Design Engineering Procurement Installation Testing Commissioning Of 0 . 8 Mw Solar Plant Along With Associated Transmission System Substation With Two Year Comprehensive Dlp At Konia Mps Varanasi, Varanasi-Uttar Pradesh

Uttar Pradesh Jal Nigam-UPJN has published Design Engineering Procurement Installation Testing Commissioning Of 0 . 8 Mw Solar Plant Along With Associated Transmission System Substation With Two Year Comprehensive Dlp At Konia Mps Varanasi. Submission Date for this Tender is 20-03-2021. Solar Power Plants Tenders in Varanasi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27135124
Corrigendum : Design Engineering Procurement Installation Testing Commissioning Of 0 . 8 Mw Solar Plant Along With Associated Transmission System Substation With Two Year Comprehensive Dlp At Konia Mps Varanasi
Open Tender
Indian
Uttar Pradesh
Varanasi
20-03-2021

Tender Details

Design Engineering Procurement Installation Testing Commissioning Of 0 . 8 Mw Solar Plant Along With Associated Transmission System Substation With Two Year Comprehensive Dlp At Konia Mps Varanasi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Mar-2021 Date of Extension Date 16-03-2021
2 15-Mar-2021 Time Extension Date 18-03-2021
3 18-Mar-2021 TIME EXTENSION CORRIGENDUM Date 20-03-2021

Key Value

Document Fees
INR 11800 /-
EMD
INR 940000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Design, Engineering, Procurement, Installation, Testing & commissioning of 0.8 MW Solar Plant along with associated transmission system at 33 kV voltage level up to 33/0.415 kV substation with comprehensive DLP (Defect Liability Period) of 2 Year at 100 MLD MPS Konia, Varanasi
Sl. No. Item Description Item Code / Make Quantity Units
1 1.1 Solar PV System Supply, installation, testing and commissioning of Mono/Polycrystalline Photovoltaic Panel of 325Wp each and DC Power optimizers. The PV moudul/Panel as per the latest edition of IEC PV module qualification test or equivalent BIS standards. Crystalline Silicon Solar Cell Modules IEC 61215. In addition, the modules must conform to IEC 61730 Part-1 - requirements for construction & Part-2 requirements for testing, for safety qualification or equivalent IS. DC Power optimizers need to provide module level Maximum Power Point Tracking (MPPT) for mitigating all types of modules mismatch-loss, manufacturing tolerances & partial shading. Power Optimizer DC/DC converter with constant string voltage feature should be able to instantaneously clamp DC Voltage to 1 V DC (Safe DC) per optimizer when AC power is shut off for installer and take care of firefighter safety. (1 dc optimizer for 2 module). Quantity of Panel and Optimizer 10 % Spare need to consider. BI01010001010000000000000515BI0100001113 800 KW
2 1.2 Supply, installation, testing and commissioning of 50 KW-3 phase On Grid String Inverter for the Medium Voltage Grid 480V AC Output voltage with an effective efficiency of more than 97.5%.Grid Tie Inverter should be designed to work with Power Optimizers Module Level MPPT (Module power point tracking ) providing Constant string voltage with IP68 protection with Canopy Arrangement and should have anti-islanding feature. BI01010001010000000000000515BI0100001114 800 KW
3 1.3 Supply and Installation of Module Mounting Structure. Fixed Tilt Module Mounting Structure with Hot Dip Galvanized Mild Steel 80 micron thickness, designed for wind load of 150 KMPH.The mounting structure steel will be as per latest IS 2062: 1992 and galvanization of the mounting structure will be in compliance of latest IS 4759. The minimum clearance of the structure from the roof/floor level should be 1 mtrs. and upper limit should be as per site conditions complete with concreate structure .And Contruction of Foundations for Module Mouting Structure of M20 Grade R.C.C of size 350 mm *350 mm *600 mm with 100 mm P.C.C. with all required supply of all construction material and required labour. BI01010001010000000000000515BI0100001115 800 KW
4 1.4 Supply of G.I. 600 mm long "J" Type Foundation with SS 316 Nut, Bolts and Fastners with having 100 mm thread with Required washer and packing Arrangements. BI01010001010000000000000515BI0100001116 800 KW
5 1.5 Supply and installation of DC distribution board shall be provided in between solar array and On-Grid Inverter. The junction boxes shall be suitable configuration also made of FRP / Thermo Plastic with impact resistant transparent cover, waterproof, dust free, vermin with IP68 protection. 1 DCDB for each inverter. BI01010001010000000000000515BI0100001117 800 KW
6 1.6 Supply and laying of DC Cable from Solar modules to Inverter Incomer including required cable in uPVC Conduit Piping and ducting. BI01010001010000000000000515BI0100001118 12000 M
7 1.7 LT DB Panel- for combining all above Grid Tie Solar inverter with suitable copper bus bar of rating for (RYB), Input and output glands complete with 1 Nos. Class I + II Surge Protective Device, 1 Nos. Multi-Function Meter complete with CTs, Incomers MCB /MCCB/ACB & Outgoing MCCB/ACBs as per required capacity , suitable for cable, Polycarbonate IP 68 Enclosure complete . and capable to intrigate PLC/SCADA (1 LTDB for 3 inverter) BI01010001010000000000000515BI0100001119 3 Each
8 1.8 Supply and Installation of Type-2 Lightening Surge Arrester IP-20 grade with all Required arrangement of BI01010001010000000000000515BI0100001120 2 Nos.
9 1.9 Complete Earthing of Power Plant BI01010001010000000000000515BI0100001121 1 Job
10 2 Sub Station SITC of 1000 KVA Step-up Transformer with following specifications .\nService /Type : Indoor /Outdoor /Oil immersed/OLTC\nb) Rating :1000 KvA\nc) Cooling : ONAN\nd) Rated No Load voltage :I )HV-33KV/ii)LV-415v\ne)Frequency : 50 Hz\nf) Winding/Oil Temporize: 70 Deg C/80Deg C (Max)\ng) Winding Material : 99.9% Electrolytic Copper \nh) No. of Phases: 3\ni) Terminal Arrangement : HV-Cable Box /LV-Cable/Bus Duct Box \nj)Type of Tapp Changer :Off Load Tapp Changer\nk)Tapping Range :+5%to-10% in 16 steps/17 Positions\nl) No Load /Load Losses: As per IS 1180 \n BI01010001010000000000000515BI0100001123 1 nos
11 2.1 supply and laying of 50mm x6mm G.I.strip complete in all respect BI01010001010000000000000515BI0100001124 25 Mtr
12 2.2 supply and burying of safe earthing electrode T-39 cu copper coated up to 300mmcomplete BI01010001010000000000000515BI0100001125 6 nos
13 2.3 Construction of foundation for 1000 KVA Transformer BI01010001010000000000000515BI0100001126 1 job
14 2.4 Construction of Trench for 1000 KVA Transformer BI01010001010000000000000515BI0100001127 20 mtr
15 2.5 Construction of Trench Cover for 1000 KVA Transformer BI01010001010000000000000515BI0100001128 20 mtr
16 2.6 Supply and fixing of Termination/ jointing kit (Outdoor) BI01010001010000000000000515BI0100001129 4 Set
17 2.7 supply and laying of 3 core standard aluminum conductor XLPE (Cross linked polyethylene ) insulated PVC bedded ,Galvanized flat steel strip armored cables confirming to I.S. 7098 (Part-II with latest amendments ) 33 KV grade at a depth of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on side and on top put across .The armoring of cable shall be properly connected with earth conductor by clamps etc. 120 sq. mm 3 core\n BI01010001010000000000000515BI0100001130 600 Mtr
18 2.8 LT AC Panel shall be CPRI tested design and manufactured by an approved manufacturer. All panel boards shall be IP 65 or better. Distribution panels shall comply with the latest Relevant Indian Standards and Electricity Rules and Regulations and shall be as per IS-13947-1993. Distribution panels shall be 2 mm thick sheet steel cabinet for outdoor installation, Double front, wall mounting type and shall be form 1b construction. The Distribution panels shall be totally enclosed, completely dust and vermin proof and shall be with hinged doors and folded covers, Neoprene gasket, padlocking arrangement and bolted back. All removable/ hinged doors and covers shall be grounded by flexible standard connectors. Distribution panel shall be suitable for the climatic conditions as specified in Special Conditions. Steel sheets used in the construction of Distribution panels shall be 2 mm thick and shall be folded and braced as necessary to provide a rigid support for all components. The general construction shall confirm to BIS-8623-1977 (Part-1) for factory built assembled switchgear & control gear for voltage up to and including 1100 V AC.Bus bar and interconnections shall be of high conductivity electrolytic grade copper as complying with requirement of IS : 5082 – 1981 and of rectangular cross section suitable for carrying the rated full load current and short circuit current. Suitable rating of Incomers MCB /MCCB & Outgoing MCCB/ACBs as per required capacity. Bus bars and interconnections shall be insulated with heat shrinkable sleeve of 1.1 KV grade. Bus bars shall be supported on glass fiber reinforced thermosetting plastic insulated supports at regular intervals to withstand the force arising from in case of short circuit in the system. Maximum current density for the busbars shall be 1.4 A/sq.mm for copper busbars. BI01010001010000000000000515BI0100001131 1 Each
19 2.9 Supply and laying of AC LT Cable and Controll Cable from Inverter Outgoing to LT ACDB and Main LT Panel To Transformer including required cable trenches with GI Grating Cover, cable tray, ducts etc . BI01010001010000000000000515BI0100001132 1200 m
20 3 Supply of 33 KV H.T. incoming Outgoing and Extra 630 amp VCB Panel . BI01010001010000000000000515BI0100001133 3 nos
21 3.1 Solar power meter as per UPPCL requeimrnet for power transfer BI01010001010000000000000515BI0100001134 1 no
22 3.2 SCADA / Automation and Site Development Supply and Installation of complete SCADA / Automation on MODBUS / RS-485 platform with all required sensors, control/Instrumentation Cables, Networking arrangements, Softwares, Hardwares, storage, Computer, Display 50'' size and required furnitures. BI01010001010000000000000515BI0100001136 1 Nos
23 3.3 Modular Control Desk for Controll Room with Work Station Chairs with 2 Nos Air Condition (1.5 Ton) BI01010001010000000000000515BI0100001137 1 Job
24 3.4 H.P or equvalent local control station hardware with latest configuration i- 7 processor, 1TB - HDD , 8 GB RAM , DVD , Minimum 32" LED LG/Samsung or equivalent, mouse & key board BI01010001010000000000000515BI0100001138 2 Job
25 3.5 Security Survelliance one PTZ Camera and 4 set Outdoor IP Camera with NVR BI01010001010000000000000515BI0100001139 1 Job
26 3.6 HP/ Cannon2004n Equivalent Printer and Scanner BI01010001010000000000000515BI0100001140 1 nos
27 3.7 Automatic Solar Panel water Spray Cleaning with Pressure jetting machine for washing of Solar modules. BI01010001010000000000000515BI0100001141 1 Job
28 3.8 NOC from Different Departments, Application Fee, Regulatory Comission and Petition Charge BI01010001010000000000000515BI0100001142 1 Job
29 3.9 Construction of Pathway with interlocking tiles Roads and Fencing arrangement and dressing of site after execution of work. BI01010001010000000000000515BI0100001143 1 Job
30 4 Construction of HT and LT Panel room as per direction of Eneginer in charge for monitoring the equeipments 16mx7mx4.5m BI01010001010000000000000515BI0100001144 1 Job
31 4.1 construction of control room cum SCADA Room as per direction of Eneginer in charge for monitoring the equeipments size 8 m x 5 m x 4.5m BI01010001010000000000000515BI0100001145 1 Job
32 4.2 Arrangement of Water Grid for Cleaning of Solar Modules with construction of 2 nos. mini Tubewells. BI01010001010000000000000515BI0100001146 2 Nos
33 4.3 Levelling of Land , Execavation of pits and back filling of earth for Solar Panel Mounting Structure Installation BI01010001010000000000000515BI0100001147 1 Nos
34 4.4 Landscaping Works at Konia MPS Campus BI01010001010000000000000515BI0100001148 1 Job
35 4.5 Arrangement of Drainage System around the power plant and Laying of C PVC Pipe with tabs across solar power plant for Cleaning of Solar Panel BI01010001010000000000000515BI0100001149 1 Job
36 4.6 Campus lighting with pole mounting structure of 120 watt LED BI01010001010000000000000515BI0100001150 10 Nos
37 4.7 Construction of weather monitoring including pyranometer, tempereature sensor, solar radiation, wind velocity, wind direction, humidity, module temperature, performance ratio (PR) etc. BI01010001010000000000000515BI0100001151 1 Nos