| 1 | 1 | SCHEDULE ‘A’ SECTION-I\n | | | |
|---|
| 2 | 2 | Supply and fixing mild steel Hydrocyclone filter with 2 solid flange suitable for 75mm bore pipe and capacity of 30 Cum/hour (minimum) equipped with pressure check assembly for head control unit in drip irrigation system, complete all as specified & directed. (Make: Jain Irrigation System or equivalent in makes mentioned in Appendix 'B' here-in-after) | | 2 | Each |
|---|
| 3 | 3 | Supply and fixing PP Manifold suitable for 75mm bore pipe for filter unit in drip irrigation & Pop up system, complete all as specified & as directed. | | 2 | Each |
|---|
| 4 | 4 | Supply and fixing PVC Venturi Injector for Fertigation Manifold assembly of size 63 mm for head control unit IS : 14483-1997 complete all as directed. (Make: Jain Irrigation System or equivalent in makes mentioned in Appendix 'B' here-in-after) | | 2 | Each |
|---|
| 5 | 5 | Supply and fixing Air relese valve (plastic) size of 25 mm dia for head control unit in dirip irrigation system , complete all as specified & as directed. | | 2 | Each |
|---|
| 6 | 6 | Supply and fixing pressure relief valve (PVC) of size 63 mm dia for releasing excess pressure generated in drip irrigation & Pop up system, complete all as specified & as directed. | | 2 | Each |
|---|
| 7 | 7 | Supply and fixing Glycerine filled Pressure Gauge of capacity of 0-7 Kg/sqcm suitable for fixing on pipe of 63mm dia for head control unit in drip irrigation system, complete all as specified & as directed. | | 2 | Each |
|---|
| 8 | 8 | Supply and fixing disc filter (PVC) suitable for 75mm bore pipe and capacity of 30 Cum/hour for head control unit in drip irrigation system IS : 12785-1994, complete all as specified & as directed. (Make: Jain Irrigation System or equivalent in makes mentioned in Appendix 'B' here-in-after) | | 2 | Each |
|---|
| 9 | 9 | Supply and fixing PP Control valve suitable for 75mm bore pipe for storage water tank in drip irrigation system complete all as specified & as directed. | | 69 | Each |
|---|
| 10 | 10 | Supply and fixing unplasticised PVC pipe 90mm bore of pressure rating 4 Kg/sqcm conforming to IS-4985 (ISI marked), jointing the pipes as per manufacturer’s instructions, laid in trenches / floor / on ground, etc for main distribution line in drip irrigation system, complete all as specified & as directed.\nNote :- Excavation & earthwork shall be measured & paid for separately under relevant items. | | 130 | RM |
|---|
| 11 | 11 | Supply and fixing unplasticised PVC pipe 63mm bore of pressure rating 4 Kg/sqcm conforming to IS-4985 (ISI marked), jointing the pipes as per manufacturer’s instructions, laid in trenches / floor / on ground, etc for sub distribution line in drip irrigation system, complete all as specified & as directed.\n(Note :- Excavation & earthwork shall be measured & paid for separately under relevant items.) | | 1400 | RM |
|---|
| 12 | 12 | Supply and fixing PVC Control valve (Plain End) of size 63mm dia for distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 37 | Each |
|---|
| 13 | 13 | Supply and fixing unplasticised PVC pipe 75mm bore of pressure rating 6 Kg/sqcm conforming to IS-4985 (ISI marked), jointing the pipes as per manufacturer’s instructions, laid in trenches / floor / on ground, etc for main line in Pop up/drip irrigation system, complete all as specified & as directed.\n(Note :- Excavation & earthwork shall be measured & paid for separately under relevant items.) | | 650 | RM |
|---|
| 14 | 14 | Supply and fixing PVC Flush valve of size 75mmx63mm dia for sub distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 76 | Each |
|---|
| 15 | 15 | Supply and fixing PVC Plain lateral pipe 2.5 Kg/sqcm, Class-II of size 32mm dia, IS : 12786, for water distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 3500 | RM |
|---|
| 16 | 16 | Supply and fixing PVC Service Saddle of size 63mmx32mm for water distribution line in drip irrigation system with & including accessories i.e. nuts, bolts, washers etc, complete all as specified & as directed. | | 64 | Each |
|---|
| 17 | 17 | Supply and fixing push type male threaded adopter (PVC) of size 32mm dia for water distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 105 | Each |
|---|
| 18 | 18 | Supply and fixing PVC Control valve (Threaded End) of size 32mm dia for sub distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 74 | Each |
|---|
| 19 | 19 | Supply and fixing push type connector (PVC) of size 32mm x 32mm dia for water distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 58 | Each |
|---|
| 20 | 20 | Supply and fixing push type End Cap (PVC) of size 32mm dia for water distribution line in drip irrigation system, complete all as specified & as directed. | | 67 | Each |
|---|
| 21 | 21 | Supply and fixing PVC Plain lateral pipe 2.5 Kg/sqcm, Class-II of size 16mm dia, IS : 12786, for water distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 4200 | RM |
|---|
| 22 | 22 | Supply and fixing Grommet (PVC) including take off size of 16mm dia for water distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 300 | Each |
|---|
| 23 | 23 | Supply and fixing joiner (PVC) 16mm dia for water distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 20 | Each |
|---|
| 24 | 24 | Supply and fixing lateral cock (PVC) of size 16mm dia for water distribution line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 300 | Each |
|---|
| 25 | 25 | Supply and fixing push type End Cap (PVC) of size 16mm dia for water distribution line in drip irrigation system, complete all as specified & as directed. | | 890 | Each |
|---|
| 26 | 26 | Supply and fixing PVC Dripper (emitter) of capacity 8 LPH for drip irrigation system with & including accessories, complete all as specified & as directed. | | 798 | Each |
|---|
| 27 | 27 | Supply and fixing PVC emitting pipe of 16mm dia, discharge 2 LPH, 2.5 Kg/sqcm, IS:13488, for hedge, complete all as specified & as directed. | | 400 | RM |
|---|
| 28 | 28 | Supply and fixing PVC Elbow of size 75mm dia for water distribution line in drip irrigation system, complete all as specified & as directed. | | 22 | Each |
|---|
| 29 | 29 | Supply and fixing PVC Female Threaded Adopter of size 75mm dia for filter unit in drip irrigation system with & including accessories, complete all as specified & as directed. | | 2 | Each |
|---|
| 30 | 30 | Supply and fixing PVC Male Threaded Adopter of size 75mm dia for filter unit line in drip irrigation system with & including accessories, complete all as specified & as directed. | | 2 | Each |
|---|
| 31 | 31 | Supply and fixing push type PVC Tee of size 90mmx90mmx90mm for water distribution line in drip irrigation system, complete all as specified & as directed. | | 10 | Each |
|---|
| 32 | 32 | Supply and fixing push type PVC Tee of size 75mmx75mmx75mm for water distribution line in drip irrigation system, complete all as specified & as directed. | | 8 | Each |
|---|
| 33 | 33 | Supply and fixing push type PVC Tee of size 63mmx63mmx63mm for water distribution line in drip irrigation system, complete all as specified & as directed. | | 9 | Each |
|---|
| 34 | 34 | Supply and fixing push type PVC Tee of size 32mmx32mmx32mm for water distribution line in drip irrigation system, complete all as specified & as directed. | | 67 | Each |
|---|
| 35 | 35 | Supply and fixing push type PVC Tee of size 75mmx75mmx63mm for water distribution line in drip irrigation system, complete all as specified & as directed. | | 22 | Each |
|---|
| 36 | 36 | Supply and fixing PVC reducer of size 75mmx63mm for water distribution line in drip irrigation system, complete all as specified & as directed. | | 12 | Each |
|---|
| 37 | 37 | Supply and fixing PVC reducer of size 90mmx75mm for water distribution line in drip irrigation system, complete all as specified & as directed. | | 36 | Each |
|---|
| 38 | 38 | Supply and fixing Pop-up impact sprinkler of heavy duty plastic, adjustable to full circle or part circle with diffuser screw for fine droplets and throw control, inlet size 3/4\", having radius of throw 12m at pressure 3.5 Kg/sqcm for irrigation system, complete all as specified & as directed. | | 50 | Each |
|---|
| 39 | 39 | Supply and fixing swing joint full three way adjustable including height for Pop-up impact sprinkler of durable polyethylene construction for size 3/4\", complete all as specified & as directed. | | 50 | Each |
|---|
| 40 | 40 | Supply and fixing PP Service Saddle of size 63mmx25mm for jointing of swing joint to PVC pipe of 50mm bore for Pop-up sprinkler with & including accessories, complete all as specified & as directed. | | 50 | Each |
|---|
| 41 | 41 | Supply and fixing PVC Elbow of size 63mm dia for water distribution line in Pop-up/drip irrigation system, complete all as specified & as directed. | | 12 | Each |
|---|
| 42 | 42 | Supply and fixing push type End Cap (PVC) of size 63mm dia for water distribution line in Pop-up/drip irrigation system, complete all as specified & as directed. | | 10 | Each |
|---|
| 43 | 43 | Supply, install, testing and commissioning of horizontal openwell submersible pump set with electric driven motor 3 HP capacity, with supply voltage 415V, Three Phase, 50Hz, discharge capacity 830-360 LPM at 10.5 - 21 mtr head, suction and delivery size 65mm x 65mm including suitable size of strainer, mounted on & including suitable size foundation (minimum size 60cm x 60cm x 60cm) in PCC (1:2:4) type B1 and fixed with MS bolts, nuts of required size, properly connected with suction and delivery water pipe line, with & including 6 sqmm 3 core multistranded copper conductor PVC insulated and sheathed copper screen protected submersible flat cable 1100 Volts grade (20 mtr long) complete all as specified and directed. | | 2 | Each Job |
|---|
| 44 | 44 | Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. | | 1264 | Cum |
|---|
| 45 | 45 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed. | | 1172 | Cum |
|---|
| 46 | 46 | Removing excavated soil/material to a distance exc 250 metre but not exc 500 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and as directed. | | 92 | Cum |
|---|
| 47 | 47 | M&L for making branch connection by cutting existing underground CI/DI/GI main water pipe line of 100mm bore with & including inserting Tee of size 100mmx100mmx75mm including necessary earth work, dewatering, etc complete all as specified & as directed. | | 1 | Each |
|---|
| 48 | 48 | M&L for making branch connection by cutting existing underground CI/DI/GI main water pipe line of 80mm bore with & including inserting Tee of size 80mmx80mmx75mm including necessary earth work, dewatering, etc complete all as specified & as directed. | | 1 | Each |
|---|
| 49 | 49 | Material for Cutting/dismantling of PCC hardstanding/WBM road with soiling & premix carpet of any description for laying of arboriculture water distribution pipe lines and disposl of removal matrieal to a distance exc 250m but not exc 500m and making good the same with & including black top of surface dressing renewal coat by spraying evenly paving bitumen at 12 kg per 10 sqm chipping @ 0.10 cum per 10 sqm and rolling to required gradient and camber complete all as specified & directed. | | 5 | Cum |
|---|
| 50 | 50 | M & L for boring of holes under main road pavment,hard standing by trenchless technology using ultra sound tecnique and necessary machine for accomodet 50mm bore GI tube (light grade) in the drilled holes,returning ,filling in the end working space including removal of surplus soil and making good the surface.\nNote : (GI pipe light grade shall be measured and paid separately) | | 40 | RM |
|---|
| 51 | 51 | Supply and fixing Ductile Iron fittings, specials (K-12) such as bends, tapers, collars, reducers, tee pieces (single or double branch) any type, angle/radius and straight connecting pieces etc (ISI marked) conforming to IS 9523 for flanged/socket and spigot ends suitable for DI pipe upto 150 mm bore with jointing material complete all as specified and directed. | | 75 | Kg |
|---|
| 52 | 52 | M&L for galvanized steel water tubing medium grade of 50mm bore made to shape as required with & including all fittings such as Tee, union, etc and fixed complete to walls and ceilings or laid in floors, for fountain work, complete all as specified & directed.\n | | 20 | RM |
|---|
| 53 | 53 | Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & as directed. \nNote :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. | | 200 | RM |
|---|
| 54 | 54 | M&L for dry sand (Local Tibba sand) and punning for cushioning and cover for protection of under ground electric cable complete all as specified and as directed.\nNotes :-\n(i) Approved local Tibba dry sand free from vegetations, grass and other deleterious substances shall be used.\n(ii) For the purpose of payment, only punned thickness shall be measured. | | 15 | Cum |
|---|
| 55 | 55 | M&L for sub class ‘B’ (old size) burnt clay bricks laid flat and dry abutting each other with gap between adjacent bricks not exc. 10mm for protection of underground electric cable in such a way that the length of brick is at right angle to the central axis of cable complete all as specified and as directed. | | 1.5 | Per 1000 Nos |
|---|
| 56 | 56 | Supply and fixing MCCB 415 V, 16 KA, 4 Pole of capacity 63 Amp, existing panel complete all as specified and as directed. | | 2 | Each |
|---|
| 57 | 57 | M&L for Valve Pit of internal size 100cm x 100cm x 100cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2. | | 2 | Each job |
|---|
| 58 | 58 | M&L for Valve Pit of internal size 60cm x 60cm x 70cm built in brick masonry complete all as specified in Particular Specifications and as shown on drawing No. BTD-811 Sheet No. 1/2 & 2/2. | | 10 | Each job |
|---|
| 59 | 59 | S&F 50mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed. | | 2 | Each |
|---|
| 60 | 60 | Supply and fixing Sluice valve 80mm dia with flanged ends class I PN-1 .0 heavy duty ISI marked, drilled type, non raising type : IS- 14846-2000 mark, including iron wheel complete with suitable rubber insertion 3.0mm thick at both ends with suitable MS bolts, nuts and washers, and testing, complete all as specified & as directed. | | 2 | Each |
|---|
| 61 | 61 | Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT feeder pillar box KIOSK, outdoor type, suitable for 415 Volts, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, protection class IP-65, having bus bar chamber with insulated aluminium bus bars of 200 Amps rating in colour code RYB with 3 phase & neutral installed on insulators. The panel shall be dust and vermin proof, made out of 3.15mm thick CRCA MS sheet and 50X50X6mm thick angle iron for base frame work. The complete feeder pillar box shall be powder coated inside & outside (of approval shade) including suitable size of copper strip from bus bar to MCCB and internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size but not less than 6 Sqmm with proper ferrule & cable gland, front openable with aprons for cable entry with door shutter including locking arrangement as per manufacturers, all as specified and directed. The scope of work includes supply & fixing of the following :-\n(a) Incoming MCCB, 4 Pole, 25 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type – 01 No.\n(b) Outgoing MCCB, 3 Pole, 20 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, Magnetic fixed type – 01 No.\n(c) Digital Volt meter 0-500 Volts with built in 3 way selector switch – 01 No.\n(d) Digital Amp meter 0-100 Amps with CTs of 100/5 ratio and built in 3 way selector switch – 01 No\n(e) Indicator Set RYB “LED” type complete – 01 Set\n(f) Single phase preventer suitable for 3 HP submersible pump set\n(g) Fully automatic star delta starter in sheet steel enclosure, suitable for 3 HP electric Motor, 3 phase, 415 volt, 50 Hz – 01 No.\n | | 2 | Each Job |
|---|
| 62 | 62 | M&L for Earthing to pumps / motors / panels / equipments etc with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 25x4 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to pumps / motors / panels / equipment body / test point etc with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed.\nNote : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. | | 4 | Each Set |
|---|
| 63 | 63 | Supply and Planting of 'Neem\" plants in poly bags of 0.25m to 0.30m poly bags with height 1.50m to 1.80m including digging holes 1.20m dia x 1.20m deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio 2:1 (2 parts of stacked volume of earth after reduction of 20% with 1 part of stacked volume of sludge or manure after reduction by 8%) flooding with water and removal of surplus soil, with & including antitermite treatment using suitable chemicals as required and making ‘Thaola’ complete all as specified and as directed :- \nNotes :-\n(i) The contractor’s quoted rates shall be deemed to include for necessary excavation and earth work, necessary manure or sludge and antitermite treatment of soil including necessary chemicals etc.\n(ii) The excavated earth if found suitable and approved by GE shall be used for filling in the holes after planting of trees/plants. However, in case the excavated earth is not found suitable for refilling and not approved by GE, contractor shall arrange suitable good earth from his own sources as approved by GE and contractor's quoted rates shall be deemed to include for arranging and transporting of good earth including filling in the holes and nothing extra shall be admissible on this account. | | 900 | Each |
|---|
| 64 | 64 | All as per srial Item No 63.00 above but of Gulmohar. | | 125 | Each |
|---|
| 65 | 65 | All as per srial Item No 63.00 above but of Peepal. | | 25 | Each |
|---|
| 66 | 66 | All as per srial Item No 63.00 above but of Vat/Bargad. | | 40 | Each |
|---|
| 67 | 67 | All as per srial Item No 63.00 above but of Seesham. | | 160 | Each |
|---|
| 68 | 68 | All as per srial Item No 63.00 above but of Tali. | | 160 | Each |
|---|
| 69 | 69 | All as per srial Item No 63 above but of Mopen. | | 160 | Each |
|---|
| 70 | 70 | All as per srial Item No 63 above but of Palm. | | 90 | Each |
|---|
| 71 | 71 | All as per srial Item No 63.00 above but of Bougan villea. | | 125 | Each |
|---|
| 72 | 72 | All as per srial Item No 63.00 above but of Champa/Plumerie. | | 125 | Each |
|---|
| 73 | 73 | All as per srial Item No 63.00 above but of Chameli/Jasmine. | | 125 | Each |
|---|
| 74 | 74 | All as per srial Item No 63.00 above but of Dates. | | 150 | Each |
|---|
| 75 | 75 | All as per srial Item No 63.00 above but of Guava. | | 150 | Each |
|---|
| 76 | 76 | All as per srial Item No 63.00 above but of Anar. | | 150 | Each |
|---|
| 77 | 77 | Supply and planting of Hedge and Shrubbery (Mehandi, Tikkam & Sehjan and the like) as directed by Engineer in Charge including creation of Beds by excavating 60 cm deep and 60 cm wide trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio 8: 1 ( 8 parts of stacked volime of earth after reduction of 20% with 1 part of stacked volume of manure after reduction by 8%) flooding with water filling with earth if necesary, watering and finally fine dressing levelling etc including stacking and disposal of material declared unservisable and surplus earth by spreading and levelling as directed within a lead of 50 m and lift upto 1.50 m complete all as specified and directed. | | 129 | RM |
|---|
| 78 | 78 | M&L for Grassing with \"Doob\" grass including enough watering and maintenance of the lawn till the grass forms a thick lawn free form weeds and fit for mowing including supplying good earth if needed including supplying and spreading of Neem oil cakes, manure or sludge and chemical required for preparation of the ground for plantation of grass, complete all as specified & as directed. | | 3115 | Sqm |
|---|
| 79 | 79 | Rotational moulded polyethylene water storage tanks of 5000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted on rrof/lowered undergroung and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed by Engineer-in-Charge. (i) The water storage tanks shall be tripal layers , HDPE tanks moulded to seam-less perfection of rotational moulding process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. Also refer paras 18.60 and 18.60 A of MES Schedule Part-I.\n(ii) HDPE storage tanks shall be as per IS-12701 and procured from the manufacturers as per Appendix “B”.)\n | | 4 | Each |
|---|
| 80 | 80 | SCHEDULE ‘A’ SECTION-II | | | |
|---|
| 81 | 81 | M&L for maintenance of all Plants, Hedge, Shrubbery and Grass at Med Regt at Military Station Bikaner by weeding, hosing, saucer making once in every month for plants /hedge, once in every 15 days for carpet grass / country grass / doob grass, Burmuda grass, pruning dried branches once in every week, depositing the material at place as directed by Engineer-in-Charge and planting the new plants in place of dead plants of same species and height turning with dods wherever required by replacing the dead patches of grass of any type with same grass as required without any extra cost to the department including watering to Plants for minimum two hours daily by operation of water pump, Hedge, Shrubbery and Grass and clening the filters in drip irrigation system, complete all as specified and as directed. | | 12 | Each Calendar Month |
|---|