Repair To Flooring , Plastering , Joinery , Plumbing And Sanitory Fitting At Or Md Accn At Fafa Complex , Repair And Maint Of Office Complex Area , Repair/Replacement Of Flooring , Sanitary Fittings , Joinery , Roof Under Ge ( East ) , Mathura, GE (EAST), MATHURA-Uttar Pradesh

Military Engineer Services-MES has published Repair To Flooring , Plastering , Joinery , Plumbing And Sanitory Fitting At Or Md Accn At Fafa Complex , Repair And Maint Of Office Complex Area , Repair/Replacement Of Flooring , Sanitary Fittings , Joinery , Roof Under Ge ( East ) , Mathura. Submission Date for this Tender is 13-03-2021. Civil Work Tenders in GE (EAST), MATHURA Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

27003282
Corrigendum : Repair To Flooring , Plastering , Joinery , Plumbing And Sanitory Fitting At Or Md Accn At Fafa Complex , Repair And Maint Of Office Complex Area , Repair/Replacement Of Flooring , Sanitary Fittings , Joinery , Roof Under Ge ( East ) , Mathura
National Competitive Bid
Indian
Uttar Pradesh
GE (EAST), MATHURA
13-03-2021

Tender Details

Repair To Flooring , Plastering , Joinery , Plumbing And Sanitory Fitting At Or Md Accn At Fafa Complex , Repair And Maint Of Office Complex Area , Repair/Replacement Of Flooring , Sanitary Fittings , Joinery , Roof Under Ge ( East ) , Mathura

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Feb-2021 AMENDMENT Date 06-03-2021
2 01-Mar-2021 REVISION OF BOQ BOQ 06-03-2021
3 06-Mar-2021 AMENDMENT Other 06-03-2021
4 06-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-03-2021

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR TO FLOORING, PLASTERING, JOINERY, PLUMBING AND SANITORY FITTING AT OR MD ACCN AT FAFA COMPLEX, REPAIR AND MAINT OF OFFICE COMPLEX AREA, REPAIR/REPLACEMENT OF FLOORING, SANITARY FITTINGS, JOINERY, ROOF UNDER GE (EAST), MATHURA
Sl. No. Item Description Item Code / Make Qty Units
1 1 Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints,hacking for key, scrubbing down with water, etc. 955 Sqm
2 2 M&L for 15mm thick plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement. 200 Sqm
3 3 M&L for rendering 10 mm thick in CM 1:4 on ceiling surfaces and finished surface even & smooth all as specified. 100 Sqm
4 4 M&L rendering 15mm thick (10mm + 5mm) plaster on fair face of brick work in CM 1:4 and surface finished even and fair by mixing liquid water proofing compound as per manufacturers instructions complete. \nNote :- Liquid WPC shall be measured & paid seprately under relevant item of this BOQ. 375 Sqm
5 5 M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. 75 Sqm
6 6 M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper over a coat of Alkali resistant primer over a coat of wall care putty not less than 1mm thick complete all as specified and as directed. 200 Sqm
7 7 M&L for preparation of newly plastered surface of ceiling and applying two coat of white wash complete all as specified and directed. 100 Sqm
8 8 S&F in repairs 25mm dia stainless steel pipe of grade 304 as in curtain rod including pair of decorative stainless steel brackets and knobs fixed to walls with screws as per sample approved by GE. 250 RM
9 9 M&L for preparing old plastered surfaces of walls/ceilings and applying one coat of weather proof acrylic exterior paint (100% Acrylic) with spray machine, spray hard to reached area to achieve excellent application using limited manpower including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.\nNote :- \n(i) Weather proof acrylic exterior paint shall be applied machincally by latest machine such as trucare Graco or equivalent having minimum pressure of 3300 PSI. 2850 Sqm
10 10 M&L for preparation of old plastered surfaces of wall and applying two coats of oil bound distemper with spray machine, spray hard to reached area to achieve excellent application using limited manpower complete all as specified and directed.\nNote :- \n(i) Oil bound distemper shall be applied machincally by latest machine such as trucare Graco or equivalent having minimum pressure of 3300 PSI. 500 Sqm
11 11 M&L for preparation of old decorated plastered surfaces of walls and applying two coat of plastic emulsion paint with spray machine, spray hard to reached area to achieve excellent application using limited manpower over wall care putty not less than 1mm thick complete all as specified and directed. \nNote :- Plastic emulsion paint shall be applied machincally by latest machine such as trucare Graco or euivalent having minimum presure of 3300 PSI. 165 Sqm
12 12 M&L for preparing old plastered surfaces of walls/ceilings and applying two coat of weather proof acrylic exterior paint (100% Acrylic) over a coat of self primer with spray machine, spray hard to reached area to achieve excellent application using limited manpower including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.\nNote :- \n(i) Taking down of existing teratment with trucare wall sander L01/H-01 or equivalent machine having mechanical vacum mechanisum with not less than 1500RPM. \n(ii) Weather proof acrylic exterior paint shall be applied machincally by latest machine such as trucare Graco or equivalent having minimum pressure of 3300 PSI. 300 Sqm
13 13 M&L for preparing old plastered surface of walls and applying one coats of white wash complete all as specified. 2000 Sqm
14 14 M&L for preparing old plastered surface of ceiling and applying one coats of white wash complete all as specified. 400 Sqm
15 15 M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed. 500 Sqm
16 16 M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. 200 Sqm
17 17 M&L for preparation of old steel surfaces any description over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified. 400 Sqm
18 18 M&L for preparation of old steel surfaces any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified. 100 Sqm
19 19 S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or suitable bolts and nuts in steel windows. 100 Sqm
20 20 S&F in repair 3mm thick frosted glass ordinary quality and glazing with oil putty in Sqm n.exc 0.50 Sqm in each pane complete. 25 Sqm
21 21 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises 1166 Sqm
22 22 Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level). 50.6 Cum
23 23 M&L for providing 25mm thick M-15 grade (Nominal mix) using 20mm graded stone aggregate as in floor finish complete. 100 Sqm
24 24 S&F coloured, non skid ceramic tiles 7 to 8 mm thick (square/ rectangular ) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm ,in floors etc . set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl screed bed or bedding layer of mortar 15 mm thick for laying floor finished use CM 1:4 all as specified. 200 Sqm
25 25 All as per item No 22 here-in-before but as in skirting/dado over 10mm thick cement plaster in CM 1:3 as in backing coat as specified and directed by Engr-in-Charge. 16 Sqm
26 26 M&L for Glazed ceramic tiles in vertical surface 300x200x7mm/450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing coat of cement mortar in 1:3 complete all as specified. 480 Sqm
27 27 S&F vitreous china wash hand basin,white, flat back size 580x450 mm excluding taps, waste chain & plug & porcelein stopper but including brackets 32 mm bore waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement cutting for and pinning in ends of brackets all as specified and directed. 5 Each
28 28 S&F in repairs PVC valveless syphonic action type flushing cistern (Low or high level) of 10 litre capacity, white/coloured with inlet ball valve, float handle including fixing brackets and 32mm bore PVC flush pipe etc complete all as specified and directed. 10 Each
29 29 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 145 RM
30 30 Supplying & fixing to walls and ceiling 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed 75 RM
31 31 Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc for 15mm dia complete all as specified and directed. 20 RM
32 32 Taking up or down 20mm dia steel tubing and connections including disconnection of fitting and cleaning for refixing where required complete all as specified and direcred. 130 RM
33 33 Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc for 20mm dia complete all as specified and directed. 10 RM
34 34 Supplying & fixing to walls and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 120 RM
35 35 M&L for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps,cills, sunshades, shelves,lintels,etc; and cutting chases for concealed water tubing etc, and making, cutting not exc10 cm girth. 110 RM
36 36 S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. 5 Each
37 37 S&F 15 mm bore fancy type Chromium plated stop valve cast copper alloy scap screwed one ends to iron pipe or for unions and other end by PVC connection all as specified. 20 Each
38 38 S&F in repairs 15mm bore pillar taps fancy type cast copper alloy with capestan heads chromium plated screwed down high pressure with hot & cold with long screwed shanks and fly nuts all as specified and directed. 15 Each
39 39 S&F in repair 15mm bore fancy type bib taps chromium plated cast copper alloy with crutch or butter fly handle screwed down, screwed for iron pipe complete. 25 Each
40 40 S&F in repairs Brass chromium plated shower rose 75mm size fixed to GI tubing and to Shower complete. 20 Each
41 41 S&F in repairs bathroom cabinet mirror (of approved pattern) of size 450mmx350mm regular size with mirror and PVC shelves complete all as specified and directed by Engineer-in-Charge. 10 Each
42 42 S&F 500 litre capacity triple layer ISI Marked rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)hoisted and fixed in position including making inlet/oulet connection and fitting tank connection complete all as specified and as directed. 3 Each
43 43 S&F in repair 20 mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete. (Minimum weight 20mm-210gms). 25 Each
44 44 S&F 110 mm dia PVC (SWR) pipes type 'A' single socketed in any length with rubber ring joints laid in trenches. 11 RM
45 45 S&F 75 mm dia PVC (SWR) pipes single type 'A' socketed in any length with rubber ring joints laid in trenches. 11 RM
46 46 S&F PVC (SWR) 110 mm dia bends any radious all as specified and directed. 5 Each
47 47 S&F PVC (SWR) 75 mm dia bends any radious all as specified and directed. 5 Each
48 48 S&F in repair PVC (SWR) branch piece, single (single Y) equal or unequal for 110mm dia pipe complete all as specified and directed. 5 Each
49 49 S&F in repair PVC (SWR) branch piece, single (single Y) equal or unequal for 75mm dia pipe complete all as specified and directed. 5 Each
50 50 S&F in repair 110 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified. 5 Each
51 51 S&F in repair 75 mm dia PVC (SWR) junction single, (Single T) equal or unequal complete all as specified. 5 Each
52 52 Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each 21 Each
53 53 Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each 16 Each
54 54 Taking down shutters of any description exc 1.00 Sqm and n. exc 2.00 Sqm each. 11 Each
55 55 S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position 2 Each
56 56 S&F 105x60 mm Pressed steel frames made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete, as specified, supplied and fixed all as specified and as directed. 97.2 RM
57 57 S&F 125x60 mm Pressed steel frames made out of 1.25mm steel sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete, as specified, supplied and fixed all as specified and as directed. 41.2 RM
58 58 Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete M-15 grade (Nominal mix) using 20mm graded stone aggregate as required depth of embedded portion of holdfast or lugsmeasured from the face of jamb into the wall - exc. halfbrick but n exc. one brick 66 Each
59 59 M&L for cement concrete M-10 grade (Nominal Mix) using 12.50mm graded stone aggregate for filling in pressed steel door frames all as specified and directed. 1.93 Cum
60 60 S&F 40 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides. 30.6 Sqm
61 61 S&F 35mm thick second class HW glazed and gauged skeleton shutters open rebeted and prepared to receive glass, guaze etc (without sash bar) edges of framing plain chamfered or rounded fitted with cut and beads for securing glass, gauge etc size of shutters as specified in SSR Part-I section & clause 8.20(a). 31 Sqm
62 62 M&L for preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engr-in-charge. 109.2 Sqm
63 63 M&L for preparation of new steel surfaces over 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamal paint over a coat of red oxide primer complete. 143.2 Sqm
64 64 M&L for prepration of new primed steel surfaces, exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chromate primer all as specified and as directed by Engineer-In-Charge. 14.29 Sqm
65 65 S&F 125 mm long extruded aluminium alloy handles, fabricated type anodized complete. 64 Each
66 66 S&F for 100 mm aluminium anodised barrel tower bolts of extruded section and fixed. 64 Each
67 67 S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed. 27 Each
68 68 Supply and fix Stainless steel wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples 9.9 Sqm
69 69 Supply and fix 150mm length, floor door stopper of brass body, fixe in repairs complete all as specified and directed. 22 Each
70 70 S&F100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed . 42 Each
71 71 S&F solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforcement with MS square tube supplying and fixing in opening as per specification & sketch shown in sketch 8 of SSR part II. 78 RM
72 72 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck indie with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fittied in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. 29 Sqm
73 73 S&F aluminium powder coated window sliding type (3 rack) with frame size 100x35x1.2mm and shutter 39.40x17.70x1.2mm with two glass shutter & one wiremesh shutter including necessary jointing, cleats glazing, clips, rubber packing powder coated aluminium snap beading, screws with 4mm thick plain float glass of 0.56mm dia stainless steel wiremesh fitting etc complete all as specified and directed. 7.2 Sqm
74 74 S&F aluminium louvered ventilators of section size 100mmx25mmx1.50mm including frosted glass fixed in half protion & adjustable type louvers in another hald and stainless steel wire mesh fixed type on outside frame etc. including taking down existing steel ventilator all as directed by Engr-in-charge 6 Sqm
75 75 Dismantling Mangalore pattern of similar tiles in roofing complete all as specified. 600 Sqm
76 76 Dismantling of battens for Mangalore tiles of any size including tilling fillets exc 15cm. 600 Sqm
77 77 Dismantling timber scantling 40sq cm and over in section, in any position. 2 Cum
78 78 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W. 4000 Kg
79 79 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in roof covering with self tapping screws complete. 600 Sqm
80 80 S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as per IS 15965: 2012 in cladding to wall with self tapping screws complete. 40 Sqm
81 81 S&F wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc and similar work confirming to Fe-290 Gde E-165. 600 Kg
82 82 M&L for providing cement concrete M-15 grade (Nominal mix) using 12.5 mm graded stone aggregate as in roof kerbs or mud stops, rounded or chamfered on edges complete. 2.5 Cum
83 83 Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets. 530 Sqm
84 84 Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605 mm x 605 mm in true horizontal level, hot dipped galvanized steel sections (galvanized @ 120 grams/sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24 mm X 38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200 mm x 600 mm and secondary cross “T” of length 600 mm and size 24 mm X 28 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200 mm X 600 mm panel to form grids of 600 mm X 600 mm and wall angle of size 24 mm X 24 mm X 0.4 mm. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 mm X 37 mm X 25 mm X 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 mm X 30 mm X 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications and as directed by Engineer-in-charge. 300 Sqm
85 85 M&L 4mm thick designer non-asbestos fibre cement building board having fire resistance & mosture resistance properly.\nMake :- Everest, fixed on aluminium grid with screws complete all as specified and directed. 300 Sqm
86 86 5mm thick printed PVC sheet in strip & channel feathered at the edges for fixing on solid PVC wall linning, insulated PVC wall lining complete all as specified. 200 Sqm
87 87 S&F PVC beading at the edges top and bottom of PVC wall lining complete all as specified. 100 RM
88 88 S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and webof 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. 30 Sqm
89 89 M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions 30 Sqm
90 90 M&L for preparation of new ceiling surfaces and applying two coats of oil bound distemper over a coat of wall care putty not less than 1mm thick over and including one coat of primer complete all as specified. 30 Sqm
91 91 Demolition of brick work or stone boulder masonary built in cement mortar including all quoins arches pillars etc. but excluding ashlar facing dressed stone work and precast concrete articles. 28 Cum
92 92 M&L for brickwork with fly ash bricks (old size) straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified. 28 Cum
93 93 M&L for rendering 10 mm thick in CM 1:6 on ceiling surfaces and finished surface even & smooth all as specified. 280 Sqm
94 94 M&L for providing damp proof layer in two coats of acrylic polymer coating consisting of 1 part of acrylic polymer liquid mixed with 2 parts of cementious powder applying at the rate of 1.40sqm/Kg of mix per coat. Second coat should be applied after 4-6hrs of first coat, 5 days curing is to be carried out to the surface before providion plastering. \nNote: Make of the material Smart Care damp block 2K of Asian paints or equivalent from Dr Fixing, STP, CICA etc as approved. 150 Sqm
95 95 Supply only liquid water proofing compound. 7.4 Litre
96 96 M&L for sanding the surface to make it smooth and ready for painting and applying one coat of Deco solvent based primer over the surface applying 2nd coat of acrylic wall putty to make the surface smooth, after 4-6 hrs drying time and sanding the surface, one coat of deco solvent based primer shouldbe applied over the acrylic putty to fill the pores, one step of sanding should be done before the application of 1st coast of Royale Base coat and 2nd coat of Royale luxuty emulsion diluting with water as per recommended procedure. After drying time of 3-4hrs applying one coat of co polymer based. 60 Sqm
97 97 Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area n. exc 1.5 Sqm each, complete all as specified and directed.\n 12 Each
98 98 Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area n.exc 1.5 Sqm each but n.exc. 4sqm complete all as specified and directed. 10 Each
99 99 S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides. 20 Sqm
100 100 S&F 12mm thick toughened glass shutters (openable type), with clear glass including diamond polishing all hardware fittings detailed as under, fixed in position as per manufacture instruction complete. 6 Sqm
101 101 S&F stainless steel top patch (Cat No. EPF-701) 01 Set 3 Pair
102 102 S&F stainless steel top pivote (Cat No. EPF-712) 01 Set 3 Pair
103 103 S&F stainless steel bottom patch (Cat No. EPF-702) 01 Set 3 Pair
104 104 S&F glass to wall stainless steel lock (Cat No. EPF-799) 01 No 3 Pair
105 105 S&F stainless steel floor door spring (Cat No. FH-ECO-842) 01 No 3 Each
106 106 S&F stainless steel handle 300mm size (Cat No. ESBH-011)-02 Nos for each shutter. \nNote:- For item No. 102 to 107 the Cat No. mentioned are for hardware fitting are of make ENOX.n 4 Each
107 107 S&F in repair 5mm thick sheet glass ordinary quality and glazing with oil putty in Sqm n.exc 0.50 Sqm in each pane complete. 18 Sqm
108 108 Providing and fixing factory made UPVC white colour sliding window three track made of extruded profiles with wall thickness of 2.3mm (0.2mm) window profile with hollow section with muoti chamber. Frame (88mmx52mm) sliding sash (42mmx67mm). Sliding mesh sash (42mm x57mm) slide interlock (One vertical length in each shutters) (45.5mmx28mm) glazing bead (24.5mmx16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing harddware and drainage of water etc making arrangement for fising of hardware. EPDM gasket 1.2 1-0.2mm thick galvanized steel frame (30mmx18mm) 2 Nos sliding sash (30mmx18mm) sliding mesh sash (26mmx10mm) profile to be inserted in required profile frame will be fixed to wall with 8mmx100mm long fasteners. Hardware touch lock of zonc alloyed (white powder coated) steel roller system stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.\nNote:- The unit rate quoted by contractor excludes cost of glass and included all other connected accessories. Net opening will be measured for payment purpose) area n.ex 2.00sqm each. 25 Sqm
109 109 S&F for 200 mm aluminium anodised barrel tower bolts of extruded section and fixed. 10 Each
110 110 S&F 150 mm long extruded aluminium alloy handles, fabricated type anodized complete. 20 Each
111 111 S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 400 Kg
112 112 S&F Vitrified ceramic coloured light shade tiles 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with over and including 15 mm thick screed bed or bedding in layer in cement mortar 1:4, all as directed. 470 Sqm
113 113 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar. 0.3 Ten Sqm
114 114 M&L for 20 mm thick Granite black work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cement mortar 1:4 complete. 5 Sqm
115 115 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations. 1 RM
116 116 M&L for Machine cut machined polished kota stone slab flooring 18-20mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with mechanical scrubber over and including 15 mm thick screed bed or bedding layer in cement mortar 1:3 complete all as specified and directed. 100 Sqm
117 117 Supplying and laying of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified. 50 RM
118 118 S&F in repair bib cock 15 mm cast copper alloy with screwed down, screwed for iron pipe or for brass ferrule and fixed.\nMake:Jaquar FUS-29037 12 Each
119 119 S&F in repair 15 mm size angular cock, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed both end for iron pipes complete. 20 Each
120 120 S&F 15 mm bore PVC connection with PTMT nuts of length 450 mm. 6 Each
121 121 S&F in repair single lever extended basin mixture height 85mm without popup waste system with 450mm long braided hoses complete all as specified. Make: FUS-CHR-29023B 6 Each
122 122 S&F 32mm dia PVC waste pipe of 750mm length complete including taking down old unserviceable. 6 Each
123 123 S&F Vitreous China wash down water closet pan (pedestal pattern), white including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified and directed. 4 Each
124 124 S&F in repairs colour european type combination pattern WC casket type christinna with mounted flushing cistern PVC connections, seat cover and jointed to sewage pipe. \nMake: Cera Cat No. S1013119 or equivalent approved makes given under list of makes. 1 Each
125 125 S&F in repairs 2way bib cock with wall flange 15mm dia including fixing to pipe complete all as specified and as directed. \nMake: Jaquar Cat No. FUS-29041 5 Each
126 126 S&F in repairs Hand faucet ABS body 1.2m long flexible tube and wall hook including fixing complete all as specivied and as directed. \nMake:- Jaquar Cat No. ALD-CHR-593N. 5 Each
127 127 S&F repairs toilet paper roll holder, \nMake :- Jaquar Cat part No CAN-1151 N or equivalent. 5 Each
128 128 S&F repairs vitreous china wash basin, white, flat back, size 630x450mm including brackets, waste coupling complete all as specified and as directed. 5 Each
129 129 S&F 600 x 450 mm bevelled edges mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers. 5 Each
130 130 S&F in repairs Stainless steel sink with draining board made out of 1.0 mm thick sheet for kitchen incl waste pipe CI cantilever brackets and waste coupling etc complete and making good to the side of wall,connecting union to pipe, including bedding in CM to dwarf wall. Overall size 495mmx420mm bowl and size 410x330x160mm. 2 Each
131 131 S&F in repairs sheet glass assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromeum plated bracket guard and railing 60 cm long complete all as specified and directed. 5 Each
132 132 S&F in repair brass chromium plated tutular tower rail 20mm dia including brackets fixed to wall complete all as specified. 5 RM
133 133 S&F in repair Corner glass shelf with bracket fixed to wall complete all as specified. \nMake:- Jaquar Cat No. CAN-1173. 4 RM
134 134 S&F in repair PVC (SWR) floor trap plain with grating including jointing with solvent cement dia of out let 75 mm including stainless grating fixed complete all as specified and as directed. 8 Each
135 135 S&F in repair PVC (SWR) pipes 75mm single socket, in any length with rubber ring joints laid in trenches or in floors. 24 RM
136 136 S&F PVC (SWR) pipes 100mm single socketed, in any length with rubber ring joints laid in trenches or in floors. 4 RM
137 137 S&F 1000 litre capacity triple layer ISI Marked rotational moulded polyethylene water storage tank (cylindrical vertical with closed top)hoisted and fixed in position including making inlet/oulet connection and fitting tank connection complete all as specified and as directed. 4 Each
138 138 M & L for 50 mm thick plain cement concrete 1:3:6, type C1 (using 20 mm graded stone aggregate) as in plinth protection surfaces finished even and smooth without using extra cement including filling the joints by bitumen and sand mixed in the ratio 1:4 by weight complete all as directed. 35 Sqm
139 139 Demolition of reinforced roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified. 0.15 Cum
140 140 M&L for steel formwork to soffits of suspended slab such as roof slabs, flor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) for flat rough finished surfaces. 2 Sqm
141 141 M&L for providing reinforced cement concrete M-25 grade (Design Mix) in slabs supproted on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified. 0.15 Cum
142 142 M&L for steel reinforcement of TMT bars (FE-500 Grade) 10 mm dia and over cut to length and bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips all as specified and directed. 50 Kg
143 143 M & L for treatment of soil under existing floors using chemical emulsion in water of one percent Chlorpyrifos 20 EC at the rate of one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed. 180 Sqm
144 144 M&L for providing 100 mm thick cement concrete M-7.5 grade (Nominal Mix) using 40 mm graded stone aggregate as in sub base all as specified and as directed. 309 Sqm
145 145 M&L for 25 mm thick sand filling undder floors or in foundations uncluding watering and consolidation 0.1 Cum
146 146 M&L for Rubber Moulded glossy finish machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade built with grey cement and pigment. 150 Sqm
147 147 M&L chequered cement concrete tiles with gray cement and pigment 30cm x 30 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floor over & incl 15mm thick screed bed CM 1:6. 159 Sqm
148 148 Taking down aluminium/copper point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, flourescent tube light fittings etc, removing materials to store for keeping in safe custody or for taking credit and making good to the disturbed surfaces of walls, ceilings and floors etc complete all as direct. \nNote: Credit of aboe item should be incl i the point as per credit schedule. 318 Per Point
149 149 Taking down carefully by Submain wiring/ service connection of any type complete all as directed by Engineer-in-Charge.\n 260 RM
150 150 M&L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed FRLS cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia medium grade) and its all accessories complete concealed in wall / roof incl cutting & chases( making good all to the disturbed surfaces as per existing) etc including earth wire of PVC insulated FRLS copper conductor multistranded of 1.5 Sqmm size in green colour complete all as specified in current SSR Part-I & II & directed by the Engineer-in-Charge, as described below:-
151 150.01 One light point controlled by one way switch 5 amp complete. 165 Per Point
152 150.02 One ceiling fan point controlled by one way switch 5 Amp and one regulator complete. 31 Per Point
153 150.03 One exhaust fan point controlled by one way switch 5 Amp complete. 12 Per Point
154 150.04 One 3 pin 5 Amp socket point controlled by one switch on same board. 16 Per Point
155 150.05 One 3 pin 5 Amps socket point controlled by one switch on independent board. 46 Per Point
156 150.06 One bell point controlled by one push button on independent board. 10 Per Point
157 150.07 One light point controlled by two way switches 5 Amp complete. 2 Per Point
158 151 All as per item No. 150 but for 3 pin / 5 pin 16 Amps sockets outlet with 4 Sqmm PVC insulated & unsheathed (FRLS) copper conductor cable independent complete all as specified and as directed . 36 Per Point
159 152 M&L for submain wiring with Two runs of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie all conforming to IS specification complete.\nNote :- Two run of 4 Sqmm, one run of 4 sqmm earth wire and one run of PVC conduit shall be measured as one unit length. 130 RM
160 153 M&L for submain wiring with Two runs of single core 6 sqmm for main wire and one run of single core 6 sqmm as earth wire of stranded copper conductor FRLS PVC insulated unsheathed cables conforming to IS : 694 drawn through and including concealed in wall rigid medium duty unplasticised PVC conduit conforming to IS : 9537 ( Part-3) and ISI marked not less than 20 mm dia and accessorie all conforming to IS specification complete.\nNote :- Two run of 6 Sqmm, one run of 6 sqmm earth wire and one run of PVC conduit shall be measured as one unit length. 130 RM
161 154 Supply and Fixing ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified. 166 Each
162 155 Supply and Fixing Modular switch 6 Amps single pole one-way, 1 Module complete all as specified. 270 Each
163 156 Supply and Fixing Modular switch 6 Amps single pole two-way, 1 Module complete all as specified. \n 2 Each
164 157 Supply and Fixing Modular bell push switch 6 Amps with indicator single pole one way, 1 Module complete all as specified. 12 Each
165 158 Supply and Fixing Modular switch 16 Amp single pole one way, 2 Module all as specified. 34 Each
166 159 Supply and Fixing bell multi music type 230 volts complete with connections all as specified and directed. 18 Each
167 160 Supply and Fixing Modular fan regulator electronic step type 120watt, 2 Module complete all as specified. 31 Each
168 161 Supply and Fixing lamp holder, PVC polycarbonate type with back plate suitable for batten fittings complete all as specified. 32 Each
169 162 Supply and Fixing Modular socket 2-in-1, 5 pins 6 Amps , combined 2 Module complete all as specified. 62 Each
170 163 Supply and Fixing Modular socket 2-in-1, 5 pins 16 Amps , combined 2 Module complete all as specified. 34 Each
171 164 Supply and Fixing switch piano flush type 5 Amps single pole one way complete all as specified. 30 Each
172 165 Supply and Fixing switch piano flush type 15 Amps single pole one way complete all as specified. 20 Each
173 166 Supply and Fixing socket outlet flush type 2-in-1, 3 pins 5 Amp multipurpose complete all as specified. 30 Each
174 167 Supply and Fixing socket outlet flush type 2-in-1, 3 and 5 pins 15 Amp multipurpose complete all as specified. 20 Each
175 168 Supply and Fixing fan regulator electronic step type & flush type complete all as specified. 17 Each
176 169 Supply and Fixing bell Push switch flush type 6 Amp single pole one way complete all as specified. 10 Each
177 170 Supply & fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 20 watt LED Tube fitting with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. \nMake: - Havells, Cat Part No: LUMILINEBS20WLED 865 SPC WH or equivalent to CG/Bajaj/Philips 124 Each
178 171 Supply & fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 9 watt LED Tube fitting mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. \nMake: - Havells, Cat Part No: LUMILINEBS9WLED 865 SPC WH or equivalent to CG/Bajaj/Philips 18 Each
179 172 Supply & Fixing indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 10 watt LED Tube fitting mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 5700K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. \nMake: - Havells, Cat Part No: INTEGRANEOSURFA CEDLS10WLED875S) or equivalent to CG/Bajaj/Philips 6 Each
180 173 Supply and Fixing decorative wall light fitting made up of Polycarbonate with outer cover shape having glove/mars suitable for B-22 base holder including with 10 Watt LED lamp complete with all accessories and including connection complete all as specified and directed. \nMake: Havells Cat Part No MARS Shape LHFOFWE1TZ1W0129405) or equivalent to Philips/Bajaj/CG. 14 Each
181 174 Supply and Fixing environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and directed. \nMake:- Havells ordering Cat Part No. HEXAFT10WLED857SSY MBOPC or equivalent in Bajaj/Philips/Wipro/CG. 14 Each
182 175 Supply and Fixing LED 10W lamp suitable for normal holder (Base Cap B22) complete all as specified. 46 Each
183 176 Taking down old unserviceable existing DB / enclosures any size and any type as iorn sheet scrap including MCB any type / size and making good disturbed surface / wall as per existing complete all as specified and directed. 41 Each
184 177 S&F MCB distribution board, SPN 8 Way, double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified. 20 Each
185 178 Supply & fixing MCB SP 6 - 32 Amps, 'B' series, bracking cap10KA complete all as specified and directed. 64 Each
186 179 Supply & fix MCB SPN 40 Amps, 'C' series, bracking cap10KA, 240V complete all as specified and directed. 15 Each
187 180 Supply & fix MCB SPN 30-40 Amps, 'B' series, 10KA, 240V complete all as specified and directed. 3 Each
188 181 Supply and fix SP enclosure with a two pin and earth plug and socket complete with SP MCB of rating 20 Amps, 240 Volts complete with all conction as directed. 8 Each
189 182 Supply and install of 30W LED building security light fitting with lens & driver, powder coated pressure dia cast aluminium, top opening and maintenance with heat resistance toughened glass, built in short circuit protection, over voltage protection and surge protection, IP-65 proction with luminaire efficiency of greater than 80 Lumen/Watt, Colour rendering (CRI) of 70 and co-related colour temperature (CCT) of 5700K (±500K). The luminaire should have 10KV surg protection, PF 0.9 and total harmonic ddistortion of THD 10%, voltage range of 140-280V including all connections complete all as specified. \nMake of fitting:- Havells (as per Cat Part No. ENDURACITYLITEPLAT PLUSSL30WLED757SASYBOPC) or equivalent in CG/Bajaj/Philips/C&S (Meeting all the above specification). \nMake of LED: CREE/Nichia/Orram/Lumiled /Bridgelux. 4 Each
190 183 M&L for building security light bracket made out of 40mm dia light grade GI pipe of 1.2m length bent to required shape suitable for fixing street light fitting on steel tubular pole including two Nos clamps made out 40mmx6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer complete all as directed taking down old unserviceable bracket as scrap any size/description. 2 Each
191 184 Supply and Installation with all connections of LCD display AC single phase electronic KWH Meter with box, Two wire, tamper proof, static meter of class 1.0, 240V, 50Hz 10A-60A conforming to relevant IEC standards complete all as directed by Engineer-in-Charge and including taking down old unserviceable electric/electronic meter. \nMake: Secure/L&T/Schiedent. 10 Each
192 185 Taking down the ceiling fan of any sweep carefully from its installed position, dismantling complete with down rod, repair/replacement of unserviceable parts (like as bearing, capacitor, burnt winding, rubber wheel bush etc) and cleaning of all dust, applying grease for bearings, reassembligh the fan and blades, painting of fans and down rod with synthetic enamel white paint by spraying single coat including filling cavities with filler, writing MES No with black paint, and keeping a side safely and hanging/refixing in position and connecting up including provision of 3 core twisted flexible copper conductor cable of 0.75sqmm from ceiling rose to connector of fan and testing on completion complete all as specified and directed. \nNote:- The spare parts (like as bearing, capacitor, rubber wheel push, fan winding etc) required shall be measured and paid separately under relevant items. 30 Each Job
193 186 Taking down the exhaust fan of any sweep carefully from its installed position, dismantling complete with down rod, repair/replacement of unserviceable parts (like as bearing, capacitor, burnt winding, rubber wheel bush etc) and cleaning of all dust, applying grease for bearings, reassembligh the fan and blades, painting of fans and down rod with synthetic enamel white paint by spraying with single coat including filling cavities with filler, writing MES No with black paint, and keeping a side safely and hanging/refixing in position and connecting up including provision of 3 core twisted flexible copper conductor cable of 0.75sqmm from ceiling rose to connector of fan and testing on completion complete all as specified and directed. \nNote:- The spare parts (like as bearing, capacitor, rubber wheel push, fan winding etc) required shall be measured and paid separately under relevant items. 30 Each Job
194 187 Supply and Fix in repair ball bearing suitable for ceiling fan/exhaust fan of any type complete. 30 Each
195 188 Supply and Fix inrepair capacitors 2.5 MFD/3.5 MFD suitable for all types of fans complete all as directed.\nMake: - Usha, Universal, Epcos. 30 Each
196 189 Supply and Fix in repair rubber wheel bush and with GI bolt, nut, washer and split pin complete all as specified and directed. 30 Each
197 190 Dismantling of worn out/burnt out windings of ceiling fan and re-winding the motor of ceiling fan with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete including replacement of split/safety pins, locking nut, check nut and testing for original and consumption complete for following sizes:
198 190.01 1200/1400 mm sweep. 17 Each
199 191 Dismantling of worn out/burnt out windings of exhaust fan any type and re-winding the motor with super enamelled copper wire of existing gauge, varnishing with approved quality insulating varnish complete and testing for original and consumption complete for following sizes:
200 191.01 200/225/250 mm sweep. 10 Each
201 191.02 300 mm sweep. 10 Each
202 192 Taking out the electric geyser of capacity 25 Ltrs carefully from its installed position by disconnecting inlet and outlet water pipes, dismantling the unit and replacing the defective heating element and resolve all leakage problems from geyser and painting with one coat of synthetic enamel paint and writing MES No and refixing in its original position and reconnecting the inlet/outlet water pipes an dtesting on completin complete all as directed by Engr-in-Charge. \nNote:- The spare parts like Heating element, hot & cold flexible water pipe line, Thermostate required shall be measured and paid separately under relevant items as supply only.
203 192.01 Supply only electric heating element 1.5 KW ISI marked complete, 240 Volt AC. \nMake- Bajaj/ Recold/Daspass/Theeta/Power Pack or as per sample / installed at site 10 Each
204 192.02 Supply only thermostate switch CO-THERMO Type TSE-GA3 Safety 230 volt, ISI marked complete, suitable for Geyser 25 Ltr. Make/Danfoss or equivalent /installed at site 10 Each
205 192.03 Supply only hot water / cold water pipe 600mm long as per existing type complete all as specified and directed. 10 Set
206 193 Supply and fixing for 28 Watt LED decorative recessed mounted Panel light made up of powder coated CRCA sheet suitable for Lumen efficancy > 110 Lm / Watt , CCT 6500K, operating Voltage 140V to 270 Volt , short circuit protection , surge protection, complete suitable for 600mm x 600mm modular / POP / Gypsum ceiling complete all as specified. \nMake : Havells (Ref Cat No For Light : VENUSNEOHE2X2R18-42WLED857MOD UGR<19 & For Driver : LEDDRIVER36V28WS) its equivalent in Bajaj / Crompton / Philips / Bajaj 50 Each
207 194 Supply & fixing indoor decorative ultra slim surface /Wall mounted LED light fitting 1x 14 watt suitable for mirror light,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,>100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Enginee-in-Charge. \nMake:Philips as per Cat Part No 38105 14-Watt or equivalent to CG/Bajaj / Havells 16 Each
208 195 Supply and fixing environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and as directed. \nMake: Havells ordering cat part No HEXAFT10WLED 857SSY MBOPC or equivalent in Bajaj/ Philips/ Wipro /CG\n\n\n\n 16 Each
209 196 Supply and fixing decorative modern Pendant LED light fitting with shed cover including extension cable and Smart Wi-Fi LED bulb B22 9-Watt compatible with WiZ Connected ,on / off, dimming features complete suitable for office table pendent light with complete fitting all as specified. 16 Each
210 197 Supply & fixing Decorative modern & energy saving bathroom wall light fitting with LED 12 watt bulb ( Base Cap B22) ,chrome colour , metal housing material,moisture resistant complete with all accessories and including connection complete all as specified and as directed.\nMake : Philips as per Cat Part No Philips 32035 /11 / 66 or equivalent to Havells / Bajaj / CG . 10 Each
211 198 Supply & fixing Decorative modern & energy saving wall light fitting ,compatible with B22 bulb base type incl 9-Watt LED lamp , white colour metal housing material complete with all accessories and including connection complete all as specified and as directed Make : Philips as per Cat Part No Philips Grace 9-Watt or equivalent to Havells / Bajaj / CG . 30 Each
212 199 Supply & fixing Decorative modern & energy saving wall light fitting incl with 2 x 7.5 watt LED lamp , white colour, aluminum housing material complete with all accessories and including connection complete all as specified and as directed.\nMake : Philips as per Cat Part No 69069 2 * 7.5-Watt LED (27K) Ledino White Wall Lamp or equivalent to Havells / Bajaj / CG . 15 Each
213 200 Supply and fix LED 9 W lamp suitable for normal holder( Base Cap B22) complete all as specified. 10 Each
214 201 Supply and fix Smart Wi-Fi LED bulb B22 9-Watt compatible with WiZ Connected ,on / off, dimming features and warm to cool light options, timing schedule option(16 Million Colors + Warm White /Neutral White /White + Dimmable + Pre-set modes) complete all as specified. \nMake : Philips as per Cat Part No 929002317513or equivalent to Havells, Wipro / Bajaj / CG / Syska 8 Each
215 202 Supply and install of 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of = 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF = 0.9 and total harmonic distortion of THD = 10%, voltage range of 140-280V including all connections complete all as specified. \nMake of fitting : Havells (as per Cat Part No : ENDURACITYLITEPLAT PLUSSL30WLED757SASYBOPC) or equivalent in Crompton Greaves/ Bajaj/Philips / C&S (meeting all the above specification). 15 Each
216 203 M&L for building security light bracket made out of 40mm dia light grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer complete all as directed taking down old unserviceable bracket as scrap any size / description. 15 Each
217 204 S&F MCB distribution board, SPN 4 Way, double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail, cable ties for cable management, 240 V, complete all as specified. 3 Each
218 205 Supply & fix MCB SPN 63 Amps,' C' series , 10KA, 240V complete all as specified and directed. \nMake : Havells or equivalent of Legrand/L&T C&S/ ABB. 5 Each
219 206 Supply and fix DP enclosure with a two pin and earth plug and socket complete with DP MCB of rating 20 Amps, 240 Volts complete with all conction as directed.\nMake : Havells or equivalent of Legrand /L&T/ C&S 10 Each
220 207 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core, laid in trenches / duct / fixing on walls / poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole / Main Panel Box and testing , incl dismantling of old unserviceable cable any size & type complete all as specified and directed.\n 300 RM
221 208 Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, laid in trenches / duct / fixing on walls / poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole / Main Panel Box and testing , incl dismantling of old unserviceable cable any size & type complete all as specified and directed. 100 RM
222 209 Excavatin in trenches n.exc 1.5m in depth and n.exc 1.5m wide for laying of cables and getting out in soft/loose soil all as specified and as directed by Engr-In-Charge. 76 Cum
223 210 Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified. 8 Cum
224 211 Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested complete all as specified. 68 Cum
225 212 M&L for HDPE Double Wall Corrugated pipe of size 40mm outer dia and 32mm inner dia confirming to IS:14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. laid in trenches/ fixed to wall with suitable clamps for cable protection complete all as specified and directed. Make : Gemini/Stiple. 350 RM
226 213 S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder painted with Copper bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting with following MCCB & MCBs with connections :-. (Make Havells /Legrand/ABB / C&S)\n(i) MCCB 100 Amps, 4 Pole, 16 KA - 01 Nos (Havells C P No: IHLGNF0100 #)\n(ii) MCB SPN 63 Amps, 10KA - 04 Nos\nNote : -MCB & MCB /MCCB DBs shall be of same make. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items. 4 Each
227 214 Supply and fix exhaust fan 200mm sweep , 1350RPM, Air delivery 520 m3 / hrs, non metallic type alongwith louvers / front grill complete suitable to work on AC, single phase, 230 Volts, 1350 RPM, 50 Hz supply and including connecting up with twin core twisted flexible copper conductor cable of suitable size 0.75 Sqmm including taking down of old unserviceable rusted fan any type .\nMake : Havells -Model Ventil Air - DX White and equivalent of Bajaj / Crompton greves / Orient 8 Each
228 215 Supply and fix BLDC (brushless direct current) ceiling fan min 1200 mm sweep with advance Energy Saving, Aerodynamic rust free ABS (Acrylonitrile Butadiene Styrene )blades with RF Remote control white in colour, 3 Wind Modes: Natural, Sleep and Norm, air flow capacity 260 Cubic Metres per Minute , 220 volt 50 Hz complete with canopy, down rod. Fan blade, complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking down of old unserviceable rusted fan any type complete all as specified and directed by Enginee-in-Charge.\nMake : Usha (Model USHA Heleous) or equivalent to Havells / Bajaj /Khetan / Orient 10 Each
229 216 Supply and fixing of Desert cooler electric driven single phase 230 Volts, plastic / PVC body,3-Side Cooling Pads with propeller cooler fan having nominal Air flow capacity 5000 Cum/hr., 3 speed control,fan sweep size not less 450 mm, High Impact Polystyrene (HIP) blades, submersible pump and max. Electrical power consumption of 200 - 225 watts, sump water tank capacity not less than 70 Ltrs incl Trolley complete with site installation and including taking down of old unserviceable rusted cooler any type all as specified & directed by Engineer-in-Charge\nMake: Symphony / CLASSIC,Cool Tech , ATLAS, ALPINE SUPER, ORISON,Sugandha etc. or equivalent. 10 Each
230 217 Supply and fix Instant Electric Water Heater (White)storage type of 03 litres capacity, 5 star rating, 3KW rated power,rust & shock proof ABS Outer Body, Color Changing LED Indicator, incoloy glass coated heating element, thermostat cutout temperature (ºC), adjustable knob for temp setting ,vertical type , to operate on single phase, 220-240 volts, 50 Hz AC supply & complete with all safety controls including provision of suitable bolts, nuts, washers and grouting on walls and making good the disturbed surfaces to match with the existing sufaces and provision of suitable PVC flexible pipe for hot & cold connection, chromium plated brass check nuts for cold & hot water lines and one No. non return valve of suitable size complete installation with testing including taking down of old unserviceable rusted storage heater any type all as specified and directed by Engineer-in-Charge. 2 Each