Repair Replacement Of Solar Street Lights High Mast Lights And Repairs Maint Of Earth Pits Mcb Mccbs With Enclosure Lt Cables At Af Stn Suryalanka As Per Boq And Tender Document, SURYALANKA-Andhra Pradesh

Military Engineer Services-MES has published Repair Replacement Of Solar Street Lights High Mast Lights And Repairs Maint Of Earth Pits Mcb Mccbs With Enclosure Lt Cables At Af Stn Suryalanka As Per Boq And Tender Document. Submission Date for this Tender is 09-03-2021. LT Cable Tenders in SURYALANKA Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26957338
Corrigendum : Repair Replacement Of Solar Street Lights High Mast Lights And Repairs Maint Of Earth Pits Mcb Mccbs With Enclosure Lt Cables At Af Stn Suryalanka As Per Boq And Tender Document
Open Tender
Indian
Andhra Pradesh
SURYALANKA
09-03-2021

Tender Details

Repair Replacement Of Solar Street Lights High Mast Lights And Repairs Maint Of Earth Pits Mcb Mccbs With Enclosure Lt Cables At Af Stn Suryalanka As Per Boq And Tender Document

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Feb-2021 Amendment to tender documents BOQ 02-03-2021
2 02-Mar-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-03-2021

Key Value

Document Fees
INR 300 /-
EMD
INR 8000.0 /-
Tender Value
INR 4 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT OF SOLAR STREET LIGHTS, HIGH MAST LIGHTS AND REPAIRS/MAINT OF EARTH PITS, MCB / MCCBs WITH ENCLOSURE, LT CABLES AT AF STN SURYALANAKA
Sl. No. Description of Item of Works Item Code / Make Approximate No. of Units Required UNIT
1 1 S&F in repair complete power circuit board for charge control current rating of 5/6 Amps for dusk dawn operation all as specified and as directed. 10 Each
2 2 Supply , install, test and commissioning 12W LED solar light fitting with IP-65 protection including all accessories and lamps with provision of battery low indication including taking down existing u/s LED/CFL fitting of wattage not more than 12 Watt and fixing on existing bracket incl making connection with existing cable all as specified and as directed. 17 Each
3 3 S&F in repair 2 core 2.5 sqmm PVC Insulated and Round Sheathed Multi Core Bright Annealed Bare Copper Conductor Heavy Duty Industrial Cable for Voltage Grade 1100 Volts conforming to IS: 694:1990 complete all as specified and as directed. 150 RM
4 4 S&F in repair PV solar panel of rating 75 watts Confirming to IEC61215 & IEC61730 certified with IP 65 rated along with connection termination box and connectors for cable entry complete all as specified and as directed. 10 Each
5 5 S&F in repair plastic battery box for housing the existing battery including the mounting structure with nuts and bolts for holding the battery box all as specified and as directed.\nNote: The cost of fixing existing battery in the new battery box shall deemed to be included in the quoted rate. 20 Each
6 6 Testing performance and topping up distilled water in solar light batteries to maintain necessary specific gravity with replacement of damaged battery lead clamp and worn out leads incl taking down and fixing batteries to its position complete all as specified and as directed.\nNote: The cost of transportation of battery to workshop and back as required shall deemed to be included in the quoted rate. 25 Each Job
7 7 S&F in repair 12 volts, DC, 42 Ah maintenance free valve regulated lead acid (VRLA) solar GEL battery along with copper connectors conforming to latest BIS / Indian standards complete all as specified and as directed. 5 Each
8 8 S&F in repair LED Flood light of 150 Watt Symmetrical illumination, along with Driver assembly as per OEM Specifications, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light and connecting up existing cable complete all as specified and as directed. \nMake:- Havells JETAARISFLS150WLED757PSYMLTG (OR) Crompton LHBN-150-CDL/60-M (or) equivalent model from any approved manufacturer from the LIST OF MANUFACTURER. 4 Each
9 9 Supply, laying, jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade , cross-sectional area 10 sqmm 2 core including necessary arrangement for fixing on wall, roof etc by using clamps, screws, etc including taking down old unsv service cable complete all as specified and directed 300 RM
10 10 Supply, laying, jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core including necessary arrangement for fixing on wall, roof etc by using clamps, screws, etc including taking down old unsv service cable complete all as specified and directed 100 RM
11 11 Supply, laying, jointing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core including necessary arrangement for fixing on wall, roof etc by using clamps, screws etc including taking down old unsv service cable complete all as specified and directed 50 RM
12 12 Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 10 Sqmm including taking down old unsv service cable complete all as specified 150 RM
13 13 Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m in wide for laying of cable, RCC Poles/stays and struts etc and getting out including trimming sides and forming bottom surface in soft/loose soil all as specified and as directed. 27 Cum
14 14 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified. 16 Cum
15 15 M&L for River sand cushioning using river sand for protection of underground cable providing with a layer 8 cm before laying and 15 cm after laying, complete all as specified and directed. \nNote:- Punned thickness of sand shall be measured. 8 Cum
16 16 Supply and laying common burnt bricks, sub class 'B' of size 230 x 115 x 75 mm in trenches over sand cushioning for cable protection complete all as specified and as directed. 847 Each
17 17 M&L Removing excavated material (soil) to a distance nexc 50m and depositing where directed at a level n exc. 1.5 m above the starting complete all as specified and directed 11 Cum
18 18 S&F MCCB 415 V, 16 KA, 4 Pole 125 A including taking down old burn out MCCB and making necessary arrangement for fixing the new one like cutting, welding, thimble of suitable size, nuts & bolts etc including provn of suitable size of MCCB enclosures made out of CRCA sheet 3.15 mm thick with provn for cable entry with gald of cable size upto 70 Sqmm complete required for fixing the new one all as specified and directed 5 Each