Road And Building Department-RBD has published Enhancement Of Contract Demand From 589 To 789 Kva Load For Centralized Medical Gas Pipe Line System At Dhh , Balasore . . Submission Date for this Tender is 10-03-2021. Medical Gas System Tenders in Balasore Odisha. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Mar-2021 | Enhancement of Contract Demand from 589 to 789 KVA load for centralized Medical Gas pipe line system at DHH, Balasore. | Date | 10-03-2021 |
Name of Work: Enhancement of Contract Demand from 589 to 789 KVA Load for Centralised Medical Gas Pipe Line System at DHH Balasore against deposit of 6% Supervision Charges. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | 150x150 mm 13 mtr joist RS (34.6 kg/mtr) (SAIL/JINDAL/TATA make) proof of purchase of joist poles should be submitted before agreement) | 1 | No | |
2 | 2 | 150x150 mm 9 mtr joist RS (30.6 kg/mtr) (SAIL/JINDAL/TATA make) proof of purchase of joist poles should be submitted before agreement) | 7 | No | |
3 | 3 | 33 kv v cross arm (22kg) GI | 1 | No | |
4 | 4 | 33kv GI Black clamp for v cross arm (17 kg each) | 1 | No | |
5 | 5 | 33kv F clamp (3.58 kg each) | 1 | No | |
6 | 6 | 33kv pin insulator polymer type | 6 | No | |
7 | 7 | 33kv hard ware fittings (B&S) 90 KN ,4 Bolt | 6 | Set | |
8 | 8 | Disc Insulator (B&S) 90 KN Polymer | 6 | Set | |
9 | 9 | 148 sqmm. AAAC from reputed manufacturer having type test certificate | 0.04 | Km | |
10 | 10 | 100x50x6 mm MS channel (each 2.8 mtr long 9.2kg/mtr) 2 nos. | 40 | kg | |
11 | 11 | Earthing coil | 1 | No | |
12 | 12 | Anticlimbing device made of GI barbed wire (2 Kg per support) | 2 | No | |
13 | 13 | GI bolt and nut with washer | 20 | kg | |
14 | 14 | 3x95+1x70+1x16 AB Cable | 0.29 | km | |
15 | 15 | Dead end clamp | 2 | No | |
16 | 16 | Suspension clamp with eye hook | 5 | No | |
17 | 17 | Pole clamp witheye hook for ABC | 7 | No | |
18 | 18 | LT stays set | 4 | Set | |
19 | 19 | 7/12 (SWG) GI Stay wire | 20 | kg | |
20 | 20 | LT stay clamp | 4 | No | |
21 | 21 | Lt stay insulator | 4 | No | |
22 | 22 | Piercing connector | 2 | No | |
23 | 23 | Neutral connector | 2 | No | |
24 | 24 | Red oxide paint | 8 | Ltr | |
25 | 25 | All. Paint | 8 | Ltr | |
26 | 26 | Black paint | 1 | Ltr | |
27 | 27 | Danger board | 3 | No | |
28 | 28 | Sundries | 1 | Ls | |
29 | 29 | Material cost for concreting of RS joist pole 1.5 mtr X0.3 mtr X0.3 mtr=0.135 cum (PCC 1:3:6) | 8 | No | |
30 | 30 | Material cost for concreting of stay (0.5 mtr X 0.5 mtr X 0.5 mtr = 0.125cum-PCC 1:3:6) | 4 | No | |
31 | 31 | ERECTION CHARGES FOR JOIST POLE | 2 | No | |
32 | 32 | Other erection charges | 26 | No | |
33 | 33 | 150x150 mm 11 mtr joist RS (34.6 kg/mtr) (SAIL/JINDAL/TATA make) proof of purchase of joist poles should be submitted before agreement) | 2 | No | |
34 | 34 | 100x50x6 mm MS channel (each 2.8 mtr long 9.2kg/mtr) 2 nos. | 250 | kg | |
35 | 35 | 75 X 40X6 mm MS Channel ( each 2.8 mtr long 6.8 kg/mtr) 4 no. | 100 | kg | |
36 | 36 | 50X50X5 mmMS Angle (each 2.8 mtr long 4.5 kg/mtr) with side angle | 80 | kg | |
37 | 37 | 18 mm GI HT Stay set complete | 2 | set | |
38 | 38 | 7/10 (SWG) GI Stay wire (Dia4.47 mm) (10kg/stay) | 20 | kg | |
39 | 39 | 11KV Stay insulator Type C | 2 | No | |
40 | 40 | HT Stay clamp for PSC Pole (1.9 kg per span) | 2 | pair | |
41 | 41 | 40 mm nominal bore GI pipe medium gauge esrthing device 3 mtr long | 5 | No | |
42 | 42 | 50 X 6 mm GI Flat | 20 | kg | |
43 | 43 | No 6/8 SWG GI Wire (Dia 4.8 mm) | 30 | kg | |
44 | 44 | 33 kv 3 pole 400 amp 50 Hz AB Switch | 1 | set | |
45 | 45 | 33 kv 3 pole 400 amp HG Fuse with PI | 1 | set | |
46 | 46 | LA 30 KV 10 KA | 3 | No | |
47 | 47 | 148 sqmm. AAAC ( from reputed manufacturer having type test certificate) | 0.04 | km | |
48 | 48 | LT distribution box for 500 kva s/s Detail size (1600x1000x5005) mm fabricated from 2 mm cr steel sheet with mccb (800 Amp three pole). Aluminium busbar for 6 bay with kit kat fuse(400 amp 8 nos.) | 1 | no | |
49 | 49 | 33/0.4 kv 500 kva Cu transformer with tap changer BIS Energy level-ii | 1 | no | |
50 | 50 | 3 & 1/2 core 300 sqmm. PVC Cable (unarmoured) | 15 | mtr | |
51 | 51 | All. Cable socket 300 sqmm. | 30 | no | |
52 | 52 | GI bolt and nut with washer | 60 | kg | |
53 | 53 | Danger board | 2 | no | |
54 | 54 | Red oxide paint | 4 | ltr | |
55 | 55 | All paint | 4 | ltr | |
56 | 56 | Black paint | 0.5 | ltr | |
57 | 57 | Earthing with materials | 5 | no | |
58 | 58 | Sundries | 1 | LS | |
59 | 59 | Erection charges for joist pole | 1 | No | |
60 | 60 | Erection charges for DTR | 1 | No | |
61 | 61 | Other erection charges | 24 | No | |
62 | 62 | Material cost for concreting of RS joist pole 1.83mtr X0.3 mtr X0.3 mtr=0.165 cum (PCC 1:3:6) @4320 | 2 | No | |
63 | 63 | Material cost for concreting of stay (0.5 mtr X 0.5 mtr X 0.5 mtr = 0.125cum-PCC 1:3:6) @ 4320 | 2 | No | |
64 | 64 | Boundary wall with grill gate, metal and sand | 1 | No | |
65 | 65 | Plinth of transformer | 1 | No | |
66 | 66 | 33 KV 3 core 300 sqmm XLPE Cable (armoured) | 85 | mtr | |
67 | 67 | Heat shrinkable jointing kit for 3CX95 mm 33 KV XLPE Cable (Out door) | 6 | no | |
68 | 68 | Material cost for cable trench with removable cover | 15 | rmtr | |
69 | 69 | 16 mm MS bolt & nuts with washer | 10 | kg | |
70 | 70 | All cable lug of different size | 20 | no | |
71 | 71 | 40 mm nominal bore GI pipe medium gauge earthing device 3 mtr long | 2 | no | |
72 | 72 | Earthing with materials | 2 | no | |
73 | 73 | Sundries | 1 | Ls | |
74 | 74 | Dismantling of 33 KV 20/5 Amp metering cubicle | 1 | No |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail