Kshb E Office Electrical Work Of Executive Engineer Office Kottayam Kerala State Housing Board -Kottayam Division Consultancy Work E Office Electrical Work Of Executive Engineer Office Kottayam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Mar 2021
0 days left
EMD
7800
Bank guarantee accepted
Document Fee
620
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanjikuzhy → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Kshb E Office Electrical Work Of Executive Engineer Office Kottayam Kerala State Housing Board -Kottayam Division Consultancy Work E Office Electrical Work Of Executive Engineer Office Kottayam
BOQ
| Work Name : KSHB- KHU-Kochi- e office Electrical work of Executive Engineer office Kottayam | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | e office Electrical Works Kottayam Division | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.01 | od268073/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories)..<br>Single Control light point with 6A, plate ceiling rose - Short point | BI01010001010000000000000515BI0100001114 | 10 | point |
| 3 | 1.02 | 90.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required | BI01010001010000000000000515BI0100001115 | 15 | each |
| 4 | 1.03 | od280141/2020_2021 : Supply, conveyance, installation, testing and commissioning of the following sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.450 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C | BI01010001010000000000000515BI0100001116 | 1 | each |
| 5 | 1.04 | od280142/2020_2021 : Supply,providing,testing and commissioning of 7W to 9 W PWD Approved make LED Bulb<br> | BI01010001010000000000000515BI0100001117 | 2 | each |
| 6 | 1.05 | 90.3.19.4 : 1200 mm 2X20W LED Lamp with box type fixture | BI01010001010000000000000515BI0100001118 | 2 | each |
| 7 | 1.06 | od268074/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories)..<br>Single control light point without ceiling rose - Short point | BI01010001010000000000000515BI0100001119 | 3 | point |
| 8 | 1.07 | od268075/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories).<br>Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | BI01010001010000000000000515BI0100001120 | 6 | point |
| 9 | 1.08 | 90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. | BI01010001010000000000000515BI0100001121 | 8 | each |
| 10 | 1.09 | 1.47 : Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | BI01010001010000000000000515BI0100001122 | 3 | each |
| 11 | 1.1 | 1.48 : Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) | BI01010001010000000000000515BI0100001123 | 10 | each |
| 12 | 1.11 | od268076/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.<br>Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.<br>Group A | BI01010001010000000000000515BI0100001124 | 3 | point |
| 13 | 1.12 | od268077/2020_2021 : Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.5 sq mm FRLS PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FRLS PVC insulated wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required (RoHS compliant modular accessories).<br>Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point | BI01010001010000000000000515BI0100001125 | 1 | point |
| 14 | 1.13 | 1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. | BI01010001010000000000000515BI0100001126 | 1 | each |
| 15 | 1.14 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | BI01010001010000000000000515BI0100001127 | 100 | metre |
| 16 | 1.15 | 1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm | BI01010001010000000000000515BI0100001128 | 5 | metre |
| 17 | 1.16 | 90.12.7.3 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. | BI01010001010000000000000515BI0100001129 | 4 | metre |
| 18 | 1.17 | 1.17.30 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | BI01010001010000000000000515BI0100001130 | 50 | metre |
| 19 | 1.18 | 90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. | BI01010001010000000000000515BI0100001131 | 3 | metre |
| 20 | 1.19 | 90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. | BI01010001010000000000000515BI0100001132 | 3 | metre |
| 21 | 1.2 | 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm | BI01010001010000000000000515BI0100001133 | 200 | metre |
| 22 | 1.21 | 1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm | BI01010001010000000000000515BI0100001134 | 100 | metre |
| 23 | 1.22 | 2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door | BI01010001010000000000000515BI0100001135 | 1 | each |
| 24 | 1.23 | 2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door | BI01010001010000000000000515BI0100001136 | 1 | each |
| 25 | 1.24 | 90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required | BI01010001010000000000000515BI0100001137 | 1 | each |
| 26 | 1.25 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole | BI01010001010000000000000515BI0100001138 | 32 | each |
| 27 | 1.26 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001139 | 2 | each |
| 28 | 1.27 | 2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole | BI01010001010000000000000515BI0100001140 | 3 | each |
| 29 | 1.28 | 2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | BI01010001010000000000000515BI0100001141 | 10 | each |
| 30 | 1.29 | 2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual \n current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | BI01010001010000000000000515BI0100001142 | 2 | each |
| 31 | 1.3 | 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | BI01010001010000000000000515BI0100001143 | 1 | each |
| 32 | 1.31 | 90.9.2.2 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. | BI01010001010000000000000515BI0100001144 | 8 | metre |
| 33 | 1.32 | 90.9.2.3 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. | BI01010001010000000000000515BI0100001145 | 8 | each |
| 34 | 1.33 | 90.9.2.5 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. | BI01010001010000000000000515BI0100001146 | 8 | each |
| 35 | 1.34 | 90.9.2.6 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. | BI01010001010000000000000515BI0100001147 | 4 | each |
| 36 | 1.35 | 90.9.2.8 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. | BI01010001010000000000000515BI0100001148 | 3 | each |
| 37 | 1.36 | 90.9.2.10 : Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. | BI01010001010000000000000515BI0100001149 | 8 | each |
| 38 | 1.37 | 1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm) | BI01010001010000000000000515BI0100001150 | 1 | each |
| 39 | 1.38 | 1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) | BI01010001010000000000000515BI0100001151 | 10 | each |
| 40 | 1.39 | 1.27.6 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm) | BI01010001010000000000000515BI0100001152 | 4 | each |
| 41 | 1.4 | 1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module | BI01010001010000000000000515BI0100001153 | 3 | each |
| 42 | 1.41 | 1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module | BI01010001010000000000000515BI0100001154 | 16 | each |
| 43 | 1.42 | 1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module | BI01010001010000000000000515BI0100001155 | 2 | each |
| 44 | 1.43 | 1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module | BI01010001010000000000000515BI0100001156 | 3 | each |
| 45 | 1.44 | 1.28.6 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module | BI01010001010000000000000515BI0100001157 | 2 | each |
| 46 | 1.45 | 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | BI01010001010000000000000515BI0100001158 | 25 | metre |
| 47 | 1.46 | 1.17.1 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm | BI01010001010000000000000515BI0100001159 | 50 | metre |
| 48 | 1.47 | 1.17.2 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm | BI01010001010000000000000515BI0100001160 | 50 | metre |
| 49 | 1.48 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | BI01010001010000000000000515BI0100001161 | 6 | each |
| 50 | 1.49 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | BI01010001010000000000000515BI0100001162 | 6 | each |
| 51 | 1.5 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001163 | 3 | each |
| 52 | 1.51 | 90.10.3.17 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant ) | BI01010001010000000000000515BI0100001164 | 90 | each |
| 53 | 1.52 | 1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch | BI01010001010000000000000515BI0100001165 | 100 | each |
| 54 | 1.53 | 1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet | BI01010001010000000000000515BI0100001166 | 1 | each |
| 55 | 1.54 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required | BI01010001010000000000000515BI0100001167 | 60 | metre |
| 56 | 1.55 | od268078/2020_2021 : Supply and fixing 4kg ABC fire extinguisher | BI01010001010000000000000515BI0100001168 | 3 | each |
| 57 | 1.56 | od268079/2020_2021 : Provision for CD/ PAPER WORKS AND GETTING NEW ELECTRICAL CONNECTION FOR RE OFFICE AMOUNT WILL BE REIMBURSED AFTER SUBMITTING ORIGINAL DOCUMENT | BI01010001010000000000000515BI0100001169 | 1 | L.S |
| 58 | 1.57 | od268080/2020_2021 : Charges for dismantling existing switch boards of all sizes with switches, sockets,etc without damages and the same stocked at electrical;l store room near the site.& Collected hand Receipt | BI01010001010000000000000515BI0100001170 | 30 | each set |
| 59 | 1.58 | od268081/2020_2021 : Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required 2.50 cm, 4 cm or 5 cm height | BI01010001010000000000000515BI0100001171 | 100 | each |
| 60 | 1.59 | od268082/2020_2021 : Supply, conveyance, installation, testing and commissioning of the following sizes of Wall fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.450 mm, single phase, heavy duty, 1400 rpm Wall fan in metal /Plastic frame High quality | BI01010001010000000000000515BI0100001172 | 2 | each |
| 61 | 1.6 | 1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | BI01010001010000000000000515BI0100001173 | 10 | each |
| 62 | 1.61 | 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. | BI01010001010000000000000515BI0100001174 | 30 | each |
| 63 | 1.62 | 1.34 : Supplying and fixing brass batten/ angle holder including connection etc. as required. | BI01010001010000000000000515BI0100001175 | 4 | each |
| 64 | 1.63 | 1.40 : Providing and fixing plain 16/0.20 mm (0.50 sqmm) twin circular flexible FRLS PVC insulated, PVC sheathes copper cable direct on the wall with PVC clips etc as required. | BI01010001010000000000000515BI0100001176 | 100 | metre |
| 65 | 1.64 | 1.59 : Dismantling of ceiling fan and painting the same with with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent and replacing the damaged rubber reel, nuts and bolts with washers and safety pins reinstalling the same as required. | BI01010001010000000000000515BI0100001177 | 10 | each |
| 66 | 1.65 | Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using\nstandard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC\ninsulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended\noriginal wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,\ncanopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C | 8 | each | |
| 67 | 1.66 | 1.15.1\nRewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated\ncopper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core\ncable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as\nrequired.Group A | 25 | point | |
| 68 | 1.67 | Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with thefollowing accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the\nwall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with\nbase and lid\n | 55 | metre |
AI Tender Summary
Tender Timeline
Mar 03, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedMar 10, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 15, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender