Road Transport and Highways Private Organizations Closing in 0 days TDR #26995232

Urgent Repairs And Replacement Of Defective Light Fixtures In Vyttila Mobility Hub Bus Terminal Electrical Works Repair

Issued by Private Organizations · VYTTILA HUB BUS TERMINAL, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
23 Feb 2021
0 days left
EMD
6700
Bank guarantee accepted
Document Fee
1060
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
VYTTILA HUB BUS TERMINAL → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Urgent Repairs And Replacement Of Defective Light Fixtures In Vyttila Mobility Hub Bus Terminal Electrical Works Repair

BOQ

Work Name:Electrical 2020-21: Urgent repairs and replacement of defective Light Fixtures in the Vyttila Mobility Hub Bus Terminal .
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11ElectrificationBI01010001010000000000000515BI0100001113
21.00190.15.4.4 : Supply Conveyance, installation, testing and commissioning of 100W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI01000011148each
31.00290.15.4.6 : Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI010000111512each
41.00390.15.4.7 : Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI01000011169each
51.00490.15.4.9 : Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI01000011176each
61.00590.6.5.9 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.BI01010001010000000000000515BI0100001118150metre
71.00690.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).BI01010001010000000000000515BI01000011197point
81.00790.2.1.3 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).BI01010001010000000000000515BI01000011203point
91.00890.3.19.3 : Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as requiredBI01010001010000000000000515BI010000112130each
101.00990.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as requiredBI01010001010000000000000515BI010000112225metre
111.011.17.2 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mmBI01010001010000000000000515BI010000112315metre
121.0111.17.11 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mmBI01010001010000000000000515BI010000112410metre
131.0121.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.BI01010001010000000000000515BI01000011253each
141.013od1049725/2020_2021 : Supply and providing 9w LED Bulb on existing batten lightBI01010001010000000000000515BI01000011263each

AI Tender Summary

OUR REF NO 26995232
AUTHORITY Private Organizations
TENDER VALUE Ref. Documents
LAST DATE 23-02-2021
Authority
Authority Name Vyttila Mobility Hub Society
Work Description Urgent Repairs And Replacement Of Defective Light Fixtures In Vyttila Mobility Hub Bus Terminal Electrical Works Repair
Basic Detail
Tender No 01/VMHS/A1/72/2021
Bidding Type Tender
Location
City VYTTILA HUB BUS TERMINAL
State Kerala
Key Dates
Publish Date 16 Feb 2021
Submission Date 23 Feb 2021
Open Date 25 Feb 2021
Finance
Tender Value Ref. Documents
Tender Fee 1060
EMD 6700
Exemption Not Available
Document List
declaration.pdf
BOQ_586812.xls
Tendernotice_1.pdf
NIT1.pdf
A45E5BD7-FEFF-456F-9833-DC7FE3B70B37.html
EPAY.pdf
preliminary-converted.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 16, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 23, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 25, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

declaration.pdf

xls

BOQ_586812.xls

pdf

Tendernotice_1.pdf

pdf

NIT1.pdf

html

A45E5BD7-FEFF-456F-9833-DC7FE3B70B37.html

pdf

EPAY.pdf

pdf

preliminary-converted.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders