}

Request For Proposal (Rfp) For Fixation Of Rates For Different Items Of The Piped Water Supply Schemes To Be Executed Under Jal Jeevan Mission Assam For Dima Hasao Zone, Dima Hasao-Assam

Public Health Engineering Department has published Request For Proposal (Rfp) For Fixation Of Rates For Different Items Of The Piped Water Supply Schemes To Be Executed Under Jal Jeevan Mission Assam For Dima Hasao Zone. Submission Date for this Tender is 03-03-2021. Pipe and Tube Fittings Tenders in Dima Hasao Assam. Bidders can get complete Tender details and download the document.




Tender Notice

27020049
Request For Proposal (Rfp) For Fixation Of Rates For Different Items Of The Piped Water Supply Schemes To Be Executed Under Jal Jeevan Mission Assam For Dima Hasao Zone
Tender
Indian
Assam
Dima Hasao
03-03-2021

Tender Details

Request For Proposal ( Rfp ) For Fixation Of Rates For Different Items Of The Piped Water Supply Schemes To Be Executed Under Jal Jeevan Mission Assam For Dima Hasao Zone - 2 Installation , Testing And Commissioning Dtw With Dth Boring N Na ) Items Required For Developing The Dtw 3 B ) Cost For Drilling In Overburden Soil In Dth. 4 C ) Cost For Drilling In Rocky Strata In Dth 5 Construction Of Rcc Intake Weir For Various Pwss 6 Supplying, Fitting, Fixing, Testing And Commissioning Of Raw Water Gravity Main ( Gi Pipes ) Of Different Diameter N Na ) 150 Mm 7 B ) 100 Mm 8 C ) 80 Mm 9 D ) 65 Mm 10 E ) 50 Mm 11 F ) 40 Mm 12 Supplying, Fitting, Fixing, Testing And Commissioning Of Raw Water Pumping Main ( Gi Pipe ) Of Different Diameter N Na ) 150 Mm 13 B ) 100 Mm 14 C ) 80 Mm 15 D ) 65 Mm 16 E ) 50 Mm 17 F ) 40 Mm 18 Construction Of Rcc Slow Sand Filter Of 4.00 Sqm Size For Various Pwss 19 Construction Of Rcc Slow Sand Filter Of 6.25 Sqm Size For Various Pwss 20 For Rapid Sand Filter ( 4 Sqm ) With Internal Connection Between T.P And U.G.R 21 For Rapid Sand Filter ( 6 Sqm ) With Internal Connection Between T.P And U.G.R 22 Construction Of Overground Rcc Clear Water Reservoir Of Different Capacities N Na ) 15000 L 23 B ) 20000 L 24 C ) 50000 L 25 D ) 60000 L 26 E ) 80000 L 27 F ) 100000 L 28 Construction Of Underground Rcc Reservoir Of Different Capacities N Na ) 70, 000 Lit. ( 5.00M X 4.80M X 3.5M ) 29 B ) 70, 000 Lit. ( 6.00M X 4.00M X 3.5M ) 30 C ) 60, 000 Lit. ( 5.00M X 4.00M X 3.5M ) 31 D ) 60, 000 Lit. ( 5.30M X 3.75M X 3.5M ) 32 E ) 50, 000 Lit. ( 5.00M X 4.00M X 3.0M ) 33 F ) 50, 000 Lit. ( 4.50M X 4.50M X 3.0M ) 34 G ) 40, 000 Lit. ( 5.00M X 3.20M X 3.0M ) 35 H ) 40, 000 Lit. ( 4.00M X 4.00M X 3.0M ) 36 I ) 30, 000 Lit. ( 4.00M X 3.00M X 3.0M ) 37 J ) 20, 000 Lit. ( 3.20M X 3.20M X 2.45M ) 38 K ) 15, 000 Lit. ( 3.20M X 2.50M X 2.45M ) 39 Supply, Fitting, Fixing Of Submersible Pump With Accessories N Na ) 1 Hp Single Phase ( Head Loss 32 M, Depth Of Column Pipe=80 M ) 40 B ) 1 Hp Single Phase ( Head Loss 43 M, Depth Of Column Pipe=90 M ) 41 C ) 1 Hp Single Phase ( Head Loss 55 M, Depth Of Column Pipe=100 M ) 42 D ) 2 Hp Single Phase ( Head Loss 32 M, Depth Of Column Pipe=80 M ) 43 E ) 2 Hp Single Phase ( Head Loss 43 M, Depth Of Column Pipe=90 M ) 44 F ) 2 Hp Single Phase ( Head Loss 55 M, Depth Of Column Pipe=100 M ) 45 G ) 2 Hp Single Phase ( Head Loss 32 M, Depth Of Column Pipe=80 M ) 46 H ) 3 Hp 3-Phase ( Head Loss 43 M, Depth Of Column Pipe=90 M ) 47 I ) 3 Hp 3-Phase ( Head Loss 55 M, Depth Of Column Pipe=100 M ) 48 G ) 3 Hp 3-Phase ( Head Loss 32 M, Depth Of Column Pipe=80 M ) 49 H ) 5 Hp 3-Phase ( Head Loss 43 M, Depth Of Column Pipe=90 M ) 50 I ) 5 Hp 3-Phase ( Head Loss 55 M, Depth Of Column Pipe=100 M ) 51 J ) 3 Hp 3-Phase ( Head Loss 32 M, Depth Of Column Pipe=80 M ) 52 K ) 5 Hp 3-Phase ( Head Loss 43 M, Depth Of Column Pipe=90 M ) 53 L ) 5 Hp 3-Phase ( Head Loss 55 M, Depth Of Column Pipe=100 M ) 54 M ) 5 Hp 3-Phase ( Head Loss 32 M, Depth Of Column Pipe=80 M ) 55 N ) 5 Hp 3-Phase ( Head Loss 43 M, Depth Of Column Pipe=90 M ) 56 O ) 7.5 Hp 3-Phase ( Head Loss 55 M, Depth Of Column Pipe=100 M ) 57 P ) 5 Hp 3-Phase ( Head Loss 32 M, Depth Of Column Pipe=80 M ) 58 K ) 5 Hp 3-Phase ( Head Loss 32 M, Depth Of Column Pipe=300 M ) 59 R ) 7.5 Hp 3-Phase ( Head Loss 43 M, Depth Of Column Pipe=90 M ) 60 S ) 7.5 Hp 3-Phase ( Head Loss 55 M, Depth Of Column Pipe=100 M ) 61 T ) 7.5 Hp 3-Phase ( Head Loss 55 M, Depth Of Column Pipe=300 M ) 62 Supply, Fitting, Fixing Of Electric Driven Clear Water Centrifugal Pump Set N Na ) 1 Hp Single Phase ( Head Loss 30 M ) 63 B ) 2 Hp Single Phase ( Head Loss 30 M ) 64 C ) 2 Hp Single Phase ( Head Loss 30 M ) 65 D ) 3 Hp 3-Phase ( Head Loss 30 M ) 66 E ) 3 Hp 3-Phase ( Head Loss 30 M ) 67 F ) 5 Hp 3-Phase ( Head Loss 30 M ) 68 G ) 5 Hp 3-Phase ( Head Loss 30 M ) 69 H ) 7.5 Hp 3-Phase ( Head Loss 30 M ) 70 I ) 10 Hp 3-Phase ( Head Loss 30 M ) 71 J ) 12.5 Hp 3-Phase ( Head Loss 30 M ) 72 Construction Of Pump House Of Size 3.00M X 4.00M X 3.30M 73 Supplying, Fitting, Fixing, Testing And Commissioning Of Clear Water Pumping Main ( Gi Pipe ) Of Different Diameter N Na ) 150 Mm 74 B ) 100 Mm 75 C ) 80 Mm 76 D ) 65 Mm 77 E ) 50 Mm 78 F ) 40 Mm 79 Supplying, Fitting, Fixing, Testing & Commissioning Of Distribution Network With Hdpe Pipe Of Different Diameter N Na ) 160 Mm 80 B ) 140 Mm 81 C ) 125 Mm 82 D ) 110 Mm 83 E ) 90 Mm 84 F ) 75 Mm 85 G ) 63 Mm 86 H ) 50 Mm 87 Construction Of Rcc Supporting Pillar For Distribution Network, Raw Water Gravity Main, Raw Water Pumping Main Of Different Heights From Ground Level N Na ) 0.5 M 88 B ) 0.8 M 89 C ) 1.0 M 90 D ) 1.2 M 91 Providing, Fitting, Fixing 10, 000 Litres ( I.E. 5000X2 ) Hdpe Tank For Upto 30 Nos. Fhtc 92 Installation Of Solar Pumping System Of N Na ) 5 Hp 93 B ) 7.5 Hp 94 Installation Of Solar Pumping System Of N Na ) 10 Hp 95 B ) 15 Hp 96 C ) 20 Hp 97 Supplying, Installation, Testing And Commissioning Of Dg Sets Of Different Capacities N Na ) 5 Kva 98 B ) 7.5 Kva 99 C ) 10 Kva 100 D ) 12.5 Kva 101 E ) 15 Kva 102 F ) 20 Kva 103 Providing Fhtc From The Distribution Network 104 Construction Of Valve Chamber Including Sluice Valve For Hdpe Pipe N Na ) 80 Mm Dia S / V 105 B ) 100 Mm Dia S / V 106 C ) 125 Mm Dia S / V 107 D ) 150 Mm Dia S / V 108 Supplying, Installation, Testing Of Electrically Operated Chemical Dosing Pump 109 Construction Of Boundary Wall For Treatment Plant 110 Supplying, Fitting, Fixing Of Bulk Flow Meter Of N Na ) Bfm 80 111 B ) Bfm 100 112 C ) Bfm 125 113 D ) Bfm 150 114 E ) Bfm 200 115 Conducting Survey Work For Laying Raw Water Gravity / Pumping Main And Distribution System Under Different Water Supply Schemes 116 Providing Mechanical Tool Box 117 Providing Electrical Tool Box 118 Restoration Of Paver Block Road Of The Distribution Network

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail