}

Operation Comprehensive Maintenance Of Ems For T E Bldg At Rayya Jandiala Guru Majitha Ajnala Comprehensive Maintenance Of Ems For Various Rented Buildings Group Exchanges Under Sdca Goindwal Rayya Jandiala Guru Majitha Aajnala . Shclearingofdefect Ope, Amritsar-Punjab

Bharat Sanchar Nigam Limited has published Operation Comprehensive Maintenance Of Ems For T E Bldg At Rayya Jandiala Guru Majitha Ajnala Comprehensive Maintenance Of Ems For Various Rented Buildings Group Exchanges Under Sdca Goindwal Rayya Jandiala Guru Majitha Aajnala . Shclearingofdefect Ope. Submission Date for this Tender is 05-04-2021. Tanks and Cylinders Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

27222052
Corrigendum : Operation Comprehensive Maintenance Of Ems For T E Bldg At Rayya Jandiala Guru Majitha Ajnala Comprehensive Maintenance Of Ems For Various Rented Buildings Group Exchanges Under Sdca Goindwal Rayya Jandiala Guru Majitha Aajnala . Shclearingofdefect Ope
Open Tender
NCB
Punjab
Amritsar
05-04-2021

Tender Details

Operation Comprehensive Maintenance Of Ems For T E Bldg At Rayya Jandiala Guru Majitha Ajnala Comprehensive Maintenance Of Ems For Various Rented Buildings Group Exchanges Under Sdca Goindwal Rayya Jandiala Guru Majitha Aajnala . Shclearingofdefect Operation Comprehensive Maintenance Of Ems For T E Bldg At Rayya Jandiala Guru Majitha Ajnala Comprehensive Maintenance Of Ems For Various Rented Buildings Group Exchanges Under Sdca Goindwal Rayya Jandiala Guru Majitha A Ajnalashclearingofdefect , Wet Servicing Of Existing 1 . 5Tr/2Tr Window/Split Ac Unit I/C Removing , Cleaning All Components And Filters , Dedusting By High Pressure Air Blower , Washing Condenser , Evaporator I/C Chemical Cleaning ( If Required ) , Refixing , Tightening Electrical Connections , Testing Of Ac Unit , Recording All Parameters In Service Report Etc As Reqd . , Providing And Charging Of R-22 Refrigerant Gas Including Carrying Out Leak Testing Of 1 . 5Tr Split/Wac Ac Units With Nitrogen Gas Including Dismantling Of Machine , Flushing The System , Brazing/Flaring The Leak Points , Vacumising , Purging And Making The System Leak Proof I/C Transportation Of Nitrogen Cylinder , Brazing Kit & Vacuum Pump , Supplying & Charging Of R22 Refrigerant Gas At Site , Reinstallation , Testing & Commissioning Complete Etc As Required . , 1 . 5/2 . 0 Tr , Replacement Of Following Capacity Of Existing Old Defective Compressor With New Sealed Compressor I/C Dismantling Of Faulty Compressor , Cutting Refrigerant Piping , Brazing & Making Necessary Addition/Alteration I/C Proper Mounting On Base Plate , Connection Of Suction And Discharge Lines , Leak Test & Charging Refrigerant I/C Testing Etc As Reqd . ( M/S Emerson/Tecumseh/Ss Make ) ( Note- The Firm Shall Submit Test Certificate Or Documentary Proof Towards Purchase Of New/Oem Factory Repaired Compressor . ) The Defective Compressor Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting . The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) , 1 . 5 Tr , Replacement Of Following Material For Repairing & Attending Break Down Complaints Of 1 . 5 Tr Wac/Sac Units I/C Dismantling , Connection , Fixing & Testing Etc As Required . ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting . The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory . , Starting Capacitor ( Metal Body ) Of Rating Suitable For 1 . 5/2 . 0 Tr ( 80/100 Mfd ) ( M/S Epcos/Asian/Ss Make ) , Running Capacitor ( Metal Body ) Of Rating Suitable For 1 . 5/2 . 0 Tr ( M/S Epcos/Asian/Ss Make ) , Repairing Of Control Card Pcb Existing 1 . 5/2 . 0Tr Split Ac Units , Condenser Fan Blade ( Pvc/Frp ) , Condensor Coil , Replacement Of Control Card Pcb Suitable For 1 . 5Tr Split Ac Units , Blower Fan Motor For Idu Of Split Ac Unit ( M/S Aue/Marathon Ge/National/ Diamond /Ss Make ) , Thermostat ( M/S Danfoss/Indfoss/Arvind/Ss Make , Washable Nylon Air Filter , Replacement/Rewinding Of Existing Condenser Motor Of 1 . 5/2 Tr Split/Window Ac Unit From Workshop Complete With Reinstallation , Testing Etc As Required , 3 Core Flexible Copper Cable 2 . 5 Sq Mm , Sitc Of Photo Electric Type Smoke Detector Complete With Detector Base Etc As Reqd And As Per Bsnl Specifications , Sitc Of Electro Pneumatic Type Dual Action ( Heat-Cum-Rate Of Rise In Temperature ) Heat Detector Complete With Detector Base Etc As Reqd And As Per Bsnl Specifications . , Providing Repairs To The Existing Microprocessor Based Fire Detection And Fire Alarm Panel I/C Replacement Of Transformer , Control Cards , Pcb I/C Making Minor Repairs To Make The Panel Fully Functional As Per The Directions Of The Engineer In Charge . , Replacement Of Following Ampere Hour Capacity Sealed Maintenance Free Battery I/C Making Connections , Testing And Commissioning Etc Comp . As Reqd Complete With Dismantling Of Old Defective Batteries . ( Note:The Old Dismantled Battery Shall Be The Property Of The Agency . ) , 12V-7Ah , 12V- 26Ah , Refilling Of Existing 4 . 5 Kg Co2 In The Existing 4 . 5 Kg Co2 Type Cylinder Including Transportation To The Filling Facility And Back To Concerned Te Bldg . Including Testing And Commissioning Complete Etc As Required . , Supplying And Fixing Following Items In The Existing 4 . 5 Kg Co2 Fire Extinguishers I/C Testing And Commissioning Etc As Reqd . , Horns With Hose Pipe , Topping Up Of Transformer Oil With Dielectric Strength More Than 40 Kv In The Existing Transformer/ Ocb Etc . Comp . As Reqd . , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders/ Change Over Switch In Existing Cubicle Panel Board Including Drilling Holes In The Cubicle Panel Making Connections Etc Comp . As Reqd . , 200/250 A , 65 Ka , Fpmccb , 250 Amp . Fp Change Over Switch , Providing And Fixing Following Components In The Existing Capacitor Panel Suitable I/C Making Connections , Testing And Commissioning Etc Comp . As Reqd . , 5Kvar Heavy Duty Cylindrical Capacitor Suitable For Linear Load , 10Kvar Heavy Duty Cylindrical Capacitor Suitable For Linear Load , Plugging The Leakage Of The Existing 200 Kva Transformer By Providing Suitable Size Of Gasket Etc . Complete As Per Requirement At Site .

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 17-03-2021 DateCorrigendumNIT29 Date 05-04-2021

Key Value

Document Fees
INR 590 /-
EMD
INR 17813.0 /-
Tender Value
INR 8.90 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail