Military Engineer Services-MES has published Repair/Replacement Of Unserviceable Led Type Security Light , Perimeter Fencing Light , Bulk Head Fittings And Hpsv/Mv Type Ii Led Type Fittings And Other Connected Works At Af Stn Thoise Under Ge ( Af ) Thoise. Submission Date for this Tender is 27-02-2021. LED Light Tenders in GARRISON ENGINEER (AF) THOISE Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 18-Feb-2021 | CORRIGENDUM NO.1 DATED 18 FEB 2021 | Other | 20-02-2021 |
2 | 20-Feb-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 27-02-2021 |
Name of Work : REPAIR/REPLACEMENT OF UNSERVICEABLE LED TYPE SECURITY LIGHT, PERIMETER FENCING LIGHT , BULK HEAD FITTINGS AND HPSV/MV TYPE II LED TYPE FITTINGS AND OTHER CONNECTED WORKS AT AF STN THOISE UNDER GE (AF) THOISE | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Taking down LT cable of size as mentioned in item no. 4.00 to 8.00 complete all as specified and as directed. | 900 | RM | |
2 | 2 | Relaying of existing un-reinforced precast concrete cable covers class LV, type-1, flat, of size 250mm x 150 mm x 40mm complete all as specified and as directed. | 1700 | Each | |
3 | 3 | M&L for Un-reinforced precast, factory made, concrete cable covers, class LV, type-1, flat, of size 250mm x 150 mm x 40mm complete all as specified and as directed. | 2667 | Each | |
4 | 4 | Supply and Laying XLPE insulated LT cable, armoured, heavy duty PVC sheathed electrical cable with Aluminium conductor, 1100 Volts grade of size 35 Sqmm, 3.5 core complete all as specified and as directed. | 145 | RM | |
5 | 5 | Supply and Laying XLPE insulated LT cable, armoured, heavy duty PVC sheathed electrical cable with Aluminium conductor, 1100 Volts grade of size 50 Sqmm, 3.5 core complete all as specified and as directed. | 155 | RM | |
6 | 6 | Supply and Laying XLPE insulated LT cable, armoured, heavy duty PVC sheathed electrical cable with Aluminium conductor, 1100 Volts grade of size 185 Sqmm, 3.5 core complete all as specified and as directed. | 260 | RM | |
7 | 7 | Supply and Laying XLPE insulated LT cable, armoured, heavy duty PVC sheathed electrical cable with Aluminium conductor, 1100 Volts grade of size 10 Sqmm, 4.0 core complete all as specified and as directed. | 190 | RM | |
8 | 8 | Supply and Laying XLPE insulated LT cable, armoured, heavy duty PVC sheathed electrical cable with Aluminium conductor, 1100 Volts grade of size 400 Sqmm, 3.5 core complete all as specified and as directed. | 150 | RM | |
9 | 9 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for laying underground cable and getting out in hard / dense soil complete all as specified and as directed. | 179 | Cum | |
10 | 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. | 95 | Cum | |
11 | 11 | Removal of surplus excavated material to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. | 79.8 | Cum | |
12 | 12 | Sand cushioning to underground cable with dry sand locally available 8cm thick before laying the cable and 15 cm above the cable, including stretching and testing of cable complete all as specified and as directed.\nNote: Thickness of 18 cm after punning shall be considered for payment purpose. | 51.5 | Cum | |
13 | 13 | M&L in repair for fabrication and installation of street light terminal box outdoor canopy type, size 40cm Height x 30 cm width x 12 cm thick size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut and bolt, and 8 Nos aluminium cable socket suitable for cable upto 185 sqmm, embedded in PCC foundation with 2 Nos angle iron leg 25x25mm 40 cm long as per sample, including taking down complete all as specified and as directed. | 110 | Each set | |
14 | 14 | M&L in replacement of copper conductor cable 2.50 sqmm PVC insulated two core unsheathed and PVC insulated for connection of LED street light fitting from existing source complete all as specified and as directed. | 1800 | RM | |
15 | 15 | M&L for replacement of MCB SPN, 32A, 'C' Curve and capacity 16kA with plastic enclosure complete all as specified and as directed. | 220 | Each | |
16 | 16 | S&F in replacement LED street light fittings (45 watts), with lamp fitted on security light pole connected with twin core wire dolly complete all as specified and as directed.\nMake:- cromption greaves / Bajaj/Philips | 215 | Each | |
17 | 17 | S&F in repair LED flood light 70W, IP 65 including bracket with clamps, nut bolts for mounting of light fitting complete all as specified and as directed.\nMake:- cromption greaves / Bajaj/Philips. \n | 16 | Each | |
18 | 18 | M&L in repair for providing for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6.0mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and including galvanised earth wire 4 mm dia upto 7.5 meter long by means of bolts, nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata, funnel with wire mesh and watering pipe(GI medium grade) 20mm dia, PCC pit with 50mm thick PCC cover etc. including testing on completion excluding GI protection pipe light grade for earthing lead complete all as specified and as directed. | 6 | Each | |
19 | 19 | S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and as directed. | 60 | RM | |
20 | 20 | M&L for applying two coats of synthetic enamel paint to 9 mtr long steel tubular swaged pole including marking alternate white and black strip painting upto 1.2 height and writing pole number on pole complete all as specified and as directed. | 200 | Each | |
21 | 21 | M&L for applying two coats of synthetic enamel paint to street light terminal box, 40cm height x 30cm wide x 12 cm depth including grouting angle with smoke gray paint complete all as specified and as directed. | 200 | Each | |
22 | 22 | M&L for repair/replacement of cover and locking arrangement of street light terminal box, 40cm height x 30cm wide x 12 cm depth complete all as specified and as directed. | 110 | Each | |
23 | 23 | Replacement of old unserviceable/damaged street light bracket made out of GI pipe 40 mm bore medium grade 1.5 m long, bend to shape required, fixed to pole / wall with MS clamps made out of 40x5 mm, 50 cm long incl nuts bolts of size 80x12 mm complete all as specified and as directed. | 110 | Each Job | |
24 | 24 | M&L for PVC conduit pipe 20mm dia medium grade for passing through wire between terminal box to street light with GI clamp complete all as specified and as directed. | 900 | RM | |
25 | 25 | Labour only for increasing height of Street light bracket minimum 40cm from the existing height complete all as specified and directed. \nNote : Contractor shall provide the labour for increasing height of existing security light by opening the GI Clamp and fix to the new position as per direction of the Engineer-in-Charge. | 100 | Each Job |