Jal Jeevan Mission- 2020-21- Laying Distribution Lines And Providing Fhtcs ( 8298 Nos ) In Ongallur Panchayath

Tender Notice

27162071
Corrigendum : Jal Jeevan Mission- 2020-21- Laying Distribution Lines And Providing Fhtcs ( 8298 Nos ) In Ongallur Panchayath
Indian
Kerala
03-04-2021
09-04-2021
12-04-2021

Tender Details

Jal Jeevan Mission- 2020-21- Laying Distribution Lines And Providing Fhtcs ( 8298 Nos ) In Ongallur Panchayath

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Mar-202 date Date 15-03-2021
2 15-Mar-202 Date. Date 25-03-2021
3 26-Mar-202 Time Extension Date 31-03-2021
4 03-Apr-202 Extension of Time Date 09-04-2021

Key Value

Document Fees
INR 16800 /-
EMD
INR 500000.00 /-
Tender Value
INR 21.23 Crore /-

BOQ Items

Name of Work:Jal Jeevan Mission- 2020-21- Supplying , Laying ,testing ,commissioning and maintenance of distribution system from 32 LL GLSR at Plant and providing FHTCs (8298 Nos) in Ongallur panchayath, and Railway track crossing works.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 (A) - CWSS to Ongallur & Vallappuzha Panchayaths,Supplying Laying Distribution system from 32 LL GLSR at plant BI01010001010000000000000515BI0100001112
2 1.001 Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar BI01010001010000000000000515BI0100001113 18.145 cum
3 1.002 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. BI01010001010000000000000515BI0100001114 12 cum
4 1.003 Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. BI01010001010000000000000515BI0100001115 14000 metre
5 1.004 Dismantling mannually/by mechanical means and disposal of material within 50meters lead as per direction of Engineer in charge- Bituminous road BI01010001010000000000000515BI0100001116 6000 10 sqm
6 1.005 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) BI01010001010000000000000515BI0100001117 64628.8 cum
7 1.006 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :"Ordinary Rock. (Ref. Item No. 2.13.1 of DSR) BI01010001010000000000000515BI0100001118 26831.6 cum
8 1.007 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m Hard Rock(Requiring Blasting). (Ref. Item No. 2.13.2 of DSR) BI01010001010000000000000515BI0100001119 275.688 cum
9 1.008 Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009) BI01010001010000000000000515BI0100001120 2404.95 metre
10 1.009 Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.NEW DATA (Prepared based on PWD SDB - Item No.1009 BI01010001010000000000000515BI0100001121 100 metre
11 1.01 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials :200 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.17 in DAR BI01010001010000000000000515BI0100001122 6250 metre
12 1.011 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 250 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.18 in DAR BI01010001010000000000000515BI0100001123 855 metre
13 1.012 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 300 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.19 in DAR BI01010001010000000000000515BI0100001124 2145 metre
14 1.013 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 400 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.21 in DAR BI01010001010000000000000515BI0100001125 325 metre
15 1.014 Conveying and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 excluding cost of pipes and specials : 450 mm dia Ductile Iron Class K-9 Pipes Data derived from 18.72.22 in DAR BI01010001010000000000000515BI0100001126 20 metre
16 1.015 Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329:K-9 conforming to IS: 8329 excluding cost of pipe and specials: 200 mm dia Ductile Iron Double Flanged"Data derived from 18.73.3 in DAR BI01010001010000000000000515BI0100001127 36 metre
17 1.016 Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329:K-9 conforming to IS: 8329 excluding cost of pipe and specials: 250 mm dia Ductile Iron Double Flanged"Data derived from 18.73.4 in DAR BI01010001010000000000000515BI0100001128 12 metre
18 1.017 "Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329:K-9 conforming to IS: 8329 excluding cost of pipe and specials:300 mm dia Ductile Iron Double Flanged"Data derived from 18.73.5 in DAR BI01010001010000000000000515BI0100001129 18 metre
19 1.018 Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329:K-9 conforming to IS: 8329 excluding cost of pipe and specials: 400 mm dia Ductile Iron Double Flanged"Data derived from 18.73.7 in DAR BI01010001010000000000000515BI0100001130 6 metre
20 1.019 Conveying and laying Double Flanged (Screwed / Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K-9 conforming to IS: 8329:K-9 conforming to IS: 8329 excluding cost of pipe and specials: 450 mm dia Ductile Iron Double Flanged"Data derived from 18.73.8 in DAR BI01010001010000000000000515BI0100001131 6 metre
21 1.02 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:200 mm dia pipes BI01010001010000000000000515BI0100001132 1137 joint
22 1.021 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:250 mm dia pipes BI01010001010000000000000515BI0100001133 156 joint
23 1.022 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:300 mm dia pipe BI01010001010000000000000515BI0100001134 390 joint
24 1.023 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:400 mm dia pipes BI01010001010000000000000515BI0100001135 60 joint
25 1.024 Providing push - on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket:450 mm dia pipes BI01010001010000000000000515BI0100001136 5 joint
26 1.025 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe BI01010001010000000000000515BI0100001137 10 Nos
27 1.026 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:250 mm diameter pipe BI01010001010000000000000515BI0100001138 6 Nos
28 1.027 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:300 mm diameter pipe BI01010001010000000000000515BI0100001139 8 Nos
29 1.028 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:400 mm diameter pipe BI01010001010000000000000515BI0100001140 15 Nos
30 1.029 Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:450 mm diameter pipe BI01010001010000000000000515BI0100001141 6 Nos
31 1.03 Cutting 200mm DI pipe BI01010001010000000000000515BI0100001142 35 No
32 1.031 Cutting 250mm DI pipe BI01010001010000000000000515BI0100001143 11 No
33 1.032 Cutting of 300mm dia. DI pipe with steel saw BI01010001010000000000000515BI0100001144 16 No
34 1.033 Cutting 400mm dia DI pipe with steel saw BI01010001010000000000000515BI0100001145 8 No
35 1.034 Cutting 450mm dia DI pipe with steel saw BI01010001010000000000000515BI0100001146 2 No
36 1.035 Fabricating MS pipes of size 200mm (ID) using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001147 24 metre
37 1.036 Fabricating MS flanges of diameter 200 mm using 12 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001148 12 Nos
38 1.037 Cutting 200 mm (ID) MS pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001149 4 No
39 1.038 Welding 200 mm (ID) MS pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001150 4 No
40 1.039 Grinding cut and weld edges of 200 mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001151 4 No
41 1.04 Fabricating MS pipes of size 250mm (ID) using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001152 18 metre
42 1.041 Fabricating MS flanges of diameter 250 mm using 12 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001153 10 Nos
43 1.042 Cutting 250 mm (ID) MS pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001154 4 No
44 1.043 Welding 250mm (ID) MS pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001155 10 No
45 1.044 Grinding cut and weld edges of 250 mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001156 10 No
46 1.045 Fabricating MS pipes of size 300mm (ID) using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001157 18 metre
47 1.046 Fabricating MS flanges of diameter 300 mm using 12 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001158 10 Nos
48 1.047 Cutting 300 mm (ID) MS pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001159 4 No
49 1.048 Welding 300 mm (ID) MS pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001160 10 No
50 1.049 Grinding cut and weld edges of 300 mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001161 10 No
51 1.05 Fabricating MS pipes of size 400mm (ID) using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001162 67 metre
52 1.051 Fabricating MS flanges of diameter 400 mm using 12 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001163 8 No
53 1.052 Cutting 400 mm (ID) MS pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001164 6 No
54 1.053 Welding 400 mm (ID) MS pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001165 14 No
55 1.054 Grinding cut and weld edges of 400 mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001166 14 No
56 1.055 Fabricating MS pipes of size 450mm (ID) using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001167 6 metre
57 1.056 Fabricating MS flanges of diameter 450 mm using 16 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001168 4 Nos
58 1.057 Cutting 450 mm (ID) MS pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001169 2 No
59 1.058 Welding 450mm (ID) MS pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001170 4 No
60 1.059 Grinding cut and weld edges of 450 mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. BI01010001010000000000000515BI0100001171 4 No
61 1.06 Testing 200mm DI/CI pipeline with potable water to the required test pressure 200 mm dia Observed Data derived from item no.1020 of PHED DATA BI01010001010000000000000515BI0100001172 6250 metre
62 1.061 Testing 250mm DI/CI pipeline with potable water to the required test pressure . 250 mm dia Observed Data derived from item no.1022 of PHED DATA BI01010001010000000000000515BI0100001173 855 metre
63 1.062 Testing 300mm DI/CI pipeline with potable water to the required test pressure. 300 mm dia Observed Data derived from item no.1023 of PHED DATA BI01010001010000000000000515BI0100001174 2145 metre
64 1.063 Testing 400mm DI/CI pipeline with potable water to the required test pressure.400 mm dia Observed Data derived from item no.1026 of PHED DATA BI01010001010000000000000515BI0100001175 325 metre
65 1.064 Testing 450mm DI/CI pipeline with potable water to the required test pressure. 450 mm dia Observed Data derived from item no.1027 of PHED DATA BI01010001010000000000000515BI0100001176 20 metre
66 1.065 Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes." BI01010001010000000000000515BI0100001177 140425 metre
67 1.066 Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).110 mm nominal outer dia pipes. BI01010001010000000000000515BI0100001178 5525 metre
68 1.067 Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 140 mm nominal outer dia pipes. BI01010001010000000000000515BI0100001179 8605 metre
69 1.068 Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).160 mm nominal outer dia pipes. BI01010001010000000000000515BI0100001180 4850 metre
70 1.069 Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 80 mm dia nominal bore Data derived from item no.18.12.8 of DARData for 10 m BI01010001010000000000000515BI0100001181 4213 metre
71 1.07 Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 100 mm dia nominal bore Observed Data derived from item no.18.12 of DAR BI01010001010000000000000515BI0100001182 166 metre
72 1.071 "Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 125 mm dia nominal bore Observed Data derived from item no.18.12 of DAR BI01010001010000000000000515BI0100001183 258 metre
73 1.072 Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 150 mm dia nominal ore Observed Data derived from item no.18.12 of DAR BI01010001010000000000000515BI0100001184 146 metre
74 1.073 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR BI01010001010000000000000515BI0100001185 75 Nos
75 1.074 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class I"Data derived from item no.18.31.1.1of DAR BI01010001010000000000000515BI0100001186 17 Nos
76 1.075 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :125 mm diameter. Class I"Data derived from item no.18.31.2.1 of DAR BI01010001010000000000000515BI0100001187 20 Nos
77 1.076 Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :150 mm diameter. Class I"Data derived from item no.18.31.3.1 of DAR BI01010001010000000000000515BI0100001188 17 Nos
78 1.077 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :200 mm diameter. Class I"Data derived from item no.18.31.4.1 of DAR BI01010001010000000000000515BI0100001189 11 Nos
79 1.078 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :250 mm diameter. Class I"Data derived from item no.18.31.5.1 of DAR BI01010001010000000000000515BI0100001190 4 Nos
80 1.079 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :300 mm diameter. Class I"Data derived from item no.18.31.6.1 of DAR BI01010001010000000000000515BI0100001191 4 Nos
81 1.08 "Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :400 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR BI01010001010000000000000515BI0100001192 1 Nos
82 1.081 Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 450 mm diameter. Class I"Observed Data derived from item no.18.31.of DAR BI01010001010000000000000515BI0100001193 1 Nos
83 1.082 Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 25 mm Single acting Air Valve Observed Data derived from item no.18.59.of DAR BI01010001010000000000000515BI0100001194 60 Nos
84 1.083 Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 40 mm Single acting Air Valve Observed Data derived from item no.18.59.of DAR BI01010001010000000000000515BI0100001195 20 Nos
85 1.084 Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 80 mm Double acting Air Valve Data derived from item no.18.59.2 of DAR BI01010001010000000000000515BI0100001196 12 Nos
86 1.085 Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately):100 mm Double acting Air Valve BI01010001010000000000000515BI0100001197 2 Nos
87 1.086 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil BI01010001010000000000000515BI0100001198 194.301 cum
88 1.087 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001199 9.241 cum
89 1.088 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001200 62.057 cum
90 1.089 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. BI01010001010000000000000515BI0100001201 509.372 sqm
91 1.09 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) BI01010001010000000000000515BI0100001202 97.287 cum
92 1.091 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more BI01010001010000000000000515BI0100001203 7883.17 kilogram
93 1.092 Supplying and fixing 500mm dia CI manhole cover with frame( medium duty) charges including all cost, labour charges etc complete. BI01010001010000000000000515BI0100001204 21 Nos
94 1.093 Providing and fixing Valve protection tube of 200 mm dia with Class-20 AC pipe, with RCC coverslab on top for 150mm dia controll valves and 40mm air valves. BI01010001010000000000000515BI0100001205 223 No
95 1.094 Providing and laying D.I specials of class K - 12 suitable for push - on jointing as per IS : 9523 : BI01010001010000000000000515BI0100001206 80.902 quintal
96 1.095 Supplying specials for GI pipes 5% BI01010001010000000000000515BI0100001207 216959 No
97 1.096 Supplying specials for pvc pipes 3% BI01010001010000000000000515BI0100001208 1.35022e+06 No
98 1.097 Supply ,stacking,spreading and consolidating of Quarry Muck in the trench of pipe line, including carriage, loading ,unloading & stacking up to any lead. BI01010001010000000000000515BI0100001209 186.272 cum
99 1.098 Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge. BI01010001010000000000000515BI0100001210 81.17 cum
100 1.099 Conveying surplus cut earth from site for removing obstruction to traffic and pedestrians at town areas where sufficient land is not available for stacking excavated earth within initial 5 km. ( code no. 1.1.2 ) including loading , unloading, stacking <br> BI01010001010000000000000515BI0100001211 217 cum
101 1.1 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. BI01010001010000000000000515BI0100001212 10000 kg
102 1.101 Repairing leakage/breakage of 80 mm AC pipe line by cutting and dismantling the damaged pipe portion (up to 1.5 m) including charges for earth work excavation in all kinds of soil including tar / concrete cutting for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new AC pipe to the required length, rejointing the pipeline using CID Joints , testing the pipe line by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers excluding the cost of pipe and CID Joints. BI01010001010000000000000515BI0100001213 12 Leak
103 1.102 Repairing leakage/breakage of 100 mm AC pipe line by cutting and dismantling the damaged pipe portion (Up to 1.5 m) including charges for earth work excavation in all kinds of soil including tar / concrete cutting for for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new AC pipe to the required length, rejointing the pipeline using CID Joints , testing the pipe line by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers excluding the cost of pipe and CID Joints. BI01010001010000000000000515BI0100001214 4 Leak
104 1.103 Repairing leakage/breakage of 125 mm AC pipe line by cutting and dismantling the damaged pipe portion (Up to 1.5 m) including charges for earth work excavation in all kinds of soil including tar / concrete cutting for for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new AC pipe to the required length, rejointing the pipeline using CID Joints , testing the pipe line by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers excluding the cost of pipe and CID Joints. BI01010001010000000000000515BI0100001215 3 Leak
105 1.104 Repairing leakage/breakage of 150 mm AC pipe line by cutting and dismantling the damaged pipe portion (Up to 1.5 m) including charges for earth work excavation in all kinds of soil including tar / concrete cutting for for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new AC pipe to the required length, rejointing the pipeline using CID Joints , testing the pipe line by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers excluding the cost of pipe and CID Joints. BI01010001010000000000000515BI0100001216 2 Leak
106 1.105 Repairing leakage/breakage of 200 mm AC pipe line by cutting and dismantling the damaged pipe portion (Up to 1.5 m) including charges for earth work excavation in all kinds of soil including tar / concrete cutting for for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new AC pipe to the required length, rejointing the pipeline using CID Joints , testing the pipe line by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers excluding the cost of pipe and CID Joints. BI01010001010000000000000515BI0100001217 2 Leak
107 1.106 Repairing leakage/breakage of 250 mm AC pipe line by cutting and dismantling the damaged pipe portion (Up to 1.5 m) including charges for earth work excavation in all kinds of soil including tar / concrete cutting for for exposing leak portion of the pipe, operating control valves if any, conveying to the site and cutting new AC pipe to the required length, rejointing the pipeline using CID Joints , testing the pipe line by operating the valves concerned, and rectifying the defects any noticed and without causing any damages to the existing utilities and refilling the trenches using excavated earth in layers not exceeding 20cm depth including consolidating each layers by ramming, watering, charges for removing surplus soil from work site, including hire for tools and plant, conveyance of tools and materials, bailing out water, providing caution boards, lighting, watching, ribbon fencing, traffic controlling etc.complete as per the direction of Departmental officers excluding the cost of pipe and CID Joints. BI01010001010000000000000515BI0100001218 2 Leak
108 1.107 Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. BI01010001010000000000000515BI0100001219 6398 Nos
109 1.108 Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. BI01010001010000000000000515BI0100001220 500 Nos
110 1.109 Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. BI01010001010000000000000515BI0100001221 1400 Nos
111 1.11 Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers. BI01010001010000000000000515BI0100001222 60960 metre
112 1.111 Providing 15mm (1/2 inch) GM Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers. BI01010001010000000000000515BI0100001223 25 Nos
113 1.112 Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. BI01010001010000000000000515BI0100001224 8298 Nos
114 1.113 Cost for Geo Tagging of Water connections BI01010001010000000000000515BI0100001227 8298 No
115 1.114 Shifting existing water service connection from existing line to newly laid pipe line using PE pipe with all accessories BI01010001010000000000000515BI0100001228 1471 No
116 1.115 Supplying and installing a electro-magnetic flow meter conforming to protection level of IP-68 for flow sensor and IP-67 for transmeter and having an accuracy level of 0.5% with LED/LCD display unit suitable to measure the discharge of transmission main of 450mm dia. The flow meter should have the housing (flow sensor) to be made of ss304/carbon steel with anti corrosive protection and inside liner to be made up of hard rubber/neoprene all confirming to drinking water standards. The flow meter should be coupled with HART for data acquisition and transfer with provision for wireless transfer through GSM. The manufacturers should have the calibration standards as per ISO 17025 and the product shall have sufficient warranty provisions. Product should be tested and calibrated at FCRI, Palakkad and test certificate should be produced. Flow meter should be calibrated with physical measurement at site after installation. Suitable for 450mm DI K-9 Pipe.A battery back up of min. 24 hrs should be provided. BI01010001010000000000000515BI0100001229 1 No
117 2 (C) - COST OF MATERIALS BI01010001010000000000000515BI0100001230
118 2.001 Supply of DI K9 Pipe Conforming to IS 8329/2000, 200mm Dia. BI01010001010000000000000515BI0100001231 6282 metre
119 2.002 Supply of DI K9 Pipe Conforming to IS 8329/2000, 250mm Dia. BI01010001010000000000000515BI0100001232 860 metre
120 2.003 Supply of DI K9 Pipe Conforming to IS 8329/2000, 300mm Dia. BI01010001010000000000000515BI0100001233 2164 metre
121 2.004 Supply of DI K9 Pipe Conforming to IS 8329/2000, 400mm Dia. BI01010001010000000000000515BI0100001234 327 metre
122 2.005 Supply of DI K9 Pipe Conforming to IS 8329/2000, 450mm Dia. BI01010001010000000000000515BI0100001235 21 metre
123 2.006 300mm D/F pipe BI01010001010000000000000515BI0100001236 18 metre
124 2.007 Supplying 450 MMDI k9 D/F pipe BI01010001010000000000000515BI0100001237 6 metre
125 2.008 250mm D/F pipe BI01010001010000000000000515BI0100001238 12 metre
126 2.009 Supplying 200mm DI Flanged pipe BI01010001010000000000000515BI0100001239 36 metre
127 2.01 400mm D/F pipe BI01010001010000000000000515BI0100001240 76 metre
128 2.011 Supply of PVC Pipe, 10kg/cm2, 160mm Dia. BI01010001010000000000000515BI0100001241 4875 metre
129 2.012 Supply of pvc pipe, 12.5kg/cm2, 140mm Dia. BI01010001010000000000000515BI0100001242 2086 metre
130 2.013 Supply PVC Pipe, 10kg/cm2, 140mm Dia. BI01010001010000000000000515BI0100001243 5935 metre
131 2.014 Supply of PVC Pipe, 8kg/cm2, 140mm Dia. BI01010001010000000000000515BI0100001244 392 metre
132 2.015 Supply of PVC Pipe, 6kg/cm2, 140mm Dia. BI01010001010000000000000515BI0100001245 237 metre
133 2.016 Supply of PVC pipe, 12.5kg/cm2, 110mm Dia. BI01010001010000000000000515BI0100001246 1131 metre
134 2.017 Supply of PVC Pipe, 10kg/cm2, 110mm Dia. BI01010001010000000000000515BI0100001247 3201 metre
135 2.018 Supply of PVC Pipe, 8kg/cm2, 110mm Dia. BI01010001010000000000000515BI0100001248 1222 metre
136 2.019 Supply of 90mm PVC, 12.5Kg/cm2 BI01010001010000000000000515BI0100001249 22422 metre
137 2.02 Supply of PVC Pipe, 10kg/cm2, 90mm Dia. BI01010001010000000000000515BI0100001250 75928 metre
138 2.021 Supply of PVC Pipe, 8kg/cm2, 90mm Dia. BI01010001010000000000000515BI0100001251 42568 metre
139 2.022 Supply of PVC Pipe, 6kg/cm2, 90mm Dia. BI01010001010000000000000515BI0100001252 212 metre
140 2.023 Supply of GI pipe as per DLPC rate 125mm GI BI01010001010000000000000515BI0100001253 258 metre
141 2.024 Supply of GI pipe as per DLPC rate 150mm GI BI01010001010000000000000515BI0100001254 146 metre
142 2.025 Supply of GI pipe as per DLPC rate 100mm GI BI01010001010000000000000515BI0100001255 166 metre
143 2.026 Supply of GI pipe as per DLPC rate 80mm GI BI01010001010000000000000515BI0100001256 4213 metre
144 2.027 Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm. BI01010001010000000000000515BI0100001257 60 No
145 2.028 Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 40mm BI01010001010000000000000515BI0100001258 20 No
146 2.029 Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 80mm. BI01010001010000000000000515BI0100001259 12 No
147 2.03 Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS1, Size 100mm. BI01010001010000000000000515BI0100001260 2 No
148 2.031 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 80mm. BI01010001010000000000000515BI0100001261 75 No
149 2.032 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm. BI01010001010000000000000515BI0100001262 17 No
150 2.033 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 125mm. BI01010001010000000000000515BI0100001263 20 No
151 2.034 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 150mm. BI01010001010000000000000515BI0100001264 17 No
152 2.035 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 200mm. BI01010001010000000000000515BI0100001265 11 No
153 2.036 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 250mm. BI01010001010000000000000515BI0100001266 4 No
154 2.037 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 300mm. BI01010001010000000000000515BI0100001267 4 No
155 2.038 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 400mm. BI01010001010000000000000515BI0100001268 1 No
156 2.039 Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 450mm. BI01010001010000000000000515BI0100001269 1 No
157 3 ROAD RESTORATION CHARGES FOR PANCHAYATH ROADS BI01010001010000000000000515BI0100001274
158 3.001 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete BI01010001010000000000000515BI0100001275 2500 cum
159 3.002 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBRValue-25 BI01010001010000000000000515BI0100001276 600 cum
160 3.003 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately):With Refinery Modified Bitumen CRMB 55 conforming to IRC:SP:53 - 1999 BI01010001010000000000000515BI0100001277 3000 sqm
161 3.004 4 cm thick bitumastic sheet with hot bitumen of approved quality using stone chippings (60% with 12.5 mm nominal size and 40% with 10 mm nominal size) @ 2.60 cum per 100 sqm and coarse sand @ 2.60 cum per 100 sqm of road surface and with bitumen @ 56 kg/ cum of stone chippings and @ 128 kg /cum of sand over a tack coat with hot straight run bitumen , including consolidation with road roller of 8 to 10 tonne etc. complete. (tack coat to be paid separately):With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt BI01010001010000000000000515BI0100001278 3000 sqm
162 4 Railway track crossing works BI01010001010000000000000515BI0100001279
163 4.001 Horizontal drilling 400mm dia MS Pipe (Pushing & Pulling method) BI01010001010000000000000515BI0100001280 18 metre
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2021 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail