State Plan 2020- Repair Of Pump Set State Plan 2020- Repair And Overhauling Of 30 Hp Centrifugal Pump Set At Kallamala Pump House
Tender Value
Ref. Documents
Estimated cost
Bid Submission
27 Feb 2021
0 days left
EMD
5500
Bank guarantee accepted
Document Fee
560
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Vatakara → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
State Plan 2020- Repair Of Pump Set State Plan 2020- Repair And Overhauling Of 30 Hp Centrifugal Pump Set At Kallamala Pump House
BOQ
| Name of Work: State plan 2020-21- TM ARWSS to Azhiyur-Repair and Overhauling of 30 hp C/F pump set at Kallamala Pump house and Interconnection work | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Rewinding and Overhauling of 30 HP Centrifugal pump set | BI01010001010000000000000515BI0100001112 | ||
| 2 | 1.01 | Charges for disconnecting electrical connections from the motor, disconnecting valves and flanges, removing the pump set from the foundation etc.<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020<br> | BI01010001010000000000000515BI0100001113 | 1 | Nos |
| 3 | 1.02 | Carefulley loading the motor to the vehicle and conveying to workshop -<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001114 | 10 | mtr |
| 4 | 1.03 | Removing motor two side flanges and rotor, burned winding wire and insulating materials complete removing from the stator, cleaning the slots on the yoke etc.<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001115 | 1 | Nos |
| 5 | 1.04 | Supplying good quality insulated copper wire (19, 19.5 and 20 SWG), F50 insulating varneesh, fiber glass sheet and sleeve etc., <br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001116 | 10 | mtr |
| 6 | 1.05 | Labor charges for complete insulating the stator slots using fiber glass sheet, motor complete rewinding, winding insulating properly with F50 insulating varnish, new winding leads connecting etc<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001117 | 1 | Nos |
| 7 | 1.06 | Removing motor damaged 2 side bearings, supplying 2nos 6310 bearings and replacing the damaged with new, bearing seat shaft welding and machining, new bearing setting etc<br> | BI01010001010000000000000515BI0100001118 | 10 | mtr |
| 8 | 1.07 | Charges for supplying motor coupling, removing motor damaged coupling, replacing with new and setting charge<br> | BI01010001010000000000000515BI0100001119 | 1 | Nos |
| 9 | 1.08 | Charges for supplying pump bearing housing and setting charge -<br> | BI01010001010000000000000515BI0100001120 | 10 | mtr |
| 10 | 1.09 | Charges for supplying pump 2 side bearings (6310), removing and replacing damaged bearings with new<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001121 | 1 | Nos |
| 11 | 1.1 | Charges for supplying and replacing pump two side damaged SS sleeves and setting charge<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001122 | 10 | mtr |
| 12 | 1.11 | Charges for supplying and replacing two side gland rope flange and new gland rope filling with grease -<br> | BI01010001010000000000000515BI0100001123 | 1 | Nos |
| 13 | 1.12 | Charges for supplying and replacing impeller two side damaged neck ring -<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001124 | 10 | mtr |
| 14 | 1.13 | Charges for supplying foundation nuts and bolts 18nos. and replacing the damaged with new -<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001125 | 1 | Nos |
| 15 | 1.14 | Charges for supplying and replacing Four nos of damaged foot valve with new 65mm ball type ,non repairable foot valve -for both 15 HP and 30 HP (ncluding for standby pump set)- Rs 3250/Each<br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001126 | 10 | mtr |
| 16 | 1.15 | Charges for loading the pump set carefulley to the vehicle, conveying back to site and unloading, <br>Vetted estimate by electrical special officer VDA-37/20/13.10.2020 | BI01010001010000000000000515BI0100001127 | 1 | Nos |
| 17 | 1.16 | Charges for re-fitting the pump set on the foundation, re-connecting valves and flanges, re-connecting electrical connections and test run<br> | BI01010001010000000000000515BI0100001128 | 10 | mtr |
| 18 | 2 | Supply and erection of Panel board and starter, switch | BI01010001010000000000000515BI0100001129 | ||
| 19 | 2.01 | Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation,Supply, laying, testing of suitable size XLPE cables for pump set from panel board to starter and from starter to motor.Providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.And supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834-30 HP Centrifugal pump | BI01010001010000000000000515BI0100001130 | 1 | Nos |
| 20 | 2.02 | Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer and 2 Nos of suitable capacity MCCB as out going (the two MCCBs are interlocking with each other) providing suitable size Aluminium bus bar inter connect the above MCCBs and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation,Supply, laying, testing of suitable size XLPE cables for pump set from panel board to starter and from starter to motor.Providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards.And supply, erection, testing and commissioning of heavy duty APP capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS 2834-15 HP Centrifugal pump | BI01010001010000000000000515BI0100001131 | 10 | mtr |
| 21 | 2.03 | Charges for supplying 15 HP star delta starter with Single phase and dry run preventor, Over/Under Voltage Protection Realy removing damaged starter and fixing new starter, new leads connecting -<br> | BI01010001010000000000000515BI0100001132 | 1 | Nos |
| 22 | 2.04 | Charges for supplying 30HP star delta starter, with Single phase and dry run preventor, Over/Under Voltage Protection Realy and removing the damaged starter from the panel board, fixing new starter etc.<br> | BI01010001010000000000000515BI0100001133 | 10 | mtr |
| 23 | 2.05 | Supply and installation of dust and vermin proof three phase meter board fixing it on wall,making good the damages, colour washing etc as required.(Rate of Energy meter is not included in the above item) | BI01010001010000000000000515BI0100001134 | 1 | Nos |
| 24 | 2.06 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required ,100 A, TP&N<br>Data derived from item no 2.1.3 in DSR E and M 2016 | BI01010001010000000000000515BI0100001135 | 10 | mtr |
| 25 | 2.07 | Providing and fixing PVC pipes, fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per the direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 4 kgf/cm2 | BI01010001010000000000000515BI0100001136 | 1 | Nos |
| 26 | 3 | Replacing damaged Valves and pipes | BI01010001010000000000000515BI0100001137 | ||
| 27 | 3.01 | Grinding cut and weld edges of 100mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete( Data derived from the item no 100.37.5.5) | BI01010001010000000000000515BI0100001138 | 10 | mtr |
| 28 | 3.02 | Welding 80 mm (ID) MS pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For 80 mm GI pipe( Data derived from the itme no 100.37.5.4) | BI01010001010000000000000515BI0100001139 | 1 | Nos |
| 29 | 3.03 | Fabricating MS flanges of diameter 80 mm using 12 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates(. Datad derived from 100.37.5.2) | BI01010001010000000000000515BI0100001140 | 10 | mtr |
| 30 | 3.04 | Supply of 80 mm GI Pipe (DSR Rate) | BI01010001010000000000000515BI0100001141 | 1 | Nos |
| 31 | 3.05 | Hire Charge of Joint cutting machine with 2-3 blades | BI01010001010000000000000515BI0100001142 | 10 | mtr |
| 32 | 3.06 | \"Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. Class I\"Observed Data derived from item no.18.31.of DAR | BI01010001010000000000000515BI0100001143 | 1 | Nos |
| 33 | 3.07 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) | BI01010001010000000000000515BI0100001144 | 10 | mtr |
| 34 | 3.08 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete | BI01010001010000000000000515BI0100001145 | 1 | Nos |
| 35 | 3.09 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more | BI01010001010000000000000515BI0100001146 | 10 | mtr |
| 36 | 3.1 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix) | BI01010001010000000000000515BI0100001147 | 1 | Nos |
| 37 | 3.11 | 12 mm cement plaster of mix 1: 4 | BI01010001010000000000000515BI0100001148 | 10 | mtr |
| 38 | 3.12 | Water level indicator on the concrete OHSR tank using pulley,enamel paint,flexible wire and floating ball with proper scale ratio as per the direction of the departmental officers,which includes the conveyance of material,cost of material, labour charge and all other incidental charges etc | BI01010001010000000000000515BI0100001149 | 1 | Nos |
| 39 | 4 | Supply of Valve | BI01010001010000000000000515BI0100001150 | ||
| 40 | 4.01 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 80mm. | BI01010001010000000000000515BI0100001151 | 10 | mtr |
| 41 | 4.02 | Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.6, Size 80mm. | BI01010001010000000000000515BI0100001152 | 1 | Nos |
| 42 | 5 | Clearing, conveying and disposing unserviceable scrap items | BI01010001010000000000000515BI0100001153 | ||
| 43 | 5.01 | Clearing the pump house and its premises for conveying dismantled pump, valve and and pipe specials from pump house using manually or mechanical means to section store. Properly stacking this material to section store including loading ,unloading transportation,consumption of fuel, labour material and all other incidental charges if any as per the direction of the departmental officers concerned | BI01010001010000000000000515BI0100001154 | 1 | Nos |
AI Tender Summary
Tender Timeline
Feb 22, 2021
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 27, 2021
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 03, 2021
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender