}

Installation Of Khagenhat-Iimini Solar Rli Scheme By Supply And Installation Of Solar Pv System With Dual Axis Manual Tracking System , Centrifugal Pump Sets , Distribution Chamber And Construction Of Spout Chamber On Turn Key Basis In Alipurduar Dist ., Falakata Block, Mouza Khagenhat-West Bengal

Water Resources Department-WRD has published Installation Of Khagenhat-Iimini Solar Rli Scheme By Supply And Installation Of Solar Pv System With Dual Axis Manual Tracking System , Centrifugal Pump Sets , Distribution Chamber And Construction Of Spout Chamber On Turn Key Basis In Alipurduar Dist .. Submission Date for this Tender is 15-03-2021. Submersible Pump Tenders in Falakata Block, Mouza Khagenhat West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

27102936
Installation Of Khagenhat-Iimini Solar Rli Scheme By Supply And Installation Of Solar Pv System With Dual Axis Manual Tracking System , Centrifugal Pump Sets , Distribution Chamber And Construction Of Spout Chamber On Turn Key Basis In Alipurduar Dist .
Open Tender
Indian
West Bengal
Falakata Block, Mouza Khagenhat
15-03-2021

Tender Details

Installation Of Khagenhat-Iimini Solar Rli Scheme By Supply And Installation Of Solar Pv System With Dual Axis Manual Tracking System , Centrifugal Pump Sets , Distribution Chamber And Construction Of Spout Chamber On Turn Key Basis In Alipurduar Dist .

Key Value

Document Fees
Refer document
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Installation of Khagenhat-II Mini Solar RLI scheme by Supply and Installation of Solar PV system with dual axis Manual Tracking system, centrifugal pump sets, Distribution Chamber , Supply, laying and joining of U.P.V.C pipes & fittings, M.S, G.I, E.R.W pipes & fittings, and construction of spout chamber on Turn Key basis in Alipurduar district. (BOQ1)
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply of U.P.V.C Pipes and fittings BI01010001010000000000000515BI0100001112
2 1.01 140 mm. dia P.V.C. pipe Class- I 140(with a loose matching coupler,class-II) marking IS No. 4985/ 1988 with latest amendments with free solvent cement. BI01010001010000000000000515BI0100001113 252 Meter
3 1.02 110 mm. dia P.V.C. pipe Class- I (with a loose matching coupler,class-II) marking IS No. 4985/ 1988 with latest amendments with free solvent cement. BI01010001010000000000000515BI0100001114 1200 Meter
4 1.03 110 mm. dia P.V.C. pipe class-II ( with a loose matching coupler,class-II) marking IS No. 4985/ 1988 with latest amending with free solvent cement. BI01010001010000000000000515BI0100001115 12 Meter
5 1.04 Coupler(Cl-II) for 140 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988, Part- II with free solvent cement. BI01010001010000000000000515BI0100001116 11 Each
6 1.05 Coupler(Cl-II) for 110 mm. dia P.V.C. pipe ( extra) I.S. 10124/1988, Part- II with free solvent cement. BI01010001010000000000000515BI0100001117 50 Each
7 1.06 110x110x 110 M. P.V.C. Tee with free solvent cement BI01010001010000000000000515BI0100001118 9 Each
8 1.07 140x140x 140 M. P.V.C. Tee with free solvent cement BI01010001010000000000000515BI0100001119 2 Each
9 1.08 140 x 110 Reducer(cl-II) with free solvent cement. BI01010001010000000000000515BI0100001120 4 Each
10 1.09 140 mm. dia 900 bend (cl-II) ( IS. No. 10124/ 88 Part- 8 with latest amendment ) BI01010001010000000000000515BI0100001121 2 Each
11 1.1 110 mm. dia 600 bend(cl-II) ( IS. No. 10124/ 88 Part- 8 with latest amendment ) BI01010001010000000000000515BI0100001122 6 Each
12 1.11 110 mm. dia 900 bend(cl-II) ( IS. No. 10124/ 88 Part- 8 with latest amendment ) BI01010001010000000000000515BI0100001123 13 Each
13 1.12 140 mm. dia IS. NO. 10124/ 88 Part- 4 with latest amendment End cap. BI01010001010000000000000515BI0100001124 1 Each
14 1.13 110 mm.dia IS.NO.10124/88 Part-4 with latest amendment.PVC End Cap.(Cl-III) BI01010001010000000000000515BI0100001125 2 Each
15 1.14 110 mm. dia ( IS. No 10124/88 Part- 6 with latest amendment) F.T.P.(Cl-II) BI01010001010000000000000515BI0100001126 9 Each
16 1.15 140 mm. dia ( IS. No 10124/88 Part- 6 with latest amendment) F.T.P.(Cl-II) BI01010001010000000000000515BI0100001127 2 Each
17 1.16 ISI marked P.V.C.Flexible Hose pipe as per IS 15265 - 100 mm dia BI01010001010000000000000515BI0100001128 60 Meter
18 1.17 Solvent cement extra (Medium duty) BI01010001010000000000000515BI0100001129 2.5 Liter
19 2 Supply of M.S, G.I, E.R.W pipes, fiitings, accessories & Miscellaneous materials BI01010001010000000000000515BI0100001130
20 2.01 G.I. Tripod Set and Inlet & Outlet Pipe Fittings (As per drawing) BI01010001010000000000000515BI0100001131 1 Set
21 2.02 100 mm dia G.I E.R.W. Pipe with flange as per IS 1239 (Part-I)/2004 & 6392/1971, table 17 Specification. BI01010001010000000000000515BI0100001133 24 Meter
22 2.03 150 mm. dia I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve . BI01010001010000000000000515BI0100001134 2 Each
23 2.04 100 mm dia C.I. Sluice Valve I.S.I. 14846/2000 Amd No. 1&2 mark and specification PN- 1.6 sluice valve . BI01010001010000000000000515BI0100001135 2 Each
24 2.05 ?100 mm NTP /Alfa-Alfa Valve as per technical specification BI01010001010000000000000515BI0100001136 9 Each
25 2.06 100 mm dia 90º G.I bend (With priming arrangement) ISI 1239 (Part-II)/1992 Specification mark BI01010001010000000000000515BI0100001137 2 Each
26 2.07 100 mm dia. Foot Valve Threaded type IS: 4038/1986 BI01010001010000000000000515BI0100001138 2 Each
27 2.08 100 mm dia, 2mm thickness,30mm width Heavy Duty Hose Clamp fitted with bolts & nuts BI01010001010000000000000515BI0100001139 20 Each
28 2.09 100 mm dia C.I Tail piece one End flanged other End Grooved BI01010001010000000000000515BI0100001140 6 Each
29 2.1 100 mm dia C.I. combind Tail Piece with adopter both side grooved BI01010001010000000000000515BI0100001141 2 Each
30 2.11 80X65mm M.S. flanged reducer BI01010001010000000000000515BI0100001142 2 Each
31 2.12 100X80mm M.S. flanged reducer BI01010001010000000000000515BI0100001143 4 Each
32 2.13 M.S Foundation Bolt for Pump motor sets (1.1kg each) BI01010001010000000000000515BI0100001144 8 Each
33 2.14 M.S Foundation Bolt for distribution chamber (1.1kg each) BI01010001010000000000000515BI0100001145 14 Each
34 2.15 Nuts & Bolts IS: 1363 (Part 1 & 3) /1992 of Product Grade-C.\nM 20x80 mm. BI01010001010000000000000515BI0100001146 50 Kg
35 2.16 Nuts & Bolts IS: 1363 (Part 1 & 3) /1992 of Product Grade-C.\nM 20x100 mm. BI01010001010000000000000515BI0100001147 10 Kg
36 2.17 Nuts & Bolts IS: 1363 (Part 1 & 3) /1992 of Product Grade-C.\nM.16x65 mm BI01010001010000000000000515BI0100001148 44 Kg
37 2.18 Nuts & Bolts IS: 1363 (Part 1 & 3) /1992 of Product Grade-C.\nM 16x80 mm BI01010001010000000000000515BI0100001149 10 Kg
38 2.19 Nuts & Bolts IS: 1363 (Part 1 & 3) /1992 of Product Grade-C.\nM 16x 50 mm BI01010001010000000000000515BI0100001150 18 Kg
39 2.2 Foot valve leather washer 100mm dia BI01010001010000000000000515BI0100001151 2 Each
40 2.21 Sal Sleeper (4ft X 6in X 4 in) BI01010001010000000000000515BI0100001152 2 Each
41 2.22 Compresed Asbestos fibre jointing for Quadruped & Tripod set( for raised surface of Flange as per IS-6392)\n300mm.dia(Table-5) BI01010001010000000000000515BI0100001153 2 Each
42 2.23 Rubber Insertion I.S. 638/79 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392)\n150 m dia Ruber Insertion(Table-17) BI01010001010000000000000515BI0100001154 2 Each
43 2.24 Rubber Insertion I.S. 638/79 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392)\n150 m dia Ruber Insertion(Table-5) BI01010001010000000000000515BI0100001155 4 Each
44 2.25 Rubber Insertion I.S. 638/79 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392)\n100 m dia Ruber Insertion(Table-17) BI01010001010000000000000515BI0100001156 6 Each
45 2.26 Rubber Insertion I.S. 638/79 with latest amendment sheet 5 mm. 2 Ply. ( for raised surface of Flange as per IS-6392)\n80 m dia Ruber Insertion (Table-17) BI01010001010000000000000515BI0100001157 12 Each
46 2.27 3C X 4 sqmm copper cable conforming to IS 694 [Busbar to 32 A, TP Main switch and 32 A TP switch to Motor starter] BI01010001010000000000000515BI0100001159 3 Meter
47 2.28 2 X 3C X 2.5 sqmm copper cable conforming to IS 694 in 25 mm GI conduit (ISI-Medium quality)[ Star-Delta Motor starter to Motor] BI01010001010000000000000515BI0100001160 10 Meter
48 3 Supply and Installation of Solar Module & Solar Controller BI01010001010000000000000515BI0100001161
49 3.01 Solar Module: Supply, transport, installation and commissioning of lSI marked as per IS 14286 and ire 61853(1). 61730(1&2), 61710 certified Solar Module of Multi crysta lin elM a nocrvs tilIIine/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity .3.2/1•.1: r-un tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. \nFor 5 HP Off-grid Solar Water Pumping System with Multicrystalline SPV modules - 5525 Wp. BI01010001010000000000000515BI0100001162 11050 Wp
50 3.02 Power conditioning unit with IP54 enclosure:\nSupply, transport, installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine. condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc. The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRSbased data transmission.\n For 5 HP capacity Pump-motor set BI01010001010000000000000515BI0100001163 2 Each
51 4 Rate from Percentage BOQ (BOQ2) BI01010001010000000000000515BI0100001164 1 Nos
52 5 GST on Basic Cost @ 5% BI01010001010000000000000515BI0100001165 1 Nos
53 6 GST on Basic Cost @ 12% BI01010001010000000000000515BI0100001166 1 Nos
54 7 GST on Basic Cost @ 18% BI01010001010000000000000515BI0100001167 1 Nos
55 8 Labour Welfare Cess @ 1% BI01010001010000000000000515BI0100001168 1 Nos
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail