Special Repair To Bldg No T 10 And Replacement Of Corrugated Asbestos Sheets To Galvanium Sheet Of Otm Bldg No T 15 And T 37 At Mil Stn Banbasa Under Ge Mes Pithoragarh

Issued by Statutory Bodies & Commissions/Committees · Banbasa, Uttarakhand
Tender Value
27 Lakhs
Estimated cost
Bid Submission
08 Mar 2021
0 days left
EMD
54000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Banbasa → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Special Repair To Bldg No T 10 And Replacement Of Corrugated Asbestos Sheets To Galvanium Sheet Of Otm Bldg No T 15 And T 37 At Mil Stn Banbasa Under Ge Mes Pithoragarh

BOQ

Name of Work: SPL REPAIR TO BLDG NO T 10 AND REPLACEMENT OF CORRUGATED ASBESTOS SHEETS TO GALVANIUM SHEET OF OTM BLDG NO T 15 AND T 37 AT MIL STN BANBASA UNDER GE MES PITHORAGARH
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
10.05DESCRIPTION OF ITEMS
21Dismantling of corrugated or semi corrugated asbestos cement sheets in roof covering including ridges, hips, valley etc complete all as specified and directed.1470Sqm
32Dismantling of ceiling board of any description including cover fillets complete all as specified and directed.270Sqm
43Dismantling timber scantling 40 Sq cm and over framed work in any position complete all as specified and directed.9.5Cum
54Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, copings etc. built in cement mortar or cement lime mortar complete all as specified and directed.2Cum
65Demolition of cement concrete unreinforced in Ground floor & paving n.exc 15cm thickness and including removal of debris from site all as specified and directed2Cum
76Taking down chowkats of any description without taking of shutter from the frame not exceeding 1.5 sqm complete all as specified and directed.3Each
87Taking down chowkats of any description without taking of shutter from the frame exceeding 1.5 sqm but not exc. 4.0 sqm complete all as specified and directed.4Each
98Taking down shutter of any description not exceeding 1sqm complete all as specified and directed.15Each
109Taking down shutter of any description exceeding 2 sqm and complete all as specified and directed.5Each
1110M & L for Brick work built in CM 1:6 with sub class old size bricks straight or curved on plan exceeding 6 m mean radius all as specified and directed.\n\n2Cum
1211S & F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and as directed.5450Kg
1312M & L for suspended for ceiling system using chicago metallic E grid exposed suspended system of grid/section size 600x600mm comprising of GI powder coated main 39x24x0.8 mm thick (thickness comprising of GI/0.40+PPGS/0.3) cross TEE 29X24X0.8mm thick and wall angle 22.2x22.2x0.65mm thick with and including 4mm thick HPSC preprimed self embossed texture design board to be placed in the grid system duly suspend with 6mm dia GI wire hangers fixed with steel door fastness or from perlin of the roof with clip complete all as speceified and directed.270Sqm
1413S & F of mild steel hold fast, fan hooks, wind tie, cleat, bolt, guard bar etc of F.I. confirming to Fe 290, Gde-E-165 complete all as specified and directed.200Kg
1514S & F pre-painted Trapezoidal profile galvalume aluminium zinc coating steel sheet 0.50mm thick (base metal thickness) of any colour having tensile strength of 550 Mpa minimum yield strength conforming to IS - 513 (1994) coated with hot dip alloy of 55% aluminium + 43.50%Zinc +1.50% silicon and finished with resin coat ( of thickness not less than 35 micron) on both surface @150gm/sqm of coating (total both surfaces) of approved colour as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap whereever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided whereever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. \nNote : The colour of sheet shall be approved by GE.1470Sqm
1615Ditto all as per Item No. 14 above but for plain sheet as in roof ridges/clading to wall etc. complete all as specified and directed.100Sqm
1716Roughening surface of old concrete floor by picking, sweeping, clean and washing down with water to remove dust etc all as specified and directed.270Sqm
1817M & L for machine cut Kota stone slab flooring 20-25mm thick over and including 20mm thick screed bed in cement mortar 1:6 laid and bedded jointed cement slurry mixed with pigment to match to shade of the slab incuding grinding, mirror polishing complete all as specified and directed.270Sqm
1918M & L for machine cut Kota stone slab 20-25mm thick as in dado, riser of steps, skirting, and including 15mm thick rendering as backing coat of kota stone CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match to shade of the slab incuding cutting grinding mirror polishing complete all as specified and directed.12Sqm
2019Taking down cement plaster of any description in any position incl racking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed.240Sqm
2120M & L for rendering in CM 1:4 on walls 15mm thick on fair faces of brick work or concrete surface finished the surface even and smooth with out using extra cement complete all as specified and directed.200Sqm
2221M & L for rendering 15mm thick on other than fair faces in CM 1:6 finished the surface even and and smooth with out using extra cement complete all as specified.60Sqm
2322M & L for 2nd classs hard wood plain solid straight chowkats and frame wrought, framed double rebated on the solid put together with glue, pinned at joints and fixed in position complete all as specified and directed.0.25Cum
2423S & F of 35mm thick IInd class hardwood framed panelled shutters (two number of panels)with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, as per IS 1003 kiln seasoned and chemically presure treated all as specified and directed.6Sqm
2524M & L for 30mm thick 2nd class hard wood glased shutter divided into square with plain,chamfered or rounded mitered and rebated sash bar any numbers, fitted with cut and mitred beads for securing glass etc and fitted to chowkat all as specified and directed.10Sqm
2625M & L for 35mm thick 2nd class hard wood wire gauged shutter open rebated prepered to receive glass, gauze etc with out sash bars chamfered or rounded fitted with cut and mitred beads for security glass etc size of members of shutters as specified and fitted to chowkat complete all as specified and directed.10Sqm
2726M & L for cement concrete type C2 (1:3:6) using 40mm graded aggr 75mm thick for plinth, path, make surface fair and even w/o using extra cement etc protection complete all as specified and directed.40Sqm
2827M & L for preparation of old treated surfaces of wall by washing, rubbing down and applying 1mm thick wall care putty finish surface even and smooth and two coats distemper oil emulsion complete all as specified and directed.\n240Sqm
2928M & L for preparation of old treated surfaces by brooming down or steel wire brushing, and applying two coats of cement base paint over a coat of primer on complete all as specified and directed.\n120Sqm
3029M & L for two coats of cement base paint over a coats of primer on new surface including preparation of surface complete all as specified and directed.200Sqm
3130M & L for applying two coats of distemper over one coat of primer including preparation of new plastered surface of wall after applying wall care putty 1mm thick to finish surface even and fare complete all as specified and directed.60Sqm
3231Hacking out old broken glass (any thickness size quality and discription) for metal frame including punching, drilling out old glazing pins / spring clips and providing new ones complete all as specified and directed.7Sqm
3332S & F sheet glass of 3mm thick ordinary quality glass and glazing with oil putty in square n exec 0.5 Sqm in each pane complete all as specified and directed.12Sqm
3433S & F stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.16Sqm
3534S & F in repairs stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.12Sqm
3635S & F mild steel But hinges of medium weight and fixed 100mm complete all as specified and direceted.18Each
3736S & F mild steel But hinges of meedium weight and fixed 75mm complete all as specified and direceted.36Each
3837S & F aluminium anodised barrel tower bolt 200 mm extruded section complete all as specified and direceted.\n24Each
3938S & F aluminium anodised barrel tower bolt 100 mm extruded section all as specified and directed.\n36Each
4039S & F aluminum anodised sliding door bolt 250mm fixing with bolt and sliding bolt of extuded section complete all as specified and direceted.14Each
4140S & F Extruded aluminum handles fabricated type 150mm complete all as specified and direceted.16Each
4241S & F Extruded aluminum handles fabricated type 125mm complete all as specified and direceted.36Each
4342M & L for preparation of new wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and direceted.\n\n40Sqm
4443M & L for preparation of new steel surface and applying two coats of synthetic enamel paint over a coat of primer red oxide zinc chrome including preperation surfaces complete all as specified and direceted.60Sqm
4544M & L for preparation of old painted surface of any description not otherwise described, wood and wood based surfaces, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and direceted.30Sqm
4645M & L for preparation of old painted surfaces of any description steel and iron surfaces, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and direceted.\n16Sqm
4746M & L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete complete all as specified and direceted.20Sqm
4847Taking down carefully copper/aluminium point wiring including fittings and fixtures such as switches, ceiling roses, pendants, sockets, etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and direceted.114Per Point
4948M & L for point wiring complete with 1.5 Sqmm single core multi- stranded copper conductor PVC insulated and unsheathed fire retardant cable 1100 volts grade, IS-694 (ISI marked) drawn through in concealed PVC conduit and all necessary fittings accessories fixed on walls/ceiling etc including shunk type pressed steel terminal boxes with 3.00 mm thick insulated laminated sheet/hylem top covers on walls/box including 1.5 Sqmm PVC insulated unsheathed fire retardant cable 1100 volts grade with multi stranded copper conductors earth continuity conductor to common earth and connected to earth dolly for the following :-
5048.01One light point/ fan/ exhaust fan point/bell point controlled by one way switch of 5/6 Amps74Point
5148.02One 5/6 amps socket outlet on the independent board.20Point
5248.03One 5/6 amps socket outlet on same board with other switch18Point
5349Supply and Fix Switch piano, flush type, white finish, 5/6 amps, single pole, one way complete all as specified and directed.92Each
5450Supply and Fix Socket outlet 5 pin, 5/6 amps and flush type, non shutters, non inter locking type, complete all as specified and directed.20Each
5551Supply and Fix ceiling rose, surface bakelite, AC, 220/240 volts, 3 terminals, complete all as specified and directed.54Each
5652Supply and Fixing in replacement of 18 Watt LED tube light fitting single tube, box type surface mounted, (1x18 Watt) complete , spring loaded rotar type lamp holder, connector block etc. with LED tube rod 18W, prewired including making necessary electrical connection with three core copper flexible wire of 0.50 Sqmm from ceiling rose to tube light fitting complete all as specified and directed. \n22Each
5753S & F in replacement stepped type electronic fan regulator flush type 230 V single phase 120 watt on existing laminated sheet as required complete all as specified and directed.26Each
5854S & F in replacement sheet metal enclosure double door for DB, TPN 4 way with 200 amps rated bus bar, 415 volts, suitable for housing MCB`s complete all as specified and directed.1Each
5955S & F in replacement sheet metal enclosure double door for DB, SPN 4 way with 200 amps rated bus bar, 240 volts, suitable for housing MCB`s complete all as specified and directed.3Each
6056S & F in replacement MCB SPN, 240 volts, 6 to 40 amps, 10KA ‘C’ series complete all as specified and directed.3Each
6157S & F in replacement MCB TPN, 415 volts, 40 amps, 10KA ‘C’ series complete all as specified and directed.1Each
6258S & F in replacement MCB SP, 240 volts, 6 to 30 amp, 10 KA ‘C’ series complete all as specified and directed.18Each
6359S & F lamp holder PVC/polycarbonate type with metal ring and back plate suitable for batten fittings.20Each
6460Supply and Fix in replacement of LED security light luminaire comprising of epoxy powder coated housing enclosed with glass cover in frame 45 W and making electric connection with 2 core 1.5 sqmm PVC copper stranded conductor cable complete all as directed.\n6Each
6561S & F sub main wiring in replacement with two single run of 6 Sqmm single core unsheathed PVC insulated fire retardant (FR) cable, 1100 volts grade multi stranded copper conductor drawn through in & including PVC conduit of 25 mm or higher dia including all necessary conduit accessories, surface type including one run of 4 Sqmm stranded copper conductor PVC insulated fire retardant (FR) cable as earth wire connected to common earth dolly complete all as specified and directed.\nNote: Two runs of 6Sqmm and one run of 4Sqmm and one run of PVC conduit shall be measured as one unit.23RM
6662Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for laying of cable and getting out for soft / loose soil complete all as specified and directed.11Cum
6763Removing excavated material n exc 50m and depositing at a level n.exc 1.5M above ground complete all as specified and directed.6Cum
6864Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25 m in sof/loose soil complete all as specified and directed.5Cum
6965M & L for sand cushioning for protection of PVC / XLPE cable, firstly spread the sand into trench at least 8 cm height and then lay the cable over sand and cover with sand at least 15 cm height and punned manulay complete as specified and as directed.\n Note : The punned thickness of sand will be measured only.4Cum
7066Supply and laying burnt bricks sub class B of old size laid dry in trenches for cable protection complete as specified and as directed.0.4Per 1000 Nos
7167Supply and Fix in replacement GI tubing light grade of size 40mm for protection of cable, and bracket for in comming and out going of cable in trenches/on pole complete as specified and as directed.21Rm
7268Supply, laying and testing in replacement of XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade and confirming to IS 7098 Part -I with stranded aluminium conductor of size 16.0 sq mm 4 core complete as specified and as directed.50Rm
7369M & L for Earthing in replacement complete with GI earth plate electrode 600x600x6.0mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth wire 4 mm dia by means of bolts , Nuts, checknuts and washers of galvanised iron or steel and panel /DB/ Pole complete including PCC masonry pit of 300 x 300 x300 mm interior diamentions in PCC 1:2:4 type 'B1' RCC Cover with GI frame , charcoal and common salt 15 cm in layers all arround the earthplate, 15 mm dia GI pipe light grade for protection of GI wire and 20 mm dia GI pipe light grade for watering purpose and a funnel with wire mess should be provided on top of watering pipe comp all as specified as per Electrical plate No 5 of SSR Part-I 2009 including testing after completion and test result should be less than five ohm complete as specified and as directed.1Each Job

AI Tender Summary

OUR REF NO 27010776
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 27 Lakhs
LAST DATE 08-03-2021
Authority
Authority Name Military Engineer Services
Work Description Special Repair To Bldg No T 10 And Replacement Of Corrugated Asbestos Sheets To Galvanium Sheet Of Otm Bldg No T 15 And T 37 At Mil Stn Banbasa Under Ge Mes Pithoragarh
Basic Detail
Tender No 8353/BAN/E8
Bidding Type Tender
Location
City Banbasa
State Uttarakhand
Key Dates
Publish Date 15 Feb 2021
Submission Date 08 Mar 2021
Open Date 10 Mar 2021
Finance
Tender Value 27 Lakhs
Tender Fee 500
EMD 54000
Exemption Not Available
Document List
Tendernotice_1.pdf
580D6400-627E-496D-BFEA-F21A846BC1CB.html
Tender8353.pdf
BOQ_471835.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 15, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 08, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 10, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

580D6400-627E-496D-BFEA-F21A846BC1CB.html

pdf

Tender8353.pdf

xls

BOQ_471835.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders