| Name of Work:Construction of Tribal Rest House at Salbari, Dist: Baksa | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (a) In ordinary soil | Item 1 | 324.636 | cum |
| 2 | 2 | Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered) (b) Above 1.5 m upto 3.00 m depth | Item 2 | 254.386 | cum |
| 3 | 3 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | Item 3 | 442.37 | cum |
| 4 | 4 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume | Item 4 | 21.9608 | cum |
| 5 | 5 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering,complete. (a).Brick on flat soling. | Item 5 | 2550.88 | sqm |
| 6 | 6 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc.complete. c) 50mm thick | Item 6 | 531.36 | sqm |
| 7 | 7 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | Item 7 | 61.46 | sqm |
| 8 | 8 | Providing and laying plain/reinforced cement croncrete works\n using cement, coarse sand & 20mm down graded stone aggregate \n with cost of necessary form work including dewatering if necessary,\n ...................work complete as directed. I) Using mixture machine (A) In sub - structure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser (b) M20 or Prop. 1:11/2:3 | Item 8 | 59.06 | cum |
| 9 | 9 | B) In super structure up to 1st floor level i) Vertical members like column, pillars, post, struts etc N) Without using admixture, plasticiser (b) M20 or Prop. 1:11/2:3 | Item 9 | 20.536 | cum |
| 10 | 10 | ii) Horizontal members like beam, lintel, girder bressumer etc. N) Without using admixture, plasticiser (b) M20 or Prop. 1:11/2:3 | Item 10 | 17.562 | cum |
| 11 | 11 | iii) Suspended floor (Slab, balcony, staircase etc) N) Without using admixture, plasticiser (b) M20 or Prop. 1:11/2:3 | Item 11 | 1.176 | cum |
| 12 | 12 | Brickwork with Plastering Brick work in cement morter with 1st class brick including cement mortar plastering, racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. (III) One side plastering with 10mm thick i) Using plastering of cement mortar prop. 1:4 a) Brick work in cement morter proportion 1:5 | Item 12 | 24.4635 | cum |
| 13 | 13 | Brick work in cement morter with 1st class brick including cement mortar plastering, racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level. | Item 13 | 22.03 | cum |
| 14 | 14 | 112mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) B) Both side plastering I) With fair side 10mm thick and rough side 15mm thickplastering i) In prop. 1:4 a) Brick work in cement morter proportion 1:4 | Item 14 | 345.014 | sqm |
| 15 | 15 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (a) With sal wood | Item 15 | 0.3804 | cum |
| 16 | 16 | Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels. | Item 16 | 20 | rm |
| 17 | 17 | Providing, fitting and fixing PVC Door shutters of 37mm (single panel seamless finish) of Syntex make, at all levels made of extruded sections in the configuration of 'A'.The overall dimension is 37mm x 90mm, with usual process variation having a wall thickness of 2mm with a variation of +0.03mm provided with all plastic reinforcement to avoid rusting. The shutter frame is mitred and joined at the corners by means of stainless steel screws.The corners of the shutter frame are being reinforced by polymeric reinforcement of the size 125mm x 250mm and the lock rail is reinforced by 45 x18 x255 size reinforcement. | Item 17 | 6.72 | sqm |
| 18 | 18 | Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm), 300x10 mm Tower bolts-2nos,150 mm Door handle-2nos, 300x16mm- Sliding Door bolts-2nos and Door stopper with rubber stopper-1nos with necessay screws complete as directed I) Using Electro Coloured Iron fittings A).With Teak wood / Sissu wood. (i) 40 mm thick . | Item 18 | 27.3 | sqm |
| 19 | 19 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (i) TMT Corrosion resistant steel (CRS) reiforcement bar | Item 19 | 195.265 | Qtl |
| 20 | 20 | Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. I . Plain grill (c) Fixed to Brickwork/P.C.C/R.C.C. | Item 20 | 983.78 | Kg |
| 21 | 21 | Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998 | Item 21 | 58.256 | Qtl |
| 22 | 22 | 18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. | Item 22 | 506.88 | sqm |
| 23 | 23 | B) ON WALLS Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department). ii) Of size150mmx605mm and above (Strips) | Item 23 | 50.35 | sqm |
| 24 | 24 | ANTISKID TILES Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (A) CERAMIC i)Normal range (Sizes 300 mm x 300mm and above) (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate | Item 24 | 35.28 | sqm |
| 25 | 25 | B) ON WALLS Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). | Item 25 | 57.29 | sqm |
| 26 | 26 | Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (i)6mm clear glass | Item 26 | 40.58 | sqm |
| 27 | 27 | Providing and fixing Mineral Fiber Acoustic Ceiling Tiles in 600mm x 600mm of 13mm/15mm thickness to be placed in E- Grid Suspended Ceiling Grid 2430 System consisting of Main Runner 3600 mm long, Cross Tee 1200mm/600mm long and Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. Main Runner shall be ..........................................long to finally form a grid of 600mm x 600mm.E-Grid of module size 600mm x 600mm shall be supported by 4/6 mm dia G.I. wire from purlins/soffit Mineral Fiber Acoustic Ceiling Tiles of Everest Industries Limited should be placed in the E-Grid module to form a False Ceiling including the cuttings complete as directed. | Item 27 | 506.88 | sqm |
| 28 | 28 | Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. \n | Item 28 | 17.28 | sqm |
| 29 | 29 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement. (iv) 0.45 mm thick | Item 29 | 36.08 | sqm |
| 30 | 30 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement. (iii) 0.50 mm thick | Item 30 | 634.32 | sqm |
| 31 | 31 | Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete.\nTATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (iv) 0.45 mm thick | Item 31 | 37.8 | rm |
| 32 | 32 | Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete. | Item 32 | 154.8 | rm |
| 33 | 33 | Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. | Item 33 | 92.82 | sqm |
| 34 | 34 | Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. | Item 34 | 400 | RM |
| 35 | 35 | Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. b) 100mm thick slab | Item 35 | 200 | sqm |
| 36 | 36 | Red oxide plaster skirting with top layer of 5 mm thick cement plaster of cement mix using 3.5 kg. red oxide of iron per 50kg of cement in proportion 1:3 (1 cement: 3 coarse sand) finished with a floating coat of cement red oxide mix of same proportion. (a) 15 mm thick with under layer of 10 mm thick cement plaster. | Item 36 | 92.52 | sqm |
| 37 | 37 | Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed. | Item 37 | 1400.61 | sqm |
| 38 | 38 | Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick | Item 38 | 61.92 | sqm |
| 39 | 39 | (n) Distempering two coats with oil bound distemper of approved brand and manufacture and of required shade on new wall surface to give an even shade, over and including a priming coat with alkali resistant primer of approved brand and manufacture after throughly brooming the surface free from mortar dropings and other foreign matter and also including preparing the surface even and sand papered smooth. (i).Priming coat with alkali resistant primer | Item 39 | 1554.65 | sqm |
| 40 | 40 | (ii). Top coat | Item 40 | 1554.65 | sqm |
| 41 | 41 | a) Removing dry or oil bound distemper by washing and scraping and sand papering the wall surface smooth including necessary repairs to scratches complete. | Item 41 | 61.92 | sqm |
| 42 | 42 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | Item 42 | 61.92 | sqm |
| 43 | 43 | Finishing old/ new wall with water proofing weather coat smooth anti-fungal exterior painting of Apex brand of Asian Paints and of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats) | Item 43 | 1616.57 | sqm |
| 44 | 44 | Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts). | Item 44 | 10 | Qtl |
| 45 | 45 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201 (I)By Manual Means (A)In area of non-thorny jungle | Item 45 | 0.2 | Hac |
| 46 | 46 | Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11 | Item 46 | 607.5 | sqm |
| 47 | 47 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (ii)From Govt. land | Item 47 | 1215 | cum |
| 48 | 48 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii)For Grading II Material | Item 48 | 205.31 | cum |
| 49 | 49 | WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. | Item 49 | 123.19 | cum |
| 50 | 50 | Sand Filling in Foundation Trenches as per Drawing & Technical Specification | Item 50 | 123.19 | cum |
| 51 | 51 | Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. | Item 51 | 45 | cum |
| 52 | 52 | Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage. | Item 52 | 1125 | sqm |
| 53 | 53 | Providing polished tiles of approved quality, size, shape of specified thickness on pavers over a base of 100mm compacted sand gravel including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (A) SUN ROCK HIGH CTS Tiles (Pavers) (c) Silicon (Pavers) 40 mm thick | Item 53 | 1800 | sqm |
| 54 | 54 | Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) A) Parryware make a) White (i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover) | Item 54 | 2 | Each |
| 55 | 55 | Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.) B) Hindware make a) White | Item 55 | 2 | Each |
| 56 | 56 | Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified. | Item 56 | 2 | each |
| 57 | 57 | Providing fitting and fixing Glass Shelf complete as directed and specified. Glass shelf with C.P. guard rail (ii) Sona make (Cat. No.TR-0701) | Item 57 | 4 | Each |
| 58 | 58 | Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (b) Sona Make (i) Soap dish light (Cat.No.TR-0661) | Item 58 | 4 | each |
| 59 | 59 | Providing, fitting and fixing CP towel rail complete as directed and specified. (a) Jaquar make (iv) Queen's (450mm long) (Cat.No.AQN-7711A) | Item 59 | 8 | each |
| 60 | 60 | Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified. | Item 60 | 2 | each |
| 61 | 61 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia. | Item 61 | 150 | each |
| 62 | 62 | (ii) 110mm dia. | Item 62 | 110 | each |
| 63 | 63 | (iv) 75mm dia. | Item 63 | 50 | each |
| 64 | 64 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm dia. | Item 64 | 50 | each |
| 65 | 65 | (ii) 110mm dia. | Item 65 | 100 | each |
| 66 | 66 | (iv) 75mm dia. | Item 66 | 50 | each |
| 67 | 67 | Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia. | Item 67 | 28 | each |
| 68 | 68 | (ii) 110mm dia. | Item 68 | 16 | each |
| 69 | 69 | (iv) 75 mm dia. | Item 69 | 18 | each |
| 70 | 70 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm dia. | Item 70 | 20 | each |
| 71 | 71 | (ii) 110mm dia. | Item 71 | 21 | each |
| 72 | 72 | (iv) 75 mm dia. | Item 72 | 19 | each |
| 73 | 73 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia. | Item 73 | 33 | each |
| 74 | 74 | (i) 160mm dia | Item 74 | 28 | each |
| 75 | 75 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia. | Item 75 | 8 | each |
| 76 | 76 | (i) 160mm dia | Item 76 | 10 | each |
| 77 | 77 | Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia. | Item 77 | 14 | each |
| 78 | 78 | (ii) 110mm dia. | Item 78 | 12 | each |
| 79 | 79 | (iv) 75 mm dia. | Item 79 | 8 | each |
| 80 | 80 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm dia. | Item 80 | 14 | each |
| 81 | 81 | (ii) 110mm dia. | Item 81 | 12 | each |
| 82 | 82 | (iv) 75 mm dia. | Item 82 | 8 | each |
| 83 | 83 | Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia. | Item 83 | 12 | each |
| 84 | 84 | (ii) 110mm dia. | Item 84 | 8 | each |
| 85 | 85 | (iv) 75 mm dia. | Item 85 | 8 | each |
| 86 | 86 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm dia. | Item 86 | 12 | each |
| 87 | 87 | (ii) 110mm dia. | Item 87 | 8 | each |
| 88 | 88 | (iv) 75 mm dia. | Item 88 | 8 | each |
| 89 | 89 | Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia. | Item 89 | 15 | each |
| 90 | 90 | (iv) 75 mm dia. | Item 90 | 15 | each |
| 91 | 91 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia. | Item 91 | 15 | each |
| 92 | 92 | (iv) 75 mm dia. | Item 92 | 12 | each |
| 93 | 93 | Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm x110mm | Item 93 | 18 | each |
| 94 | 94 | (ii) 75 mm x 75mm | Item 94 | 18 | each |
| 95 | 95 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm x110mm | Item 95 | 8 | each |
| 96 | 96 | (ii) 75 mm x 75mm | Item 96 | 8 | each |
| 97 | 97 | Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110 mm dia | Item 97 | 12 | each |
| 98 | 98 | (iii) 75 mm dia | Item 98 | 8 | each |
| 99 | 99 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110 mm dia | Item 99 | 12 | each |
| 100 | 100 | (iii) 75 mm dia | Item 100 | 6 | each |
| 101 | 101 | Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iv) 110 mm x 75mm | Item 101 | 8 | each |
| 102 | 102 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 110 mm x 75mm | Item 102 | 8 | each |
| 103 | 103 | Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iii) 110 mm x 75mm | Item 103 | 12 | each |
| 104 | 104 | b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iii) 110 mm x 75mm | Item 104 | 10 | each |
| 105 | 105 | Supplying fiting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. (b) 110 mm | Item 105 | 24 | each |
| 106 | 106 | (c) 75 mm | Item 106 | 30 | each |
| 107 | 107 | Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make | Item 107 | 28 | each |
| 108 | 108 | Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. (b) 75mm dia | Item 108 | 12 | each |
| 109 | 109 | Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified. | Item 109 | 2 | each |
| 110 | 110 | Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. | Item 110 | 5 | each |
| 111 | 111 | Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. | Item 111 | 2 | each |
| 112 | 112 | Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. (A) Exposed or in trenches SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40) Exposed or in trenches b) 40 mm dia | Item 112 | 150 | RM |
| 113 | 113 | (B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure. SUPREME/ PRINCE / SFMC / FUSION BAND or other equvalent approved brand (High presure pipe Sch-40) 32 mm dia | Item 113 | 100 | RM |
| 114 | 114 | Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) Jaquare make (a)Continental /Clarion (i)Standard | Item 114 | 60 | Each |
| 115 | 115 | Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar (a) Continental / Clarion (i)15mm dia Male / Female (long thread) | Item 115 | 2 | Each |
| 116 | 116 | Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) Essco brand a) Sink cock with \"U\" shape swinging casted spout | Item 116 | 4 | Each |
| 117 | 117 | Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40 mm dia. | Item 117 | 4 | Each |
| 118 | 118 | c) 25 mm dia. | Item 118 | 6 | Each |
| 119 | 119 | d) 2O mm dia. | Item 119 | 6 | Each |
| 120 | 120 | Supplying fitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia (Heavy type) | Item 120 | 2 | Each |
| 121 | 121 | Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost). | Item 121 | 100 | RM |
| 122 | 122 | Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. vi) Bore hole of 200mm diameter | Item 122 | 100 | RM |
| 123 | 123 | Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. PVC PIPE SUPREME /PRINCE / FUSION /SFMC Brand vii) 160mm diameter | Item 123 | 100 | Rm |
| 124 | 124 | Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. A) G.I. pipe a) TATA / SAIL (Medium)socket should be welded to the pipes. iv) 50mm diameter | Item 124 | 80 | Rm |
| 125 | 125 | Supplying fitting and fixing brass Tez filter 2.00 metre long. | Item 125 | 60 | Each |
| 126 | 126 | Supplying fitting and fixing check valve (non return valve) including thread to pipes. iv) 50mm diameter | Item 126 | 4 | Each |
| 127 | 127 | Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained | Item 127 | 1 | Job |
| 128 | 128 | Flushing, clearing, washing and watering of the tube well | Item 128 | 1 | Job |
| 129 | 129 | Supplying and placing ferrocement water tanks of circular/rectengular shape over stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for inlet and outlet pipes complete as directed.(Stagging should be measured and paid separately). 2000 Lt capacity water tank | Item 129 | 1 | Each |
| 130 | 130 | Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration rate per hour of DOLPHIN make with all necessary fittings such as valve,bib cock,pipe connection etc.with a free maintanance period of six monthhs. (A) With Zoloto fittings (II) 2000 liters capacity (a) 4 mm thick Vessel | Item 130 | 1 | Each |
| 131 | 131 | Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete. Short point up to 3.00 metre. length. | Item 131 | 60 | Each |
| 132 | 132 | Medium point up to 6.00 metre. Length. | Item 132 | 50 | Each |
| 133 | 133 | Long point up to 10.00 metre. Length. | Item 133 | 50 | Each |
| 134 | 134 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Short point up to 3.00 metre. length. | Item 134 | 60 | Each |
| 135 | 135 | Medium point up to 6.00 metre. Length. | Item 135 | 48 | Each |
| 136 | 136 | Long point up to 10.00 metre. Length. | Item 136 | 36 | Each |
| 137 | 137 | Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan. | Item 137 | 24 | Each |
| 138 | 138 | Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 2 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 138 | 570 | Metre. |
| 139 | 139 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 139 | 340 | Metre. |
| 140 | 140 | With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 140 | 180 | Metre. |
| 141 | 141 | With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 141 | 120 | Metre. |
| 142 | 142 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 4 sq. mm. + earth continuity with 2x2.5 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 142 | 120 | Metre. |
| 143 | 143 | With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. \n | Item 143 | 100 | Metre. |
| 144 | 144 | With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | Item 144 | 80 | Metre. |
| 145 | 145 | Supplying and fixing of batten holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) including connection as approved by the Deptt.)as required Without Lamp | Item 145 | 7 | Each |
| 146 | 146 | Fitting and fixing of brackets on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories such as GI/ MS switch board (ISI marked) with phenolic laminated sheet cover including connection as approved by the Deptt.)as required complete. | Item 146 | 8 | Each |
| 147 | 147 | Supplying and fixing of Philips 32081/ 31 TYPE flush type circular ceiling fittings (or equivalent as approved by the Deptt.) complete with Shade, holder, back plate and LAMP holder, 11 Watt LED lamp including connection as required. | Item 147 | 11 | Each |
| 148 | 148 | Supplying,installation,testing and Commission of the following LED lamp as directed by the department Philips LED bulbs non-dimmable 7/9 W or equivalent as approved by the Deptt. | Item 148 | 34 | Each |
| 149 | 149 | Supplying with fitting fixing of surface & wall mounted LED luminaries complete with all accessories including driver directly on wall / ceiling including connection with 1.5 sq mm P.V.C. insulated S.C.copper conductor as required and as directed by the department. 18 Watt 4 ft LED Batten luminaries ( Bright line PHILLIPS make) | Item 149 | 45 | Each |
| 150 | 150 | Supplying and fixing of Call bell ( Buzzer ) including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required. | Item 150 | 2 | Each |
| 151 | 151 | Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make). Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make | Item 151 | 30 | Each |
| 152 | 152 | Supplying fitting and fixing of ceiling fan regulator including connections etc. complete as required. Electronic Type type | Item 152 | 30 | Each |
| 153 | 153 | Supplying,installation,testing and Commission of the following indoor surface Mounted LED Luminaires complete with all accessories such as driver etc. and necessary connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department Philips lighting luminaire 15 w Green LED Surface Mounted Model DN170C LED10S-6500 PSU WH /DN170C LED10S-3000 PSU WH/ DN170C LED10S-4000 PSU WH or equivalent as approved by the Deptt. | Item 153 | 6 | Each |
| 154 | 154 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 8 way TPN (8+24) double door | Item 154 | 1 | Each |
| 155 | 155 | Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB \n(Schneider, legrand, Siemens, Indo Asian make) 63A | Item 155 | 2 | Each |
| 156 | 156 | 100A | Item 156 | 1 | Each |
| 157 | 157 | Supplying including fitting fixing of following A.C. Wall fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. ORIENT make or equivalent Usha make Air Circulator wall fan 450 mm sweep Turbo force | Item 157 | 2 | Each |
| 158 | 158 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCCB enclosure of the following rating MCCB fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, HPL, V-Guard or equivalent make as approved by the Deptt.) for 100A 3P/4P MCCB | Item 158 | 1 | Each |
| 159 | 159 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 8 way SPN double door | Item 159 | 2 | Each |
| 160 | 160 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series\n(Schneider MG, legrand, Hager make) 6 to 32A | Item 160 | 24 | Each |
| 161 | 161 | Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 0.85M X 1.20MX 0.40M made of 16 SWG/1.66 mm thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of Enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 125/160A 4pole MCCB or Switch Fuse Unit as incomer and provision for 4nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items: 1. 20mm X 3mm 4 strip copper Bus-Bar 1.0 M length each 2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no 3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no 4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no 5. Voltmeter & Ammeter Selector Switch - 2 no 6. 2 A Slide fuse unit - 3nos (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) | Item 161 | 1 | Each |
| 162 | 162 | Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt. | Item 162 | 2 | Each |
| 163 | 163 | Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. | Item 163 | 10 | Each |
| 164 | 164 | Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | Item 164 | 20.41 | Metre. |
| 165 | 165 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 2 Core A2XWaY A2XFaY 4.00 Sq.mm 2 Core armoured U.G. cable | Item 165 | 24 | Mtr |
| 166 | 166 | Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET, Single Phase with steel cable rope and submersible cable complete as directed and specified by the deptt. | Item 166 | 1 | Each |
| 167 | 167 | Supplying fitting and fixing including necessary connection as approved by the Deptt.)of Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) of following type and capacity as specified and directed by the Department. ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) | Item 167 | 1 | Each |
| 168 | 168 | GST | Item 168 | 1 | Each |
| 169 | 169 | Agency Charge | Item 169 | 1 | Each |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy