gas Pipe Line Tenders in LPG BOTTLING PLANTS OF IOAOD SO, IOCL Assam. Bidders can get complete Tender details and download the document.




Tender Notice

27231190
Corrigendum : Modification Work In Lpg Pipeline And Providing Earthing Interlock System For Lpg Tank Lorry Filling/Unloading Bays At Lpg Bottling Plants Of Indian Oil Aod State Office .
Open Tender
Indian
Assam
LPG BOTTLING PLANTS OF IOAOD SO, IOCL
22-03-2021

Tender Details

Modification Work In Lpg Pipeline And Providing Earthing Interlock System For Lpg Tank Lorry Filling/Unloading Bays At Lpg Bottling Plants Of Indian Oil Aod State Office .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Mar-2021 Reply to mailed clarification Technical Bid 22-03-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Modification work in LPG pipeline and providing earthing interlock system for LPG tank lorry filling/unloading bays at LPG Bottling Plants of Indian Oil AOD State Office.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Part A: Supply and Erection: North Guwahati IOAODTLD0001
2 2 Supply of Ex Proof Resistive Capacitive type earthing relay of approved make as per technical specifications mentioned in the tender document in PESO / CCOE approved FLP enclosure for usage in Zone 1 (Hazardous Area Classification as per IS 2148).\nFlameproof cum weather proof smart type Grounding unit (Resistive Capacitive type earthing relay) shall have Red and Green indicating lamps and dual output for safety earthing of tank trucks, suitable for giving safety\ninterlocking signal as per specifications and datasheet. IOAODTLD0002 16 each
3 3 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables.4Cx2.5 sqmm (2XWY) for Power / Signal IOAODTLD0003 450 RM
4 4 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables1Cx16 (A2XY) (Aluminum) for earthing IOAODTLD0004 240 RM
5 5 Supply of 4 way FLP JBs of approved make duly approved by PESO for usage in Hazardous Area - Zone I with PESO Approved FLP Glands of suitable size, complete as required for termination of cable inside the JBs. These JBs to be installed at each bay of TLD for incoming supply to earthing relays from header cable. IOAODTLD0005 16 each
6 6 Supply of GI Cable trays of size: 100 mm width IOAODTLD0006 60 RM
7 7 Supply of GI Cable trays of size:200 mm width IOAODTLD0007 60 RM
8 8 Supply of ROV(Ball Valve + Pneumatic Actuator + Solenoid Valve + Required accessories), 2" 300# RF, A216 WCB, SS316 Ball material, Wetted parts: SS316, Class VI, Fire safe, hand wheel, 1 SOV, 1 AFR as per specifications and data\nsheets given. IOAODTLD0008 32 Each
9 9 Supply of WNRF A 105 CS 300# Sch 80 - 50 mm IOAODTLD0009 64 each
10 10 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.4Cx2.5 sqmm (2XWY) IOAODTLD0010 450 RM
11 11 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.1Cx16 (A2XY) (Aluminum) IOAODTLD0011 240 RM
12 12 Welding of supplied WNRF 300# Sch 80: Job includes erection of pipes, fittings, flanges, nut , studs, gaskets etc. Transportation from OWNER/ VENDOR’S stores/storage points to shop/site, installation in position by threading, bolting or welding as per drawings, specifications, standards/ codes, instructions of Owner\n/Owner's representative and scope of work along with supplying and fixing of Metallic Spiral Wound gaskets (with 100% spare quantity for replacement after hydrotesting) confirm to SS 316 with Graphite fill as per ASME B16.20, nuts & stud bolts confirm to ASTM A194-2H & ASTM\nA193B-7 respectively. Rates shall also include the cost of supply of stud nuts, washers, gaskets, supervision, labor, overhead /profits, materials in Vendors scope, Hydrostatic testing of spool pieces before installation wherever required and other associated arrangements required to execute all the related activities. Rates shall be inclusive of cost of supervision, labour, overheads/profits, material which are in vendor's scope, consumables, conditions listed in preamble / scope of work and other associated arrangements required for the work to be completed as per the existing site conditions including the shut down jobs in a working / operating LPG Plant. Shifting, positioning, cutting pipe line as necessary, laying the pipelines above ground at all elevations, manifold connections to existing manifolds / pipelines as per the tentative layout and welding, handling laying with flanges, bends, elbows, tees, reducers etc. aligning the pipeline as per good engineering practices and instructions of IOCL. This item also includes supply and erection of studs, washers, nuts and gaskets, bonding jumpers of 30 mm wide 6 mm thk GI strips. Note: Required Electrical power and water shall be arranged at one place and it's successful bidder's responsibility to lay required cables / hoses / pipes etc., as required for the work. IOAODTLD0012 64 each
13 13 Erection of supplied ROVs with all electrical, pneumatic and flange connections complete. IOAODTLD0013 32 each
14 14 Radiography of all the joints IOAODTLD0014 64 Each
15 15 Supply, cutting, welding, fabrication and erection in place for structural steel stands, brackets etc., for installation of JBs, Cable Trays, etc., as per instructions of EIC complete with fasteners, anchor bolts etc., as\nrequired for erection of stands / brackets. IOAODTLD0015 1000 kgs
16 16 Testing and commissioning of entire earthing system complete for the TLD Gantry of 8 Bays, along with of cable trays inside and outside TLD Bays up to ROVs, fixing and laying of supplied cable trays complete as per instructions of site engineer.\nThe item also includes fixing FLP Glands, supply and providing PESO approved FLP dummies of required size of unused cable entries in FLP JBs, termination of cables / wires, earthing for the JBs as per instruction of EIC\nwith the nearest earth bus bar. IOAODTLD0016 1 LS
17 17 Part B: Supply and Erection: Sekmai IOAODTLD0017
18 18 Supply of Ex Proof Resistive Capacitive type earthing relay of approved make as per technical specifications mentioned in the tender document in PESO / CCOE approved FLP enclosure for usage in Zone 1 (Hazardous Area Classification as per IS 2148).\nFlameproof cum weather proof smart type Grounding unit (Resistive Capacitive type earthing relay) shall have Red and Green indicating lamps and dual output for safety earthing of tank trucks, suitable for giving safety\ninterlocking signal as per specifications and datasheet. IOAODTLD0018 8 each
19 19 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables.4Cx2.5 sqmm (2XWY) for Power / Signal IOAODTLD0019 225 RM
20 20 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables1Cx16 (A2XY) (Aluminum) for earthing IOAODTLD0020 120 RM
21 21 Supply of 4 way FLP JBs of approved make duly approved by PESO for usage in Hazardous Area - Zone I with PESO Approved FLP Glands of suitable size, complete as required for termination of cable inside the JBs. These JBs to be installed at each bay of TLD for incoming supply to earthing relays from header cable. IOAODTLD0021 8 each
22 22 Supply of GI Cable trays of size: 100 mm width IOAODTLD0022 30 RM
23 23 Supply of GI Cable trays of size:200 mm width IOAODTLD0023 30 RM
24 24 Supply of ROV(Ball Valve + Pneumatic Actuator + Solenoid Valve + Required accessories), 2" 300# RF, A216 WCB, SS316 Ball material, Wetted parts: SS316, Class VI, Fire safe, hand wheel, 1 SOV, 1 AFR as per specifications and data\nsheets given. IOAODTLD0024 16 Each
25 25 Supply of WNRF A 105 CS 300# Sch 80 - 50 mm IOAODTLD0025 32 each
26 26 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.4Cx2.5 sqmm (2XWY) IOAODTLD0026 225 RM
27 27 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.1Cx16 (A2XY) (Aluminum) IOAODTLD0027 120 RM
28 28 Welding of supplied WNRF 300# Sch 80: Job includes erection of pipes, fittings, flanges, nut , studs, gaskets etc. Transportation from OWNER/ VENDOR’S stores/storage points to shop/site, installation in position by threading, bolting or welding as per drawings, specifications, standards/ codes, instructions of Owner\n/Owner's representative and scope of work along with supplying and fixing of Metallic Spiral Wound gaskets (with 100% spare quantity for replacement after hydrotesting) confirm to SS 316 with Graphite fill as per ASME B16.20, nuts & stud bolts confirm to ASTM A194-2H & ASTM\nA193B-7 respectively. Rates shall also include the cost of supply of stud nuts, washers, gaskets, supervision, labor, overhead /profits, materials in Vendors scope, Hydrostatic testing of spool pieces before installation wherever required and other associated arrangements required to execute all the related activities. Rates shall be inclusive of cost of supervision, labour, overheads/profits, material which are in vendor's scope, consumables, conditions listed in preamble / scope of work and other associated arrangements required for the work to be completed as per the existing site conditions including the shut down jobs in a working / operating LPG Plant. Shifting, positioning, cutting pipe line as necessary, laying the pipelines above ground at all elevations, manifold connections to existing manifolds / pipelines as per the tentative layout and welding, handling laying with flanges, bends, elbows, tees, reducers etc. aligning the pipeline as per good engineering practices and instructions of IOCL. This item also includes supply and erection of studs, washers, nuts and gaskets, bonding jumpers of 30 mm wide 6 mm thk GI strips. Note: Required Electrical power and water shall be arranged at one place and it's successful bidder's responsibility to lay required cables / hoses / pipes etc., as required for the work. IOAODTLD0028 32 each
29 29 Erection of supplied ROVs with all electrical, pneumatic and flange connections complete. IOAODTLD0029 16 each
30 30 Radiography of all the joints IOAODTLD0030 32 Each
31 31 Supply, cutting, welding, fabrication and erection in place for structural steel stands, brackets etc., for installation of JBs, Cable Trays, etc., as per instructions of EIC complete with fasteners, anchor bolts etc., as\nrequired for erection of stands / brackets. IOAODTLD0031 500 kgs
32 32 Testing and commissioning of entire earthing system complete for the TLD Gantry of 8 Bays, along with of cable trays inside and outside TLD Bays up to ROVs, fixing and laying of supplied cable trays complete as per instructions of site engineer.\nThe item also includes fixing FLP Glands, supply and providing PESO approved FLP dummies of required size of unused cable entries in FLP JBs, termination of cables / wires, earthing for the JBs as per instruction of EIC\nwith the nearest earth bus bar. IOAODTLD0032 1 LS
33 33 Part C: Supply and Erection: Silchar IOAODTLD0033
34 34 Supply of Ex Proof Resistive Capacitive type earthing relay of approved make as per technical specifications mentioned in the tender document in PESO / CCOE approved FLP enclosure for usage in Zone 1 (Hazardous Area Classification as per IS 2148).\nFlameproof cum weather proof smart type Grounding unit (Resistive Capacitive type earthing relay) shall have Red and Green indicating lamps and dual output for safety earthing of tank trucks, suitable for giving safety\ninterlocking signal as per specifications and datasheet. IOAODTLD0034 8 each
35 35 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables.4Cx2.5 sqmm (2XWY) for Power / Signal IOAODTLD0035 225 RM
36 36 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables1Cx16 (A2XY) (Aluminum) for earthing IOAODTLD0036 120 RM
37 37 Supply of 4 way FLP JBs of approved make duly approved by PESO for usage in Hazardous Area - Zone I with PESO Approved FLP Glands of suitable size, complete as required for termination of cable inside the JBs. These JBs to be installed at each bay of TLD for incoming supply to earthing relays from header cable. IOAODTLD0037 8 each
38 38 Supply of GI Cable trays of size: 100 mm width IOAODTLD0038 30 RM
39 39 Supply of GI Cable trays of size:200 mm width IOAODTLD0039 30 RM
40 40 Supply of ROV(Ball Valve + Pneumatic Actuator + Solenoid Valve + Required accessories), 2" 300# RF, A216 WCB, SS316 Ball material, Wetted parts: SS316, Class VI, Fire safe, hand wheel, 1 SOV, 1 AFR as per specifications and data\nsheets given. IOAODTLD0040 16 Each
41 41 Supply of WNRF A 105 CS 300# Sch 80 - 50 mm IOAODTLD0041 32 each
42 42 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.4Cx2.5 sqmm (2XWY) IOAODTLD0042 225 RM
43 43 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.1Cx16 (A2XY) (Aluminum) IOAODTLD0043 120 RM
44 44 Welding of supplied WNRF 300# Sch 80: Job includes erection of pipes, fittings, flanges, nut , studs, gaskets etc. Transportation from OWNER/ VENDOR’S stores/storage points to shop/site, installation in position by threading, bolting or welding as per drawings, specifications, standards/ codes, instructions of Owner\n/Owner's representative and scope of work along with supplying and fixing of Metallic Spiral Wound gaskets (with 100% spare quantity for replacement after hydrotesting) confirm to SS 316 with Graphite fill as per ASME B16.20, nuts & stud bolts confirm to ASTM A194-2H & ASTM\nA193B-7 respectively. Rates shall also include the cost of supply of stud nuts, washers, gaskets, supervision, labor, overhead /profits, materials in Vendors scope, Hydrostatic testing of spool pieces before installation wherever required and other associated arrangements required to execute all the related activities. Rates shall be inclusive of cost of supervision, labour, overheads/profits, material which are in vendor's scope, consumables, conditions listed in preamble / scope of work and other associated arrangements required for the work to be completed as per the existing site conditions including the shut down jobs in a working / operating LPG Plant. Shifting, positioning, cutting pipe line as necessary, laying the pipelines above ground at all elevations, manifold connections to existing manifolds / pipelines as per the tentative layout and welding, handling laying with flanges, bends, elbows, tees, reducers etc. aligning the pipeline as per good engineering practices and instructions of IOCL. This item also includes supply and erection of studs, washers, nuts and gaskets, bonding jumpers of 30 mm wide 6 mm thk GI strips. Note: Required Electrical power and water shall be arranged at one place and it's successful bidder's responsibility to lay required cables / hoses / pipes etc., as required for the work. IOAODTLD0044 32 each
45 45 Erection of supplied ROVs with all electrical, pneumatic and flange connections complete. IOAODTLD0045 16 each
46 46 Radiography of all the joints IOAODTLD0046 32 Each
47 47 Supply, cutting, welding, fabrication and erection in place for structural steel stands, brackets etc., for installation of JBs, Cable Trays, etc., as per instructions of EIC complete with fasteners, anchor bolts etc., as\nrequired for erection of stands / brackets. IOAODTLD0047 500 kgs
48 48 Testing and commissioning of entire earthing system complete for the TLD Gantry of 8 Bays, along with of cable trays inside and outside TLD Bays up to ROVs, fixing and laying of supplied cable trays complete as per instructions of site engineer.\nThe item also includes fixing FLP Glands, supply and providing PESO approved FLP dummies of required size of unused cable entries in FLP JBs, termination of cables / wires, earthing for the JBs as per instruction of EIC\nwith the nearest earth bus bar. IOAODTLD0048 1 LS
49 49 Part D: Supply and Erection: Sarpara IOAODTLD0049
50 50 Supply of Ex Proof Resistive Capacitive type earthing relay of approved make as per technical specifications mentioned in the tender document in PESO / CCOE approved FLP enclosure for usage in Zone 1 (Hazardous Area Classification as per IS 2148).\nFlameproof cum weather proof smart type Grounding unit (Resistive Capacitive type earthing relay) shall have Red and Green indicating lamps and dual output for safety earthing of tank trucks, suitable for giving safety\ninterlocking signal as per specifications and datasheet. IOAODTLD0050 5 each
51 51 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables.4Cx2.5 sqmm (2XWY) for Power / Signal IOAODTLD0051 140.625 RM
52 52 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables1Cx16 (A2XY) (Aluminum) for earthing IOAODTLD0052 75 RM
53 53 Supply of 4 way FLP JBs of approved make duly approved by PESO for usage in Hazardous Area - Zone I with PESO Approved FLP Glands of suitable size, complete as required for termination of cable inside the JBs. These JBs to be installed at each bay of TLD for incoming supply to earthing relays from header cable. IOAODTLD0053 5 each
54 54 Supply of GI Cable trays of size: 100 mm width IOAODTLD0054 18.75 RM
55 55 Supply of GI Cable trays of size:200 mm width IOAODTLD0055 18.75 RM
56 56 Supply of ROV(Ball Valve + Pneumatic Actuator + Solenoid Valve + Required accessories), 2" 300# RF, A216 WCB, SS316 Ball material, Wetted parts: SS316, Class VI, Fire safe, hand wheel, 1 SOV, 1 AFR as per specifications and data\nsheets given. IOAODTLD0056 10 Each
57 57 Supply of WNRF A 105 CS 300# Sch 80 - 50 mm IOAODTLD0057 20 each
58 58 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.4Cx2.5 sqmm (2XWY) IOAODTLD0058 140.625 RM
59 59 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.1Cx16 (A2XY) (Aluminum) IOAODTLD0059 75 RM
60 60 Welding of supplied WNRF 300# Sch 80: Job includes erection of pipes, fittings, flanges, nut , studs, gaskets etc. Transportation from OWNER/ VENDOR’S stores/storage points to shop/site, installation in position by threading, bolting or welding as per drawings, specifications, standards/ codes, instructions of Owner\n/Owner's representative and scope of work along with supplying and fixing of Metallic Spiral Wound gaskets (with 100% spare quantity for replacement after hydrotesting) confirm to SS 316 with Graphite fill as per ASME B16.20, nuts & stud bolts confirm to ASTM A194-2H & ASTM\nA193B-7 respectively. Rates shall also include the cost of supply of stud nuts, washers, gaskets, supervision, labor, overhead /profits, materials in Vendors scope, Hydrostatic testing of spool pieces before installation wherever required and other associated arrangements required to execute all the related activities. Rates shall be inclusive of cost of supervision, labour, overheads/profits, material which are in vendor's scope, consumables, conditions listed in preamble / scope of work and other associated arrangements required for the work to be completed as per the existing site conditions including the shut down jobs in a working / operating LPG Plant. Shifting, positioning, cutting pipe line as necessary, laying the pipelines above ground at all elevations, manifold connections to existing manifolds / pipelines as per the tentative layout and welding, handling laying with flanges, bends, elbows, tees, reducers etc. aligning the pipeline as per good engineering practices and instructions of IOCL. This item also includes supply and erection of studs, washers, nuts and gaskets, bonding jumpers of 30 mm wide 6 mm thk GI strips. Note: Required Electrical power and water shall be arranged at one place and it's successful bidder's responsibility to lay required cables / hoses / pipes etc., as required for the work. IOAODTLD0060 20 each
61 61 Erection of supplied ROVs with all electrical, pneumatic and flange connections complete. IOAODTLD0061 10 each
62 62 Radiography of all the joints IOAODTLD0062 20 Each
63 63 Supply, cutting, welding, fabrication and erection in place for structural steel stands, brackets etc., for installation of JBs, Cable Trays, etc., as per instructions of EIC complete with fasteners, anchor bolts etc., as\nrequired for erection of stands / brackets. IOAODTLD0063 312.5 kgs
64 64 Testing and commissioning of entire earthing system complete for the TLD Gantry of 8 Bays, along with of cable trays inside and outside TLD Bays up to ROVs, fixing and laying of supplied cable trays complete as per instructions of site engineer.\nThe item also includes fixing FLP Glands, supply and providing PESO approved FLP dummies of required size of unused cable entries in FLP JBs, termination of cables / wires, earthing for the JBs as per instruction of EIC\nwith the nearest earth bus bar. IOAODTLD0064 1 LS
65 65 Part E: Supply and Erection: Gopanari IOAODTLD0065
66 66 Supply of Ex Proof Resistive Capacitive type earthing relay of approved make as per technical specifications mentioned in the tender document in PESO / CCOE approved FLP enclosure for usage in Zone 1 (Hazardous Area Classification as per IS 2148).\nFlameproof cum weather proof smart type Grounding unit (Resistive Capacitive type earthing relay) shall have Red and Green indicating lamps and dual output for safety earthing of tank trucks, suitable for giving safety\ninterlocking signal as per specifications and datasheet. IOAODTLD0066 8 Nos
67 67 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables.4Cx2.5 sqmm (2XWY) for Power / Signal IOAODTLD0067 225 Nos
68 68 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables1Cx16 (A2XY) (Aluminum) for earthing IOAODTLD0068 120 Nos
69 69 Supply of 4 way FLP JBs of approved make duly approved by PESO for usage in Hazardous Area - Zone I with PESO Approved FLP Glands of suitable size, complete as required for termination of cable inside the JBs. These JBs to be installed at each bay of TLD for incoming supply to earthing relays from header cable. IOAODTLD0069 8 Nos
70 70 Supply of GI Cable trays of size: 100 mm width IOAODTLD0070 30 Nos
71 71 Supply of GI Cable trays of size:200 mm width IOAODTLD0071 30 Nos
72 72 Supply of ROV(Ball Valve + Pneumatic Actuator + Solenoid Valve + Required accessories), 2" 300# RF, A216 WCB, SS316 Ball material, Wetted parts: SS316, Class VI, Fire safe, hand wheel, 1 SOV, 1 AFR as per specifications and data\nsheets given. IOAODTLD0072 16 Nos
73 73 Supply of WNRF A 105 CS 300# Sch 80 - 50 mm IOAODTLD0073 32 Nos
74 74 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.4Cx2.5 sqmm (2XWY) IOAODTLD0074 225 Nos
75 75 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.1Cx16 (A2XY) (Aluminum) IOAODTLD0075 120 Nos
76 76 Welding of supplied WNRF 300# Sch 80: Job includes erection of pipes, fittings, flanges, nut , studs, gaskets etc. Transportation from OWNER/ VENDOR’S stores/storage points to shop/site, installation in position by threading, bolting or welding as per drawings, specifications, standards/ codes, instructions of Owner\n/Owner's representative and scope of work along with supplying and fixing of Metallic Spiral Wound gaskets (with 100% spare quantity for replacement after hydrotesting) confirm to SS 316 with Graphite fill as per ASME B16.20, nuts & stud bolts confirm to ASTM A194-2H & ASTM\nA193B-7 respectively. Rates shall also include the cost of supply of stud nuts, washers, gaskets, supervision, labor, overhead /profits, materials in Vendors scope, Hydrostatic testing of spool pieces before installation wherever required and other associated arrangements required to execute all the related activities. Rates shall be inclusive of cost of supervision, labour, overheads/profits, material which are in vendor's scope, consumables, conditions listed in preamble / scope of work and other associated arrangements required for the work to be completed as per the existing site conditions including the shut down jobs in a working / operating LPG Plant. Shifting, positioning, cutting pipe line as necessary, laying the pipelines above ground at all elevations, manifold connections to existing manifolds / pipelines as per the tentative layout and welding, handling laying with flanges, bends, elbows, tees, reducers etc. aligning the pipeline as per good engineering practices and instructions of IOCL. This item also includes supply and erection of studs, washers, nuts and gaskets, bonding jumpers of 30 mm wide 6 mm thk GI strips. Note: Required Electrical power and water shall be arranged at one place and it's successful bidder's responsibility to lay required cables / hoses / pipes etc., as required for the work. IOAODTLD0076 32 Nos
77 77 Erection of supplied ROVs with all electrical, pneumatic and flange connections complete. IOAODTLD0077 16 Nos
78 78 Radiography of all the joints IOAODTLD0078 32 Nos
79 79 Supply, cutting, welding, fabrication and erection in place for structural steel stands, brackets etc., for installation of JBs, Cable Trays, etc., as per instructions of EIC complete with fasteners, anchor bolts etc., as\nrequired for erection of stands / brackets. IOAODTLD0079 500 Nos
80 80 Testing and commissioning of entire earthing system complete for the TLD Gantry of 8 Bays, along with of cable trays inside and outside TLD Bays up to ROVs, fixing and laying of supplied cable trays complete as per instructions of site engineer.\nThe item also includes fixing FLP Glands, supply and providing PESO approved FLP dummies of required size of unused cable entries in FLP JBs, termination of cables / wires, earthing for the JBs as per instruction of EIC\nwith the nearest earth bus bar. IOAODTLD0080 1 Nos
81 81 Part F: Supply and Erection: Dimapur IOAODTLD0081
82 82 Supply of Ex Proof Resistive Capacitive type earthing relay of approved make as per technical specifications mentioned in the tender document in PESO / CCOE approved FLP enclosure for usage in Zone 1 (Hazardous Area Classification as per IS 2148).\nFlameproof cum weather proof smart type Grounding unit (Resistive Capacitive type earthing relay) shall have Red and Green indicating lamps and dual output for safety earthing of tank trucks, suitable for giving safety\ninterlocking signal as per specifications and datasheet. IOAODTLD0082 3 Nos
83 83 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables.4Cx2.5 sqmm (2XWY) for Power / Signal IOAODTLD0083 84.375 Nos
84 84 Supply of 1.1 KV LT XLPE PVC Sheathed HR copper / aluminum Power Armoured cables of following sizes as\nper IS:7098 Part-I. Conductor shall be multi stranded for all sizes of cables1Cx16 (A2XY) (Aluminum) for earthing IOAODTLD0084 45 Nos
85 85 Supply of 4 way FLP JBs of approved make duly approved by PESO for usage in Hazardous Area - Zone I with PESO Approved FLP Glands of suitable size, complete as required for termination of cable inside the JBs. These JBs to be installed at each bay of TLD for incoming supply to earthing relays from header cable. IOAODTLD0085 3 Nos
86 86 Supply of GI Cable trays of size: 100 mm width IOAODTLD0086 11.25 Nos
87 87 Supply of GI Cable trays of size:200 mm width IOAODTLD0087 11.25 Nos
88 88 Supply of ROV(Ball Valve + Pneumatic Actuator + Solenoid Valve + Required accessories), 2" 300# RF, A216 WCB, SS316 Ball material, Wetted parts: SS316, Class VI, Fire safe, hand wheel, 1 SOV, 1 AFR as per specifications and data\nsheets given. IOAODTLD0088 6 Nos
89 89 Supply of WNRF A 105 CS 300# Sch 80 - 50 mm IOAODTLD0089 12 Nos
90 90 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.4Cx2.5 sqmm (2XWY) IOAODTLD0090 84.375 Nos
91 91 Erection : Horizontal and vertical laying of XLPE / PVC insulated armoured and PVC sheathed cables 1.1 KV grade of the following sizes in readymade concrete or soil trenches, trays, risers, support hangers, saddles etc., pulling through pipe on walls, floors and columns, steel structures including transportation from\nstores to site, unpacking, erection, dressing including supply and fixing of aluminum tags for identification of cable at both ends and at every 30 meter interval, providing GI saddles, saddle bars GI / Al clamps for cables laid\nvertically on walls / column / structures etc., GI bolts, nuts and washers, lugs of appropriate size etc., complete with all labour, material and as per specification enclosed and direction of site in-charge, excluding supply of cables. Item also includes laying and fixing of supplied cable trays wherever required complete as per instructions of LIC.1Cx16 (A2XY) (Aluminum) IOAODTLD0091 45 Nos
92 92 Welding of supplied WNRF 300# Sch 80: Job includes erection of pipes, fittings, flanges, nut , studs, gaskets etc. Transportation from OWNER/ VENDOR’S stores/storage points to shop/site, installation in position by threading, bolting or welding as per drawings, specifications, standards/ codes, instructions of Owner\n/Owner's representative and scope of work along with supplying and fixing of Metallic Spiral Wound gaskets (with 100% spare quantity for replacement after hydrotesting) confirm to SS 316 with Graphite fill as per ASME B16.20, nuts & stud bolts confirm to ASTM A194-2H & ASTM\nA193B-7 respectively. Rates shall also include the cost of supply of stud nuts, washers, gaskets, supervision, labor, overhead /profits, materials in Vendors scope, Hydrostatic testing of spool pieces before installation wherever required and other associated arrangements required to execute all the related activities. Rates shall be inclusive of cost of supervision, labour, overheads/profits, material which are in vendor's scope, consumables, conditions listed in preamble / scope of work and other associated arrangements required for the work to be completed as per the existing site conditions including the shut down jobs in a working / operating LPG Plant. Shifting, positioning, cutting pipe line as necessary, laying the pipelines above ground at all elevations, manifold connections to existing manifolds / pipelines as per the tentative layout and welding, handling laying with flanges, bends, elbows, tees, reducers etc. aligning the pipeline as per good engineering practices and instructions of IOCL. This item also includes supply and erection of studs, washers, nuts and gaskets, bonding jumpers of 30 mm wide 6 mm thk GI strips. Note: Required Electrical power and water shall be arranged at one place and it's successful bidder's responsibility to lay required cables / hoses / pipes etc., as required for the work. IOAODTLD0092 12 Nos
93 93 Erection of supplied ROVs with all electrical, pneumatic and flange connections complete. IOAODTLD0093 6 Nos
94 94 Radiography of all the joints IOAODTLD0094 12 Nos
95 95 Supply, cutting, welding, fabrication and erection in place for structural steel stands, brackets etc., for installation of JBs, Cable Trays, etc., as per instructions of EIC complete with fasteners, anchor bolts etc., as\nrequired for erection of stands / brackets. IOAODTLD0095 187.5 Nos
96 96 Testing and commissioning of entire earthing system complete for the TLD Gantry of 8 Bays, along with of cable trays inside and outside TLD Bays up to ROVs, fixing and laying of supplied cable trays complete as per instructions of site engineer.\nThe item also includes fixing FLP Glands, supply and providing PESO approved FLP dummies of required size of unused cable entries in FLP JBs, termination of cables / wires, earthing for the JBs as per instruction of EIC\nwith the nearest earth bus bar. IOAODTLD0096 1 Nos
97 97 Applicable GST @18% IOAODTLD0097 1 LS
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail