Military Engineer Services-MES has published Provision Of Raising Height Of Security Wall With Y Angle And Concertina Coil At Certain Locations At Hqtc ( U ) . Submission Date for this Tender is 01-05-2021. Wall construction Tenders in GE AF BANGALORE Karnataka. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 20-Mar-2021 | Postponement | Date | 12-04-2021 |
2 | 25-Mar-2021 | Postponement. | Date | 20-04-2021 |
3 | 15-Apr-2021 | Revised BOQ and Amendment | BOQ | 20-04-2021 |
4 | 15-Apr-2021 | Postponement15Apr21 | Date | 24-04-2021 |
5 | 16-Apr-2021 | Amendment to PS | Technical Bid | 24-04-2021 |
6 | 20-Apr-2021 | Amendment tender docu | Technical Bid | 24-04-2021 |
7 | 24-Apr-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 01-05-2021 |
Name of Work: PROVISION OF RAISING HEIGHT OF SECURITY WALL WITH ‘Y’ ANGLE AND CONCERTINA COIL AT CERTAIN LOCATIONS AT HQTC(U). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dresses stonework and precast concrete articles. | BI01010001010000000000000515BI0100001113 | 616 | Cum |
2 | 2 | Demolition cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for | BI01010001010000000000000515BI0100001114 | 98 | Cum |
3 | 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for | 53 | Per Qtl | |
4 | 4 | Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foudation etc, or for shafts, wells cesspits, manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil. | 450 | Cum | |
5 | 5 | Excavating in trenches, n exc 1.5m wide and exc 1.5m in depth, for foudation etc, or for shafts, wells cesspits, manholes, pier holes etc n exc 10 sqm on plan and exc 1.5m and n.exc 3 m in depth and getting out in soft/loose soil. | 40 | Cum | |
6 | 6 | Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as directed. | BI01010001010000000000000515BI0100001115 | 485 | Cum |
7 | 7 | Removing excavated material exe 250m but n.exe 500m and upto total distance of 1.5 km depositing where directed. | BI01010001010000000000000515BI0100001116 | 5 | Cum |
8 | 8 | M & L cement concrete type D-2, 1:4:8, using 40mm graded aggregate as in foundations, fillings and mass concrete. | 60 | Cum | |
9 | 9 | M&L MS TMT bars 10 mm dia and over cut to length bent to shape required including cranking bending and binding with MS wire annealed not less than 0.9 mm dia all as specified and as directed | 16600 | KG | |
10 | 10 | All as per item No 9 above but 6 to 8mm dia | 1125 | KG | |
11 | 11 | All as per item No 9 above but 5 to 10mm dia as in stirups | 9785 | KG | |
12 | 12 | M&L for form work to sides of concrete foundations footings bases of columns and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to batter. | 225 | Sqm | |
13 | 13 | M&L for reinforced cement concrete type B1-1:2:4 (20mm graded aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns etc | 86 | Cum | |
14 | 14 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete. | 620 | Sqm | |
15 | 15 | M&L for reinforced cement concrete type B1-1:2:4 (20mm graded aggregate) as in columns, pillars, piers, posts and struts | 48 | Cum | |
16 | 16 | M&L for form work to sides and suffits of floor or roof beam, beam haunchings, girders, bressumers, lintels, cantilevers, shelves, including supports overhangs, etc finished rough in flat surface. | 1420 | Sqm | |
17 | 17 | M&L for reinforced cement concrete type B1-1:2:4 (20mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span | 120 | Cum | |
18 | 18 | M&L for Pre-cast cement concrete block type C1 1:3:6 (20mm graded stone aggregate) masonry with solid blocks, exc. 10cm in width and setting in mortar 1:6 complete. | 270 | Cum | |
19 | 19 | M&L for rendering 15mm thick cement plaster in cement morter 1:4 with water proofing compound as per manufacture instruction, on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement. | 3560 | Sqm | |
20 | 20 | Supply only integral water proofing compound, complete all as specified | 196 | Ltr | |
21 | 21 | M&L for preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer. | 3560 | Sqm | |
22 | 22 | S&F framed work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat/ angle iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including embeding in concrete and screwing etc. wind ties for roof including securing bolts; | 10250 | KG | |
23 | 23 | M&L for two coats of synthetic enamel paints over a coats of red oxide primer including prepration of new steel surfaces of any description over 10 cm in width or girth not otherwise described | 465 | Sqm | |
24 | 24 | S&F in repairs galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) | 140 | 100 Rm | |
25 | 25 | S&F in repairs concertina coil of gauge 2.6mm and using coil of 61 cm dia of approved make coil over MS angle brackets all as specified. | 1400 | Rm | |
26 | 26 | S&F PVC (SWR) 110 mm dia pipes single socketed, in any length with rubber ring joints, laid as in trenches or as in weep holes of retaining wall etc. | 600 | RM | |
27 | 27 | M&L for broken glass coping on top of walls in CM 1:3 | 300 | Sqm |