Health and Family Welfare Government Departments Closing in 0 days TDR #26924292

Up-Gradation And Rehabilitation Of Sewer Network In Zone I Gangtok , Under National River Conservation Plan - Civil Engineering Works For Major Extension And Rehabilitation Works

Issued by Government Departments · EAST SIKKIM, Sikkim
Tender Value
37.41 Crore
Estimated cost
Bid Submission
25 Feb 2021
0 days left
EMD
93.54 Lakhs
Bank guarantee accepted
Document Fee
2 Lakhs
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
EAST SIKKIM → Sikkim
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Up-Gradation And Rehabilitation Of Sewer Network In Zone I Gangtok , Under National River Conservation Plan - Civil Engineering Works For Major Extension And Rehabilitation Works

BOQ

Name of Work: Up-gradation & Rehabilitation of Sewer Network in Zone I Gangtok, under National River Conservation Plan - Civil Engineering Works for Major Extension & Rehabilitation works.
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Part 1-Cost of Civil Engineering Works for Major Extension & Rehabilitation worksBI01010001010000000000000515BI0100001112
21.01Hill cutting in mixed soil 70% and soft rock 30% including throwing of spoils for 50m lead and 1.5m lift all complete and disposal of debris within 15 KM As per Annexure XIIBI01010001010000000000000515BI01000011130.0001Rm
31.02Laying of Ductile Iron (K7) pipes with sand bedding keeping an invert depth of 1.50 mtrs. Providing & filling of trench with clean course sand, pipe laying and jointing, providing anchor blocks of varying sizes of 1:2:4 Cement Concrete in Plum and carriage of Stock Material within 5 km radius and Non Stock Material within 40 kms to the work site - (vide Annexure II)BI01010001010000000000000515BI0100001114
41.03150 mm dia - Annexure II (A) (i)BI01010001010000000000000515BI01000011155998.14Rm
51.04150 mm dia - Annexure II (A) (ii)BI01010001010000000000000515BI01000011164907.57Rm
61.05200 mm dia - Annexure II (B) (i)BI01010001010000000000000515BI01000011174094.21Rm
71.06200 mm dia - Annexure II (B) (ii)BI01010001010000000000000515BI01000011183349.81Rm
81.07250mm dia - Annexure II (C) (i)BI01010001010000000000000515BI01000011196447.63Rm
91.08250mm dia - Annexure II (C) (ii)BI01010001010000000000000515BI01000011205275.33Rm
101.09300mm dia - Annexure II (D) (i)BI01010001010000000000000515BI01000011211367.3Rm
111.1300mm dia - Annexure II (D) (ii)BI01010001010000000000000515BI01000011221118.7Rm
121.11350mm dia - Annexure II (E) (i)BI01010001010000000000000515BI01000011231498Rm
131.12350mm dia - Annexure II (E) (ii)BI01010001010000000000000515BI01000011240.0001Rm
141.13Laying of SN8 DWC Pipes with sand bedding keeping an invert depth of 1.50 mtrs. Providing & filling of trench with clean course sand, pipe laying and jointing,and carriage of Stock Material within 15 km radius and Non Stock Material within 40 kms to the work site - (vide Annexure XIV)BI01010001010000000000000515BI01000011250.0001Rm
151.14Shoring of trench size 1.00 x 3.00 x 2.00 m with 38 mm thick cement planks of local wood in Uttis etc. of 1.83 and 150 mm wide- (vide Annexure X)BI01010001010000000000000515BI010000112625542.5Rm
161.15Construction of Manhole Chambers of various sizes. Providing hand packed stone soling; 1:3:6/1:2:4mix cement concrete work i/c shuttering centring etx all complete; providing & laying 1:2:4/1:1.5:3 mix of reinforced cement concrete excluding the cost of formwork; supplying bending & binding tor steel reinforcement in all RCC works i/c the cost of binding wires; providing cement plaster as aspecified i/c finishing even and smooth & curing etc all complete Carriage of Stock Materials (within 15 kms) and Non Stock Materials (within 40 kms) - (vide Annexure III)BI01010001010000000000000515BI0100001127
171.16Type \"1E\", Size - 1.0 m x 1.0 m x 1.2 m - Annexure III A (i)BI01010001010000000000000515BI0100001128364Nos
181.17Type \"1E\", Size - 1.0 m x 1.0 m x 1.2 m - Annexure III A (ii)BI01010001010000000000000515BI0100001129212Nos
191.18Type \"1D\", Size - 1.2 m x 1.2 m x 1.5 m - Annexure III A (i)BI01010001010000000000000515BI0100001130336Nos
201.19Type \"1D\", Size - 1.2 m x 1.2 m x 1.5 m - Annexure III A (ii)BI01010001010000000000000515BI0100001131470Nos
211.2Type \"1C\", Size - 1.2 m x 1.2 m x 2 m- Annexure III A (i)BI01010001010000000000000515BI010000113245Nos
221.21Type \"1C\", Size - 1.2 m x 1.2 m x 2 m- Annexure III A (ii)BI01010001010000000000000515BI010000113336Nos
231.22Type \"1B\", Size - 1.2 m x 1.2 m x 2.5 m - Annexure III A (i)BI01010001010000000000000515BI010000113425Nos
241.23Type \"1B\", Size - 1.2 m x 1.2 m x 2.5 m - Annexure III A (ii)BI01010001010000000000000515BI010000113520Nos
251.24Type \"1A\", Size - 1.2 m x 1.2 m x 3 m - Annexure III A (i)BI01010001010000000000000515BI010000113614Nos
261.25Type \"1A\", Size - 1.2 m x 1.2 m x 3 m- Annexure III A (ii)BI01010001010000000000000515BI010000113711Nos
271.26Repair & Renovation of Manhole Chamber to facilitate Rehabilitation Works - (Vide Annexure XV)BI01010001010000000000000515BI0100001138
281.27Type \"1A\", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV A (i)BI01010001010000000000000515BI01000011399Nos
291.28Type \"1A\", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV A (Ii)BI01010001010000000000000515BI010000114017Nos
301.29Type \"1B\", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV B (i)BI01010001010000000000000515BI010000114118Nos
311.3Type \"1B\", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV B (iI)BI01010001010000000000000515BI010000114234Nos
321.31Type \"1C\", Size - 1.2 m x 1.2 m x 2 m - Annexure XV C (i)BI01010001010000000000000515BI010000114349Nos
331.32Type \"1C\", Size - 1.2 m x 1.2 m x 2 m - Annexure XV C (iI)BI01010001010000000000000515BI0100001144174Nos
341.33Type \"1D\", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV D (i)BI01010001010000000000000515BI0100001145500Nos
351.34Type \"1D\", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV D (iI)BI01010001010000000000000515BI0100001146594Nos
361.35Type \"1A\", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV E (i)BI01010001010000000000000515BI01000011472Nos
371.36Type \"1A\", Size - 1.2 m x 1.2 m x 3.0 m - Annexure XV E (Ii)BI01010001010000000000000515BI01000011488Nos
381.37Type \"1B\", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV F (i)BI01010001010000000000000515BI01000011493Nos
391.38Type \"1B\", Size - 1.2 m x 1.2 m x 2.5 m - Annexure XV F (iI)BI01010001010000000000000515BI010000115012Nos
401.39Type \"1C\", Size - 1.2 m x 1.2 m x 2 m - Annexure XV G (i)BI01010001010000000000000515BI010000115130Nos
411.4Type \"1C\", Size - 1.2 m x 1.2 m x 2 m - Annexure XV G (iI)BI01010001010000000000000515BI0100001152120Nos
421.41Type \"1D\", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV H (i)BI01010001010000000000000515BI010000115370Nos
431.42Type \"1D\", Size - 1.2 m x 1.2 m x 1.5 m - Annexure XV H (iI)BI01010001010000000000000515BI0100001154280Nos
441.43Construction of Inspection Chambers of size 600mm x 600mm x 600mm depth. Providing hand packed stone soling; 1:3:6 mic cement concrete work i/c shuttering centring etx all complete; providing & laying 1:2:4 mix of reinforced cement concrete excluding the cost of formwork; supplying bending & binding tor steel reinforcement in all RCC works i/c the cost of binding wires; providing 12.5 mm thick cement plaster of 1:4 mixin single coat i/c finishing even and smooth & curing etc all completeBI01010001010000000000000515BI0100001155
451.44Size - 600mm x 600mm x 600m - Annexure IV A (i)BI01010001010000000000000515BI010000115659Nos
461.45Size - 600mm x 600mm x 600m - Annexure IV A (iI)BI01010001010000000000000515BI010000115728Nos
471.46Size - 600mm x 600mm x 900m - Annexure IV B (i)BI01010001010000000000000515BI010000115855Nos
481.47Size - 600mm x 600mm x 900m - Annexure IV B (Ii)BI01010001010000000000000515BI010000115945Nos
491.48Construction of Reinforced Cement Concrete Beam Bridge of size 0.45 m x 0.45 m x 6.00 m (height) (2 Nos) of beam length 16 mtrs. Providing & laying hand packed stone soling (6\"), 1:3:6 Cement Concrete (4\"), Providing and laying 1:2:4 RCC excluding cost of formwork, finishing & reinforcement, Supplying bending and binding in position Tor Steel Reinforcement in all RCC Works i/c cost of binding wires etc all complete.BI01010001010000000000000515BI0100001160
501.49Annexure VI (i)BI01010001010000000000000515BI01000011610.0001Nos
511.5Annexure VI (iI)BI01010001010000000000000515BI01000011624Nos
521.51Provision for drains - (vide Annexure XII)BI01010001010000000000000515BI0100001163
531.52Providing Box Drain of 60 cm (ht) x 45 cm (width) of internal dimension as per sepcifications for this item in SOR 12, PWD, Govt. of SikkimBI01010001010000000000000515BI0100001164470Rm
541.53Providing Box Drain of 40 cm (ht) x 30 cm (width) of internal dimension as per sepcifications for this item in SOR 12, PWD, Govt. of SikkimBI01010001010000000000000515BI010000116575Rm
551.54Providing \"U\" as per sepcifications for this item in SOR 12, PWD, Govt. of SikkimBI01010001010000000000000515BI01000011660.0001Rm
561.55Construction of RCC Pillar Support of size as specified below of height 2.40 m. Providing and layin RCC of 1:2:4 excluding the cost of formwork finishing & reinforcement, Supplying bending and binding in position Tor Steel Reinforcement in all RCC works i/c the cost of binding wires etc all complete Carriage of Stock Materials (within 5 kms) and Non Stock Materials (within 30 kms) with an Average Head Load of 100 mtrs (vide Annexure V).BI01010001010000000000000515BI0100001167
571.56size 300 mm x 300 mm - Annexure V A (i)BI01010001010000000000000515BI01000011680.0001Nos
581.57size 300 mm x 300 mm - Annexure V A (ii)BI01010001010000000000000515BI010000116941Nos
591.58size 450 mm x 500 mm - Annexure V B (i)BI01010001010000000000000515BI01000011700.0001Nos
601.59size 450 mm x 500 mm - Annexure V B (ii)BI01010001010000000000000515BI010000117115Nos
611.6Construction of damaged Cement Concrete footpath with hand packed stone soling (6\") and Cement Concrete (4\") works of 1:3:6 mix for a width of 1.00 mtr. Carriage of Stock Materials (within 5 kms) and Non Stock Materials (within 30 kms) Average head load of 100 mtrs (vide Annexure VII).BI01010001010000000000000515BI0100001172
621.611.066m wide - Annexure VII A (i)BI01010001010000000000000515BI01000011732318.11Rm
631.621.066m wide - Annexure VII A (ii)BI01010001010000000000000515BI01000011741896.64Rm
641.631.52m wide - Annexure VII B (i)BI01010001010000000000000515BI01000011751517.41Rm
651.641.52m wide - Annexure VII B (ii)BI01010001010000000000000515BI01000011761241.51Rm
661.651.066 wide with cladding - Annexure VII C (i)BI01010001010000000000000515BI0100001177201.3Rm
671.661.066 wide with cladding - Annexure VII C (ii)BI01010001010000000000000515BI0100001178164.7Rm
681.671.52m wide with cladding - Annexure VII D (i)BI01010001010000000000000515BI010000117986.63Rm
691.681.52m wide with cladding - Annexure VII D (ii)BI01010001010000000000000515BI010000118070.88Rm
701.69Road Restoration worksBI01010001010000000000000515BI0100001181
711.7Road Restoration with 20 mm premix carpetting and seal coat - vide Annexure IX (a)BI01010001010000000000000515BI01000011829595.52Rm
721.71Road restoration works with 60mm Dense Graded Bitumonous Macadam and 40mm Bitumionous Concrete Wearing Course - vide Annexure IX (b)BI01010001010000000000000515BI01000011836214Rm
731.72Construction of Retaining wall in Plum Cement Concrete of 1:2:4 Cement Concrete mix with 50 % clean hard stone sizes not exceeding 15 cm i/c shuttering, compacting & curing etc all complete. Carriage of Stock Materials (within 15 kms) and Non Stock Materials (within 40 kms) & Head Load as specified - as per sepcified heights - (vide Annexure VIII)BI01010001010000000000000515BI0100001184
741.731.5m height - Annexure VIII A (i)BI01010001010000000000000515BI0100001185168Rm
751.741.5m height - Annexure VIII A (ii)BI01010001010000000000000515BI0100001186672Rm
761.752.0m height - Annexure VIII B (i)BI01010001010000000000000515BI0100001187242Rm
771.762.0m height - Annexure VIII B (ii)BI01010001010000000000000515BI0100001188968Rm
781.773.0m height - Annexure VIII C (i)BI01010001010000000000000515BI0100001189243Rm
791.783.0m height - Annexure VIII C (ii)BI01010001010000000000000515BI0100001190972Rm
802PART 2 - Rennovation of 4.69 MLD STP, Adampool Gangtok Zone IBI01010001010000000000000515BI0100001191
812.01Repairing of Flow transmitter including laying of cable if needed with necessary termination of cable with changing of terminals push buttons to working condition and commissioningBI01010001010000000000000515BI01000011921nos
822.02Repairing of incoming gates. ( Removing, dismantling, servicing required, oiling and greasing excluding materials) .BI01010001010000000000000515BI01000011934nos
832.03Repairing of grit classifier. (Removing, making of shaft with pionium and coupling , oiling greasing and fixing the same excluding materials.BI01010001010000000000000515BI01000011941nos
842.04Repairing or replacing of gear box of Grit Classifier including shaft oiling and greasing, totally fixing with required gear ratio for proper functioning and commissioning. Gear box totally broken)BI01010001010000000000000515BI01000011951nos
852.05Repairing of Grit separator With gear box, checking of Scraper with rubber squeezer replacing, fixing of Gear box with motor with total servicingBI01010001010000000000000515BI01000011961nos
862.06Servicing of belt conveyor with gear box, motor , oiling and greasing and bring the unit to operation with required operation (including material)BI01010001010000000000000515BI01000011971nos
872.07Repairing of Mechanical Jash Screen and Jash Screen Electrical panel with change in bearing terminal points switches display lights , resisting springs, rollersand fixing of bars as per requirement and brining the unit in operation. (including material)BI01010001010000000000000515BI01000011981nos
882.08Flushing of MBBR tank 1 and 2 with clearing of airline choke for maintaining proper Dissolved Oxygen in both the tank and bringing the tank to proper operation.BI01010001010000000000000515BI01000011992nos
892.09Repairing of Claritube Settler bridge with Gear box repairing , fixing of rail, chain drive, roller bearing Changing of spares of CTS panel with motor fixing , oiling, greasing and bringing the Claritube settler system to operation.BI01010001010000000000000515BI01000012001nos
902.1Ordering and fixing of missing tubemedia from manufacturer and arranging as per needed for proper functioning of tube mediaBI01010001010000000000000515BI01000012011MTR.
912.11Supply and fixing of 2 nos Submersible pumps in Sludge sump with required specifications and fixing of piping line as per requirement.BI01010001010000000000000515BI01000012022nos
922.12Repairing of 2 nos Centrifuge with required bearing oiling and greasing, with Centrifuge panel repairing and fixing with proper operation.BI01010001010000000000000515BI01000012032nos
932.13Servicing of 3 nos Air blowers with filters, bearing lobe servicing blower alignment or any thing required for proper functioning of blowers with installation of new pressure gauges.BI01010001010000000000000515BI01000012043nos
942.14Total plant lighting change with junction box and internal termal , capacitors resistors, etc with cable replacing if damaged and replace light fitting to LED lights including materialsBI01010001010000000000000515BI01000012051lot
952.15Painting of all civil structures and mechanical units including Structural steel cable tray supports pipe supports, piping for total painting of 4.69 MLD STP.(including materials)BI01010001010000000000000515BI01000012061lot
962.16Reparing of MCC Panel with required Fuses, indication lights, push buttons, RRCB, MCB etc for proper functioning of the plant.BI01010001010000000000000515BI01000012071lot
972.17Supply of Office table, Chairs, almirah, refilling of Fire extinguishers.BI01010001010000000000000515BI01000012081lot
982.18Clearing of drying bedBI01010001010000000000000515BI01000012091lot
992.19Clearing of all retaining tanksBI01010001010000000000000515BI01000012101Lump Sum
1002.2Provision for lab equipments & chemicalsBI01010001010000000000000515BI01000012111Lump Sum
1012.21Provision for DiversionBI01010001010000000000000515BI01000012121Lump Sum
1023PART 3 - Renovation of 3.9 MLD Plant, Sichey, GANGTOKBI01010001010000000000000515BI0100001213
1033.01Repairing of Flow transmitter including laying of cable if needed with necessary termination of cable with changing of terminals push buttons to working condition and commissioningBI01010001010000000000000515BI01000012141nos
1043.02Repairing of incoming gates. ( Removing, dismantling, servicing required, oiling and greasing excluding materials) .BI01010001010000000000000515BI01000012154nos
1053.03Repairing of grit classifier. Total arrangement to be taken out , fabrication of arm, shaft , flywheel, total alignment and erection.(Removing, making of shaft with pinion and coupling , oiling greasing and fixing the same excluding materials.BI01010001010000000000000515BI01000012161nos
1063.04Repairing or replacing of gear box of Grit Classifier including shaft oiling and greasing, totally fixing with required gear ratio for proper functioning and commissioning. Gear box totally broken)BI01010001010000000000000515BI01000012171nos
1073.05Repairing of Grit separator With gear box, checking of Scraper with rubber squeezer replacing, fixing of Gear box with motor with total servicingBI01010001010000000000000515BI01000012181nos
1083.06Servicing of belt conveyor with gear box, motor , oiling and greasing and bring the unit to operation with required operation (including material)BI01010001010000000000000515BI01000012191nos
1093.07Repairing of Mechanical Jash Screen and Jash Screen Electrical panel with change in bearing terminal points switches display lights , resisting springs, roller sand fixing of bars as per requirement and brining the unit in operation. (including material)BI01010001010000000000000515BI01000012201nos
1103.08Flushing of MBBR tank 1 and 2 with clearing of airline choke for maintaining proper Dissolved Oxygen in both the tank and bringing the tank to proper operation.BI01010001010000000000000515BI01000012212nos
1113.09Repairing of Claritube Settler bridge with Gear box repainting , fixing of rail, chain drive, roller bearing Changing of spares of CTS panel with motor fixing , oiling, greasing and bringing the Claritube settler system to operation.BI01010001010000000000000515BI01000012221nos
1123.1Clearing of tank with fixing rubber squeezer, checking of scraper alignment, and epoxy painting of structural trusses.BI01010001010000000000000515BI01000012231lot
1133.11Servicing and fixing of 2 nos Screw pumps, checking of rotor and stator in Sludge sump with required specifications and fixing of piping line as per requirement.BI01010001010000000000000515BI01000012242nos
1143.12Repairing of 1 nos Centrifuge with required bearing oiling and greasing, with Centrifuge panel , if VFD is ok or not repairing and fixing with proper operation.BI01010001010000000000000515BI01000012251nos
1153.13Servicing of 3 nos Air blowers with filters, bearing lobe servicing blower alignment or anything required for proper functioning of blowers with installation of new pressure gauges.BI01010001010000000000000515BI01000012263nos
1163.14Total plant lighting change with junction box and internal termal , capacitors resistors, etc with cable replacing if damaged and replace light fitting to LED lights including materialsBI01010001010000000000000515BI01000012271lot
1173.15Painting of all civil structures and mechanical units including Structural steel cable tray supports pipe supports, piping for total painting of 4.69 MLD STP.(including materials)BI01010001010000000000000515BI01000012281lot
1183.16Repairing of MCC Panel with required Fuses, indication lights, push buttons, RRCB, MCB etc for proper functioning of the plant.BI01010001010000000000000515BI01000012291lot
1193.17Checking of chlorination system and Polydosing system, oiling of pumps, servicing and arranging piping as per required. Changing of HDPE pipe arrangement to UPVC pipe for better functioning with proper structural support and clamps.BI01010001010000000000000515BI01000012301lot
1203.18Clearing of drying bedBI01010001010000000000000515BI01000012311lot
1213.19Clearing of all retaining tanksBI01010001010000000000000515BI01000012321Lump Sum
1223.2Provision for lab equipments & chemicalsBI01010001010000000000000515BI01000012331Lump Sum
1233.21Provision for DiversionBI01010001010000000000000515BI01000012341Lump Sum
1244PART 4 - Renovation of 8 MLD Plant, Adampool, Gangtok Zone IBI01010001010000000000000515BI0100001235
1254.01Repairing of incoming gates. (Removing, dismantling, servicing required, oiling and greasing excluding materials) .BI01010001010000000000000515BI01000012364nos
1264.02Repairing of grit classifier, servicing, oiling changing of bearings, rollers .(Removing, making of shaft with pinion and coupling , oiling greasing and fixing the same.BI01010001010000000000000515BI01000012371nos
1274.03Repairing of Grit Separator With gear box, checking of Scraper with rubber squeezer replacing, fixing of Gear box with motor with total servicingBI01010001010000000000000515BI01000012381nos
1284.04Flushing of MBBR tank 1 and 2 with clearing of airline choke for maintaining proper Dissolved Oxygen in both the tank and bringing the tank to proper operation.BI01010001010000000000000515BI01000012392nos
1294.05Repairing of Claritube Settler bridge with Gear box repainting , fixing of rail, chain drive, roller bearing Changing of spares of CTS panel with motor fixing , oiling, greasing and bringing the Claritube settler system to proper operation.BI01010001010000000000000515BI01000012401nos
1304.06Clearing of tank with fixing rubber squeezer, checking of scraper alignment, etc for proper functioning of CTS.BI01010001010000000000000515BI01000012411lot
1314.07Supply and fixing of 2 nos Submersible pumps in Sludge sump with required specifications and fixing of piping line as per requirement.BI01010001010000000000000515BI01000012422nos
1324.08Servicing of 3 nos Air blowers with filters, bearing lobe servicing blower alignment or anything required for proper functioning of blowers with installation of new pressure gauges.BI01010001010000000000000515BI01000012433nos
1334.09Repairing of 1 nos Centrifuge with required bearing oiling and greasing, with Centrifuge panel , if VFD is ok or not repairing and fixing with proper operation.BI01010001010000000000000515BI01000012441nos
1344.1Total plant lighting change with junction box and internal thermal , capacitors resistors, etc with cable replacing if damaged and replace light fitting to LED lights including materialsBI01010001010000000000000515BI01000012451lot
1354.11Painting of all civil structures and mechanical units including Structural steel cable tray supports pipe supports, piping for total painting of 8 MLD STP.(including materials)BI01010001010000000000000515BI01000012461lot
1364.12Repairing of MCC Panel with required Fuses, indication lights, push buttons, RRCB, MCB etc for proper functioning of the plant.BI01010001010000000000000515BI01000012471lot
1374.13Clearing of drying bedBI01010001010000000000000515BI01000012481lot
1384.14Clearing of all retaining tanksBI01010001010000000000000515BI01000012491Lump Sum
1394.15Provision for lab equipments & chemicalsBI01010001010000000000000515BI01000012501Lump Sum
1404.16Provision for DiversionBI01010001010000000000000515BI01000012511Lump Sum
1415PART 5 - Construction of Holding Tank (Activating Trickling Filter System), and Other Reconditioning and Augmentation Works in STP Complex in AdampoolBI01010001010000000000000515BI0100001252
1425.01Clearing of HRTF and ST of debris.BI01010001010000000000000515BI01000012532400mandays
1435.02Chipping/Dismantelling of old RCC flooring and the plasters of wall etc and throwing of debris in designated place by mannual means.BI01010001010000000000000515BI010000125410800mandays
1445.03P/Laying 1:1.5:3 RCC in position specified grade of reinforced cement concrete excluding the cost of formwork,finishing and reinforcement.BI01010001010000000000000515BI0100001255516.57cum
1455.04S/B/B in reinforcement in RCC wprks including cost of binding wire al completeBI01010001010000000000000515BI0100001256774.86qtls
1465.05P/L 20 mm thick cc plaster in 1 : 3 mix i/c finishing even and smooth anad curing etc all complete.BI01010001010000000000000515BI01000012572357.68sqm
1475.06Carriage of Stock MaterialsBI01010001010000000000000515BI0100001258
1485.07Loading and Unloading of stock Materials by Manual means or stacking.BI01010001010000000000000515BI01000012591011.51MT
1495.08Cost of Haulage (10km)BI01010001010000000000000515BI01000012601011.51MT
1505.09Carriage of non stock materials to work site within 40KM for particularBI01010001010000000000000515BI0100001261
1515.1Loading and Unloading of Non-stock Materials by Manual means or stacking (sand)BI01010001010000000000000515BI0100001262495.67cum
1525.11Loading and Unloading of Non-stock Materials by Manual means or stacking (stone)BI01010001010000000000000515BI0100001263439.09cum
1535.12Cost of HaulageBI01010001010000000000000515BI01000012641892.9MT
1545.13Provision for making floor scrubber for sedimentation tank inclusive of motor mechanismBI01010001010000000000000515BI01000012652Lump Sum
1555.14Provision for making inlet with screen and outlets for each tank including intallation of control valves \t\t\t\t\t\tBI01010001010000000000000515BI01000012661Lump Sum
1565.15Provision for repair of electrifiation line etc. at STP Zone 1, inclusive of provision for supply and installation of backup inverterBI01010001010000000000000515BI01000012671Lump Sum
1575.16Provision for reconditioning of pipesBI01010001010000000000000515BI01000012681Lump Sum
1585.17Repair of pump HouseBI01010001010000000000000515BI01000012691Lump Sum
1595.18Laying of 150 mm D.I pipeBI01010001010000000000000515BI0100001270165mtr
1605.19Construction of manhole chambers 1.2mx1.2mx2mBI01010001010000000000000515BI010000127111nos
1615.2Construction of foothpath - 1.52m wide with cladding - Annexure VII D (i)BI01010001010000000000000515BI0100001272350mtrs
1625.21Provision for fencing to separate plant area from family residential complexBI01010001010000000000000515BI0100001273450mtrs
1635.22Supply of pipes and fittings inclusive of GST & STCS comm (150mm dia)BI01010001010000000000000515BI0100001274165mtrs
1645.23Supply of Machines and toolsBI01010001010000000000000515BI0100001275
1655.241 HP PUMPBI01010001010000000000000515BI01000012762nos
1665.253 HP PUMPBI01010001010000000000000515BI01000012774nos
1675.265 HP PUMPBI01010001010000000000000515BI01000012783nos
1685.277 HP PUMPBI01010001010000000000000515BI01000012793nos
1695.28Grinding machineBI01010001010000000000000515BI01000012801nos
1705.29MultimeterBI01010001010000000000000515BI01000012811nos
1715.3Ultrasonic Flow meterBI01010001010000000000000515BI01000012823nos
1725.31Submersible pumpBI01010001010000000000000515BI01000012833nos
1735.32Gear boxBI01010001010000000000000515BI01000012842nos
1745.33Blower beltBI01010001010000000000000515BI010000128512nos
1755.34wheel barrowBI01010001010000000000000515BI01000012865nos
1765.3518% GST on item no 92BI01010001010000000000000515BI01000012871Lump Sum
1775.36Setting up of new centrifuge systemBI01010001010000000000000515BI0100001288
1785.3780 mm D.I pipe (inclusive of STCS comm & GST)BI01010001010000000000000515BI0100001289150mtr
1795.38Pipe jointingBI01010001010000000000000515BI0100001290150mtr
1805.39Supply of pumps - sumersible ABS-MF 804 DKS or equivalent or others as specifiedBI01010001010000000000000515BI01000012912nos
1815.418% GST on item no 92.03BI01010001010000000000000515BI01000012921Lump Sum
1825.41Intallation of pump including electrificationBI01010001010000000000000515BI01000012931Lump Sum
1835.42Provision for Stand-by Blower & MotorBI01010001010000000000000515BI0100001294
1845.43Everest Air cooled Blower 710 9complete with all standard accessories)BI01010001010000000000000515BI01000012952nos
1855.44Everest 40 HP standard electric motorBI01010001010000000000000515BI01000012962nos
1865.45Carraige and packagingBI01010001010000000000000515BI01000012971Lump Sum
1875.4618% GST on item no 94.01 & 94.02BI01010001010000000000000515BI01000012981Lump Sum
1885.47Provision for construction chemcials, saftey equipments & clothingBI01010001010000000000000515BI01000012991Lump Sum
1895.48Labour Welfare Cess, @ 1%BI01010001010000000000000515BI01000013001Lump Sum

AI Tender Summary

OUR REF NO 26924292
AUTHORITY Government Departments
TENDER VALUE 37.41 Crore
LAST DATE 25-02-2021
Authority
Authority Name Water Security and Public Health Engineering
Work Description Up-Gradation And Rehabilitation Of Sewer Network In Zone I Gangtok , Under National River Conservation Plan - Civil Engineering Works For Major Extension And Rehabilitation Works
Basic Detail
Tender No 02/ETENDER/PHED/2021
Bidding Type Tender
Location
City EAST SIKKIM
State Sikkim
Key Dates
Publish Date 10 Feb 2021
Submission Date 25 Feb 2021
Open Date 01 Mar 2021
Finance
Tender Value 37.41 Crore
Tender Fee 2 Lakhs
EMD 93.54 Lakhs
Exemption Not Available
Document List
BOQ_564.xls
1988680E-1D65-435F-9CEB-652EB9082B29.html
Tendernotice_1.pdf
Tender_Document.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 10, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 25, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 01, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_564.xls

html

1988680E-1D65-435F-9CEB-652EB9082B29.html

pdf

Tendernotice_1.pdf

pdf

Tender_Document.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders