Agriculture Government Departments Closing in 0 days TDR #27146525

Construction Of Soil Testing Quality Control And Input Testing ( Stqc And It ) Laboratory At Diphu Construction Of Soil Testing Quality Control And Input Testing ( Stqc And It ) Laboratory At DiphuDist K-Anglong

Issued by Government Departments · Diphu Karbi Anglong, Assam
Tender Value
1.48 Crore
Estimated cost
Bid Submission
20 Apr 2021
0 days left
EMD
2.97 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Diphu Karbi Anglong → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Soil Testing Quality Control And Input Testing ( Stqc And It ) Laboratory At Diphu

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Mar-2021 Corrigendum Date 20-Apr-2021

BOQ

Name of Work: Construction of Soil Testing Laboratory at Diphu under Karbi Anglong District of Assam
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Civil Work (Main Building)item 1
22Earth work in excavation for foundation trenches of walls, retaining walls, Footing of Columns, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\nUp to a depth of 2.00m. below the existing G.L.\nOrdinary Soilitem 2
33Main Building-Totalitem 3316.77Cum
44Extra over item above for each 1m depth or part thereof beyond the initial depth of 2mitem 4
55Totalitem 571.05Cum
66Earth / Sand filling with river sand or silt (predominantly non plastic) by truck carriage including loading and unloading in plinth in layer not more than 150 mm thick including necessary, carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes as may be necessary.Main Building Plinth,Deduction in front area,Left side Near Corridor areaitem 6
77Totalitem 755.55Cum
88NOMINAL MIX. ( P.C.C. WORKS )item 8
99Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1 cement : 3 sand : 6 coarse aggregate by volumeitem 9
1010Main Building-Totalitem 1034.21Cum
1111Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5: 3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.item 11
1212Ground Floor-Totalitem 12225sqm
1313REINFORECED CEMENT CONCRETE WORKSitem 13
1414Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). Using Mixer Machine.In substructure upto plinth level.Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick.M20 grade concrete or prop. 1:1.5:3item 14
1515(Main building)Totalitem 1558.21cum
1616In super structure. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing.M20 grade concrete or prop. 1:1.5:3item 16
1717Main buildingitem 17212.93cum
1818PLYBOARD SHUTTERINGitem 18
1919Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in::Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.Using 25mm thick plankitem 19
2020Main buildingitem 20151.28sqm
2121Sides of tie beams, grade beams etc. at or below ground level.item 21129.54sqm
2222Columns, Pillars, Posts & Strutitem 22267.32sqm
2323Sides and soffits of beam, beam haunchings, cantilever girders, bressumers, lintel and horizontal ties.Tie beam, beams, lintels.item 23
2424Total (Main building)item 24650.16sqm
2525Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slab, chajjas, balcony and the like Floors etc. upto 200 mm in thicknessSides and soffits of beam, beam haunchings, cantilever girders, bressumers, lintel and horizontal ties.Tie beam, beams, lintels.item 25
2626Main Building-Totalitem 26794.03sqm
2727Staircase with sloping or stepped soffits including risers and stringers but excluding landing .item 27
2828Main buildingitem 2855.28sqm
2929BRICK WORKitem 29
3030Providing brick flat soling in foundation and under floor with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete.Brick on flat soling.item 30
3131Total (Main building)item 31342.14sqm
3232Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\nIn Sub-structure upto plinth level including dewatering if necessary.In proportion 1:4.item 32
3333Main Building-Totalitem 3311.17Cum
34341st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately).\n115 mm thick brick wall. In cement mortar in proportion 1:4.(1 cement:4 sand).item 34
3535Main Building-Totalitem 35767.93sqm
3636FLOORINGitem 36
3737Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. (b) 50mm thickitem 37
3838Main Building-Totalitem 38224.63sqm
3939Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. b) 15mm thickitem 39
4040Main Building-Totalitem 40797.74sqm
414165 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.item 41
4242Ground Floor -Totalitem 42185.17sqm
4343Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)item 43
4444Executive range-Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make\nOf size 800mmx800mm and aboveitem 44
4545Totalitem 45548.13sqm
4646Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.CERAMIC.Normal range (Sizes 300 mm x 300mm and above).Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slateitem 46
4747Main Building -Totalitem 47126.81sqm
4848Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).item 48
4949Normal Quality.With White cementitem 4919.2sqm
5050Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).item 50
5151i) Of size 300mmx450mm and aboveitem 51
5252Main Building-Totalitem 52142.51sqm
5353Providing polished SUNROCK-Hi CTS/ MULTIWYN tiles of approved quality, size, shape and thickness not less than 18mm on floors and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department).item 53
5454(a) SUNROCKHi CTS TILESitem 54
5555i). Well, Chocolate, Diamond Square, Ramp, Beach Sand (300x300) mmitem 55155.1sqm
5656CEMENT PLASTERINGitem 56
575715 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.item 57
5858On rough side. In cement mortar 1:4. Ground Flooritem 58
5959building-Totalitem 59767.91sqm
6060On fair side. In cement mortar 1:4.item 60
6161building-Totalitem 61799.11sqm
626210 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.item 62
6363b) In cement mortar 1:3item 6363.44sqm
6464Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.item 64
6565Main Building-Totalitem 651630.45sqm
6666WOOD WORKSitem 66
6767Providing wood work in frame (chowkaths) of doors, windows, clerestory windowsitem 67
6868(b) With Ist Class timber ( Bonsum/Sundi)item 680.29Cum
6969Providing, fitting and fixing factory made exterior type fully panelled single leaf door shutters of approved brand conforming to relevent I.S code having kiln seasoned and vacuum pressure treated Hollock / Bonsum / Sundi rail and styles with pannel of Anchor brand 12mm thick veneered Teak wood particle board bonded with phenol - formaldehyde synthetic resin adhesive conforming to relevent I.S code including 4 nos of oxidised iron butt hinges (100mm x75 mm x3.55mm) to each leaf complete.item 69
7070(i) 40mm thickitem 7036.12sqm
7171GRILLSitem 71
7272Supplying, fitting and fixing anodised aluminium decorated grill with anodised aluminium rectangular frame of 'F' and 'H' section fitted with walls, columns or stiffeners by special type of screws as per specification by the Department for all levels. (Aluminium Alloy procured from primary aluminium producer (On submission of certificate of alloy purchaging from primary producer)item 72
7373Ground Floor,first floor-Totalitem 7362.28sqm
7474ALUMINIUM WINDOWSitem 74
7575Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.item 75
76762 track sliding windows.5 mm clear glassitem 76
7777main building -Totalitem 779.72sqm
78785 mm frosted glassitem 78
7979Ground Floor,first floor-Totalitem 7912.6sqm
80803 track sliding windows.6mm clear glassitem 80
8181Ground Floor,first floor-Totalitem 8139.96sqm
8282ALUMINIUM PARTITIONitem 82
8383Providing, fitting and fixing anodised aluminium partition walls of standard sections of approved brand, joints mitred and welded (manufactured to relevant I.S. specification) and providing and fitting angle cleat, rubber gasket, bolting device screws etc. at all levels.item 83
8484Prelaminated Boarditem 84
8585Ground Floor,first floor-Totalitem 8553.69sqm
8686Providing, fitting and fixing anodised aluminium framed glazed doors with partition walls partly glass and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections of approved brand with doors style of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81mm x 43mm x 2mm, fitting with glazing clip, special rubber type gusket complete including hydraulic floor spring pivot aluminium door handle lock angles cleat etc. complete as directed by the department at all levels.item 86
87876mm thick glass panes and 12mm prelaminated board.Ground Floor,first floor-Totalitem 8763sqm
8888P.V.C. DOORS & DOOR FRAMESitem 88
8989Providing, fitting and fixing 40 mm x 48 mm wood reinforced PVC chowkhats fixed to the columns / stiffeners / walls with necessary holdfast / sleeves etc. as specified and directed at all levels.item 89
9090Ground Floor,first floor-Totalitem 9069.3Rm
9191Providing, fitting and fixing 24 mm / 29 mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately).item 91
929229 mm thick. Ground Floor,first floor-Totalitem 9222.05sqm
9393PAINTINGitem 93
9494Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)item 94
9595Thickness = 1.5 mm thickitem 951598.26sqm
9696Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.item 961598.26sqm
9797Applying priming coat with ready mixed paint, wood primer (pink) over new wood based surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting.item 97
9898With ready mixed paint, wood primer (pink)item 9858.39sqm
9999Painting two coats surfaces over 100mm in width or grith (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping.item 99
100100Surface over 100mm in width or girth. High gloss (Asian paint/ Berger paint/ ICI paint/ J& N paint/ Nerolac)item 10058.39sqm
101101Applying primary coat with ready mixed \"red -lead /red-oxide\" primer over new steel and other metal surface up to 100mm in width or girth after preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.item 101
102102With ready mixed 'red-lead/ red oxide' primeritem 10262.28sqm
103103Painting two coats Surfaces over 100mm in width or grith (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter. .item 103
104104Surface over 100mm in width or girth.High gloss (Asian paint/ Berger paint/ ICI paint/ J& N paint/ Nerolacitem 10462.28sqm
105105Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/ F suspended ceiling which includes G.I. perimeter channels of size 0.55mm thick…etc.item 105280.9sqm
106106DOOR FITTINGSitem 106
107107Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )item 107
108108\nSliding door bolts.250mm x16mm sliding door bolt.item 10810each
109109Tower boltitem 109
110110300mm x 12mm tower bolt.item 11068each
111111M) Motor lock Vertical Typitem 111
112112V) ii) 75mm (Godrej with handle(4 Lever)item 11218each
113113REINFORCEMENTitem 113
114114Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \nFrom Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL.Super Ductile (SD) TMT reinforcement bars\nitem 114260.36qtl
115115DOOR FRAMESitem 115
116116Providing and fixing stainless steel (Grade-304) railing made of Hollow tubes,channels,plates etc. including welding,grinding,buffing,polishing and making curvature(wherever required) and fitting the same with necessary stainless steel bolts and nuts complete i.e fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size,on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer- in- charge (For payment,only weight of stainless steel member is to be considered .No extra payment for fixing accessories such as nuts,bolts,fasteners etc. will be considered)item 116198.84kg
117117Providing and fixing in position collapsible M.S. shutters with vertical channels 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size with top and bottom rails of T-iron 40mmx40mmx6mm with 38mm dia steel pulleys complete with bolts and nuts, locking arrangements, stoppers, handles including applying a priming coat of red lead paint.item 1175.88sqm
118118PLINTH PROTECTION WORKS AND PERIPHERY DRAINSitem 118
119119Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.item 11929sqm
120120Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.\n300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.item 12070Rm
121121ANTI TERMITE TREATMENTitem 121
122122Pre construction anti-termite treatment at the bottom of foundation pits and walls on either side up to a height of 300 mm from the the bottom of the excavation made for column, plinth beam, wall trenches etc by applying the emulsion @ 5 litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\nWith aqueous emulsion having concentration 1:19 with chloropirophose solution and water i.e. 1% solution.\nTotalitem 122270.5sqm
123123FIRE EXTINGUISHERitem 123
124124Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) \nBRAND : FIRESTOP / FIREND / FIRE SHIELDitem 12410each
125125Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark\n(05 kg capacity) \nBRAND : FIRESTOP / FIREND / FIRE SHIELDitem 12510each
126126BIO-DIGESTER(Septic tank)item 126
127127Earth work in excavation for foundation trenches of walls, retaining walls, Footing of Columns, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\nUp to a depth of 2.00m. below the existing G.L.\nOrdinary Soilitem 12720.16cum
128128NOMINAL MIX. ( P.C.C. WORKS )item 128
129129Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately).In prop. 1 cement : 3 sand : 6 coarse aggregate by volumeitem 1290.49cum
130130Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). Using Mixer Machine.In substructure upto plinth level.Foundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick.M20 grade concrete or prop. 1:1.5:3item 1301.48m3
131131In Super structure from plinth level upto Ist Floor Level. Vertical Wall, In Prop : M20 Grade of concrete 1: 1.5:3item 1314.88m3
132132ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nN) Without using admixture, plasticiser\nb) M20 grade concrete or Prop. 1:1.5:3item 1321m3
133133PLYBOARD SHUTTERINGitem 133
134134Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in::Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.Using 25mm thick plank\nColumns, Pillars, Posts & Strutitem 1341.98sqm
135135Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slab, chajjas, balcony and the like Floors etc. upto 200 mm in thicknessitem 1358sqm
136136Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.item 13643.2sqm
137137Providing brick flat soling in foundation and under floor with stone / best quality picked jhama bricks, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials, and if necessary dewatering, complete.Brick on flat soling.item 1379.89sqm
13813865 mm thick cement concrete floor consisting of 50 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 25mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for bond @ 2.75 kg. per square metre of floor area) including curing etc. complete as directed.item 1388sqm
139139CEMENT PLASTERINGitem 139
14014010 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\nb) In cement mortar 1:4item 14052sqm
141141Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(ii)Super Ductile (SD) TMT reinforcement barsitem 1419.04qtl
142142NON SHEDULE ITEMitem 142
143143Alumunium Roditem 14360nos
144144Aluminium hangeritem 144360nos
145145Nylon matricesitem 1451800Nos
146146Alumunium binderitem 1461800Nos
147147Bacteriaitem 1471600litres
148148PVC Pipe fittingsitem 1481job
149149Sanitary and Water Supply Worksitem 149
150150EUROPEAN TYPE WATER CLOSETitem 150
151151Providing fitting and fixing vitreous China pedestal type water closet (European type WC pan 400 mm high) with seat and lead, CP brass hinges and rubber buffers, CI / MS brackets, 40 mm diameter flush band withfittings including painting of fittings and brackets, required. \nParryware make.White\n(i) Universal Closet S trapitem 15110each
152152PVC FLUSHING CISTERNitem 152
153153Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc.\nParyware make.White. Economy single flushitem 15310each
154154URINALitem 154
155155Providing fitting and fixing vitreous China flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required.\nc) Jaquar make.White. Urinal (Cat.No.URS-WHIT-0704) With Sensor (Cat No. SNR-CHR51097)item 15510each
156156Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. \n(ii) Hindware Make\n(a) White\n(i) Division Plate 680 x 300 (Cat. No.61001)item 15610each
157157WASH BASINitem 157
158158Providing vitreous China wash basin with CI / MS brackets, CP brass chain with plug, PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately).\nBASIN (without pedestal), Parryware Make.\nTapti Basin 500 x 360 (Cat No.C0424/410).item 15810each
159159MIRRORitem 159
160160Providing fitting and fixing Mirror with plastic frame of size 500 x 400mm complete as directed and specified.\nitem 16010each
161161SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINERitem 161
162162Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified.\n(i) Jaquar Make\n(a) Continental (Cat.No.ACN-1331N)item 16210each
163163TOWEL RAIL,TOWEL RACK & TOWEL RINGitem 163
164164Providing, fitting and fixing CP towel rail complete as directed and specified.\nJaquar make (i) continental towel ring square cat no.ACN-1121\nitem 16410each
165165WASTE COUPLINGitem 165
166166Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified.\nb) sona(i) Rupa 32mm (HT/FT)(Cat No.WS-0801)item 16610each
167167Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified.\n(a) Sona make \n(i) Pipe for bottle trap 300mm long (Cat. No.BT-0761)item 16710each
168168PVC PIPES, BENDS, JUNCTIONS, TEES ETC.item 168
169169Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.item 16936Rm
170170Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches. \n(ii) 100mm diaitem 17010each
171171Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm diaitem 17110each
172172Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.\n(ii) 110mm dia. PVC cowel of ISI makeitem 17210each
173173Supplying, fitting and fixing Chrome Plated (C.P.) basin mixer complete as directed. \nLauret Make a) Central hole basin mixer Cat No. 1210 for wash basinitem 17310each
174174GRATINGitem 174
175175C.P. Grating. 110 mm diaitem 17510each
176176Construction of inspection pit inside measurement 450mm x450mm x450mm .. Etc excavation of pit as directed.item 1761each
177177Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. \nHigh Speed 225 mm sweep (ORIENT make), Trans Air 225 mm sweep (Crompton make), Ventil Air DX 250 mm sweep Louver type (Havells make)item 17710each
178178Renewing laboratory sink of Parryware make with PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately.\n(b) coloured\n(ii) Size 450 x 300 x 180 (Cat.No.50001)item 1784each
179179Pipingitem 179
180180Providing & fixing CPVC Pipes having thermal stability for hot and cold water supply:-item 180
181181(A)) Exposed or in trenchesitem 181
182182a) 15 mm nominal outer dia pipeitem 18220Rm
183183d) 32 mm nominal outer dia pipeitem 18318Rm
184184e) 40 mm nominal outer dia pipeitem 18412Rm
185185(B) Concealed pipe with cutting chases & making good the wallsitem 185
186186a) 15 mm nominal outer dia pipeitem 18615Rm
187187b) 20 mm nominal outer dia pipeitem 18715Rm
188188BIB COCKitem 188
189189Supplying fitting and fixing CP bib cock 15 mm diametre of approved brand directed and specified. (GI and CP pipes will be measured separately).Jaquare make.Continental /Clarion\nAgmeco brand\n(v) Bib Cock Two way with Flange CAT No.CC 00203/CAT No.CN 00203item 1897each
190190STOP COCKitem 190
191191Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified.item 191
192192Agmeco Branditem 192
193193(a) 15mm dia(Male/ Female )item 1932each
194194(b)15mm dia(Concealed )item 1944each
195195Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. \nAgmeco (classic) \n(b) Rounditem 1958each
196196Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.item 196
197197a) 50mm diaitem 1971each
198198c) 25 mm dia.item 1981each
199199Supplying fitting and fixing G.I. Pipes of following sizes, with all necessary 'R' brand or similar approved G.I. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, H.W. clamps etc.complete at all levels including below G.L. as directed and specified.item 199
200200(A) Exposed on walls\nb) 40 mm dia (Medium)\ni) Using Tata makeitem 20012Rm
201201f) 15 mm dia (Medium)\ni) Using Tata makeitem 20130Rm
202202(II) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.\nf) 15 mm dia (Medium)\ni) Using Tata makeitem 20224Rm
203203Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipe\n2000 Lt capacity\n(a) Sintex makeitem 2032each
204204Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fittings such as valve,bib cock,pipe connection etc.with a free maintanance period of six monthhs\n(A) With Zoloto fittings \n(III) 5000 liters capacity\n(a) 6 mm thick Vessel FRPitem 2041each
205205INTERNAL ELECTRICAL WORKS MAIN LABORATORY BUILDINGitem 205
206206SCHEDULE ITEMSitem 206
207207Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . \n3 core A2XWY A2XFY \n 10.00 Sq.mm 3 Core armoured U.G. cableitem 20710Rm
208208Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical indoor type floor/wall mounting compartmentalize panel board of size 1.25M X0.7MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 250A 4pole 415V MCCB or Switch Fuse Unit as incomer and provision for 2nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items:item 2082each
209209Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.item 209
210210Short point up to 3.00 metre. length.item 21055each
211211Wiring for Circuit Wiring with 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item 211180meter
212212Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.item 212
213213With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item 213240meter
214214With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. \nitem 214140meter
215215With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.item 215100meter
216216Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required.item 21640meter
217217Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .item 2172each
218218Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.item 21824meter
219219Wiring for light point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor … etc as directed.item 219
220220Short point up to 3.00 metre. length.item 22050each
221221Medium point up to 6.00 metre. Length.item 22115each
222222Long point up to 10.00 metre. Length.item 22220each
223223Wiring for Fan point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor … etc as directed. \nMedium point up to 6.00 metre. Length.item 22325each
224224Wiring for Call Bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor … etc as directed. \nLong point up to 10.00 metre. Length.item 2244each
225225Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\nMedium point up to 6.00 metre. Length.item 22550each
226226Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lampitem 22615each
227227Supplying including fitting and fixing of electronic resistance type regulator for ceiling fan complete with all connection etc.item 22725each
228228Supplying fixing I.C.T.P and N link Main Switch with rewire able fuses of 500 Volt grade( HPL/ GECO / ANCHOR or equivalent make) including drilling boards/iron frames and fixing with bolts and nuts and connection as approved by the Deptt.)complete as required 30/32 Amps Capacity T.P. Nitem 2282each
229229Providing and fixing IC distribution fuse board with re-wireable fuses of 250 Volts grade 15 Amps per way including fixing to the board and connection etc.\n3 - way capacityitem 2293each
230230Installation, testing and commissioning of pre-cabled fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling/wall including connection as approved by the Deptt.)with 1.5 sq mm PVC insulated copper cables as required.item 23020each
231231Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. \nSchneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 6 way SPN single dooritem 23110each
232232EXTERNAL ELECTRICAL WORKS MAIN LABORATORY BUILDINGitem 232
233233Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.item 23340each
234234Transformeritem 234
235235Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. \n63 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.item 2351each
236236Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.item 2362each
237237Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f.(la mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KVitem 237
238238TECHNICAL DATA CJ25D5P\nGENERATOR SET SPECIFICATIONS 25/20\n3. No. of Phases. 1 phase.\n4. POWER FACTOR 0.8 LAG\nJACKSON ENGINE SPECIFICATION. \n1. make). Cummins\n2. Model. X 2.5 G2\n3. No. of Cylinders. 3\n4. Aspiration. Natural\n5. Cooling. Water Cooled.\n6. Governor. Mechanical\n7. Battery Capacity Rating. 12 Volt.\n8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 4.8\nALTERNATOR SPECIFICATION. \n1. make). CGT (STAMFOR \n2. Voltage Regulation. +/- 1.0%\n3. Insulation. Class - H.\n4. Standard Enclosure. IP 23\n5. No. of Phases. 3 AND 1item 238
239239WITH SRANDARD CONTROL PANELitem 2391each
240240MAIN ENTRANCE GATEitem 240
241241EARTH WORK\nEarthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.\nitem 2415.76each
242242NOMINAL MIX. ( P.C.C. WORKS )item 242
243243Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footings, tie beams, steps, walls, brick works etc. as directed and specified including dewatering if necessary and curing complete (shuttering where necessary shall be measured and paid separately). \nIn prop. 1 cement : 3 sand : 6 coarse aggregate by volumeitem 2430.34cum
244244REINFORECED CEMENT CONCRETE WORKSitem 244
245245Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). \nIn substructure upto plinth level\nFoundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:1.5:3item 2451.44cum
246246In super structure\nColumns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:1.5:3item 2460.39cum
247247PLY BOARD FORMWORKitem 247
248248In super structure\nColumns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:1.5:3item 2480.39cum
249249Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:item 249
250250Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick Plank.item 2506.48sqm
251251Sides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plankitem 2513.78sqm
252252Columns, pillars, posts, & struts of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face.item 25213.92sqm
253253Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\nb) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)\n (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .item 2532.34sqm
254254Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nII Ornamental grill (c) Fixed to Brickwork/P.C.C/R.C.C.item 254330.75kg
255255PLASTERINGitem 255
25625620 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nB) On fair side a) In cement mortar 1:3item 2564.14sqm
257257PAINTINGitem 257
258258Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.item 2584.14sqm
259259Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)item 2594.14sqm
260260Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer.item 26015.54sqm
261261Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).item 26115.54Nos
262262PARKING ENTRANCE GATEitem 262
263263Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.\nitem 2632.16sqm
264264Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling.item 2642.34sqm
265265Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volumeitem 2650.23sqm
266266Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reiforcement baritem 2661.11qtls
267267FORM WORKitem 267
268268Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc. b) Using 25mm thick Plank.item 2680.96sqm
269269Sides of tie beams, grade beams etc. at or below ground level.\n(a) Using 38mm thick plank\n(b) Using 25mm thick plankitem 2692.16sqm
270270Columns, Pillars, Posts & Strut\n(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face\n(ii) Using 25mm thick plankitem 2702.1sqm
271271REINFORECED CEMENT CONCRETE WORKSitem 271
272272Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). \nIn substructure upto plinth level\nFoundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:1.5:3item 27214.4cum
273273In super structure\nColumns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:1.5:3item 2730.13cum
274274Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).item 2742.92qtls
275275WASTE DISPOSAL AREAitem 275
276276Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.\nitem 27617.15cum
277277Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling.item 2779.96sqm
278278Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volumeitem 2781sqm
279279Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reiforcement baritem 2792.06qtls
280280CEMENT PLASTERINGitem 280
281281Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:item 281
282282Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. b) Using 25mm thick Plank.item 28214.52sqm
283283Sides of tie beams, grade beams etc. at or below ground level.item 283
284284(b) Using 25mm thick plankitem 2847.2sqm
285285Columns, Pillars, Posts & Strutitem 285
286286(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical faceitem 286
287287(ii) Using 25mm thick plankitem 2877.2sqm
288288REINFORECED CEMENT CONCRETE WORKSitem 288
289289Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). \nIn substructure upto plinth level\nFoundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:1.5:3item 2892.93cum
290290In super structure\nColumns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:1.5:3item 2900.36cum
2912911st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand)item 29125.5cum
29229215 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nB) On fair side\nb) In cement mortar 1:4item 29225.5sqm
29329315 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\nb) In cement mortar 1:4item 29325.5sqm
294294Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.\n(a) 15 mm thickitem 29421.6sqm
295295DISMENTALLING OF ASSAM TYPE BUILDINGitem 295
296296Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.item 296316.8sqm
297297Dismantling all types of ceiling, partition and wall lining and stacking the materials as directed by the department for all levelsitem 297316.8sqm
298298Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levelsitem 298403.56sqm
299299Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levelsitem 29987.63Rm
300300Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levelsitem 30019.51Rm
301301Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. \n(i) Area of door/window up to 3.00 m2item 30194each
302302SURFACE DRAINitem 302
303303Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.\nitem 30320cum
304304Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling.item 30432sqm
305305Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volumeitem 3053.2sqm
306306Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(a) In proportion 1:3.item 30612.88each
30730740 mm thick cement concrete floor consisting of 25 mm under layer of cement concrete in prop. 1:3:6 (1cement : 3 coarse sand : 6 coarse aggregate of 12.5 mm and down) and 15 mm thick wearing layer in cement concrete in prop. 1:1:2 (1cement :1 coarse sand : 2 coarse aggregate of size 10mm down) finished with a floating coat of neat cement finish using cement slurry for bond @ 2.75 kg. per square metre of floor area , wearing layer is to be laid in panels including curing etc. complete as directed.item 30712each
308308Cement plaster skirting with cement mortar in prop. 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.\n(a) 15 mm thickitem 30850.4each
309309BOUNDARY WALLitem 309
310310Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.(a) In Ordinary Soil. Upto 2.00m Depth.\nitem 31022.41sqm
311311Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\n(a).Brick on flat soling.item 31125.1sqm
312312Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volumeitem 3122.51sqm
313313Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)item 313
314314a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINLitem 314
315315(i) TMT Corrosion resistant steel (CRS) reiforcement baritem 3155.96qtls
316316c) ISI approved Mild steel reinforcement bar(M.S.Bar)item 3161.75qtls
317317FORM WORKitem 317
318318Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc. b) Using 25mm thick Plank.item 31828.75sqm
319319Sides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plankitem 31925.92sqm
320320Columns, Pillars, Posts & Strut\n(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face\n(ii) Using 25mm thick plankitem 32027sqm
321321REINFORECED CEMENT CONCRETE WORKSitem 321
322322Providing and laying controlled cement concrete of grade M 20 with 20mm down graded stone aggregate including dewatering if necessary, and curing complete, excluding cost of form work and reinforcement for reinforced concrete work (form work and reinforcement will be measured and paid separately). \nIn substructure upto plinth level\nFoundation, footings, columns with base, tie and plinth beam, grade beam, pile cap, base slab, retaining wall, walls of septic tank, inspection pit and the like and other works not below 100mm thick. in prop: 1:2:4item 3226.21cum
323323In super structure\nColumns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase including preparing of top surfaces and furnishing and nosing. (b) in prop: 1:2:4item 3231.01cum
324324Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(b) In proportion 1:4.item 3244.19cum
3253251st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand)item 32571.01sqm
32632615 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\na) In cement mortar 1:3item 326187.92sqm
327327a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.item 327187.92sqm
328328b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.item 328187.92sqm
329329INSTALLATION OF AIR CONDITION SYSTEMitem 329
330330Supplying with installation testing and commissioning of Hi -- wall 4 STAR rating non ducted split type air conditioner of the following capacity with cordless remote complete with indoor and outdoor unit, copper pipe and electrical connection as approved by the Deptt.)up to 5 m between the room unit and out door unit as directed by the department.\n(Carrier make) Kurve/ Voltas make) Model PLATINUM 4Sitem 3304each
331331Electrical Service connection (LS)item 3311job

AI Tender Summary

OUR REF NO 27146525
AUTHORITY Government Departments
TENDER VALUE 1.48 Crore
LAST DATE 20-04-2021
Authority
Authority Name Assam Seeds CorporationLimited
Work Description Construction Of Soil Testing Quality Control And Input Testing ( Stqc And It ) Laboratory At Diphu
Basic Detail
Tender No Agr/Eg/4210/STRvn/Ph2/1920/132
Bidding Type Tender
Location
City Diphu Karbi Anglong
State Assam
Key Dates
Publish Date 09 Mar 2021
Submission Date 20 Apr 2021
Open Date 20 Apr 2021
Finance
Tender Value 1.48 Crore
Tender Fee 2000
EMD 2.97 Lakhs
Exemption Not Available
Document List
653FD163-DA01-4D4D-911F-F6363EC2A981.html
Tendernotice_1.pdf
BOQ_33428.xls
BiddingdocumentFinal.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 09, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Apr 20, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 20, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Apr 20, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

653FD163-DA01-4D4D-911F-F6363EC2A981.html

pdf

Tendernotice_1.pdf

xls

BOQ_33428.xls

pdf

BiddingdocumentFinal.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender