Repair/Rewinding Of All Types Of Fans And Repair/Maint Of Summer Cooling Appliances ( Desert Coolers , Water Coolers , Refrigerators , Voltage Stablisers And Air Conditioners ) Including Allied Works At Ebs , Bhojraj And Hisar Mil Stn Repair/Rewindi, HISAR MILITARY STATION-Haryana

Military Engineer Services-MES has published Repair/Rewinding Of All Types Of Fans And Repair/Maint Of Summer Cooling Appliances ( Desert Coolers , Water Coolers , Refrigerators , Voltage Stablisers And Air Conditioners ) Including Allied Works At Ebs , Bhojraj And Hisar Mil Stn Repair/Rewindi. Submission Date for this Tender is 24-03-2021. Electrical Maintenance Tenders in HISAR MILITARY STATION Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

27107494
Corrigendum : Repair/Rewinding Of All Types Of Fans And Repair/Maint Of Summer Cooling Appliances ( Desert Coolers , Water Coolers , Refrigerators , Voltage Stablisers And Air Conditioners ) Including Allied Works At Ebs , Bhojraj And Hisar Mil Stn Repair/Rewindi
National Competitive Bid
Indian
Haryana
HISAR MILITARY STATION
24-03-2021

Tender Details

Repair / Rewinding Of All Types Of Fans And Repair / Maint Of Summer Cooling Appliances ( Desert Coolers , Water Coolers , Refrigerators , Voltage Stablisers And Air Conditioners ) Including Allied Works At Ebs , Bhojraj And Hisar Mil Stn Repair / Rewinding Of All Types Of Fans And Repair / Maint Of Summer Cooling Appliances ( Desert Coolers , Water Coolers , Refrigerators , Voltage Stablisers And Air Conditioners ) Including Allied Works At Ebs , Bhojraj And Hisar Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 37600.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/Rewinding of all types of fans and Repair/Maint of Summer cooling appliances (Desert Coolers, Water Coolers, Refrigerators, Voltage stablisers and Air Conditioners) including allied works at EBS, Bhojraj and Hisar Mil Stn under GE (West) Hisar
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down ceiling fan of any make and 1200mm sweep at site, cleaning dust and opening up for examination, cleaning all parts and providing fresh lubricant to bearing/bush (oil or grease reqquired) fixing the fan in position after assembling and adjustment for proper running including replacing of cable PVC copper flexible of size 23/0.0076 three core from ceiling rose to fan and other parts if required including testing for smooth running as specified. Note:- Cost of bearings, bushes, capacitors and other spares etc shall be measured and paid for separately as supply only. 1000 Each
2 2 All as per Ser item No 1 here-in-before but ceiling fan 1400mm sweep. 20 Each
3 3 All as per Ser item No 1 here-in-before but exhaust fan 450/380mm sweep. 20 Each
4 4 Supply only capacitor 2.5 mfd to 3.15 mfd dry type with PVC clamp make of capacity Epcos/Unistar/Usha complete all as specified and directed. 900 Each
5 5 Supply only of rubber bush complete with nut bolt, fork hook and spilt pin, washer suitable for existing ceiling fan 1200mm/1400mm sweep complete all as specified and directed. 100 Each
6 6 S&F in replacement electronic ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified and directed. 25 Each
7 7 S&F in replacement Wall mounting Fan 400 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers complete all as specified and directed. 2 Each
8 8 Dismantling carefully ceiling fans (any make) of 1200mm sweep for cutting down & removing old copper winding wire and M&L for rewinding the same with new super enameled copper wire of suitable size including providing insulation by varnishing, oiling and greasing complete all as specified and directed. 1000 Each
9 9 Dismantling carefully ceiling fans (any make) of 1400mm sweep for cutting down & removing old copper winding wire and M&L for rewinding the same with new super enameled copper wire of suitable size including providing insulation by varnishing, oiling and greasing complete all as specified and directed. 20 Each
10 10 Taking out complete windings, bearings/bushes, papers, tapes, flexible wire, shaft, check nut, frame of exhaust fan of size 380mm AC 230volts, 50 Hz 900/1400 RPM and M&L for rewinding with insulated copper windings wire of suitable size and replacement of bushes, bearings, tubes, papers, shafts, check nuts, bolts and nuts, capacitors, twin core copper wire, greasing, varnishing assembling and testing complete all as specified and directed. Note Cost of bearings, bushes, capacitors and other spares, if provided shall be measured and paid for separately under respective item of this schedule as supply only. 20 Each
11 11 S&F in replacement of shaft for ceiling fan of any sweep and fixing in position for smooth functioning of ceiling fan complete all as specified and directed. 40 Each
12 12 Replacement PVC canopy for ceiling fans of any sweep and make and fixing in position complete all as specified and directed. 200 Each
13 13 Supply only of ball bearing. Make NBC/SKF, TATA for exhaust fan upto 450/380 mm sweep . 10 Each
14 14 Supply only of blades of ceiling fan of any sweep & make complete all as specified and directed. 20 Each set of three
15 15 Supply only of capacitor 4 to 6 mfd for exhaust fan complete all as specified and directed. Make: USHA, Shriram, Unistar/Epcos. 20 Each
16 16 Supply only of ball bearing . Make NBC, SKF, TATA for ceiling fan 1400mm sweep. 15 Each
17 17 All as per Ser item No 16 here-in-before but ceiling fan 1200mm sweep. 800 Each
18 18 Supply only bush gun metal to match the ceiling fan of size 1200mm sweep 20 Each
19 19 All as per Ser item No 18 here-in-before but ceiling fan 1400mm sweep. 10 Each
20 20 S&F in replacement Ventilating Fan 200 mm sweep, 230 volts, fixed on wall with suitable size nut, bolts and washers and connection complete all as specified & directed. 10 Each
21 21 Machining work in body of ceiling fan by taking out worn out bush, boring hole to accommodate ball bearings complete all as specified and directed. 60 Each Job
22 22 S&F in replacement MS down rod of 15mm dia suitable for fan in any length including threading , drilling holes complete all as specified and directed. 20 RM
23 23 Supply only blades of exhaust fan 380/300 mm of any make complete all as specified and directed. 5 Each Set
24 24 Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed at site. Note :- (in replacement of spare part will be measured and paid separately under appropriate items ). 50 Each Job
25 25 S&F in replacement new remote assembly for split type AC 1.5/2 ton of any make & existing model complete all as specified and directed. . 4 Each
26 26 Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler/window AC etc air tight complete all as specified and directed. 2 Sqm
27 27 S&F in replacement of fan moter of Capacity 165 to 330 ltr suitable for refrigerator of any make and capacity complete all as specified and directed by Engr in charge. 2 Each
28 28 Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC sheathed one twin core cable flat or circular of size 10sqmm complete all as specified and direcred at site. 150 Rm
29 29 Dismantling and taking out exiting defective Copper tubing off Size of any description & in any position and supplying and fixing new copper tubing special annealed pressure copper purity min 99.9% and making flairing at both ends for connections including Brass nut of any size as required and incl insulating material etc and testing complete all as specified and directed. 20 Rm
30 30 M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint including dismantling old cross arms, bracing supports clamps complete all as specified and directed . 5 Kg
31 31 Taking out window type AC 1.5/2 ton and reinstallation including window opening cutting and provision of packing material as per site requirement including closing of old opening and making new opening all as specified and directed at site. 2 Each job
32 32 Taking out existing damaged/unserviceable copper tube insulation of any description & in any position and supply and fixing new insulation over copper tube of any size complete all as specified and directed. 10 Rm
33 33 S&F in replacement of PCB board suitable for refrigerator of existing make and capacity 165 ltr to 300ltr complete all as specified and directed. 5 Each
34 34 S&F in replacement compressor of window type air conditioner 1.5/2 Ton capacity of existing make and providing new sealed compressor unit of same size and make, connecting up suction and discharge pipe with gas welding, pressure testing, leakage rectification vaccumising and including initial charging of Refrigerant gas R-22, compressor oil, testing commissioning including taking down old U/s compressor, complete all as specified and directed .\n 8 Each
35 35 All as per item No 34 but in replacement with new sealed compressor unit for split type AC of 1.5/2 ton capacity. 8 Each
36 36 S&F in replacement of running capacitor 36 MFD complete all as specified and directed. 30 Each
37 37 S&F in replacement of starting capacitor 45 MFD doul complete all as specified and directed. 25 Each
38 38 S&F in replacement of starting relay for 1.5/2 ton capacity complete all as specified and directed. 10 Each
39 39 S&F in replacement of thermostat switch for any capacity window/split type air conditioner complete all as specified and directed. 10 Each
40 40 S&F in replacement of over load protector for any type AC 1.5/2 Ton capacity complete all as specified and directed. 10 Each
41 41 S&F in replacement of PVC air filter suitable for 1.5/2 ton window type air conditioner of any make complete all as specified and directed. 20 Each
42 42 S&F in replacement of condenser fan blade suitable for 1.5/2 ton window type air conditioner of any make complete all as specified and directed. 8 Each
43 43 S&F in replacement of condenser fan motor 1/5 HP 230 volt AC Cooper winding single phase double shaft suitable for 1.5 ton window type AC complete all as specified and directed. 4 Each
44 44 S&F in replacement of condenser fan motor copper winding single phase 230 volt AC suitable for 1.5/2 Ton capacity split AC of existing make complete all as specified and directed. 8 Each
45 45 S&F in replacement of front grill suitable for window type air conditioner capacity 1.5 Ton as per existing complete all as specified and directed. 4 Each
46 46 S&F in replacement Single pole and neutral, Sheet Metal enclosure with Socket plug Top and MCBs. and two pin and earth plug and socket with one single pole MCB 25 Amps compelte all as specified and directed. 10 Each
47 47 S&F in replacement of copper cooling coil assembly suitable for 1.5/2 Ton window type air conditioner of any make including charging of refrigerant gas, testing, commissioning complete all as specified and directed. 2 Each
48 48 M&L for taking down window/split type air conditioner of 1/1.5/2 Ton capacity / make / size at site, opening top and side covers disconnecting all electrical controls components and cleaning the complete units with electric blower and spraying clean water, descaling with coil shine solution in both side of cooling coil and condenser, brush cleaning with nylon brush and washing with clean water, refixing the covers and making electrical connection of all the controls and components, installing back the same on site testing, commissioning incl black painting to bottom complete all as specified and directed. 80 Each
49 49 S&F in replacement of electric wiring kit suitable for 1.5 Ton window type AC of any make complete all as specified and directed. 15 Each
50 50 M&L for Gas recharging in window/split type AC 1.5 Ton/ 2 Ton capacity of any make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed. 40 Kg
51 51 S&F in replacement of revolving motor kit for louvers (for AC grill) in window type AC 1.5 Ton of any make and model complete all as specified and directed. 5 Each
52 52 S&F in replacement of PCB board suitable for 1.5/2 Ton window/split AC including display & remote of existing make complete all as specified and directed. 12 Each
53 53 Taking out Split type AC 1.5/2 ton and relocation/ reinstallation as per site requirement including all connecting accessories i.e back plate nuts bolts etc. All as specfied and directed at site.(Copper piping will be measured and paid separately) 5 Each job
54 54 S&F in replacement Outdoor condensing unit of split type AC of capacity 1.5/2 TR capacity & fixing new condensing unit with Anti Corrosive blue fins, complete with condensing coil, coil frame, wiring kit starting and running capacitor, relay condensing motor, with blade complete all as specified and directed. 2 Each
55 55 Taking down old sealed unit of refrigerator 165-185 ltrs capacity of any make and providing new sealed compressor of same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and including initial charging of refrigerant gas, testing commissioning complete all as specified and directed. 5 Each
56 56 All as per item No 55.00 but 190 to 230 ltrs capacity. 2 Each
57 57 All as per item No 55.00 but 240 to 330 ltrs capacity.\n 2 Each
58 58 S&F in replacement of Over loding relay suitable for low/high speed refrigerator compressor of any capacity complete all as specified and directed. 10 Each
59 59 S&F in replacement of thermostat suitable for any capacity refrigerator complete all as specified and directed. 8 Each
60 60 S&F in replacement of freezer with cooling coil for 165 to 220 ltrs capacity refrigerator of existing make complete all as specified and directed. 2 Each
61 61 All as per item No 84.00 but for 230/286/300/310 liters capacity refrigerators. 1 Each
62 62 S&F in replacement of lamp 15 watt screw / Pin type suitable for any make and capacity refrigerator complete all as specified and directed. 2 Each
63 63 S&F in replacement condensing unit of window type AC of capacity 1.5/2 TR capacity with anti Corrosive paint. fins, condensing coil, coil frame, wiring kit starting and running capacitor, relay condensing motor, with blade complete all as specified and directed. 2 Each
64 64 M&L for Charging with refrigerant gas 134a after vacuuming /pressure testing and leakage testing including flushing the system in the refrigerator of any make of 165 to 220 ltrs capacity complete. all as specified and directed. 15 Kg
65 65 S&F in replacement of plug top 5 Amps 3 pin, ISI marked complete all as specified and directed. 20 Each
66 66 S&F in replacement PVC cable for lead wire pvc seathed 3 core size 23/0.0076 of multistranded copper conductors for Desert coolers/ refrigerators, Make Plaza/Havells/Finolex. 50 RM
67 67 M&L for taking down sealed unit of deep freezer upto 320 ltrs capacity of any make and providing in replacement new sealed compressor of same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and including initial charging of refrigerant gas, testing commissioning complete all as specified and directed. 2 Each
68 68 All as per Ser item No 67.00 here-in-before but 500 ltrs capacity deep freezer. 1 Each
69 69 S&F in replacement of Over loding relay suitable for deep freezer upto 320 Ltrs capacity complete all as specified and directed. 2 Each
70 70 S&F in replacement of thermostat suitable for deep freezer upto 320 Ltrs capacity complete all as specified and directed. 2 Each
71 71 S&F in replacement of fan motor suitable for deep freezer any type complete all as specified and directed. 2 Each
72 72 M&L for taking down old unserviceable compressor of water cooler of capacity 40/80 litres any make/size and providing new sealed compressor and connecting up suction and discharge copper pipe with gas welding, pressure testing of leakage, leakage rectification, vacumising and including initial charging of refrigerant gas R 22, testing, commissioning complete all as specified and directed. 9 Each
73 73 All as per item No 72 but water cooler of capacity 60/120 litres complete all as specified and directed. 4 Each
74 74 All as per item No 72 but water cooler of capacity 150 litres. \n 2 Each
75 75 S&F in replacement of starting capacitor 80-100 mfd complete all as specified and directed. 6 Each
76 76 All as per item No 75 but 40-60 MFD. 8 Each
77 77 All as per item No 75 but 60-80 MFD. 5 Each
78 78 S&F in replacement of thermostat switch for water cooler any cap complete all as specified and directed. 18 Each
79 79 S&F in replacement of condenser fan motor 1/ 3.5 HP 250 Volts AC Single phase suitable for water cooler complete all as specified and directed. 8 Each
80 80 All as per item No 79 but 4/10 HP. 6 Each
81 81 S&F in replacement of starting relay kit suitable for any make & capacity water cooler complete all as specified and directed. 12 Each
82 82 S&F in replacement of condenser fan blade for fan motor suitable for water cooler of any make/capacity complete all as specified and directed. 10 Each
83 83 M&L for Gas charging in water cooler of any capacity and make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified and directed. 20 Kg
84 84 S&F in replacement of electric wiring kit suitable for water cooler of any make and capacity complete all as specified and directed. 2 Each
85 85 S&F in replacement of running capacitor 30 mfd complete all as specified and directed. 8 Each
86 86 All as per item No 85.00 but 25 mfd. 8 Each
87 87 All as per item No 85.00 but 10 mfd. 7 Each
88 88 S&F in replacement of PVC float valve assembly suitable for water cooler of any size/capacity non metallic body complete all as specified and directed. 3 Each
89 89 S&F in replacement of receptacle tray as per existing complete all as specified and directed. 1 Each
90 90 S&F in replacement of PVC cable for lead wire pvc seathed 3 core size 40/0.0076 of multistranded copper conductors for water coolers/ AC, complete all as specified and directed Make : Plaza/Havells/Finolex. 50 RM
91 91 S&F in replacement indoor unit of split type AC's 1.5 ton with suction, discharge, water drainage pipe line, wall mounting brackets etc,complete all as specified and directed. 2 Each
92 92 S&F in replacement PVC waste pipe 32mm, dia with complete fittings suitable for water cooler of any make and capacity complete all as specified and directed. 25 RM
93 93 S&F in replacement of desert cooler submersible pump single phase complete all as specified and directed. 280 Each
94 94 S&F in replacement of desert cooler fan motor duly wounded aluminium suitable for operation on 230 V single AC supply 3 speed 1400 RPM complete all as specified and directed. 50 Each
95 95 S&F in replacement of selector switch for controlled speed complete all as specified and directed. 30 Each
96 96 S&F in replacement of wood wool pad superior quality (As per sample kept in GE’s office) for desert cooler of capacity 4000 Cum/hr 5000 Cum/hr having minimum weight 450 gms complete all as specified and directed. 290 Each set of three
97 97 S&F in replacement of capacitor 4 mfd suitable for desert cooler complete all as specified and directed. 100 Each
98 98 S&F in replacement of PVC pipe 15 mm dia of superior quality (As per sample kept in GE’s office) complete all as specified and directed. 50 RM
99 99 Dismantling , cutting and taking out old winding of desert cooler fan motor of any make and M&L for rewinding of the same with super enameled copper winding wire and providing shallac varnish, testing commissioning complete all as specified and directed. 25 Each
100 100 S&F in replacement of PVC water distributor 3 way for desert cooler of superior quality (As per sample kept in GE’s office) complete all as specified and directed. 20 Each
101 101 S&F in replacement of PVC fan blade suitable for 18/20 inch sweep desert cooler motor complete all as specified and directed. 50 Each
102 102 S&F in replacement of desert cooler body (overall mimimum size 26 inch x26 inchx39 inch) made out of 22 gauge galvanized sheet,depth of water tank shall not be less than 9/10 inch,including front adjustable grill both side i.e. horizontally and vertically and suitable three side slotted shutter Including necesry fabrication, belding wks complete all as specified and directed. 12 Each
103 103 M&L for spray painting of desert cooler of any make/capacity with two coats of synthetic enamel paint of approved colour after the preparation of old painted surface inside & Outside body of cooler complete all as specified and directed. 5 Each
104 104 Supply & fixing inreplecement Voltage Stabilizer of capacity 4 KVA for automatic operation, Single Phase, naturally air cooled, indoor type, designed for input variation between 170 Volt to 270 Volt and with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and connecting up all as per manufacturer’s instructions & as directed. 4 Each
105 105 S&F in replacement adjustable front grill made of GI sheet ,having with air direction control system with knob, P/T switch, indicator lamp, complete suitable for 20"/24" desert cooler. complete all as specified and directed. 5 Each Job
106 106 S&F in replacement of indicating lamp, 230 volts complete all as specified and directed. 5 Each
107 107 M&L for taking down water cooler of any capacity /make / size from site, transporting to work site and opening side covers of water cooler and disconnecting all components and controls and condenser fan motor, cleaning condenser with blower and washing with water and descaling with acid by spraying on both side of condensor. Cleaning with nylon brush and washing with clean water, refixing condensor fan motor, making electrical connection of relay, over-load etc. refixing side covers, installing back the same on site, testing and commissioning complete all as specified and directed. 1 Each\nJob
108 108 S&F in replacement Plug top 16A, 3 pin, 230 AC, ISI marked complete all as specified and directed. 10 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail