MEHLANA: PROVIDING CANAL BASED WATER WORKS, FUNCTIONAL HOUSEHOLD TAP CONNECTIONS & LAYING THE BALANCE PIPE LINES IN VILLAGE DISTT. SONIPAT Design, construction, testing & commissioning of 0.50 MLD capacity water treatment plant, construction of Sump wells, S&S tank, pump chamber, clear water tank, Boundary wall, C.C roads, providing functional household tap connections, laying the balance pipe lines in village. Supply, erection, testing & commissioning of, Raw & Clear water pumping machinery, 1 no. electric Transformer of required capacity. O&M for 12 months during defect liability period after trail run of 3 month and 5 year thereafter & all other works contingent thereto”. Rs. 172.35 Lacs | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | WATER TREATMENT PLANT (WTP)\nDesign, construction, testing & commissioning of 0.50 MLD capacity Water treatment plant including inlet channel, Alum dozing, Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank including all civil work, pumping machineries and electric cabling, control panels, entire piping network of suitable size DI pipe from raw water pump to inlet box of WTP, WTP to CWT & Suction Well for CW including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (Sluice valves of make IVC/VAG) . \n\n\n | 1 | Per Job (0.50 MLD) | |
2 | 2 | RAW WATER PUMPING MACHINERY\nSupply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame-WATER WORKS MEHALANA- 500 LPM X 12.50 M. Head\n\n | 4 | Each | |
3 | 3 | CLEAR WATER PUMPING MACHINERY-Supply & Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame- WATER WORKS MEHLANA - 3.1.1- 1100 LPM X 45 M. Head | 2 | Each | |
4 | 4 | PANEL BOARDS FOR MOTORS Supply, erection, testing & commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items -(4.1)-For 2 no Pumping Sets of 500 LPM x 12.5 m Head\na) Main switch 63 amp. 1 No. (L&T Siemens, ABB)\nb) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T)\nc) Digital Multi function meter = 1 No.\nd) SPP = 1 No. of approved make\ne) Motor starter, Star delta for 500 LPM x 12.5 m Head = 2 Nos (L&T Siemens, ABB)\nf) VSS 1 No. & ASS 2 Nos. of approved make.\ng)Capacitor KVAR as per site requirement = 1 No.\nh) Indicating Lamp = One Set\ni) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 2.1.1 \n\n\n\n | 2 | Per Job | |
5 | 5 | (4.2)-For 2 no Pumping Sets of 1100 LPM x 45 m Head \na) Main switch 63 amp. 2 No. (L&T Siemens, ABB)\nb) CT 100/3 = 2 Nos. (AE/ KAPPA/ L&T)\nc) Digital Multi function meter = 1 No.\nd) SPP = 1 No. of approved make\ne) Motor starter, Star delta for 1100 LPM x 45 m Head = 2 Nos (L&T Siemens, ABB)\nf) VSS 1 No. & ASS 2 Nos. of approved make.\ng)Capacitor KVAR as per site requirement = 1 No.\nh) Indicating Lamp = One Set\ni) Change over switch of suitable Amp = 1 No. (Each) Ref. sr. no. 3.1.1\n\n\n\n\n\n | 1 | Per Job | |
6 | 6 | Supply, erection, testing & commissioning of IS marked copper wire for various motors with underground system in PVC and flexible pipes copper wire 3 core complete in all respevts with accessories like thimble etc.- 10mm 2 core | 20 | Per Mtr. | |
7 | 7 | 25mm2 3 Core | 200 | Per Mtr. | |
8 | 8 | Sluice Valves / NRV & specials for Pumping Machinery- Supplying, fixing, jointing, testing & commissioning of DI sluice valves resilient sheet P.N. 1.6 including cost of jointing material complete in all respect. (IVC / VAG make, Kirloskar)- 100mm i/d | 8 | Each | |
9 | 9 | 150 mm i/d | 4 | Each | |
10 | 10 | Supplying,fixing, testing & commissioning of DI swing check type reflux valve (non returned valve) PN 1.6 including cost of jointing material complete in all respect.( IVC / VAG , Kirloskar make) - 100mm i/d | 4 | Each | |
11 | 11 | 150 mm i/d | 2 | Each | |
12 | 12 | Supply, fixing & testing of Mechanical Joints PN 1.6 alongwith ruber gaskit & galvanized nuts / bolts complete in all respect.- 100mm i/d | 8 | Each | |
13 | 13 | 150 mm i/d | 4 | Each | |
14 | 14 | Supply, erection, fixing & testing of DI Double flanged pipe complete with all jointing materials- 100mm i/d | 100 | Per Mtr | |
15 | 15 | 150 mm i/d | 50 | Per Mtr | |
16 | 16 | Supply erection testing and commissioning of exhaust fans each having a capacity of 45 cubic meters per minutes, complete in all respect. | 2 | Per Job | |
17 | 17 | Supply erection & testing of Ceiling fan of size 48" i/d (1200 mm) of reputed ISI make complete in all respect. | 2 | Per Job | |
18 | 18 | Providing and fixing of insulated Rubber matting suitable for HKV installation 1 meter x 2 meter x 12 mm as per specification. | 3 | Each | |
19 | 19 | Providing & fixing suitable size floating along with swivel bend as per required specifications approved by Engineer-in-Charge | 1 | Each | |
20 | 20 | Supply, erection testing & commissioning of caste iron sluice Gate valve of 600 x 600 mm of 20 mm thickness with all acessories along with rising spindle including cost of all jointing material complete in all respect. (IVC / VAG make) for sump well of Raw water pumping station | 1 | Each | |
21 | 21 | Supply erection testing of reputed make LED light 100 wats with fittings and accessories complete in all repects. | 4 | Each | |
22 | 22 | Supply erection testing and commissioning of Flow Meter (KRONE Make) with digital display of 150 mm i/d complete in all respect. | 2 | Per Job | |
23 | 23 | Design, Supply & Erection of copper wound outdoor type Transformers of required KVA as mentioned below on load tap changer or suitable capacity on higher side of standard make outdoor type, VCB Panel, G.O. Switch, H.T. Metering Panels, APFC Panels along with for each Transformer, 11KV Substation, entire cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel, Earthing, safety equipment and any other contingent thereto complete in all respect as per DNIT and getting it passed from Chief Electrical Officer including operation & Maintenance of 5 Years.- At W/W Mehlana 63 KVA | 1 | Per Job | |
24 | 24 | Providing & fixing in position GI elbow ISI marked complete in all respect\n15 mm i/d 618 x 4 = 2,472 \n\n | 2472 | Each | |
25 | 25 | Providing & fixing in position GI Nipple ISI marked complete in all respect\n15mm x150mm /100 mm 618 x 2 = 1,236 \n\n | 1236 | Each | |
26 | 26 | Operation & Maintenance - Operation & maintenance for the complete scope of work mentioned in the DNIT (Disinfection material will be supplied by the PHED) as per schedule-IV during Defect liability period of 12 months after trial run period of 3 months & 5 years thereafter. (Will be charged to A/mtc estimate)." - (i) Defect liability period (Operation Only) | 1 | Per Year | |
27 | 27 | (ii) Operation & maintenance during 1st year | 1 | Per Year | |
28 | 28 | (iii) Operation and maintenance during 2nd year | 1 | Per Year | |
29 | 29 | (iv) Operation and maintenance during 3rd year | 1 | Per Year | |
30 | 30 | (v) Operation and maintenance during 4th year | 1 | Per Year | |
31 | 31 | (vi) Operation and maintenance during 5th year | 1 | Per Year |