Supply Of Instruments/Equipments, OUAT Bhubaneswar-Odisha

Orissa University Of Agriculture And Technology-OUAT has published Supply Of Instruments/Equipments. Submission Date for this Tender is 15-03-2021. Rough Finishing Tools Tenders in OUAT Bhubaneswar Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

27210780
Supply Of Instruments/Equipments
Open Tender
Indian
Odisha
OUAT Bhubaneswar
15-03-2021

Tender Details

Supply Of Instruments / Equipments- Flow Meter 2 Size : 40- 100 Mm 3 Flow Range : 25- 250Ml / Mnt 4 Volume Per Revolution : 0.309L 5 Greatest Pressure : 2.5 Mpa 6 Accuracy : ±0.2% 7 Repeatability : =0.05% 8 Standard Unit : Rise 9 Co2 Probe 10 Application - Water / Chemical : Both 11 Nature Of The Chemical ( High Alkali / Hydrofloric Acid / Organic / Inorganic ) : Alkali With Organic And Inorganic 12 Moc Of The Sensor Required : Yes 13 Where To Be Mount Pipe / Vessel : Vessel 14 Top Mounting / Side Mounting : Top 15 Mounting Facility-Flange / Npt Etc., Specified : Npt 16 Operating Temperature : 0-121 17 Operating Pressure : 0-20 18 Sterilization / Sanitization Temperature : 0-121 19 Length Of The Sensor Required : 40Cm 20 Cable Length : 2 Mtr 21 Lower Detection Limit : 10Mbar Pco2 22 Membrane Material : Silicone Reinforced / Ptfe 23 Temperature Range:0-60°C 24 Measuring Principle : Potentiometric 25 O Ring Material : Vitron, Silicone ( Fda Compliant ) 26 Known Interference : So2, Nh3, H2s 27 Transmitter Specifications 28 2-Wire / 4-Wire : 4-Wire 29 Area Of Classification : Atex Category 30 Pipe Mounting / Panel Mounting : Pipe 31 Power Supply Ac / Dc : Dc 32 No.Of Outputs: 5 33 Relay Contacts Required / Not Required : Required 34 1 / 2 Din ( 150 / 150Mm ) Or 1 / 4 Din ( 90 / 90Mm ) 35 Housing 36 Insertion Through- Dip Pipe / Recirculation Line / Npt Side Mounting: Recirculation Line : Recirculation Line 37 Moc Of The Housing : Yes 38 Palletizer Machine 39 Body Material : Hardened Mild Steel 40 Volume Palletizer : 120 Ltr 41 Hopper Volume Pallete Machine : 30 Ltr 42 Capacity Of Palletizer : 150 Kg Per Hour 43 Capacity Of Pellete Making : 100 Kg Per Hour 44 Pellete Size Diameter : 10Mm – 12Mm 45 Pellet Size Length ( Inch ) : 1² To 2² 46 Voltage : 415 V 47 Motor Power Palletizer : 10 Hp 48 Motor Power Pellet Machine : 10 Hp 49 Weight ( Kgs ) Palletizer : 150 Kg 50 Weight ( Kg ) Pellete Machine : 250 Kg 51 Shredder Machine 52 Cutting Mechanism : Twin Shaft 53 Shred Chamber ( Mm ) : 310×310 54 Shred Size ( Mm ) : 8×50-100 55 Shred Capacity : 300-500 Kg / Hr 56 Voltage : 415V 57 Power : 3 Hp 58 Hopper Volume ( Liters ) : 60 L 59 Waste Volume ( Liters ) : 180 L 60 Weight ( Kgs ) : 275 61 Machine Dimension ( Mm ) H×W×D : 1770×700×700 62 Over Load Protector : Yes 63 Over Heat Protector : Yes 64 Motor Start / Off : Auto / Online 65 Working Cycle : Continuous 66 Noise Level : <65Db 67 Hplc Guard Column 68 Cation H Refill, 30×4.6Mm, No. 1250129 Nguard Column: With Ionic Form H+ / Co3 - Deashing Guard Column ( 30× 4.6 Mm Guard Column, Lead Form Ph Ranges 5-9, For Aminex Hpx-87P Column ) 69 Carbo-P Refill, 30×4.6Mm No. 1250119 Nguard Column: 30 × 4.6 Mm, Guard Column, Hydrohen Form, Ph Range 1-3, For Aminex Hydrogen Form Columns 70 Lab Wiley Grinder Or Wiley Mill 71 The Unit Has Two Stationary Steel Blades And Rotary With Steel Edges Provided In The Cast Iron Chamber. 72 A Removable Safety Glass Sheet Plate Is Used From The Face Of Chamber To Permit Observation During Operation 73 Willey Mill Is Fitted On Substantial Cast Iron Base. 74 Complete Unit Supplied With Aluminum / Cast Chamber, Polished Hopper With Cover, Wooden Plunger, Three Delivery Tubes Mounted With Sieves Cloth Mesh No; 20, 40, And 60Mesh 75 One Allen Key For Adjusting Blades And 3 Glass Jars, Brush Etc. Electrically Operated To Work On 220 Volts A.C 76 Working Chamber : 100 Mm X 50 Mm 77 Motor: ½ Hp, Chamber Made Of Stainless Steel. 78 Portable Gas Analyser ( Syn-Gas ) 79 Method Of Detection : Ndir Infrared Sensor For Co, Co2 And Ch4 Electrochemical Sensor For O2 & H2 80 Ranges Available No2 0-25.0%, 0-50.0%, 0-100.0% Nco 0-10.0%, 0-50.0%, 0-100.0% Nco2 0-10.0%, 0-50.0%, 0-100.0% Nch4 0-50.0%, 0-100.0% Nh2 0-5.0% 81 Resolution : 0.1% For All Gases 82 Accuracy & Repeatability : ± 2% Of Reading For All Gases 83 Drift : Less Than 2% Of Full Scale Per Month 84 Response Time ( T-90 ) : 20-30 Seconds To 90% Step Change 85 Ambient Temperature Range : 4 To 50°C 86 Power : 12V / 24V Dc Adaptor 87 Output Options : Rs 232 Interface For Data Logging

Key Value

Document Fees
INR 1 /-
EMD
INR 1.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Supply of Instruments/Equipments
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Flow Meter 1 No
2 1.01 Size : 40- 100 mm
3 1.02 Flow range : 25- 250ml/mnt
4 1.03 Volume per revolution : 0.309L
5 1.04 Greatest pressure : 2.5 mpa
6 1.05 Accuracy : ±0.2%
7 1.06 Repeatability : =0.05%
8 1.07 Standard unit : Rise
9 2 CO2 Probe 1 No
10 2.01 Application - Water/Chemical : Both
11 2.02 Nature of the Chemical(High Alkali/Hydrofloric acid/Organic/Inorganic) : Alkali with organic and inorganic
12 2.03 MOC of the Sensor Required : Yes
13 2.04 Where to be mount Pipe/Vessel : Vessel
14 2.05 Top Mounting/Side Mounting : Top
15 2.06 Mounting facility-Flange/NPT etc., Specified : NPT
16 2.07 Operating Temperature : 0-121
17 2.08 Operating Pressure : 0-20
18 2.09 Sterilization/Sanitization Temperature : 0-121
19 2.1 Length of the Sensor required : 40cm
20 2.11 Cable length : 2 mtr
21 2.12 Lower detection limit : 10mbar pCO2
22 2.13 Membrane material : Silicone reinforced/PTFE
23 2.14 Temperature range:0-60°C
24 2.15 Measuring principle : Potentiometric
25 2.16 O ring material : Vitron, silicone (FDA compliant)
26 2.17 Known interference : SO2,NH3, H2S
27 2.18 Transmitter Specifications
28 2.19 2-Wire/4-Wire : 4-wire
29 2.2 Area of Classification : ATEX Category
30 2.21 Pipe mounting/Panel Mounting : Pipe
31 2.22 Power Supply AC/DC : DC
32 2.23 No.of Outputs: 5
33 2.24 Relay contacts required/Not Required : Required
34 2.25 1/2 DIN (150/150mm) or 1/4 DIN(90/90mm)
35 2.26 Housing
36 2.27 Insertion through- DIP Pipe/Recirculation line/NPT Side mounting: Recirculation line : Recirculation line
37 2.28 MOC of the Housing : Yes
38 3 Palletizer Machine 1 No
39 3.01 Body Material : Hardened Mild Steel
40 3.02 Volume Palletizer : 120 Ltr
41 3.03 Hopper Volume Pallete Machine : 30 Ltr
42 3.04 Capacity of Palletizer : 150 Kg per hour
43 3.05 Capacity of Pellete Making : 100 Kg per hour
44 3.06 Pellete Size Diameter : 10mm – 12mm
45 3.07 Pellet Size Length (Inch) : 1² to 2²
46 3.08 Voltage : 415 V
47 3.09 Motor Power Palletizer : 10 HP
48 3.1 Motor Power Pellet Machine : 10 HP
49 3.11 Weight (KGS) Palletizer : 150 kg
50 3.12 Weight (KG) Pellete Machine : 250 Kg
51 4 Shredder Machine 1 No
52 4.01 Cutting Mechanism : Twin Shaft
53 4.02 Shred Chamber (mm) : 310×310
54 4.03 Shred Size (mm) : 8×50-100
55 4.04 Shred capacity : 300-500 Kg/Hr
56 4.05 Voltage : 415V
57 4.06 Power : 3 HP
58 4.07 Hopper Volume (Liters) : 60 L
59 4.08 Waste Volume (Liters) : 180 L
60 4.09 Weight (KGS) : 275
61 4.1 Machine Dimension (mm) H×W×D : 1770×700×700
62 4.11 Over Load Protector : Yes
63 4.12 Over Heat Protector : Yes
64 4.13 Motor Start / Off : Auto / Online
65 4.14 Working Cycle : Continuous
66 4.15 Noise Level : <65DB
67 5 HPLC Guard Column 1 No
68 5.01 Cation H Refill, 30×4.6mm, No. 1250129\nGuard column: with ionic form H+ /CO3 - deashing guard column (30× 4.6 mm guard column, lead form pH ranges 5-9, for Aminex HPX-87P column)
69 5.02 Carbo-P Refill, 30×4.6mm No. 1250119\nGuard column: 30 × 4.6 mm, guard column, hydrohen form, pH range 1-3, for Aminex hydrogen form columns
70 6 Lab Wiley Grinder or Wiley Mill 1 No
71 6.01 The unit has two stationary steel blades and rotary with steel edges provided in the cast iron chamber.
72 6.02 A removable safety Glass sheet plate is used from the face of chamber to permit observation during operation
73 6.03 Willey Mill is fitted on substantial Cast iron base.
74 6.04 Complete unit supplied with aluminum / Cast chamber, polished hopper with cover, wooden plunger, three delivery tubes mounted with sieves cloth mesh no; 20, 40, and 60mesh
75 6.05 One Allen Key for adjusting blades and 3 Glass Jars, brush etc. Electrically operated to work on 220 Volts A.C
76 6.06 Working chamber : 100 mm x 50 mm
77 6.07 Motor: ½ hp, Chamber made of stainless steel.
78 7 Portable Gas Analyser (Syn-Gas) 1 No
79 7.01 Method of Detection : NDIR infrared sensor for CO, CO2 and CH4 Electrochemical sensor for O2 & H2
80 7.02 Ranges Available\nO2 0-25.0%, 0-50.0%, 0-100.0%\nCO 0-10.0%, 0-50.0%, 0-100.0%\nCO2 0-10.0%, 0-50.0%, 0-100.0%\nCH4 0-50.0%, 0-100.0%\nH2 0-5.0%
81 7.03 Resolution : 0.1% for all gases
82 7.04 Accuracy & Repeatability : ± 2% of reading for all gases
83 7.05 Drift : Less than 2% of full scale per month
84 7.06 Response Time (T-90) : 20-30 seconds to 90% step change
85 7.07 Ambient Temperature Range : 4 to 50°C
86 7.08 Power : 12V/24V DC adaptor
87 7.09 Output Options : RS 232 interface for data logging