| 1 | 1 | Supply, installation, testing, trial run and commissioning of submersible axial flow pump set with the specifications listed below, suitable for handling brackish and silty water with small salt particles, with rpm 960 (Syn) or less. The material of construction of the casing, suction bell shall be CIFG 260 with 2% NICI, impeller SS 316, shaft and sleeve should be SS 316 and vertical submerged column pipe, and delivery pipe (varies from 2 to 6 m length as per site conditions) of SS 304 with 6 mm minimum thickness. A non-corrosive metallic strainer of mesh size not more than 50 mm X 50 mm should be fitted at mouth of suction column. Any hanging portion of the delivery pipe should be supported with suitable metallic supporting frames.\nThe prime mover for the pump should be 3 phase TEWC squirrel cage submersible induction motor suitable for 415 V +/- 10%, 50 Hz +/- 5% connection with class “F” insulation, cubicle type panel board with all necessary protection units and instrumentation. Auto transformer starter of reputed make (SIM insertion type, remote control ), MCCB including suitable metering, LED indications, selector switch, single phase and dry running preventer, suitable capacitor etc., wiring and earthing should be as per regulations and specifications of KSEB and Electrical Inspectorate. Suitable water proof, copper power cable, about 20.00 m length or as per site requirement. A screen with 6 mm GI welded mesh with 50 mm X 50 mm opening size, framed in GI angles and GI tubes shall be fitted at the openings on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. \nThe rate quoted should inclusive all the charges for supply, installation including petty civil works, trial run and commissioning, all type of transport and conveyance, loading and unloading charges, GST etc.\n | | | |
|---|
| 2 | 1.01 | Duty point head 3.25 m, Minimum Discharge at Duty Point Head (Ips): 475, Power Allocation 30 hp Andikkottukadavu (1 No), Kannanchira (2 Nos), Nakkola (1 No) | item1 | 4 | No |
|---|
| 3 | 1.02 | Duty point head 3.25 m, Minimum Discharge at Duty Point Head (Ips): 625, Power Allocation 40 hp Aviyoor (1 No) | item2 | 1 | No |
|---|
| 4 | 2 | Supply, installation, testing and commissioning of end suction mixed flow pump set, with following duty criteria, coupled with suitable electric motor with rpm less than 1000, TEFC, squirrel cage induction motor, fitted on a common base frame, with necessary fittings and couplings. The material of construction of impeller and shaft shall be SS304, and that of pump body is Cast Iron FG 260 with 2% nickel.\na shelter with FRP/GRP portable cabin, corrosion resistant, size suitable with the foot area of the pump and accessories quoted, 10 ft height with one door and two ventilators and with out floor. A pump foundation of size suitable for the weight of pump quoted has to be provided in Cement Concrete 1:3:6 or richer mix.\nFully wired, cubical type MS panel board, consisting of auto star delta starter, MCB, ELCB, LED Indicators, Selector Switch, Fuse units, Single Phase and dry run preventer, Capacitor, earthing etc., as per KSEB norms and safety norms of Electrical Inspectorate.\nThe length of suction pipe is approximately 6 m, 6 mm thick, made of SS 304 including all fittings such as flanges, bends etc. A non return valve should be provided at delivery side. The end of suction pipe be fitted with a Stainless Steel Stainer mesh. Delivery pipe is MS painted with anti corrosive epoxy painting. The portion of suction and delivery pipe line should be supported using suitable metallic/ concrete / masonry structures. the quote should be inclusive of all petty civil works.\nSuitable Vacuum pump with starter and other accessories for priming purpose.\n | | | |
|---|
| 5 | 2.01 | Duty point head 3.25 m, Minimum Discharge at Duty Point Head (Ips): 200, Power Allocation 25 hp | item3 | 6 | Nos |
|---|
| 6 | 2.02 | Duty point head 3.25 m, Minimum Discharge at Duty Point Head (Ips): 160, Power Allocation 20 hp | item4 | 21 | Nos |
|---|
| 7 | 2.03 | Duty point head 3.25 m, Minimum Discharge at Duty Point Head (Ips): 125, Power Allocation 15 hp | item5 | 16 | Nos |
|---|