| 1 | 1 | Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. | | 44 | Cubic Metre |
|---|
| 2 | 2 | Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed. | | 4 | Cubic Metre |
|---|
| 3 | 3 | Removing excavated soils to a distance exceeding 50m but not exceeding 100m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | | 48 | Cubic Metre |
|---|
| 4 | 4 | Cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. | | 4 | Cubic Metre |
|---|
| 5 | 5 | Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. | | 44 | Cubic Metre |
|---|
| 6 | 6 | Cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in coping of poles, complete all as specified and directed. | | 7 | Cubic Metre |
|---|
| 7 | 7 | Dismantling ACSR Conductor any size from HT / LT overhead lines after disconnecting from insulators and depositing to MES Storeyard, complete all as specified and as directed. | | 15 | Quintal |
|---|
| 8 | 8 | Dismantling earth wire any size from eye hooks / insulators and depositing to MES Storeyard, complete all as specified and as directed. | | 4 | Quintal |
|---|
| 9 | 9 | Dismantling insulator of any description from HT / LT Overhead Lines and depositing to MES Storeyard, complete all as specified and as directed. | | 165 | Each |
|---|
| 10 | 10 | Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer and writing Pole No complete including taking down old unserviceable Pole all as specified and as directed. | | 68 | Each |
|---|
| 11 | 11 | Stay assembly complete with accessories as shown in Electrical Plate No.1 of SSR 2009 Part-I using stay rod of 20 mm dia, stay bow 14 mm dia, 400 mm long, MS Plate of size 300 x 300 mm x 6mm thick, stay GI wire 7/4mm dia, including loop type insulator large size with overall dimensions 140mm dia, clearence of hole 25.5mm and stay clamps etc.(excavation and concrete shall be measured and paid separately) complete all as specified and directed. | | 4 | Each\nSet |
|---|
| 12 | 12 | Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed. | | 8 | Quintal |
|---|
| 13 | 13 | Arial Bunched Cable (ABC) 11 KV grade, stranded and compact aluinium phase conductor of size 95 Sqmm 3 Core and 70 Sqmm x 1 Core bare messenger conductor with alumnium alloy. The phase conductor should be insulated with XLPE sioplas compound as per IS:14225-1995 Part-II complete, including taking down old unserviceable cable of any description, all as specified and as directed.\nNote : The contractor shall provide the fittings required viz. anchor clamps, suspension clamps, in-line connectors, service clamps, insulation piercing connectors and tapping from bare line etc. all as directed at site. The Quoted Rate shall be deemed to be inclusive of this provision. | | 4000 | Running Metre |
|---|
| 14 | 14 | Cable jointing kit for 11 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed. | | 2 | Each |
|---|
| 15 | 15 | Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.\n | | 10 | Square Metre |
|---|
| 16 | 16 | Earthing complete with galvanized mild steel earth plate electrode size 600mm x 600mm x 6mm thick buried directly in ground (preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 Part-I, connected to test point complete, all as specified and testing on completion. | | 13 | Each\nSet |
|---|
| 17 | 16.01 | Note :\nOn testing after completion if the desired resistance below 10 Ohms is not obtained the contractor shall get the earthing redone without any extra cost to the department. | | | |
|---|
| 18 | 17 | Earthing continuity conductor or main earthing lead of 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated siuation for loop earthing all as specified and directed. | | 80 | Running Metre |
|---|