Water Resources and Irrigation Local Bodies Closing in 0 days TDR #27105459

Providing 150 Fhtcs And Street Main Extension At Kodassery Panchayath Area From Ongoing Project -Part Ii Jjm-Wss To Kodassery Panchayath In Thrissur District- Providing 150 Fhtcs And Street Main Extension At Kodassery Panchayath Area From Ongoing Project

Issued by Local Bodies · Kodassery, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Mar 2021
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
2800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kodassery → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Providing 150 Fhtcs And Street Main Extension At Kodassery Panchayath Area From Ongoing Project -Part Ii Jjm-Wss To Kodassery Panchayath In Thrissur District- Providing 150 Fhtcs And Street Main Extension At Kodassery Panchayath Area From Ongoing Project -Part Ii .

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Mar-2021 TIME EXTENSION CORRIGENDUM Date 06-Mar-2021
2 06-Mar-2021 TIME EXTENSION CORRIGENDUM2 Date 15-Mar-2021
3 16-Mar-2021 TIME EXTENSION CORRIGENDUM4 Date 25-Mar-2021

BOQ

Work Name:JJM-WSS to Kodassery Panchayath in Thrissur District- Providing 150 FHTC's and Street Main Extension at Kodassery Panchayath area from ongoing Project - Part II
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Providing Service connections at various wards from existing lines (FHTC).
21.001Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI010000111330Nos
31.002Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI010000111430Nos
41.003Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing CI mains up to 125 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI010000111530Nos
51.004Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI010000111630Nos
61.005Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing AC / GI mains from 150mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, GI / MS / SS Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.BI01010001010000000000000515BI010000111730Nos
71.006Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers.BI01010001010000000000000515BI0100001118600metre
81.007Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers.BI01010001010000000000000515BI0100001119150Nos
91.008Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers.BI01010001010000000000000515BI0100001120150Nos
101.009Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.BI01010001010000000000000515BI0100001121420metre
111.01Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous roadBI01010001010000000000000515BI0100001122126sqm
121.011Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 )1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)BI01010001010000000000000515BI010000112318.9cum
131.012Geo tagging of Service Connections (FHTC)BI01010001010000000000000515BI0100001124150No
142Street Main ExtensionBI01010001010000000000000515BI0100001125
152.001Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR)BI01010001010000000000000515BI0100001126751.5cum
162.002Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :\"Ordinary Rock. (Ref. Item No. 2.13.1 of DSR)BI01010001010000000000000515BI0100001127751.5cum
172.003Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes.BI01010001010000000000000515BI0100001128690.6metre
182.004Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).63 mm nominal outer dia pipes.BI01010001010000000000000515BI0100001129852.9metre
192.005Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).75 mm nominal outer dia pipes.BI01010001010000000000000515BI0100001130434.1metre
202.006Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\"BI01010001010000000000000515BI0100001131308.4metre
212.007Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials).110 mm nominal outer dia pipes.BI01010001010000000000000515BI0100001132600metre
222.008Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 40 mm dia nominal bore Data derived from item no.18.12.5 of DARData for 10 mBI01010001010000000000000515BI010000113360metre
232.009Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 50 mm dia nominal bore Observed Data derived from item no.18.12.6 of DARData for 10 mBI01010001010000000000000515BI010000113430metre
242.01Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 65 mm dia nominal boreData derived from item no.18.12.7 of DARData for 10 mBI01010001010000000000000515BI010000113530metre
252.011Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. but excluding cost of pipes and fittings - External work. 80 mm dia nominal bore Data derived from item no.18.12.8 of DARData for 10 mBI01010001010000000000000515BI010000113630metre
262.012Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation.BI01010001010000000000000515BI0100001137865.8metre
272.013Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous roadBI01010001010000000000000515BI0100001138450.9sqm
282.014Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)BI01010001010000000000000515BI010000113922.545cum
292.015Supply of PVC Pipe, 6kg/cm2, 50mm Dia.BI01010001010000000000000515BI0100001140612.306metre
302.016Supply of PVC Pipe, 10kg/cm2, 50mm Dia.BI01010001010000000000000515BI010000114192.106metre
312.017Supply of PVC Pipe, 6kg/cm2, 63mm Dia.BI01010001010000000000000515BI0100001142473.382metre
322.018Supply of PVC Pipe, 8kg/cm2, 63mm Dia.BI01010001010000000000000515BI0100001143108.018metre
332.019Supply of PVC Pipe, 10kg/cm2, 63mm Dia.BI01010001010000000000000515BI0100001144288.558metre
342.02Supply of PVC Pipe, 6kg/cm2, 75mm Dia.BI01010001010000000000000515BI0100001145335.376metre
352.021Supply of PVC Pipe, 10kg/cm2, 75mm Dia.BI01010001010000000000000515BI0100001146107.406metre
362.022Supply of PVC Pipe, 6kg/cm2, 90mm Dia.BI01010001010000000000000515BI0100001147176.562metre
372.023Supply of PVC Pipe, 8kg/cm2, 90mm Dia.BI01010001010000000000000515BI0100001148138.006metre
382.024Supply of PVC Pipe, 6kg/cm2, 110mm Dia.BI01010001010000000000000515BI0100001149382.5metre
392.025Supply of PVC Pipe, 8kg/cm2, 110mm Dia.BI01010001010000000000000515BI0100001150153metre
402.026Supply of PVC Pipe, 10kg/cm2, 110mm Dia.BI01010001010000000000000515BI010000115176.5metre
412.027Suuply of PVC SpecialsBI01010001010000000000000515BI010000115211605L.S
422.028Supplying 40 mm GI pipeBI01010001010000000000000515BI010000115360metre
432.029Supplying 50 mm GI pipeBI01010001010000000000000515BI010000115430metre
442.03Supplying 65mm GI pipeBI01010001010000000000000515BI010000115530metre
452.031Supplying 80 mm GI pipeBI01010001010000000000000515BI010000115630metre
462.032Supply of GI SpecialsBI01010001010000000000000515BI01000011572934.15L.S
472.033Supply of CI Air Valve, Conforming to IS 14848 - 2000, Single Orifice, Small Orifice Type S1, Size 25mm.BI01010001010000000000000515BI01000011584No
482.034Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.BI01010001010000000000000515BI01000011591No
492.035Providing and laying D.I Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 :BI01010001010000000000000515BI01000011600.345quintal
502.036Fabrication work with MS flanges to 110mm PVC tail pieceBI01010001010000000000000515BI01000011611L.S
512.037Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 25 mm Single acting Air Valve Observed Data derived from item no.18.59.of DARBI01010001010000000000000515BI01000011625Nos
522.038\"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class I\"Data derived from item no.18.31.1.1of DARBI01010001010000000000000515BI01000011631Nos
532.039Taking connection from the existing line by using Pvc/ Ms/CI saddle or Tee including all labour charges, earth work excavation, refilling, bailing out water, hire for tools etc. complete but excluding cost of materials.BI01010001010000000000000515BI01000011642No
542.04Providing protection tube for air valveBI01010001010000000000000515BI01000011655No
552.041Providing protection tube for sluice valveBI01010001010000000000000515BI01000011661No
562.042Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. (Data Prepared based on PWD SDB - Item No.1009)BI01010001010000000000000515BI0100001167432.9metre
572.043Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade - III ( size range 26.5 mm to 0.075 mm) having CBR Value - 20BI01010001010000000000000515BI0100001168450.9cum

AI Tender Summary

OUR REF NO 27105459
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 25-03-2021
Authority
Authority Name Kerala Water Authority
Work Description Providing 150 Fhtcs And Street Main Extension At Kodassery Panchayath Area From Ongoing Project -Part Ii Jjm-Wss To Kodassery Panchayath In Thrissur District- Providing 150 Fhtcs And Street Main Extension At Kodassery Panchayath Area From Ongoing Project -Part Ii .
Basic Detail
Tender No 20/EE/PD/NTK/2020-21
Bidding Type Tender
Location
City Kodassery
State Kerala
Key Dates
Publish Date 16 Mar 2021
Submission Date 25 Mar 2021
Open Date 27 Mar 2021
Finance
Tender Value Ref. Documents
Tender Fee 2800
EMD 50000
Exemption Not Available
Document List
BOQ_593374.xls
NIT20.pdf
KWAGeneralConditionsforeTenderingV5.pdf
4E27B323-F382-49D4-BD55-E3DDC20C5EA7.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 16, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 06, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 15, 2021
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 25, 2021
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 25, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 27, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_593374.xls

pdf

NIT20.pdf

pdf

KWAGeneralConditionsforeTenderingV5.pdf

html

4E27B323-F382-49D4-BD55-E3DDC20C5EA7.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders