Design , Fabrication , Installation , Testing And Commissioning Of Automatic Starter Cum Control Panel With 1 Incoming And 3 No . Outgoing Feeders Along With Auto Starter Panels For 3 No . Pumping Units Along With Cables And Other Allied Electromecha, Dharap-Jammu And Kashmir

Irrigation And Flood Control Department-IFCD has published Design , Fabrication , Installation , Testing And Commissioning Of Automatic Starter Cum Control Panel With 1 Incoming And 3 No . Outgoing Feeders Along With Auto Starter Panels For 3 No . Pumping Units Along With Cables And Other Allied Electromecha. Submission Date for this Tender is 03-03-2021. Feeder Pillar Tenders in Dharap Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

27088890
Design , Fabrication , Installation , Testing And Commissioning Of Automatic Starter Cum Control Panel With 1 Incoming And 3 No . Outgoing Feeders Along With Auto Starter Panels For 3 No . Pumping Units Along With Cables And Other Allied Electromecha
Open Tender
Indian
Jammu And Kashmir
Dharap
03-03-2021

Tender Details

Design , Fabrication , Installation , Testing And Commissioning Of Automatic Starter Cum Control Panel With 1 Incoming And 3 No . Outgoing Feeders Along With Auto Starter Panels For 3 No . Pumping Units Along With Cables And Other Allied Electromechanical

Key Value

Document Fees
INR 200 /-
EMD
INR 9500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: design, fabrication, installation, testing & commissioning of automatic starter cum control panel with 1 incoming and 3 no. outgoing feeders alongwithautostarter panels for 3 no. pumping units along with cables and other allied electromechanical works/equipments at LIS Dharap.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Designing, fabrication, installation, testing and commissioning of LT control panel 415 volts, AC-3Phase, 50 Hz. for unit I and III (each motor of 50 HP) and unit II of 40HP at LISDharap. The panel should be dust and vermin proof fabricated out of minimum 16 SWG CR Sheet supported on M.S. angle of suitable size and provision for fixing it on the wall / floor with the help of anchoring bolts/PVC grouting. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features:\nM.C.C.B.: The panel should be fitted with a three pole M.C.C.B. of 200 Amps capacity, 1 No. volt meter, 1No. volt selector switch, 1 No. ammeter, a set of CT set, ampere selector switch and a set of RYB indicators at incoming side. \nOUTGOING No 1: The panel should be fitted with a 50 HP fully automatic star delta starter comprises of 1 no. 125A MCCB TP, 3 Nos. air break contactor (2 Nos. 65A for main and delta supply and 50A 1 No. for star operation), 1 no. ampere meter (0-100A) along with CT set and ASS ,1 No. timer for change over the supply of motor from star to delta, 2 No. push buttons for start and stop operation of motor with 2 No. indicators,1 No. MCB 6A for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables to complete the star delta circuit of outgoing supply.\nOUTGOING No 2: The panel should be fitted with a 50 HP fully automatic star delta starter comprises of 1 no. 125A MCCB TP, 2 Nos. air break contactor (2 Nos. 65A for main and delta supply and 50A 1 No. for star operation), 1 no. ampere meter (0-100A) along with CT set and ASS, 1 No. timer for change over the supply of motor from star to delta, 2 No. push buttons for start and stop operation of motor with 2 no. indicators, 1 No. MCB 6A for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables to complete the star delta circuit of outgoing supply. \nOUTGOING No 3: The panel should be fitted with a 40 HP fully automatic star delta starter comprises of 1 no. 125A MCCB TP, 2 Nos. air break contactor (2 Nos. 65A for main and delta supply and 50A 1 No. for star operation), 1 no. ampere meter (0-100A) along with CT set and ASS, 1 No. timer for change over the supply of motor from star to delta, 2 No. push buttons for start and stop operation of motor with 2 no. indicators, 1 No. MCB 6A for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables to complete the star delta circuit of outgoing supply.\nProtections device / fault analyzer: 3 Nos. protections devices / fault analyzers shall be fitted with in the panel with each starter having capability to:\nA. Protect the motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings:\nI. Voltage related fault: Single phasing, reverse phase, under voltage, over voltage, unbalance voltage.\nII. Current related fault: Over load, Under load (dry running), unbalance load, earthleakage, short circuiting Short circuit\nB. Display line current of R, Y , B Phase and also line voltage of RY, YB and BR phase.\nBimetal over load relay suitable for 50 HP motor should be fitted with each starter as an extra protection to protect the motor in case with each starter as an extra protection to protect the motor in case of failure of fault analyzer. In addition to this all the starters should be connected with incomer M.C.C.B with bus bar/flexible copper cable arrangement of adequate current carrying capacity. All other components i.e.,meters, indicators, push buttons, protection relays, operating coils of contactors etc. should be connected with flexible copper cable to complete the circuit for operating the motors. All the internal wiring should be neat and clean.\nProviding, carriage, laying and fitting of 70 sq. mm multi strand copper cable or equivalent for giving connections from main switch to control panel in three equal leads of 9mtrapprox each and 16 sq mm cable from control panel to the 3 no. motors - 90 mtrapprox with respective number of leads and making cable ends duly thimbled with copper thimbles. The cables should be laid in PVC conduits,bends of appropriate size duly clamped on wall/floor as per site suitability. \nThe complete job includes cost of panel /material/ labour, commissioning of panel and fixing requisite electrical connections, testing it and calibration of protection relays.\nMAKE OF MCCB- L&T,C&S,Havells,Schneider, ISI eq.\nMAKE OF contactor- L&T,C&S,Havells,Schneider, ISI eq.\nMake of cable: Havells, Gloster, Polycab or ISI Equivalent\n 1 Job
2 2 Dismantling of cable connections from LT terminals and from 100 KVA transformer and removing the 4 nos. burnt cables from transformer to LT terminals after getting the HT supply disconnected. Providing and installation of one no. LT Fuse link set consisting of minimum 40 mm MS angle, MS flat, drilling holes aluminum bus bars/L clamps, D type shackle insulators , nut bolts, fuse wire, drilling holes Clamps and fixing. Job also includes proper erection of MS angle frame either to be fixed on pole or properly embedded on ground with PCC. P/Fitting of 50sq. mm copper cable 12 mtrapprox or equivalent after stripping the cable ends, P/F thimble by crimping tool and giving connections to transformer and LT fuse link set. Fitting of the aluminium service cable to the LT junction after cutting & stripping the cable ends. The job includes cost of material, thimbles, insulators, bus bars, supporting angle arms, nut bolts, washers, clamps, insulation tape, , labour, transportation charges etc. 1 Job
3 3 Providing and fitting of electrical wiring at LIS Karnailachak by way of point wiring for three no. light points and two no. flood lights with 1/1.5 sq mm or equivalent copper cable for light / fan points / socket points inside and outside pump room building in casing / caping or surface conduit. The job also includes providing and fitting of switch board, switches, sockets, holders, back sheets, LED bulbs and other fittings required for the purpose. Providing and fitting bulb holder-03 no., switches, sockets, LED bulbs-03 no., switch board-1 no., led flood light 30 watt-02 no. standard make along with support stand for safety of workers. The job includes providing and laying of 04 sq. mm multistrand copper cable(neutral)-10 mtr approx. from transformer to main switch board and providing and fitting of 16 ampere SPN-01 no. Job includes fastening of cables/conduits by using wooden/plastic gutties/gang boxes, screws, clamps, drilling holes in the walls for crossing of the cable and other works required for execution of the job. The job includes cost of all sort of material, hire charges of tools and tackles required for the job including labour and carriage charges. 1 Job