Repair/ Replacement Of Roof Sheet , Ceiling And Roof Treatment Floor Sanitery Fittings , Wall And Floor Tiling , Joinery And Rewiring Of Internal Electrification Incl Replacement Of Electrical Fittings , Fixtures In Md And Otm Accn At Mil Stn Kalka Un, KALKA-Haryana

Military Engineer Services-MES has published Repair/ Replacement Of Roof Sheet , Ceiling And Roof Treatment Floor Sanitery Fittings , Wall And Floor Tiling , Joinery And Rewiring Of Internal Electrification Incl Replacement Of Electrical Fittings , Fixtures In Md And Otm Accn At Mil Stn Kalka Un. Submission Date for this Tender is 13-03-2021. Electrification Work Tenders in KALKA Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

27010784
Corrigendum : Repair/ Replacement Of Roof Sheet , Ceiling And Roof Treatment Floor Sanitery Fittings , Wall And Floor Tiling , Joinery And Rewiring Of Internal Electrification Incl Replacement Of Electrical Fittings , Fixtures In Md And Otm Accn At Mil Stn Kalka Un
National Competitive Bid
Indian
Haryana
KALKA
13-03-2021

Tender Details

Repair/ Replacement Of Roof Sheet , Ceiling And Roof Treatment Floor Sanitery Fittings , Wall And Floor Tiling , Joinery And Rewiring Of Internal Electrification Incl Replacement Of Electrical Fittings , Fixtures In Md And Otm Accn At Mil Stn Kalka Under

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Feb-2021 Reduction in performance security and changes in BOQ BOQ 06-03-2021
2 06-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 46000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF ROOF SHEET, CEILING AND ROOF TREATMENT FLOOR SANITERY FITTINGS, WALL AND FLOOR TILING, JOINERY AND REWIRING OF INTERNAL ELECTRIFICATION INCL REPLACEMENT OF ELECTRICAL FITTINGS, FIXTURES IN MD AND OTM ACCN AT MIL STN KALKA UNDER GE JUTOGH.
Sl. No. Item Description Item Code / Make Qty Units
1 1 Dismantling, floor, hearth or wall tiling including cement mortar bedding and, removing rubbish off the premises complete all as specified and directed. 443 Sqm
2 2 Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15cm thick (below or above ground level) and removing rubbish off the premises to a distance n exc 150 m & deposited where directed at a level in exc 1.5m above the starting point complete all as specified and directed. 1 Cum
3 3 M & L for 75mm thick PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in sub base complete all as specified and directed. 14 Sqm
4 4 M&L Non skid ceramic coloured tiles 7 to 8mm thick square/rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed with cement mortar 1:6 complete all as specified and directed. 170 Sqm
5 5 M&L Non skid ceramic coloured tiles 7 to 8mm thick square/rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 in skirting/dado and riser to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick backing coat with cement mortar 1:4 complete all as specified and directed. 24 Sqm
6 6 M&L for Non Skid ceramic coloured tiles 7 to 8 mm thick square/rectangular area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cemeent to match laid over and including 15mm thick screed bed with cement mortar 1:6 complete all as specified and directed. 54 Sqm
7 7 M&L for Glazed ceramic colored tiles on verticle surface such as skirting/dado etc. 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match to coloured tiles.over Including 10 mm thick backing coat in CM 1:4 complete all as specified and directed. 180 Sqm
8 8 M&L for Granite (of any type) 18-20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone including cutting and polishing fixed over and including 15mm thick screed bed with cement mortar 1:6 complete all as specified and directed. 15 Sqm
9 9 Taking down chowkats or frames with shutter exc 1.5 sqm but n.exc 4.0 sqm (without taking off shutters from frames) and removing from site including making good the distrurbed surfaces complete all as specified and directed. 4 Each
10 10 Taking down chowkats or frames with shutter not exc 1.5 sqm (without taking off shutters from frames) and removing from site including making good the distrurbed surfaces complete all as specified and directed. 16 Each
11 11 Taking down shutters of any description exc 1 Sqm and not exc 2 Sqm each and removing from site complete all as specified and directed. 14 Per Leaf
12 12 Taking down shutters of any description exc 2 Sqm and not exc 4 Sqm each and removing from site complete all as specified and directed. 2 Each
13 13 Taking down shutters of any description exceeding 1 Sqm and not exceeding 2 Sqm each and refixing in the same opening after necessary repair etc complete all as specified and directed. 20 Each
14 14 S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. 55 RM
15 15 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded palin colour PVC `C' channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bbottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification complete all as specified and directed. 17 Sqm
16 16 S & F 35mm thick factory made plain framed panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm venerred particle board with commercial veneering on both faces. The size of rail and style as per IS- 1003 (part -I) kiln seasoned and chemically pressure treated of 2nd class hardwood rails and style for doors complete all as specified incl one shop coat of pink primer complete all as specified and directed. 12 Sqm
17 17 S&F 35mm thick IInd class hard wood glazed & skeleton shutters,open rebated & prepare to receive gauge, divided into squares, with plain, chamfered and rounded, mitred and rebated sash bars, any numbers members of shutters as specified SSR Pt-I , clause 8.24(a) complete all as specified and directed. 12 Sqm
18 18 S&F 100mm size butt hinge extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and directed. 150 Each
19 19 S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised fixed complete all as specified and directed. 55 Each
20 20 S&F 200mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. 55 Each
21 21 S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. 6 Each
22 22 M&L for complete removal of existing treatment on wall (any number of layers) by scrapping with steel scrappers or any other means, preparation of surfaces for applying 3mm thick wall care putty and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. 840 Sqm
23 23 S&F in repair prelaminated particle board, 18/19mm thick interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, incl fixed with screws to timber frame work as in cup board, cabinets and similer type of work icl fixed on wall with fastener or suitable arrangement complete all as specified and directed. 4 Sqm
24 24 S&F in repair prelaminated particle board, 12mm thick interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in cup board, cabinets and similer type of work complete all as specified and directed. 8 Sqm
25 25 M&L for 2nd class hard wood Plain fillets, square, rectangular or traingular in cross section of size Exc 3 & n. exc 6 sq. cm, clean sawn, secured with nails or brads, complete all as specified and directed. 20 RM
26 26 M&L for 2nd class hard wood Plain fillets, square, rectangular or traingular in cross section of size Exc 13 & n. exc 25 sq. cm, clean sawn, secured with nails or brads, complete all as specified and directed. 5 RM
27 27 Taking up or down 15mm bore steel water tubing and connections incl cleaning for refixing or removal from site of 15mm bore complete all as specified and directed. 36 RM
28 28 S & F 15mm bore galvanised steel water tubes medium grade with all fittings and fixed to walls and ceilings or laid in floor complete all as specified and directed. 24 RM
29 29 Re-fixing old steel tubing 15 mm bore with new fittings and connections in new or old positions, complete all as specified and directed. 12 RM
30 30 Taking up or down 20mm bore steel water tubing and connections incl cleaning for refixing or removal from site o complete all as specified and directed. 24 RM
31 31 S & F 20mm bore galvanised steel water tubes medium grade with all fittings and fixed to walls and ceilings or laid in floor complete all as specified and directed. 12 RM
32 32 Re-fixing old steel tubing 20 mm bore with new fittings and connections in new or old positions, complete all as specified and directed. 12 RM
33 33 S&F in repairs, vitreous China wash hand basin, white, flat back size 550 x 400mm including CP brass waste coupling, 600 mm long 32mm bore HDPE waste down pipe including CI brackets complete all as specified and directed. 6 Each
34 34 S&F in repair 15mm bore chromium plated Pillar tap, cast copper alloy with capstain head, screwed down high pressure with long screwed shank and fly nut complete all as specified and directed. 6 Each
35 35 S & F in repair stop valve of 15mm bore cast copper alloy fancy type chromium plated with long shank and cup (concealed type) screwed down high pressure with crtuch or butterfly handle capstan head screwed both ends for iron pipe or for unions complete all as specified and directed. 6 Each
36 36 S & F in repair stop/angle valve of 15mm bore cast copper alloy fancy type chromium plated screwed down high pressure with crtuch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed. 18 Each
37 37 S & F in repair 15mm bore bib tap fancy type chromoimplated cast copper alloy with crutch or butterfly handle screwed down secrewed for iron pipe or for brass ferrule complete all as specified and directed. 24 Each
38 38 S & F in repair brass chrominum plated shower rose 100mm size with or without swivel joint incl fixing to steel pipe of size 15mm bore complete all as specified and directed. 6 Each
39 39 Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15cm thick (below or above ground level) and removing rubbish off the premises to a distance n exc 150 m & deposited where directed at a level in exc 1.5m above the starting point complete all as specified. 2.5 Cum
40 40 M&L for PCC 1:5:10 type E-2 using40 mm graded crushed aggregate) in foundations, filling and mass-concrete as in sunken slab etc complete all as specified and directed. 2.5 Cum
41 41 M&L for rendering 15mm thick in cement mortar 1:4 on concrete surfaces of sunken portion finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions complete all as specified and directed. Note: WPC shall be measured and paid separately. 15 Sqm
42 42 Supply only Integral water proofing compound complete all as specified and directed. 35 Kg
43 43 S & F in repair viteous china squating pan " ORISSA PATTERN" of size 630 x 450 mm white with integral foot rest or back inlet and making good the floor with PCC 1:2:4 type B-1, incl 125/110mm bore, PVC (SWR), 'P' or 'S' trap complete all as specified and directed. 6 Each
44 44 S & F in repair PVC valveless, syphonic action type, flushing cistern, low level, white, with intel, ball valve, float, flush pipe and handle including brackets complete all as specified and directed. 6 Each
45 45 S & F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. 18 Each
46 46 S&F in repairs looking mirror of size 600x 450mm bevelled edge mirror of selected quality glass , mounted on 5mm thick PVC sheet and fancy frame and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 6 Each
47 47 S & F in repair Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/ plastic cleats (minimum weight 300 gms) complete all as specified and directed. 6 Each
48 48 S&F in repair Tubler towel rail, 20mm dia D type 60 CM long between flanges complete all as specified and directed. 6 Each
49 49 S&F Hasp and staple, safety type of aluminium anodised including bolt to hinge plate, fixed with screws of 100mm size complete all as specified and directed. 6 Each
50 50 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed. 24 RM
51 51 Hacking out old broken glass (any thicknesss, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. 5 Sqm
52 52 Hacking out old broken glass (any thicknesss, size,quality or description) from metal frame inlcuding punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed. 5 Sqm
53 53 S & F 3 mm thick plain glass, pin headed type and fixed with wooden beads in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed. 10 Sqm
54 54 S& F in repair galvanised mild steel wire cloth 0.56mm nominal dia or wire and average width or aperture 1.18mm and fixed with stainless steel wire staple in complete all as specified and directed. 10 Sqm
55 55 M & L for preparation of new or previosuly untreated wooden surfaces of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed. 15 Sqm
56 56 M & L for preparation of old or previosuly treated wooden surfaces of any description not otherwise described over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed. 15 Sqm
57 57 M & L for preparation of old or previously treated steel surfaces of any descirption not otherwise described over 10cm width or grith and applying one coat of synthetic enamel paint complete all as specified and directed. 10 Sqm
58 58 S & F in repairs PVC (SWR) pipes 110 mm bore single socketed, in any length, with rubber ring joints, laid in trenches or under floors, inserted in retaining wall etc complete all as specified and directed. 10 RM
59 59 S & F in repairs PVC (SWR) pipes 75 mm bore single socketed, in any length, with rubber ring joints, laid in trenches or under floors, inserted in retaining wall etc complete all as specified & directed. 10 RM
60 60 S & F in repairs PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed. 40 RM
61 61 S & F in repairs PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to wall setc complete all as specified and directed. 20 RM
62 62 S&F in repair 110 mm dia PVC (SWR) bends with access door complete all as specified and directed. 6 Each
63 63 S&F in repair 110 mm bore, PVC (SWR), Junction, (Single T/Y), equal or unequal with access door complete all as specified and directed. 5 Each
64 64 S&F in repair 75 mm bore, PVC (SWR), Junction (Single T/Y), equal or unequal with access door complete all as specified and directed. 5 Each
65 65 S&F in repair 75 mm bore, PVC (SWR), floor trap, plain with grating including jointing with solvent, cement, complete all as specified and directed. 5 Each
66 66 S&F in repair Salt-glazed stone ware gully traps,125/110 mm, square or round mouthed, type `P' PVC (SWR) setting and jointing with cement complete all as specified and directed. 5 Each
67 67 S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm incl waist copling and waste pipe complete all as specified and as directed . 6 Each
68 68 Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed. 200 Sqm
69 69 Dismantling Asbestos cement (corrugated, semicorrugated , etc) sheets n roof coverings complete all as specified and directed. 100 Sqm
70 70 S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 300 Sqm
71 71 S & F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specified. 20 Sqm
72 72 Dismantling wrought iron or mild steel work of any description in any position not otherwise provided for complete all as specified and directed. 0.5 Qtl
73 73 Dismantling timber scantlings framed 40 sq. cm and over in section, in any position complete all as specified and directed. 0.5 Cum
74 74 Dismantling timber scantlings un framed in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section 40 sq. cm and over in section, in any position complete all as specified and directed. 150 RM
75 75 S&F mild steel hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. 1200 Kg
76 76 M&L or framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. 500 Kg
77 77 M&L for framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work complete all as specified and directed. 200 Kg
78 78 M & L for preparation of new or previously untreated steel surfaces of any descirption not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and directed. 50 Sqm
79 79 Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. 250 Sqm
80 80 S&F GI frame work for ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 & 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section(not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.50mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre. size of grid 605mmx605mm incl Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. 250 Sqm
81 81 S&F 4mm thick non asbestos fibre cement building boards white/off white (E board designer) fixed or laid /inserted to timber/GI/Aluminium frame work with screws in ceiling flat or sloping complete all as specified and directed. 250 Sqm
82 82 Demolition of mud in roofs, any thicknes, including plastering and leeping (whether full thickness removed or only or part thereof) etc complete all as specified and directed. 18.75 Cum
83 83 M & L for PCC 1:2:4 type B-1 using 20mm graded crushed stone agg as in roof kerb or mud stopes, padding on roof etc finished even and fair, average thickness as required to maintain proper slope complete all as specified and directed. 8 Cum
84 84 M&L for rendering 15mm thick in cement mortar 1:4 on concrete surfaces of roof finished even and smooth without using extra cement mixed with water proofing compound of approved make as per manufacturers instructions on existing roof surfaces complete all as specified and directed. Note: WPC shall be measured and paid separately under respective item of BOQ. 250 Sqm
85 85 M&L for roof treatment, cleaning of old roof slab surfaces including sweeping clean &washing down with water to remove dust & providing water proofing treatment with polymeric standard water proofing membrane complete all as specified and directed as under:- (a) Preparation of plaster surfaces /RCC roof surfaces and applying one coat of oil bound bituminous primer @0.30 Ltr/sqm (b) Applying bitumen @1.20kg/sqm of grade 85/25 (c) Supplying and laying modified polymeric water proofing membrane super thermo lay 3mm thick of weight not less than 3.00kg /sqm reinforced with polyester non woven fabric weight not less than 150gm/sqm center core including coping on the surfaces with torch application of membrane with 10cm over laps as required and dorected. (d) Applying aluminium paint @ 0.20Kg/Sqm. 250 Sqm
86 86 Demolition of brick or stone masonry, built in cement mortar incl all quoins, pillars, arches etc but excluding ashlar facing complete all as specified and directed. 5 Cum
87 87 M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6 m mean radius, built in CM (1:6) complete all as specified and directed.. 4 Cum
88 88 M & L for brick work with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. 10 Sqm
89 89 Taking down of cement plaster on walls and ceiling of any description incl raking out of joints hacking for key scrubbing down with water etc complete all as specified and directed. 30 Sqm
90 90 M & L for rendering 10mm thick in cement mortar (1:6) on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 50 Sqm
91 91 M & L for 15mm thick rendering in CM 1:4 mixed with water proofing compound as per manufacturer's instruction finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately under respective item of BOQ. 100 Sqm
92 92 M&L for preparing newly plastered surface of wall and applying two coats of oil bound distemper over a coat of primer suitable for distempring complete all as specified and directed. 50 Sqm
93 93 M & L for preperation of new plastered surface of wall and applying two coats of cement base paint complete all as specified and directed. 100 Sqm
94 94 S&F powder coated (minimum thickness of powder coating 50 micron) Anodised aluminium section of any size for frame of doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 25 Kg
95 95 S & F aluminum section powder coated of colour as approved door with frame and shutters partially glazing 5.5mm thick one side plain/colour glass and PVC composite board 5mm thick fixed with aluminium clip beeding. door section of aluminium door shutter as under complete and all as specified and directed (i) Frame 100x40x2mm (ii) shutter style 85x44.45x3mm thick section (iii) Top rail 95.25 x44.45x1.7mm thick (iv) middle rail 83.50x44.75x1.7mm thick (v) Bottom rail 114.30X44.15X1.7mm thick section (vi) Glazing clip 0.7mm thick (vii) 2 Nos Handle Powder coated Aluminium 200mm long as approved (viii) Tower bolt 9.90mm dia and 200mm long (ix) Mortice lock 100MM 7 LIVER (x) Hold fast aluminium 100mm long (xi) Reinforced with 2 No 10mm dia MS bar with bolt complete on top and bottom rail of door (Note: PVC/rubber lining brush for alround door shall be provided) 5 Sqm
96 96 S&F Aluminium anodised powder coated sliding type three track window with shutter and frame including aluminium grill and mosquito proofing net and 5 mm thick tinted glass , size of frame 91.50 x 31.75 x 1.3mm thick for top and sides, bottum and shutter frame 38 x 18 x 1.5mm thick, necessary handles, joining cleats, glazing clips, rubber packing, locking arengement, beeding etc. complete all as specified and directed. 5 Sqm
97 97 S&F aluminium section powder coated of colour as approved for partition partially glazing 5.5mm thick plain/colour glass and PVC completed board 5mm thick fixed with aluminium beading joining cleats, glazing clips, rubber packing section completed all as specified and directed with frame 62x40x2mm & glazing clip 0.7mm thick with rubber packing complete. Consisting of Frame 62x40x2mm and partially glazing with 5.5mm thick plain/ colour glass and partially with PVC board 5mm thick fixed with aluminium beading, joining cleats, glazing clips 0.7mm thick, rubber packing complete all as specified and directed. 5 Sqm
98 98 M&L for taking down aluminium door & window shutters and refixing it on the same opening after repair/ replacement of unserviceable parts / hardware/glass complete all as specified and directed. Note: Items need to be replaced will be measured and paid saperately as supply only as the fixing of the same deemed to be included in this item. 10 Sqm
99 99 Supply only double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and directed. 3 Each
100 100 Supply only aluminium (extruded section body) Door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg complete all as specified and directed. 5 Each
101 101 Supply only (extruded section body) Mortice lock, vertical type, size 100mm 4 Levers suitable for aluminium door shutters complete all as specified and directed. 5 Each
102 102 Supply only 5.5 mm thick plain glass, pin headed type and fixed with wooden beads in squares exceeding 0.5 Sq. M in each pane complete all as specified and directed. 10 Sqm
103 103 Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface complete all as specified and directed. 198 Each point
104 104 M&L for point wiring with colour coding multistranded copper conductor cable, PVC insulated (FRLS) and unsheathed size 1.5 sqmm for phase and neutral with concealed conduit of medium grade with fixing accessories with pressed steel concealed terminal boxes covered with 3mm thick laminated sheet incl continous earth wire of PVC insulated unsheathed multi stranded copper conductor cable size 1.5 Sqmm for earth wire connected to common earth dolly, colour code of wires as per specification,complete all as specified and directed for the folloeing:-
105 104.01 One light/ fan point controlled by one switch complete all as specified and directed. 114 Per point
106 104.02 One 5 pin 5/6 Amp socket on the same board complete all as specified and directed. 24 Per point
107 104.03 One 5 pin 5/6 Amp socket on independent board complete all as specified and directed. 36 Per point
108 104.04 One 3 pin 15 Amp socket independent but with 2.5 sq mm PVC insulated unsheathed copper stranded conductor and 2.5 Sq mm size PVC insulated stranded copper conductor as earth continuity conductor complete all as specified and directed. 18 Per point
109 104.05 One bell point controlled by one push button switch complete all as specified and directed. 6 Per point
110 105 S & F switch piano type 240 V, 5 Amp , Sp one way flush type complete all as specified and directed. 174 Each
111 106 S & F bell push 240 V, 5 Amp , Sp one way flush type complete all as specified and directed. 6 Each
112 107 S&F socket 5 pins, 6 Amp, flush type piano (multi purpose), complete all as specified and directed. 60 Each
113 108 S&F Socket 15 Amps flush type 230 Volts , AC complete all as specified and directed. 18 Each
114 109 S&F switch 15 Amps flush type 230 Volts , ACcomplete all as specified and directed. 18 Each
115 110 M&L regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete as specified 18 Each
116 111 S&F ceiling rose surface backelite, 65 x 20 mm three terminal complete all as specified and directed. 78 Each
117 112 S&F for lamp holder pvc body with back plate with and including 9/10 Watt LED lamp complete all as specified and directed. 36 Each
118 113 S&F in repair sheet metal enclosure for MCB DB TPN double door, 4 way complete with 200 Amps rated Bus bar complete all as specified and directed. 1 Each
119 114 S&F in repair sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed. 6 Each
120 115 S&F MCB TPN 63 Amps 415V, 'C' series incl all termnials, fitting etc. complete all as specified and directed. 1 Each
121 116 S&F MCB SPN 32 Amps 250V, 'C' series incl all termnials, fitting etc. complete all as specified and directed. 12 Each
122 117 S&F MCB SP 6-32 Amp ,240V, 'C' series complete all as specified and directed. 38 Each
123 118 M&L for call bell electric (ding dong type) , 240 Volt , single pole complete all as specified and directed. 6 Each
124 119 M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 15 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion, complete all as specified and directed. 1 Each set
125 120 M&L for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated (FRLS) and unsheathed multi stranded copper conductor cable LT 1100 grade for phase /neutral and PVC rigid conduit 20 mm dia concealed with all necessary fittings and accessories and one run of PVC insulated and unsheathed single core cable with copper conductor of size 6 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old u/s sub main wiring complete all as specified and directed. Note. Two runs of cable for phase /neutral and one run of PVC conduit and one run of earth continuity wire shall be measured as one run. 60 RM
126 121 S&F in repair LED mirror light 10 watt with diffuser, decorative type with driver duly electrical connection from ceiling rose to fittings ccomplete all as specified and directed. Make : Havells cat part No ENDURALINEARNEOBS10WLED865SPCWH/ Polycab Cat Part No. LDO0103021/ Crompton Cat Part No. LCCLB-08-CDL 6 Each
127 122 S & F in repair LED tube light fitting 20W(4 feet) wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver, optics diffused duly electrical connection from ceiling rose to fittings, complete all as specified and directed. Make : Havells Cat part No ENDURALINEARNEOBS20WLED840SPCWH/ Polycab Cat part No LDO0103023/ Crompton cat part No LCCLB-24-CDL 48 Each
Disclaimer :