Provision Of Exhaust System At Ships Gallery , Ceiling Fans Against Ber Ceiling Fans , Water Cooler With Purification System ( Ro Uv ) At Various Naval Units In Chennai Under Age ( I ) Navy Chennai, CHENNAI-Tamil Nadu

Military Engineer Services-MES has published Provision Of Exhaust System At Ships Gallery , Ceiling Fans Against Ber Ceiling Fans , Water Cooler With Purification System ( Ro Uv ) At Various Naval Units In Chennai Under Age ( I ) Navy Chennai. Submission Date for this Tender is 12-03-2021. Water Cooler Tenders in CHENNAI Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

27004179
Corrigendum : Provision Of Exhaust System At Ships Gallery , Ceiling Fans Against Ber Ceiling Fans , Water Cooler With Purification System ( Ro Uv ) At Various Naval Units In Chennai Under Age ( I ) Navy Chennai
Open Tender
Indian
Tamil Nadu
CHENNAI
12-03-2021

Tender Details

Provision Of Exhaust System At Ships Gallery , Ceiling Fans Against Ber Ceiling Fans , Water Cooler With Purification System ( Ro Uv ) At Various Naval Units In Chennai Under Age ( I ) Navy Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 11800.0 /-
Tender Value
INR 5.90 Lakhs /-

BOQ Items

Name of Work: PROVISION OF EXHAUST SYSTEM AT SHIPS GALLERY, CEILING FANS AGAINST BER CEILING FANS, WATER COOLER WITH PURIFICATION SYSTEM (RO&UV) AT VARIOUS NAVAL UNITS IN CHENNAI UNDER AGE(I) NAVY CHENNAI (Tender ID - 2021_MES_421820_1 )
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Taking down old unserviceable copper/aluminium point wiring (light,fan, socket or power) including old unserviceable fixture and fittings complete etc removing the materials for taking credit and making good the disturbed surface of wall/floor etc. complete all as specified and directed by Engineer in Charge. 12 Per \nPoint
2 2 Point wiring with 1.5 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 1.5 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 2 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed for one 3 pin socket outlet 5 amps socket on independent board 4 Point
3 3 All as per item No. 2 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on independent board with 2.5 sqmm cable as earthing conductor complete all as specified and directed by Engineer in Charge. 8 Point
4 4 S&F in repair Modular switch 1 way 5A, 1 Module including taking down old unserviceable switch and removing the material for taking credit complete all as specified and directed by Engineer in Charge. 4 Each
5 5 S&F in repair Modular switch 1 way 16A, 1 Module including taking down old unserviceable switch and removing the material for taking credit complete all as specified and directed by Engineer in Charge. 8 Each
6 6 S&F in repair Modular Socket 5A-2/3 pin combined 2 Module including taking down old unserviceable socket and removing the material for taking credit complete all as specified and directed by Engineer in Charge. 4 Each
7 7 S&F in repair Modular Socket 5A / 15A - 2 / 3 pin combined 2 Module including taking down old unserviceable socket and removing the material for taking credit complete all as specified and directed by Engineer in Charge. 8 Each
8 8 S&F Modular White cover plate with frame, 3 Module including taking down old unserviceable modular cover plate and removing the material for taking credit complete all as specified and directed by Engineer in Charge. 12 Each
9 9 S&F Modular metal flush box 3 module including taking down old unserviceable metal box removing the material for taking credit and making good the disturbed surface of wall complete all as specified and directed by Engineer in Charge. 7 Each
10 10 Taking down carefully old unserviceable submain wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc. complete all as specified and directed by Engineer in Charge. 105 RM
11 11 M&L for sub main wiring/ with four runs single core 16 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 16 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 40 mm dia/PVC casing capping 32 mm including conduit accessories complete all as specified and directed by Engineer in Charge. \nNote: Five runs of 16 Sqmm cable and one run of 40 mm conduit / casing capping will be measured as one unit length. 60 RM
12 12 M&L for wiring for circuit of size 2 x 4.0 sq.mm along with earth wire of size 1 x 4 sq.mm, Single Core, PVC insulated copper coductor (FRLS) Cable in surface / recessed PVC Conduit complete all as specified and directed by Engineer in Charge. 45 RM
13 13 S&F sheet metal enclosure powder coated double door for distribution board, VTPN 4 way DB including, disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and directed by Engineer in Charge. 1 Each
14 14 S&F MCB SP 5 A to 32 A , B curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and directed by Engineer in Charge.\n 9 Each
15 15 S&F MCB TP 50A / 63 A , C curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and directed by Engineer in Charge.\n 1 Each
16 16 Supply & Replace for Isolatar Four Pole, 50 A/ 63A including , disconnecting electric connections, dismantling from position unserviceable Isolator for taking into credit complete all as specified and directed by Engineer in Charge.\n 1 Each
17 17 Fabrication Supply and installation of 3 HP kitchen centrifugal blower unit with following specification complete all as specified and directed by Engineer in Charge.\n(a) Motor 3HP/1440 RPM/ 3 Phase(body made up of MS) \n(b) Provison of ducts of size 525 x 345 mm and length 2000mm to meet the requirements \n(c) GI Oil filter of required size -6 Nos\n(d) DOL starter 3HP with proper wiring for connection on required basis \n 1 Each Job
18 18 S&F Ceiling fan 1200 mm or 48” sweep BLDC motor complete all as specified and directed by Engineer in Charge.\nMake Orient Model: Atomiser or equivalent in Usha/Bajaj/Crompton 61 Each
19 19 S&F Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer in Charge.\n 61 Each
20 20 S&F and testing of water cooler with inbuilt RO purifier of storage capacity 80 ltrs and capacity of 40 ltrs/hr single phase power supply ensuring IS 10500:2012 standard for drinking water complete all as specified and directed by Engineer in Charge.\nMakes: Voltas/ Bluestar 1 Each
21 21 S&F voltage stabilizer for automatic operation,single phase naturally air cooled indoor type and desigend for input variation between 135 V to 280 V with output voltage stabilized at 230 V and of capacity 1.0 KVA complete all as specified and directed by Engineer in Charge.\nMake : V-guard Model VG 100 or equivalent as approved 1 Each
22 22 M&L for Point wiring with 4 sqmm (Nominal area) unsheathed multi-stranded copper conductor PVC insulated cable 1100 volts grade single core for one 3 pin socket outlet 15 Amps on independent board drawn into and including non-metallic rigid PVC conduit of 20 mm dia/ PVC Casing capping along with 4 sqmm unsheathed multi stranded copper conductor cable PVC insulated 1100 volts grade as earth continuity conductor connected to common earth dolly fixed to wall/ ceiling roof with and including 2 mm thick MS sheet fabricated terminal boxes flush mounted for mounting the switches, sockets, fan regulator etc as required with 3mm thick laminated hylum sheet top cover all as specified and directed 1 Each
23 23 S&F Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp modular type controlled by one switch complete all as specified and directed by Engineer in Charge. 1 Each
24 24 S&F MCB SP 25 A, B curve complete all as specified and directed by Engineer in Charge.\n 1 Each
25 25 S&F 20 mm bore Tubes, 'Medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.\n 15 Each
26 26 S&F 15 mm bore Tubes, 'Medium grade' galvanised,with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.\n 10 Each
27 27 S&F ISI mark 15mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.\n 10 Each
28 28 S&F ISI mark 20mm bore Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.\n 10 Each
29 29 M&L for providing, cement concrete 1:2:4 type B1 using 20 mm graded agregate as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer in Charge.\n 0.5 Cum
30 30 M&L for for 100 mm thick screed bed or bedding layer in CM 1:3 for laying floor finishes complete all as specified and directed by Engineer in Charge.\n 1.5 Sqm
31 31 M&L for non skid coloured ceramic tiles 7 to 8mm thick (Square/ rectangular) area of each tiles exceeding .11 sqm but not exceeding .18 sqm in floors etc set and jointed in neat cement and pointed in white or coloured cement to match complete all as specified and directed by Engineer in Charge.\n 1.5 Sqm
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail