Provision Of Firefighting Sys For Amn Point Provn Of Firefighting Sys For Amn Point Dukhampani Under Ge 859 Ews
Tender Overview
Project Description
Provision Of Firefighting Sys For Amn Point Provn Of Firefighting Sys For Amn Point Dukhampani Under Ge 859 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Feb-2021 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-Mar-2021 |
BOQ
| Nature of Work : PROVN OF FIREFIGHTING SYS FOR AMN POINT DUKHAMPANI UNDER GE 859 EWS | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Construction of 01 x Fire Station in permanent Specification complete as shown in Drg No : CWE/ARCH/01. | 1 | Each | |
| 2 | 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation/sewage line and getting out in hard/dense soil complete all as specified and as directed. | 256.13 | Cum | |
| 3 | 3 | Returning filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm thick, in hard/dense soil complete all as specified and as directed. | 309.26 | Cum | |
| 4 | 4 | Removal of surplus soil of distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the stqrting point complete all as specified and directed. | 265.35 | Cum | |
| 5 | 5 | Material & labour for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in floor complete all as specified and as directed. | 17.55 | Cum | |
| 6 | 6 | M&L for RCC M-30 design mix as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under reamed piles and mass concrete complete all as specified and as directed. | 44.24 | Cum | |
| 7 | 7 | M&L for RCC M-30 design mix as in wassl, retaining walls, basement walls and the like, any thickness, above top of footings, including attached pilasters and buttresses complete all as specified and as directed. | 40.39 | Cum | |
| 8 | 8 | Supply and fix TMT bars 10mm dia and over (confirming to Fe-410-s or Fe-410-0) cut to length, bent to shape as required including cranking & binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. | 8625 | Kg | |
| 9 | 9 | Supply and fix TMT bars 6mm to 8mm dia and over (confirming to Fe-410-s or Fe-410-0) cut to length, bent to shape as required including cranking & binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed. | 343.7 | Kg | |
| 10 | 10 | Material & labour for rendering 10mm thick on concrete surface in cement mortar 1:3 mixed with water proofing compound @ 3% by weight of cement, finished fair and even with out using extra cement complete all as specified and directed (WPC shall be measured and paid for seperately) complete all as specified and as directed. | 285.7 | Sqm | |
| 11 | 11 | M&L for Formwork to flat rough finished surfaces of concrete walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc, vertical or to better, complete all as specified and as directed. | 163.3 | Sqm | |
| 12 | 12 | Supply only integrated water proofing compound ISI marked. | 72.65 | Kg | |
| 13 | 13 | M&L for 0.71mm thick plain aluminium sheeting, alloy 31000 H4 inserted (0.15m min) in between RCC joint of water tank to prevent the water leakage as water bar, complete all as specified and as directed. | 18.09 | Sqm | |
| 14 | 14 | M&L for point wiring with 1.5 sqmm (nominal area), two single core PVC insulated unsheathed 1100 volts grade, multi stranded copper conductor in and including PVC casing capping of adequate size with all fittingsand acessories including PVC board with top cover housing/mounting brackets switches sockets etc, including PVC insulated unsheathed single core multi stranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one way switch complete all as specified and as directed. | 3 | Per Point | |
| 15 | 15 | All as per item Ser No 16 above but one 5 amp socket outlet three pin controlled by one switch on independent board complete all as specified and as directed. | 1 | Per Point | |
| 16 | 16 | All as per Ser item No 16 above but 3 pin 15 Amps socket outlet independent board drawn from DB and including PVC insulated multi stranded copper conductor 4 Sqmm 1100 volts grade and wire earth continuity wire 2.5 Sqmm PVC insulated copper wire (Green) including PVC casing and capping complet all as specified and as directed. | 1 | Per Point | |
| 17 | 17 | S&F switch socket combination 2 in 1, 5 amps flush type 240 volts complete all as specified and as directed. | 1 | Each | |
| 18 | 18 | S&F switch socket combination multipurpose 15A flush type 5 in 1, 240 volts complete all as specified and as directed. | 1 | Each | |
| 19 | 19 | S&F switch piano flush type single pole one way 5 amp 240 volts, complete all as specified and as directed. | 4 | Each | |
| 20 | 20 | S&F ceiling rose surface bakelite, 65x50mm two to three terminals AC., 230 volts, complete all as specified and as directed. | 2 | Each | |
| 21 | 21 | S&F lamp holder insulated body PVC/polycarbonate type with back plate for batten fitting with one PVC block of complete all as specified and directed. | 1 | Each | |
| 22 | 22 | S&F LED lamp New Adore lED 15 W E 27 cool daylight code No LHLDERHEMK8X015, complete all as specified and as directed. Make : PHILIPS/equivalent of Bajaj/Crompton Greaves/Havells. | 1 | Each | |
| 23 | 23 | S&F sheet metal enclosure for DBs SPN 4 way, double door with 200 Amps rated bus bar fix on wall duly grouted in solid block wall or on PVC board in and including copper lugs thimble duly crimped for connection, complete all as specified and as directed. | 1 | Each | |
| 24 | 24 | S&F MCB SPN 40 Amp 240 Volts. | 1 | Each | |
| 25 | 25 | S&F MCB SPN 6 to 32 Amp 240 Volts. | 2 | Each | |
| 26 | 26 | S&F Regal batten for LED Tube universal batten for G-13 T8 lamps including making electric connectin from ceiling rose to tube light fitting, complete all as specified and as directed. Code No LHFYBYPNIA1W022 (Make : Havells/Bajaj/Philips/Crompton Greaves or equivalent). | 2 | Each | |
| 27 | 27 | S&F Photon Ultra Plus LED tubelight 18W (single side connection) Ultra bright LED ploycarbonate tubelight with 105 THD with very high efficacy suited for installation in existing T8 Tubelight with G13 lamp holders to give glare free light, complete all as specified and as directed. Code No : LHLDCLXNUL8X018 (Make : Havells/Najaj/Phillips/Crompton Greaves or equivalent). | 2 | Each | |
| 28 | 28 | S&F PVC rectangular block for mounting DB's with 3mm thick plastic laminated sheet cover of size 25cm x 20cm x 5cm, complete all as specified and as directed. | 1 | Each | |
| 29 | 29 | M&Lfor earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate protected by GI pipe 15mm bore (medium grade) and connected to main switch board or main control board as directed and as specified and shown in eletcical plate No 3 of SSR Part-I (2009) including necessary concrete pit in PCC (1:3:6) type C-1 pre-cast RCC (1:2:4) type B-1 cover slab 40cm x 40cm x 5cm reinforced with 8mm dia ar funnel wire mesh 20mm dia GI pipe medium grade for watering charcoal or coke and salt in alternate layers including necessary excavaion and earth work in any type of soil and testing complete all as directed by E-I-C. | 1 | Each | |
| 30 | 30 | M&L for sand cushioning under the cable for protection of cable from being broken due to external load complete all as specified and as directed. | 0.85 | Cum | |
| 31 | 31 | M&L for laying reinforced preast concrete cable cover, class HV, Type-1 flat, size 250mmx150mmx40mm, complete all as specified and as directed. | 70 | Nos | |
| 32 | 32 | Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 Sqmm 2 Core nominal cross section in service connections, complete all as specified and as directed. | 15 | RM | |
| 33 | 33 | S&F GI pipe light grade 25mm dia, ISI marked, or required length for protection of cables laid in trenches, fixed along with the pole complete including necessary MS clamps nuts, bolts and washers etc, complete all as specified and as directed. | 1.5 | RM | |
| 34 | 34 | S&F GI tubing (Heavy grade) with all fitting and accessories in trenches laid in floors or fixed to wall etc of size 100mm, complete all as specified and as directed. | 710 | RM | |
| 35 | 35 | S&F GI tubing (Heavy grade) with all fitting and accessories in trenches laid in floors or fixed to wall etc of size 80mm, complete all as specified and as directed. | 120 | RM | |
| 36 | 36 | Supply, installation & commissioning of Centrifugal pumping set IC driven engine driven supplied and installed tesging and commissioning of diesel engine driven pumbing set of capacity 10500 GPH suitable for 230 mtr head (inlet/outlet) including diesel engine of capacity of 120 WHP/127 HP coupled with the pump set with fitments accessories, NRV & foot valve of suitable size including making necessary connection and arrangement with existing water supply system and delivery line complete inclusive of starter and PCC foundation/channel base frame as per manufacturer's instruction. Diesel tank capacity of 400 ltrs calibrated with stand locking arrangement level indicator etc. battery 180 AH - 02 Nos and anti vibration pad 06 Nos complete all as specified and directed. Make : Kirloskar/KSB/Cummins. | 1 | Each Job | |
| 37 | 37 | Supply, installation & commissioning of Centrifugal pumping set IC driven engine driven supplied and installed tesging and commissioning of diesel engine driven pumbing set of capacity 40 HP suitable for 70 mtr head (inlet/outlet) including diesel engine of capacity of 40 WHP coupled with the pump set with fitments accessories, NRV & foot valve of suitable size including making necessary connection and arrangement with existing water supply system and delivery line complete inclusive of starter and PCC foundation / channel base frame as per manufacturers insctuctions. Diesel tank capacity for 400 ltrs calibrated with stand locking arrangement level indicator etc battery 180 AH 02 Nos and anti vibration pad 06 Nos complete all as specified and directed. Make : Kirloskar/KSB/Cummins. | 1 | Each Job | |
| 38 | 38 | S&F Cast Iron Sluice Valve class PN 1, 6 heavy duty long body type with brass spindle both ends flanged with holes, ISI marked aand provision of carbon steel nuts, bolts & washers rubber gasket etc with CI wheel fixed to water mains complete of size 100mm dia, complete all as specified and as directed. | 4 | Each | |
| 39 | 39 | S&F Fire Hydrant stand post 80mm dia GI/MS flanged type 2m height, complete all as specified and as directed. | 4 | Each | |
| 40 | 40 | S&F Fire Hydrant landing valve single headed out let of 63mm dia, complete all as specified and as directed. | 4 | Each | |
| 41 | 41 | S&F Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short, complete all as specified and as directed. | 4 | Each | |
| 42 | 42 | S&F 63mm dia15 Meter long RRl hose with male and female coupling, complete all as specified and as directed. | 4 | Each | |
| 43 | 43 | S&F hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard, complete all as specified and as directed. | 4 | Each | |
| 44 | 44 | M&L for cement concrete cast in situ 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in concrete pedestal for supporting the CI/GI pipes including necessary form work, complete all as specified and as directed. | 4 | Cum | |
| 45 | 45 | M&L for construction of brick masonry for valve chamber of size 1.00 x 1.00 mtr (internal size) with MS cover made out of 5mm thick MS plate with double hinges and frame made out of MS angle iron 40x40x5mm thick and locking arrangements, handle etc including necessary earth work and excvavation, PCC 1:4:8 Type D-2 in bedding, brick work in CM 1:6, 15mm thick plastering in CM 1:4 over brick wall, PCC 1:2:4 type B-1 as in coping over brick wall and applying two coats of synthetic enamel paint over a coat of redoxide primer on steel surfaces etc, complete all as specified and as directed. | 4 | Each | |
| 46 | 46 | S&F GI pipe medium grade 15mm dia, ISI marked of required length for protectionof cables laid in trenches, fixed along with the pole, including necessary MS clamps, nuts bolts and washers etc, complete all as specified and as directed. | 15 | RM | |
| 47 | 47 | S&F Gun-Metal globe or gate valves with iron wheel head, screwed both end for iron pipe and fixed of size 15mm incl taking down old complete all as specified and as directed. | 1 | Each | |
| 48 | 48 | S&F Ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed for 15mm dia pipe (minimum weight 15mm-142 gms/20mm-210 gms/25mm-455 gms/40mm-690 gms). | 1 | Each | |
| 49 | 49 | S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of size 500 Litre capacity, complete all as specified and as directed. | 1 | Each | |
| 50 | 50 | Rough excavation not exceeding 1.5 Mtr deep and getting out hard dense soil. | 1.8 | Cum | |
| 51 | 51 | Excavation over area not exceeding 1.5mtr deep and getting out hard dense soil. | 226.79 | Cum | |
| 52 | 52 | Add to items above for each additional 1.5m or part thereof in depth 3m”. | 96.3 | Cum | |
| 53 | 53 | M&L for layer of polythene sheet 300 micron thick providing over PCC and below base slab. | 150.13 | Sqm | |
| 54 | 54 | M&L for applying evenly a coat of blow bitumen grade 80/25 at the rate of 1.50 Kg per square metre over bituminous primer on the other face of wall | 131.14 | Sqm | |
| 55 | 55 | Formwork to fair finished surface sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any of foundation and plinth beams; and similar work; vertical or to batter | 19.8 | Sqm | |
| 56 | 56 | Formwork to fair finished surface of walls, retaining walls, abutments, parapets and staircase railing and similar work including attached pilasters, buttresses etc.; vertical or to better | 180.5 | Sqm | |
| 57 | 57 | M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, for Rungs | 124.74 | kg | |
| 58 | 58 | M&L for Black Japan paint for small articles such Rungs and similar articles, when unconnected with other painting or when painted in a different tint | 0.32 | 100 each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender