Supply Of Spad (Chlorophyll Analysis
Tender Overview
Project Description
Supply Of Spad ( Chlorophyll Analysis - Handheld Meter For Measuring Chlorophyll Nmeasurement Sample: Plant Leaves Nmeasurement Area: 2Mm × 3Mm Nmedium Sample Thickness: 1.2 Mm Ninsertion Depth: 12 Mm Maximum; Depth Stop Adjustable To Depths Between O And 6 Mm Nlight Sources: 2 Leds ( Light-Emitting Diodes ) Nreceptor: 1 Spd ( Silicon Photodiode ) Ndisplay: Lcd Panel Showing 4 Digit Measurement Value ( -9.9 To 199.9 ) And 2 Digit Data Number Ndata Memory: Space For 30 Data Ncontrols: Power Switch: Switches Power On And Off N Average Key: Calculates The Average Of All Data In Memory N All Data Clear Key: Deletes All Data In Memory N Data Recall Key: Recalls Data Graphically For Previous Data Number N 1 Data Delete Key: Deletes Displayed Data N Measurements Automatically Taken When Measuring Head Is Closed Npower Source: 2 Aa-Size 1.5V Alkaline-Manganese Nbattery Life: More Than 20, 000 Measurements Per Set Of 2 Alkaline-Manganese Batteries Nminimum Interval Between Measurements: Less Than 2 Seconds Naccuracy: Within ± 1 Spad Unit ( At Room Temperature, Spad Value Between 0 And 50.0 ) ; Spad Valuesof Greater Than 50.0 May Be Less Accurate And Will Cause * To Appear Nrepeatability: Within ± 0.3 Spad Units ( Spad Value Between 0 And 50.0 ) Nreproducibility: Within ± 0.5 Spad Units ( Spad Value Between 0 And 50.0 ) Ntemperature Drift: Less Than 0.4 Spad Units 0C Noperating Condition: 0 To 500C ( 32 To 1220F ) Relative Humidity Less Than 85% At 350C With No Condensation Nother: Buzzer ( Single Beep For Measurement Complete, Series Of Beeps For Error ) ; Function For Inputtingcompensation Value Ndimension ( L × W × D ) : 164 × 78 × 49 Mm Nweight: 200G ( Without Batteries ) Nstandard Accessories: Sliding Depth Slope; Carrying Strap; Soft Case; 2 Aa-Size Batteries N Reading Checker N*Spad Values Are Values Defined By Konica Minolta Which Indicate The Relative Amount Of Chlorophyll Present In Plant Leaves. Specification Subject To Change Without Notice N Bi01010001010000000000000515bi0100001113 1 Nos
BOQ
| Name of Work: Supply of SPAD (Chlorophyll Analysis) | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | SPAD (Chlorophyll Analysis) | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.01 | Technical Specifications\n\nType: Handheld meter for measuring chlorophyll\nMeasurement sample: Plant leaves\nMeasurement area: 2mm × 3mm\nMedium sample thickness: 1.2 mm\nInsertion depth: 12 mm maximum; depth stop adjustable to depths between o and 6 mm\nLight sources: 2 LEDs (Light-emitting diodes)\nReceptor: 1 SPD (Silicon photodiode)\nDisplay: LCD panel showing 4 digit measurement value (-9.9 to 199.9) and 2 digit data number\nData memory: Space for 30 data\nControls: Power switch: Switches power on and off\n Average key: calculates the average of all data in memory\n All data clear key: deletes all data in memory\n Data recall key: recalls data graphically for previous data number\n 1 data delete key: deletes displayed data\n Measurements automatically taken when measuring head is closed\nPower source: 2 AA-size 1.5v alkaline-manganese\nBattery life: more than 20,000 measurements per set of 2 alkaline-manganese batteries\nMinimum interval between measurements: less than 2 seconds\nAccuracy: within ± 1 SPAD unit (at room temperature, SPAD value between 0 and 50.0); SPAD valuesof greater than 50.0 may be less accurate and will cause * to appear\nRepeatability: within ± 0.3 SPAD units (SPAD value between 0 and 50.0)\nReproducibility: within ± 0.5 SPAD units (SPAD value between 0 and 50.0)\nTemperature drift: less than 0.4 SPAD units 0C\nOperating condition: 0 to 500C (32 to 1220F) relative humidity less than 85% at 350C with no condensation\nOther: buzzer (Single beep for measurement complete, series of beeps for error); function for Inputtingcompensation value\nDimension (L × W × D): 164 × 78 × 49 MM\nWeight: 200g (without batteries)\nStandard accessories: sliding depth slope; carrying strap; soft case; 2 AA-size batteries \n Reading checker\n*SPAD values are values defined by Konica Minolta which indicate the relative amount of chlorophyll present in plant leaves. Specification subject to change without notice\n | BI01010001010000000000000515BI0100001113 | 1 | Nos |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender