Electrical Non Schedule Items Cost Of Proposed 100 Mt Cold Rooms And 10 Mt Ripening Rooms
Tender Overview
Project Description
Electrical Non Schedule Items Cost Of Proposed 100 Mt Cold Rooms And 10 Mt Ripening Rooms-Ht Switchgear , Transformer , Diesel Generating Set Of 125Kva Rating Silent Type Radiator , Single Phase Exhaust Fan With Louvres Complete , 1200 Mm Dia Ceiling Fan Complete , Servo Motor Operated Automatic Line Voltage , Puf Insulation Panel , Cold Room Floor With, Insulation Material- Puf Slab Of 100Mm Thickness ,Cold Room Doors (for positive temp), etc
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Mar-2021 | DATE | Date | 23-Mar-2021 |
BOQ
| Name of Work: ELECTICAL NON SCHEDULE ITEMS COST OF PROPOSED 100 MT COLD ROOMS AND 10 MT RIPENING ROOMS | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | HT SWITCHGEAR\nSupply, erection,testing and commissioning of 11KV ,3Ph,50Hz,350 MVA,630 Amps,outdoor type 1 VCB panel H.T.Control panel comprising of 1 VCB fabricated out of 2 mm cold rolled mild steel.metal clad,free standing totally enclosed cubicle type,fully compartmentalised & suitable for operation on 11 KV,3 Phase,50 hz AC earthed system and comprising of the following as per the details spectifications below:\nVCB panel consisting of :\na. 3P vacuum circuit breaker,horizontal drawout,horizontally isolated type, 630 Amps, 350 MVA.11 KV, 26.3 KA with all standard accessories fitted with, shunt trip/closing coil,motor:220V/110V AC motor/hand operated mechnism and operation counter-1no.\nb. Non lockable breaker control (TNC) switch with twistle grip handle and spring return to neutral-1 set.\nc. 3P, Non directional IDMT 30/c, 1 E/F relay with instantaneuous elements MC 31A-1 set.\nd. Resin cast CT's 15/7.5 VA classs 1-3 nos.\ne. Resin cast PT's, 3P,100VA class 1-3nos.\nf. Breaker ON/OFF indication lamps-1 set.\ng. Voltmeter with selector swich-1no.\nh. Ammeter with selector swich-1no.\ni. Aluminium busbar,suitable rating 3 Phase,Air insulated with heat shrinkable sleeves-1set.\nj. Eatrth 25X3 mm Tin coated copper busbar-1set.\nk. Busbar supports resin cast with 33KV dielectric and mechanical strength-1 set.\n | BI01010001010000000000000515BI0100001113 | 1 | Nos |
| 2 | 2 | TRANSFORMER\n160 KVA 11KV/433V DYn11 oil emmersed type transformer with off circuit tap links of rating +5% to -5% @2.5%. class of Insulation F with letest IS\n\n | BI01010001010000000000000515BI0100001113 | 1 | Nos |
| 3 | 3 | Supply, Installation, Testing & Commissioning of indoor type Free standing main LT Panel including 56 KVAR capacitor section with following switch gears:-\n400A Changeover Switch 1 No.\n400A 4P MDO ACB with Microprocessor Based Release 2 Nos\nB) I/C-125KVA DG Feeder\n250A(160-250A) 4P MCCB with Microprocessor Release (O/L & S/C) 1 No\nC) Metering Section Feeder\nVoltmeter with Selector Switch 2 Nos\nAmmeter with Selector Switch 2 Nos\nHz Meter 2 No\nPF Meter 1 No\nC.T's (For Metering) 2 set\nC.T's (For Protection) 1 set\nIndication Lamps for Phase (R,Y,B) 3 set\nIndication Lamps for ON,OFF,TRIP Status 1 set\nAuxiliary Contacts 3 nos\nControl Fuse 3 Set\nF) O/G Power Feeders\n100A(25-32A) TPN MCCB with Thermal Magnetic Release (O/L & S/C) 6 Nos\n100A(16-20A) TPN MCCB with Thermal Magnetic Release (O/L & S/C) 10 Nos\nH) 56KVAR Capacitor Section\n7KVAR Capacitor Bank Feeders 8 Nos - Shall have\n32A HRC Fuse With Base 8 Nos\n32A TP Contactor 8 Nos\n7% Detuned Reactors for 7KVAR 8 Nos\n7KVAR Capacitor Bank(Normal Duty) 8 Nos\nIndication Lamps for ON,OFF Status 8 Set\nPush Buttons for START,STOP 8 Set\nAuto-Manual Switch 8 Nos\nI) Busbar Chamber\nBusbar-1 = 400A Aluminium Busbar Electrolytic Grade\nBusbar-2 = 200A Aluminium Busbar Electrolytic Grade\n | BI01010001010000000000000515BI0100001114 | 1 | Nos |
| 4 | 4 | Supply, installation, testing & commissioning of Diesel Generating Set of 125KVA rating Silent Type Radiator type, suitable for of 415V, 3 phase 4 wire, 0.8 pf. (lagging) 50c/s A.C supply complete with engine (1500 RPM) and alternator DG Set controller with accessories including residential type silencer and manual control panel fuel service tank as per standard, battery and battery charger with all associated accessories including MCCB of suitable rating & standard set of tools and anti-vibration mounting pads etc. The specification shall be as per GEM specification attached. The instalation, testing, commissioning shall be done as per GEM. | BI01010001010000000000000515BI0100001115 | 1 | Nos |
| 5 | 5 | Supply of 12\" (300mm) dia (900 rpm) single phase Exhaust fan with louvres complete as required. | BI01010001010000000000000515BI0100001116 | 1 | Nos |
| 6 | 6 | Supply of 1200 mm dia ceiling fan complete as required Crompton or equivalent as per approved makes. | BI01010001010000000000000515BI0100001118 | 1 | Nos |
| 7 | 7 | Supply, installation, testing, commissioning of Servo motor operated automatic line voltage correctors copper bound indoor type, continuous duty, conforming to IS9815(Part 1)/1994 (Reaffirmed 2009) suitable for Phase voltage of 120-280V. 3 Phase line voltage corrector shall comprise of 3 single phase line voltage correctors conforming to IS 9815 (Part 1)/1994(Reaffirmed 2009), connected in star and enclosed in a single enclosure with common control panel and shall be suitable for unbalanced input voltage. Rate output voltage shall be 240V for single phase LVC and 415V for 3 phase LVC respectively. Rating 3 x 60 KVA 3 Phase, 3PH, 50 Hz. | BI01010001010000000000000515BI0100001119 | 1 | Nos |
| 8 | 8 | Supply and fixing of PUF Insulation panel of thickness of 100 mm, for Cold Room walls & ceiling including Common walls inclusive of all accessories as per specification for 05 Nos of Cold Room with 100 MT capacity (Dimenssion - 16.0x6.1x3.5 mtr) , 04 Nos Ripening Chmber with 10 MT capacity (Dimenssion - 7.5x4.3x3.5). Make - Lloyd insulation, Sintex, Rinac, Jindal, BNAL (PUF Panel Thickness \nCold Room - 100 mm (walls) 100mm (ceiling)\nAnte Chamber - 100mm (walls & ceiling)\nb) Density - 40 +/- 2 Kg/M3\nc) Closed cell content - 90 - 95%\nd) Thermal Conductivity - 0.023 W/mK\ne) Compressive Strength - 2.1 kg/ m2 (at 10% deformation)\nf) Water Vapour Permeability - 0.8 -.12 gms/hr m2\ng) Fire Resistance - Self extinguishing\nh) Blowing Agent - CFC Free\ni) Sheet - 0.5 mm TCT, PPGI)\n\n | BI01010001010000000000000515BI0100001120 | 1 | Nos |
| 9 | 9 | Supply and fixing of Cold Room Floor with, Insulation Material- PUF slab of 100mm thickness( in 2 layers of 50 mm each), Vapour Barrier, inclusive of all accessories as per specification. Make - Lloyd Insulation, Sintex, Rinac, Jindal, BNAL, Industrial Foam. (a) Insulation Material - PUF slab\nb) Density - 40 +/- 2 Kg/M3\nc) No. of Layers - 2 layers ( 40 mm each)\nd) Total Thickness - 80 mm\ne) Vapor Barrier - Tarfelt, Polythene Sheet as per dwg\nf) VDF floor - VDF as per dwg)\n | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 10 | 10 | Supply and Installation of Cold Room Doors (for positive temp) insulated type of Horizontal Manual Sliding Door, Dimensions -1500 mm x 2100mm ( clear) with Sandwich panels constructed of a core of 80 mm PUF complete with all accessories as per specification Make - Metaflex, lloyd insulation, Rinac, Hormann, Gandhi Automation (a) Type of Door - Manual Sliding Door\nb) Dimensions - 1500 X 2100MM\nc) Type of panel - Sandwich panels constructed of a core of 100 mm\nPUF on both sides covered with 0.6 mm galvanized steel plate finished with 20mucoating. The panels are supplied with thermal bridge-free PVC surrounding profiles\nd) Sealing - All round with triple rubber profile\ne) Colour outside - RAL 9002 (white)\nf) Colour inside - Standard colour RAL 9002 (white/grey)\ng) Hardware - Galvanised Steel\nh) Track Rail - Drop/Lift rail system\ni) Finish of opening - To be Included\nj) Door Operation - Manual)\n | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 11 | 11 | Supply, Installation, Testing, Commissioning of Refrigeration system of suitable capacity (reference capacity 27kw for each room) complete with all spares as per specification for each of 5 nos cold rooms be provided with Freon 404A based refrigeration system to cater to therefrigeration design load.1. DESIGN TEMP: EVAPORATION -7.5 DEG C, CONDENSING 53.5 DEG C2. COMPRESSOR – SEMI HERMETIC (1 PER COLD ROOM)3. AIR COOLED CONDENSER, AIR VOLUME 10400 M3/HR, FANS TO BE CONTROLLED BY TEMP CONTROLLER , SUCTION 15/8”, LIQUID 7/8”. TYPICALDIMENSIONS : 1591MM (LENGTH) X 998MM (HEIGHT) X 1000MM (DEPTH) (MAKES- BITZER, BOCK, FRASCOLD, CARRIER)4. COOLERS OF CAPACITY 27 KW (1 PER COLD ROOM. WITH 3 AXIAL FANS OF 450MM, 19200 M3/HR, FIN SPACING 4 FIN/ SQ. INCH (MAKES – LUVE, PATTON,GUNTNER, STAR COOLER) – TYPICAL DIMENSIONS : 3500MM (LENGTH) X 655MM (HEIGHT) X 675MM (DEPTH)5. VENTILATION FAN 450MM6. CONTROLS, THERMOSTAT, SOLENOID VALVE, VALVE, SIGHT GLASS7. CONTROL PANEL FOR EACH ROOM AT REAR SIDE OF COLD ROOM CONTROL PANEL (PLC CONTROLS TYPE) TO HAVE FOLLOWING FEATURES – STARTINGARRANGEMENT FOR COMPRESSOR (HP/LP/OP CUT OUT FOR EACH COMPRESSOR) CONTRACTOR FOR CONDENSER FAN, THERMOSTATIC CONTROLLER FROM DANFOSS FOR CONTROLLING THE FAN, CRANKCASEHEATER TO OPERATE WHEN COMPRESSOR IS STOPPED AND OFF WHENRUNNING. LIGHTING MAIN SWITCH ALSO IN THE PANEL. THIS WILL HAVE ALL STARTERS WITH INTERLOCKING SYSTEM. PUSH BUTTONS FOR START/STOP. HUMIDIFIER & ETHYLENE SCRUBBER SWITCHES ALSO IN THE PANEL. OVERLOAD RELAYS & FUSES, NAME PLATES | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 12 | 12 | Supply, Installation, Testing & Commissioning of Ultrasonic type humidification system in all Cold rooms with automated controls capable of providing 90 - 95% RH in each room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, , complete with all connections in all rooms as per specification - The humidification system offered should be ltrasonic type humidification system in all Cold rooms with automated controls capable of providing 90 - 95% RH in each cold room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, complete with all connections in all rooms as per specification | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 13 | 13 | Supply, Installation, Testing & Commissioning of Ethylene Scrubber system in each Cold Room to allow for mixed storage of fruits and vegetables to protect product quality during storage due to ethylene, system should be suitable for cold room with panel counter for energy consumed, programmable hours of operation etc in each of cold rooms as per specification Make- Bioconservacion, Miatech, Ethylene Control (Air purification and ethylene scrubber system should be installed in each Cold Room to allow for mixed storage of fruits and vegetables to protect product quality during storage due to ethylene and airborne pathogens. The system should be suitable for cold room with use of specialized granules for air filtration, airborne pathogen and ethylene removal system.)\n | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 14 | 14 | Supply, Installation, Testing, Commissioning of Refrigeration System of suitable capacity (reference capacity16.00 kw for each room) complete with all spares as per specification for each of 4 nos ripening rooms. Make - Carrier, Rinac, Blue Star, Voltas (1. DESIGN TEMP: EVAPORATION -5 DEG C, CONDENSING 54 DEG C\n2. COMPRESSOR – SEMI HERMETIC (1 PER RIPENING ROOM)\n3. AIR COOLED CONDENSER, AIR VOLUME 20000 M3/HR, 10 FINS/INCH, 1 AXIAL FAN TO BE CONTROLLED BY THERMOSTATIC CONTROL UNIT WITH OUTSIDE TEMP SENSING ARRANGEMENT . TYPICAL DIMENSIONS : 1000MM (LENGTH) X 837MM (HEIGHT) X 672MM (DEPTH (MAKES- CARRIER, RINAC, BLUE STAR, VOLTAS)4. DUAL DISCHARGE COOLER OF CAPACITY 11KW ( 1 PER RIPENING ROOM. WITH 5 AXIAL FANS OF 450MM, AIR VOLUME 20000 M3/HR, FIN SPACING 5 FIN/SQ. INCH\nTYPICAL DIMENSIONS : 2500MM (LENGTH) HEIGHT OF INDIVIDUAL COIL 325MM(MAKES- CARRIER, RINAC, BLUE STAR, VOLTAS)\n5. VENTILATION FAN 15”, 6. CONTROLS , DRYER, THERMOSTAT, THERMOSTATIC EXPANSION VALVE, SOLENOID VALVE, VALVE, SIGHT GLASS\n7. SENSORS & ALLIED EQUIPMENT PER ROOM -ETHYLENE SENSOR (1), CO2 SENSOR (1), PULP TEMPERATURE (1 ), VENTILATION SYSTEM CONNECTED TO DAMPER & VENTILATION FAN (1 EACH)\n8. PIPING – SUCTION 11/8” AND LIQUID LINE ½” WITH INSULATION\n9. CONTROL PANEL FOR EACH ROOM AT REAR SIDE OF RIPENING ROOM, 10. CONTROL PANEL (PLC CONTROL TYPE) TO HAVE FOLLOWING FEATURES – STARTING ARRANGEMENT FOR COMPRESSOR (HP/LP/OP CUT OUT FOR EACH COMPRESSOR) CONTRACTOR FOR CONDENSER FAN, THERMOSTATIC CONTROLLER FROM DANFOSS FOR CONTROLLING THE FAN, CRANKCASE, HEATER TO OPERATE WHEN COMPRESSOR IS STOPPED AND OFF WHEN RUNNING. LIGHTING MAIN SWITCH ALSO IN THE PANEL. THIS WILL HAVE, ALL STARTERS WITH INTERLOCKING SYSTEM. PUSH BUTTONS FOR START/STOP. HUMIDIFIER & ETHYLENE GENERATOR SWITCHES ALSO IN THE PANEL. OVERLOAD RELAYS & FUSES & NAME PLATES\n | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 15 | 15 | Supply, Installation, Testing & Commissioning of Ultrasonic type humidification system in all Ripening rooms with automated controls capable of providing 90 - 95% RH in each Ripening room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, complete with all connections in all rooms as per specification - The humidification system offered should be Ultrasonic type humidification system in all Ripening rooms with automated controls capable of providing 90 - 95% RH in each room to ensure uniform humidity in the room, system should be complete with RH control sensor and digital display for monitoring and control of RH in each room, , complete with all connections in all rooms as per specification. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 16 | 16 | Supply, Installation, Testing and Commissioning of Portable Ethylene Generator connected to an electrical plug point inside the room, the Ethylene Generator should be suitable for providing suitable levels of ethylene (as per the fruit category) in ripening rooms of volume around 60 cum by catalytic dehydration of developing liquid into ethylene gas complete with suitable developing liquid required for commercial ripening applications for each of the ripening rooms as per specification alongwith 5 ltr of developing liquid ethylene with each generator. Make- Aseko, Catalytic, American Ripener (The provision for Ethylene Gas dosage for ripening in each room shall be by placing a Portable Ethylene Generator connected to an electrical plug point inside the room. The Ethylene Generator should be suitable for providing suitable levels of ethylene (as per the fruit category) in ripening rooms of volume around 58 cum by catalytic dehydration of developing liquid into ethylene gas complete with suitable developing liquid required for commercial ripening applications.) | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 17 | 17 | Supply, Installation, Testing and Commissioning of Ethylene Gas sensor complete with display in all 4 Ripening Rooms of catalytic type with measuring range upto 2000 ppm for ripening room application as per specification. Make- Aseko, Carel | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 18 | 18 | Supply, Installation, Testing and Commissioning of CO2 gas sensors complete with display in all 4 Ripening Rooms of infrared type with measuring range 0 – 5% suitable for ripening application as per specification. Make- Aseko, Carel | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 19 | 19 | Supply, Installation, Testing and Commissioning of Air Ventilation Systems connected with gas control system for all Ripening Rooms suitable for ripening application as per specification | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 20 | 20 | Supply, Installation, Testing and Commissioning of Ripening Controller system sensors for integration and control of all ripening activities suitable for minimum 4 ripening rooms with display & all accessories (Make: Aseko, Interko, Felix) | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 21 | 21 | ISupply and fixing of PUF Insulation panel of thickness of 40 mm having Density 40 kg/cu.m (+/- 2), 0.5 mm thick PPGI sheet, thermal conductivity [ 0.023 W/mK], for ceiling at loading, unloading and Admin area (3.5 mtr. Hight from floor level) inclusive of all accessories and installation as per specification. Make - Lloyd Insulation, Sintex, Rinac, Jindal | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 22 | 22 | Supply, Installation, Testing and Commissioning of Platform weighscale of electronic digital type of 200 kg capacity as per specifications Make - Kantawala, Swastik, Dewlite, Avery (a) Capacity 200 Kg\nb) Pan Size & MOC 400mm X 500mm minimum (of SS) for 200 kg\ne) Least Count 20 gm maximum for 200 kg \nh) 100% Tare through Keyboard\ni) Stamping to be provided)\n | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 23 | 23 | Supply, Installation, Testing and Commissioning of Plastic crates of outer dimensions 540mm x 360mm x 290mm (48 ltr capacity) for storage of around 20 kg vegetables (side perforated type) made of HDPE 100% virgin material as per specifications | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 24 | 24 | Supply, Installation, Testing and Commissioning of hand pallet truck with 2500 kg lifting capacity as per specification Make - Godrej, Voltas, Mahindra, Jay, Maini (a) Load Capacity : 2500 mm\nb) Fork Length : 1100 mm\nc) Fork Width : 150 mm\nd) Out Side Fork Spread : 550 mm\ne) Inside Fork Spread : 250 mm\nf) Maximum Fork Height : 185 mm\ng) Minimum Fork Height : 75 mm)\n | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 25 | 25 | Supply, Installation, Testing and Commissioning of Plastic Pallet of size : 1200 x 1000 x 150 mm with 4 way entry HDPE 100% virgin material | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 26 | 26 | Providing preventive maintenance, repair, replacement for all equipment for a period of 4 years after warranty period | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 27 | 27 | Providing skilled manpower in two shifts one no. in each shift for the Management of proposed cold room and ripening facility. The agency will be responsible for the management of facility in terms of accounting and etc for the first year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 28 | 28 | Providing skilled manpower in two shifts one no. in each shift for the Management of proposed cold room and ripening facility. The agency will be resposible for the management of facility in terms of accounting and etc for the 2nd year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 29 | 29 | Providing skilled manpower in two shifts one no. in each shift for the Management of proposed cold room and ripening facility. The agency will be resposible for the management of facility in terms of accounting and etc for the 3rd year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 30 | 30 | Providing skilled manpower in two shifts one no. in each shift for the Management of proposed cold room and ripening facility. The agency will be responsible for the management of facility in terms of accounting and etc for the 4th year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 31 | 31 | Providing skilled manpower in two shifts one no. in each shift for the Management of proposed cold room and ripening facility. The agency will be responsible for the management of facility in terms of accounting and etc for the 5th year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 32 | 32 | Providing skilled manpower in two shifts one no. in each shift for the Operation of proposed cold room and ripening facility. The agency will be responsible for the Operation of facility in terms of suitable Technical manpower and etc for the first year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 33 | 33 | Providing skilled manpower in two shifts one no. in each shift for the Operation of proposed cold room and ripening facility. The agency will be responsible for the Operation of facility in terms of suitable Technical manpower and etc for the 2nd year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 34 | 34 | Providing skilled manpower in two shifts one no. in each shift for the Operation of proposed cold room and ripening facility. The agency will be responsible for the Operation of facility in terms of suitable Technical manpower and etc for the 3rd year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 35 | 35 | Providing skilled manpower in two shifts one no. in each shift for the Operation of proposed cold room and ripening facility. The agency will be responsible for the Operation of facility in terms of suitable Technical manpower and etc for the 4th year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 36 | 36 | Providing skilled manpower in two shifts one no. in each shift for the Operation of proposed cold room and ripening facility. The agency will be responsible for the Operation of facility in terms of suitable Technical manpower and etc for the 5th year at the 9.66% incremental cost from previous year. | BI01010001010000000000000515BI0100001121 | 1 | Nos |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender