Road Transport and Highways Government Departments Closing in 0 days TDR #26923885

Rehabilitation And Up Gradation Of Vadayar Chandappalam Mulakkulam Road And Vadayar Kallattippalam Muttuchira Road Length Of 22 . 476 Km In Kottayam District

Issued by Government Departments · Kottayam, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 Mar 2021
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Rehabilitation And Up Gradation Of Vadayar Chandappalam Mulakkulam Road And Vadayar Kallattippalam Muttuchira Road Length Of 22 . 476 Km In Kottayam District

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Mar-2021 Addendum Date 29-Mar-2021

BOQ

Name of Work: Rehabilitation and Up gradation of Vadayar Chandappalam- Mulakkulam Road and Vadayar Kallattippalam Muttuchira Road (Length 22.476 km) in Kottayam District
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11BILL-1 SITE CLEARANCEBI01010001010000000000000515BI0100001112
21.1Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned including removal and disposal of top organic soil not exceeding 150 mm thickness with all lead & Lift , all complete as per Technical Specification Clause 201.BI01010001010000000000000515BI010000111310Ha
31.2Removal of stumps and roots of girth above 300mm and back filling to required compactionwith all lead & lift ,all complete as per Technical Specification Clause 201 and 305.BI01010001010000000000000515BI0100001114
41.21Girth from 300 mm to 600 mmBI01010001010000000000000515BI010000111574Nos.
51.22Girth from 600 mm to 900 mmBI01010001010000000000000515BI010000111675Nos.
61.23Girth from 900 mm to 1800 mmBI01010001010000000000000515BI010000111730Nos.
71.24Girth above 1800 mmBI01010001010000000000000515BI010000111838Nos.
81.3Dismantling of flexible pavements and disposal of dismantled materials, stacking serviceable and unserviceable materials separately with all lead & lift ,all complete as per Technical Specification Clause 202.BI01010001010000000000000515BI0100001119
91.31BituminousBI01010001010000000000000515BI01000011206870cum
101.32GranularBI01010001010000000000000515BI01000011213370cum
111.33Earth removalBI01010001010000000000000515BI0100001122250cum
122BILL-2 EARTHWORKSBI01010001010000000000000515BI0100001123
132.1Excavation for roadwork in all type of soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead all complete as per Technical Specification Clause 301.BI01010001010000000000000515BI010000112422000cum
142.2Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2 all complete as per Technical Specification Clause 305.BI01010001010000000000000515BI01000011258000cum
152.3Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 all complete as per Technical Specification Clause 305.BI01010001010000000000000515BI01000011261000cum
162.4Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 all complete as per Technical Specification Clause 305.BI01010001010000000000000515BI010000112732910cum
172.5Construction of sub-grade and earthen shoulders with approved material deposited at site from roadway cutting and excavation from drain all complete as per Technical Specification Clause 305.BI01010001010000000000000515BI010000112823000cum
183BILL -3 SUBBASE AND BASE COURSESBI01010001010000000000000515BI0100001129
193.1Construction of granular sub-base by providing close graded material conforming to grading-V of table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 of Technical Specifcations.BI01010001010000000000000515BI010000113018630cum
203.2Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per Drawings and Technical Specification Clause 406.BI01010001010000000000000515BI01000011316030cum
214BILL-4 PAVEMENT COURSESBI01010001010000000000000515BI0100001132
224.01Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means all complete as per Clause 502.2BI01010001010000000000000515BI010000113339980sqm
234.02Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.30 kg/sqm on the prepared bituminous/granular surface cleaned with mechanical broom all complete as per Clause 503.BI01010001010000000000000515BI010000113467570sqm
244.03Providing and laying dense graded bituminous macadam Grade II with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects. Note : The Binder content specified shall be minimum 4.5 % but will conform to requirement as per JMF. No additional cost shall be paid to the actual Binder Content as required in JMF.BI01010001010000000000000515BI01000011351380cum
254.04Providing and laying bituminous concrete Grade 2 with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.4 per cent of mix and filler, plastic waste @ 8% of Bitumen by weight, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects..Note The Binder content specified shall be minimum 5.4% but will conform to requirement as per JMF. No additional cost shall be paid to the actual Binder Content as required in JMFBI01010001010000000000000515BI01000011361200cum
264.05Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing complete as per drawing and Technical Specification Clause 601.BI01010001010000000000000515BI010000113711500cum
274.06Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades complete as per drawing and Technical Specification Clause 602.BI01010001010000000000000515BI010000113822100cum
285BILL-5 CULVERTBI01010001010000000000000515BI0100001139
295.01Earth work in excavation of foundation of structures including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material in all types of soil with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI01000011408000cum
305.02Providing & Laying Plain cement concrete of M15 Grade in leveling course below foundation complete as per drawing and Technical Specification Sections 1500 and 1700.BI01010001010000000000000515BI0100001141500cum
315.03Providing & Laying Plain/Reinforced Cement Concrete M 20 for Head Walls and wing wall in foundation including formwork but excluding reinforcement complete as per drawing, Technical Specification Sections 1500, 1700 and 2100BI01010001010000000000000515BI0100001142350cum
325.04Providing & Laying Plain/Reinforced Cement Concrete M 20 for Head Walls and wing wall in substructure including formwork but excluding reinforcement complete as per drawing, Technical Specification Sections 1500, 1700 and 2200.BI01010001010000000000000515BI0100001143450cum
335.05Providing & Laying Reinforced Cement Concrete of M25 Grade in Substructure including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1500, 1700 and 2200.BI01010001010000000000000515BI010000114420cum
345.06Providing & Laying Reinforced Cement Concrete of M30 Grade in Open Foundation including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1500, 1700 and 2100.BI01010001010000000000000515BI0100001145600cum
355.07Providing & Laying Reinforced Cement Concrete of M30 Grade in Substructure including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1500, 1700 and 2200.BI01010001010000000000000515BI0100001146500cum
365.08Providing & Laying Reinforced Cement Concrete of M30 Grade in Superstructure including formwork but excluding reinforcement complete as per Drawing and Technical Specification Sections 1500, 1700 and 2300.BI01010001010000000000000515BI0100001147160cum
375.09Providing & Laying Plain/Reinforced Cement Concrete of M30 Grade in Parapet complete as per drawing & MORT&H Specifications sections 1500, 1600, 1700, 2200, 811 and 809.BI01010001010000000000000515BI0100001148140cum
385.1Providing, fitting and placing in position coated HYSD bar of grade Fe 500D reinforcement in foundation complete as per drawing and Technical Specification Section 1600.BI01010001010000000000000515BI010000114950MT
395.11Providing, fitting and placing in position coated HYSD bar of grade Fe 500D reinforcement in sub-structure complete as per drawing and Technical Specification Sections 1600 and 2200BI01010001010000000000000515BI010000115050MT
405.12Providing, fitting and placing in position coated HYSD bar of grade Fe 500D reinforcement in super-structure complete as per drawing and Technical Specification Sections 1600 and 2300BI01010001010000000000000515BI010000115120MT
415.13Providing and painting with Synthetic enamel paints of approved quality on bridges with bridge no. and span arrangemetns as per IRC - 7, 1971 .BI01010001010000000000000515BI010000115290Nos.
425.14Providing and fixing Tar paper bearing complete as per drawing and Technical Specifications Clause 2011.BI01010001010000000000000515BI010000115320sqm
435.15Providing and applying 2 coats of Enamel paint to RCC Crash barrier complete as per Technicla Specification Section 800BI01010001010000000000000515BI0100001154410sqm
445.16Providing and laying in position 65 mm thick wearing coat consisting of 40 mm thick bituminous concrete overlaid with a 25 mm thick layer of mastic asphalt all complete as per drawings and Technical Specifications Clause 2702.BI01010001010000000000000515BI01000011551440sqm
455.17Back filling behind abutments, wing walls and return walls with selected granular material of approved quality complete as per Drawing and Technical Specifications Clause 305.BI01010001010000000000000515BI0100001156870cum
465.18Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification 2504BI01010001010000000000000515BI0100001157890cum
475.19Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/ return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards draining face. including all cost and conveyance of materials labour charges etc complete as per Technical Specification Clause 2706.BI01010001010000000000000515BI0100001158580Lm
485.2Providing Plain Cement Concrete M 15 for Encasing and Curtain wall etc. including formwork but excluding reinforcement complete as per drawing, Technical Specification Sections 1500, 1700 and 2100.BI01010001010000000000000515BI0100001159740cum
495.21Providing Plain Cement Concrete M20 for Encasing complete as per drawing, Technical Specification Sections 1500, 1700, 2100 and 2507BI01010001010000000000000515BI0100001160110cum
505.22Flexible Apron:Providing and laying of boulder apron on river bed for protection against scour with stone boulders as per Technical Specification Clause 2503.2BI01010001010000000000000515BI01000011611550cum
515.23Construction of Rigid apron using M15 Concrrete bedding all complete as per drawing and Technical Specification Clause 2505.1BI01010001010000000000000515BI0100001162350cum
525.24Providing and fixing in position drainage spouts using 100mm dia GI pipe ,complete as per drawings and Technical Specifications Clause 2705.BI01010001010000000000000515BI010000116350Nos.
535.25Dismantling of PCC head wall including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead all complete as per Technical Specification 202.BI01010001010000000000000515BI010000116420cum
545.26Dismantling of masonary wall including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead all complete as per Technical Specification 202.BI01010001010000000000000515BI0100001165290cum
555.27Dismantling of Reinforced Cement Concrete including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead complete as per Technical Specification Clause 202.BI01010001010000000000000515BI0100001166140cum
565.28Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40kg each complete as per drawing and Technical Specification Clause 2504.2.1BI01010001010000000000000515BI0100001167470cum
575.29Providing and laying filtermedia below stone pitching on slopes complete as per drawing and Technical Specification Clause 2504.2.2BI01010001010000000000000515BI0100001168200cum
585.3Laying Reinforced cement concrete pipe NP4/prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar1:2 but excluding bedding, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets complete as per drawings and Technical Specification Section 2906BI01010001010000000000000515BI0100001169
595.3011200 mm diaBI01010001010000000000000515BI0100001170180Lm
605.302Providing and laying granular bedding below pipe complete as per drawings and Technical Specification Section 2900BI01010001010000000000000515BI010000117170cum
615.31Removing all type of hume pipes and stacking within a lead of 1000 metres including earthwork and dismantling of masonry works.BI01010001010000000000000515BI0100001172
625.311Up to 600 mm diaBI01010001010000000000000515BI010000117370Lm
635.312Above 600 mm to 900 mm diaBI01010001010000000000000515BI010000117410Lm
645.32Dismantling of existing bituminous surface and disposal of dismantled materials, stacking serviceable and unserviceable materials separately with all lead & lift ,all complete as per Technical Specification Clause 202.BI01010001010000000000000515BI0100001175310cum
656BILL-6 MINOR BRIDGEBI01010001010000000000000515BI0100001176
666.01Earth work in excavation of foundation of structures including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material in all types of soil with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI01000011771900cum
676.02Back filling behind abutment, wing wall/retaining wall and return walls or other area complete as per drawing and Technical Specification Clauses Clause 305 and Section 2500.BI01010001010000000000000515BI0100001178300cum
686.03Providing and laying of Filter media behind walls of Abutment, retaining wall etc. with granular materials/stone crushed aggregates complete as per drawing and Technical Specification Clause 2504.2.2.BI01010001010000000000000515BI0100001179150cum
696.04Plain Cement Concrete Grade M 15 levelling course in foundation and annular filling complete as per drawings and Technical Specifications Sections 1500, 1700 and 2100.BI01010001010000000000000515BI0100001180200cum
706.05Reinforced cement concrete in open foundation for piers, abutments, wing walls, retaining walls grade RCC M35 complete as per drawing and Technical Specifications Section 1500, 1700 and 2100BI01010001010000000000000515BI0100001181400cum
716.06Reinforced cement concrete in substructure for piers, abutments, wing walls, retaining walls complete as per drawing and Technical Specifications Section 1500, 1700 and 2200BI01010001010000000000000515BI0100001182
726.07RCC M35BI01010001010000000000000515BI0100001183200cum
736.08Structural cement concrete for reinforced concrete in superstructure complete for RCC (cast in situ) deck slab, girders, voided slab, etc. excluding reinforcement but including shuttering and staging complete as per drawing and Technical Specification Sections 1500, 1700 and 2300.BI01010001010000000000000515BI0100001184
746.081RCC M35BI01010001010000000000000515BI0100001185250cum
756.09Providing, fitting and placing in position coated HYSD bar of grade Fe 500D reinforcement in foundation complete as per drawing and Technical Specification Section 1600, 2200 and 2300.BI01010001010000000000000515BI0100001186
766.091FoundationBI01010001010000000000000515BI010000118730MT
776.092Sub-StructureBI01010001010000000000000515BI010000118820MT
786.093Super-StructureBI01010001010000000000000515BI010000118920MT
796.1Providing and laying in position 65 mm thick wearing coat consisting of 40 mm thick bituminous concrete overlaid with a 25 mm thick layer of mastic asphalt all complete as per drawings and Technical Specifications Clause 2702.BI01010001010000000000000515BI0100001190400sqm
806.11Providing and fixing of drainage spouts along with drain pipes complete as per drawing and Technical Specifications Clause 2705.BI01010001010000000000000515BI010000119150Nos.
816.12Plain Cement Concrete Grade M 15 as levelling course below approach slab complete as per drawings and Technical Specifications Section 1500 and 1700.BI01010001010000000000000515BI010000119215cum
826.13Reinforced cement concrete M-30 in approach slab including reinforcement complete as per drawing and Technical Specification Sections 1500, 1600, 1700 and 2700.BI01010001010000000000000515BI010000119330cum
836.14Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-40 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all complete as per drawing & Technical Specifications Clauses 809 & 811 and Sections 1500, 1600, 1700 and 2200.BI01010001010000000000000515BI010000119480Lm
846.15Providing and painting with Synthetic enamel paints of approved quality on bridges with bridge no. and span arrangemetns as per IRC - 7, 1971 and as directed by engineerBI01010001010000000000000515BI01000011952Nos.
856.16Providing weep holes in Plain/Reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications Section 2700BI01010001010000000000000515BI0100001196150Nos.
866.17Providing and laying pitching on slopes laid over prepared filter material including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical Specification Clause 2504.BI01010001010000000000000515BI010000119770cum
876.18Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.BI01010001010000000000000515BI010000119830cum
886.19Providing and applying 2 coats of Enamel paint to RCC Crash barrier complete as per Technicla Specification Section 800BI01010001010000000000000515BI010000119975sqm
896.2Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40kg each complete as per drawing and Technical Specification Clause 2504.2.1BI01010001010000000000000515BI0100001200300cum
906.21Construction of Rigid apron 150mm thick flat stone embedded in 300mm thick M-15 grade concrete as per drawing and Technical Specification Clause 2505BI01010001010000000000000515BI0100001201150cum
916.22Structural Plain Cement Concrete M 15 for Toe wall curtain wall etc. including formwork, excluding reinforcement complete as per drawing, Technical Specification Sections 1500, 1700, 2100 & 2507BI01010001010000000000000515BI0100001202150cum
926.23Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6% bitumen by weightBI01010001010000000000000515BI010000120325Lm
936.24Removal of existing asphaltic wearing coat including disposal with all lift and lead complete as per Technical Specification Clause 202.BI01010001010000000000000515BI010000120455cum
946.25Dismantling of Reinforced Cement Concrete including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead complete as per Technical Specification Clause 202.BI01010001010000000000000515BI010000120550cum
957BILL-7 REPAIR AND REHABILATIONBI01010001010000000000000515BI0100001206
967.01Guniting the damaged part of Slab after removing / old guniting / part of defective concrete, cleaning the surface and exposed reinforcement thoroughly by sand blasting, spraying with epoxy @ 0.67 kg/sqm including cost of wire mesh fabrics 5cm X 5cm X No 10 gauge in first layer of guniting complete as per drawingsTechnical specifications Clause 2807 and as directed by Engineer.BI01010001010000000000000515BI0100001207219sqm
977.02Clearing of culvert vents and river/stream bed on U/S and D/S of culvert by removing deposited debris, silt, soil and any other foreign material and including safe disposal of removed material as per Technical Specifications Section 300.BI01010001010000000000000515BI0100001208586cum
987.03Repairs to loose boulder pitching/ revetment to embankment slopes near abutments by removal, stacking of existing boulders and relaying stacked boulders properly after increasing height of earthfill around abutments as per Technical Specifications Clause 2504BI01010001010000000000000515BI010000120948cum
997.04Providing and laying in position hand packed boulder pitching on slopes of embankment, in front of abutments complete as per drawings and Technical Specifications Clause 2504 or as directed by Engineer.BI01010001010000000000000515BI010000121020cum
1007.05Cleaning and grubbing under culvert and in river/stream bed both U/S and D/s of existing culvert for a distance specified by the Engineer including cutting , removing and disposing of all materials such as trees, bushes, shrubs, stubs, roots, grass, weeds etc. as per Technical Specifications Section 200.BI01010001010000000000000515BI010000121150sqm
1017.06Providing and laying filter media below hand packed boulder pitching complete as per drawings and Technical Specifications Clause 2504 or as directed by Engineer.BI01010001010000000000000515BI010000121238cum
1027.07Providing ruled pointing in 1:3 Cement sand mortar in course rubble masonry in abutments, piers and wing walls, complete as per Clause 1405.6 of Technical Specifications.BI01010001010000000000000515BI0100001213187sqm
1037.08Dismantling the railing/parapet and kerb of the existing culvert without causing any structural damage to other parts of the bridge including all labour, tool and its disposal complete as per Technical Specifications Section 2800.BI01010001010000000000000515BI0100001214204Lm
1047.09Providing cement concrete crash barrier in M-40 grade reinforcement and G.I. pipe complete as per drawing & MORT&H Specifications Sections 1500, 1600, 1700, 2200, 811 and Clause 809.BI01010001010000000000000515BI0100001215197Lm
1057.1Providing HYSD reinforcement of Grade Fe500D for dowel bars; repair of RCC superstructure & substructure complete as per Technical Specifications Section 1600 and 2800.BI01010001010000000000000515BI01000012161MT
1067.11Providing and laying new Drainage spout including making the joint of drainage spout with slab water tight with non shrink free flow cement grout and drilling hole in RCC slab and cutting chase in slab of required size for fixing drainage spout complete as per Technical Specification Clause 2705.BI01010001010000000000000515BI010000121764Nos.
1077.12Sealing of cracks by injecting grout through nipples including cleaning the affected area complete as per Section 2800 of MoRT&H Specifications.BI01010001010000000000000515BI0100001218
1087.121Epoxy grouting In RCC/PCC substructure / superstructureBI01010001010000000000000515BI0100001219419Kg
1097.122Cement grouting In Course Rubble / brick MasonryBI01010001010000000000000515BI0100001220130Kg
1107.13Removal of existing asphaltic wearing coat including disposal with all lift and lead.BI01010001010000000000000515BI0100001221928sqm
1117.14Laying of 65 mm thick wearing coat consisting of 40 mm thick bituminous concrete overlaid with 25 mm thick mastic asphalt over newly laid profile corrective course / existing deck on existing bridge deck including providing necessary camber/super elevation to match with highway profile adjacent to bridge complete as per Technical specification Section 2700.BI01010001010000000000000515BI0100001222928sqm
1127.15Dismantling and replacement of Burried Expansion joint As per Technical specification Section 2600 & 202BI01010001010000000000000515BI010000122382Lm
1137.16Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications section 2800 including subsequent :cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy:In RCC/PCC substructure / superstructureBI01010001010000000000000515BI0100001224110Nos.
1147.17Surface Coating to the concrete to inhibit the ingress of chlorides or carbon dioxide. As per Technical specification Section 2808 & 2809BI01010001010000000000000515BI01000012252620sqm
1157.18Removal of defective concrete, cleaning the surface thoroughly, applying the shotcrete mixture mechanically with compressed air under pressure, comprising of cement, sand, coarse aggregates, water and quick setting compound in the proportion as per clause 2807.1., sand and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012 respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite not less than 2000 kg/cum, strength not less than 25 Mpa and workmanship conforming to Clause 2807.6.BI01010001010000000000000515BI0100001226108sqm
1167.19Patching of damaged concrete surface with polymer concrete and curing compounds, initiator and promoter, available in present formulations, to be applied as per instructions of manufacturer and as approved by the Engineer. As per Technical specification Section 2804BI01010001010000000000000515BI0100001227205sqm
1177.2Eproxy bonding of new concrete to old concrete As per Technical specification Section 2805BI01010001010000000000000515BI0100001228205sqm
1187.21Providing and painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces (as primary & finishing paint) as per Technical specification 1906.1.1BI01010001010000000000000515BI0100001229148sqm
1197.22Providing and laying in position 65 mm thick wearing coat consisting of 40 mm thick bituminous concrete overlaid with a 25 mm thick layer of mastic asphalt all complete as per drawings and Technical Specifications Clause 2702.BI01010001010000000000000515BI010000123080cum
1207.23Repair of RCC Railing/ RCC Parapet (Carrying out repair of RCC M30 railing/ Parapet to bring it to the original shape.) all complete as per directed by engineer and Technical Specification 202, 2703, 1500, 1600 & 1700BI01010001010000000000000515BI010000123134Lm
1218BILL-7 DRAINAGE & PROTECTION WORKSBI01010001010000000000000515BI0100001232
1228.01Providing and constructing RCC Covered drain / Line drain complete as per drawing and Technical Specification Clause 309BI01010001010000000000000515BI0100001233
1238.011Earthwork in excavation in all types of soil and roack with all lifts and leads complete as per Drawings and Technical Specification Clause 304.BI01010001010000000000000515BI010000123427527cum
1248.012Providing & Laying Plain cement concrete of M15 Grade in leveling course complete as per drawing and Technical specification section 1500 & 1701BI01010001010000000000000515BI01000012353486cum
1258.013Providing & Laying Reinforced Cement Concrete of M25 Grade complete as per Drawing and Technical Specification section 1500 & 1700.BI01010001010000000000000515BI010000123613595cum
1268.014Supplying, fitting and placing HYSD bar reinforcement complete as per drawing and technical specifications Specification 1600.BI01010001010000000000000515BI0100001237633MT
1278.015Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/ return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards draining face. including all cost and conveyance of materials labour charges etc complete as per drawing and Technical Specifications Clause 2706.BI01010001010000000000000515BI010000123813944Lm
1288.016Providing inlet pipes of 100 mm dia PVC pipe for draining out water from kerb face to drain complete as per drawing and as directed by the Engineer.BI01010001010000000000000515BI01000012396972Nos.
1298.017Providing and Fixing 150mm x 150mm GI grating complete as per drawing and as directed by the Engineer.BI01010001010000000000000515BI01000012406972Nos.
1308.018Providing, precasting, transportation and placing in position precast concrete trapezoidal drain in M-25 grade on M-10 grade foundation 50 mm thick, foundation concrete laid manually all complete as per drawing and Technical Specification sections 309, 1500,1700, 2100 and 2200.BI01010001010000000000000515BI01000012413610Lm
1318.02Earthwork in excavation necessary for construction of Retaining Wall in all types of soil all complete as per Technical Specification Clause 301.BI01010001010000000000000515BI01000012426480cum
1328.03Providing and constructing Plain cement concrete in drain, stilling basin, Breast wall and toe wall complete as per drawing and technical specification clause 309 and sections 1500 and 1700.BI01010001010000000000000515BI0100001243
1338.031Breast wall M-10BI01010001010000000000000515BI0100001244630cum
1348.032Retaining Wall-M15BI01010001010000000000000515BI0100001245300cum
1358.033M20BI01010001010000000000000515BI0100001246
1368.034FoundationBI01010001010000000000000515BI01000012472214.8cum
1378.035Sub StructureBI01010001010000000000000515BI01000012481986cum
1388.04Providing and constructing Reinforced cement concrete of M35 in foundation in Retaining Wall complete as per drawing and Technical Specification Clause 309 and sections 1500, 1700 and 2100BI01010001010000000000000515BI01000012491000cum
1398.05Providing and constructing Reinforced cement concrete M35 sub structure in Retaining Wall complete as per drawing and Technical Specification Clause 309 and sections 1500, 1700 and 2200BI01010001010000000000000515BI0100001250800cum
1408.06Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/ return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards draining face. including all cost and conveyance of materials labour charges etc complete as per drawing and Technical Specifications Clause 2706.BI01010001010000000000000515BI01000012511110Lm
1418.07Supplying , fitting and placing HYSD bar reinforcement of foundation complete as per drawing and Technical specification 1600.BI01010001010000000000000515BI010000125260MT
1428.08Supplying , fitting and placing HYSD bar reinforcement of sub-structure complete as per drawing and Technical specification 1600.BI01010001010000000000000515BI010000125350MT
1438.09Providing, fixing and erecting tubular steel railing complete as per drawing and Technical Specifications Clause 800BI01010001010000000000000515BI01000012541030Lm
1448.1Providing and laying of Filter media behind walls of retaining wall with granular materials/stone crushed aggregates complete as per drawing and Technical Specification Clause 2504.2.2.BI01010001010000000000000515BI01000012551053.28cum
1458.11Providing and laying PCC M20 Parapet wall over Toe wall complete as per drawing and Technial Specification section 1500,1600 and 1700.BI01010001010000000000000515BI010000125663cum
1469BILL-9 ROAD APPURTENANCESBI01010001010000000000000515BI0100001257
1479.01Providing RCC M-15 Boundary Stone of standard design as per IRC:25-1957, fixing in CC M-15, including finishing and lettering including painting etc all complete as per Technical Specification Clause 807.BI01010001010000000000000515BI0100001258230Nos.
1489.02Providing and fixing Distance Indicator post including painting and printing etc all complete as per Technical Specification Clause 805 and IRC 26.BI01010001010000000000000515BI0100001259
1499.0215th Km stoneBI01010001010000000000000515BI01000012604Nos.
1509.022Km stoneBI01010001010000000000000515BI010000126119Nos.
1519.023200 m stoneBI01010001010000000000000515BI010000126290Nos.
1529.03Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with suitable back supporting frame of MS angle 25x25x3 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over suitable primer and as per approved drawing and clause 801 including lettering symbols etc.BI01010001010000000000000515BI0100001263
1539.03160 cm Equilateral triangle \n(Cautionary Sign Boards)BI01010001010000000000000515BI0100001264703Nos.
1549.032STOP Sign OctagonalBI01010001010000000000000515BI0100001265107Nos.
1559.03360 cm Circular ( Mandatory Sign Boards )BI01010001010000000000000515BI0100001266160Nos.
1569.034State Route Marker/Direction signBI01010001010000000000000515BI010000126733.3sqm
1579.035Advance Direction sign <0.9sq.m Direction and Place Identification Signs upto 0.9 sqm Size Board (Type XI)\nProviding and fixing of direction and place identification retro-reflectorised sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area not exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on GI pipe pole 50mm NB confirming to IS 1239 firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 cm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etcBI01010001010000000000000515BI010000126814.08Sqm
1589.036Advance Direction sign >0.9sq.m Direction and Place Identification Signs with size more than 0.9 sqm size Board (Type XI)\nProviding and fixing of direction and place identification retro-reflectorised sign with 10 years warranty manufactured as per IRC :67 made of ASTM D 4956-09 Type XI micro prismatic grade sheeting fixed over aluminium sheeting, 2 mm thick/ aluminium composit material sheeting 4 mm thick with area exceeding 0.9 sqm, with suitable back supporting frame of MS angle 40x40x6 and supported on suitably designed GI pipe pole not less than 50mm NB , 2 Nos. confirming to IS 1239, firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete min size 45 cm x 45 cm x 60 cm, 60 mm below ground level including painting all exposed surface with 2 coats of epoxy painting over epoxy primer and as per approved drawing and clause 801 including lettering symbols etc.BI01010001010000000000000515BI010000126915Sqm
1599.037Flag type Direction signBI01010001010000000000000515BI010000127030Nos.
1609.038Hazard Marker signBI01010001010000000000000515BI0100001271255Nos.
1619.039Chevron sign (50cmx60cm)BI01010001010000000000000515BI0100001272564Nos.
1629.04Bus stop (600x800)BI01010001010000000000000515BI010000127338Nos.
1639.05Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 .The finished surface to be level, uniform and free from streaks and holes.as per drawing and Technical specification 803BI01010001010000000000000515BI0100001274
1649.051centre line/edge line/ transverse marking and any other markings.BI01010001010000000000000515BI01000012757000sqm
1659.052Pedestrian crossingBI01010001010000000000000515BI01000012762910sqm
1669.053Straight ArrowsBI01010001010000000000000515BI0100001277310Nos.
1679.054Left and Right Turn ArrowsBI01010001010000000000000515BI010000127818Nos.
1689.055Straight and Left/Right Turn ArrowsBI01010001010000000000000515BI0100001279196Nos.
1699.06Providing and fixing reflective road studs (Raised Pavement Marker) of ' category A' made out of ASA/HIPS/ABS moulded body with shanks and conforming to ASTM D 4280, strong enough to support a load of more than 13.635 T when tested in accordance with ASTM D 4280, reflective panel confirming to ASTM D 788, and reflectivity conforming to clause 804.4. including installation, drilling, fixing with adhesive etc. with 2 years warranty for the road stud as well as for in field performance as per clause 804.7.3\nRoad Markers/Road Stud with Lense ReflectorBI01010001010000000000000515BI01000012808500Nos.
1709.07Supplying and installation of delineator (Road way indicators) posts 80- 100cm high above ground level, pained black and white in 15 cm wide strips, fitted with min. 80 x 100 mm rectangular or 75 mm dia circular retro reflectorised panels at the top with minimum visibility of 300m with provisions to prevent edge lifting and vandalisam, and conforming to clause 806 , IRC-79 and the drawings including fixing to ground (The deleniator shall be of approved type as per specification)BI01010001010000000000000515BI01000012813780Nos.
1719.08Providing utility duct 600mm dia RCC pipe complete as per Technical Specification section 1900 and as directed by the Engineer.BI01010001010000000000000515BI0100001282316.35Lm
1729.09Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2 m centre to centre, complete as per approved drawings complete and as per Technical Specification Section 809.BI01010001010000000000000515BI01000012832900Lm
1739.1Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 325 mm high in M 20 grade PCC on M-10 grade foundation 100 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per Technical Specification Clause 409 and IRC: 86-2018BI01010001010000000000000515BI01000012847800Lm
1749.11Providing and constructing cement concrete mountable type kerb laid width 50 and 250 mm respectively, 200 mm high in M 20 grade PCC on M-10 grade foundation 100 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per Technical Specification Clause 409 and IRC: 86-2018BI01010001010000000000000515BI01000012851145Lm
1759.12Providing and painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces (as primary & finishing paint) as per Technical specification 1906.1.1.BI01010001010000000000000515BI01000012864959sqm
1769.13Providing and erecting a \"W\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long, complete as per drawing and Technical specification 811.3.1.2 and as per IRC 119-2015BI01010001010000000000000515BI0100001287476Lm
1779.14Construction of footpath by providing compacted granular sub base as per clause 401 and 50mm thickness with cement concrete grade M20 including provision of all drainage arrangements.Footpaths and Separators and precast concrete blocks complete as per drawing and Technical specification clause 410.3BI01010001010000000000000515BI0100001288
1789.141PCC M20BI01010001010000000000000515BI010000128972.15cum
1799.142GSBBI01010001010000000000000515BI0100001290360.75cum
1809.15Construction of traffic hump as per IRC 99 2018, with BC and tack coat as all completed as per engineer in charge.BI01010001010000000000000515BI0100001291103Nos.
18110BILL-10 BUS SHELTERBI01010001010000000000000515BI0100001292
18210.1Construction of passenger shelter at bus bays as per Drawing and Technical Specification Sections 300, 800, 1000, 1300,1500,1600,1700,1900 & 2300.BI01010001010000000000000515BI010000129332Nos.
18310.2Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres \nCement Concrete Grade M-15 & M-20 - By Mechanical MeansBI01010001010000000000000515BI0100001294110cum
18411BILL-11 MAINTENANCE DURING CONSTRUCTIONBI01010001010000000000000515BI0100001295
18511.1Carrying out treatment and repairs to pot holes and any necessary patching to existing bituminous carriageway surfacing as per Technical Specifications Clause 3004.BI01010001010000000000000515BI01000012964873sqm
18612BILL-11 TEMPORARY DIVERSION WORKBI01010001010000000000000515BI0100001297
18712.01Construction of embankment with approved materials deposited at site from roadway cutting and drain excavation all complete as per Technical Specification Clause 305 and as directed by the Engineer.BI01010001010000000000000515BI01000012985874cum
18812.02Providing and laying granular sub-base all complete as per Technical Specification Clause 401 and as directed by the Engineer.BI01010001010000000000000515BI01000012992100cum
18912.03Providing and laying wet mix macadam (WMM) base with approved material complete as per Technical Specification Clause 406 and as directed by the Engineer.BI01010001010000000000000515BI01000013002192cum
19012.04Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base all complete Technical Specification Clause 502 and as directed by the Engineer.BI01010001010000000000000515BI01000013014895sqm
19112.05Providing and applying tack coat over granular surface with bitumen emulsion on the prepared bituminous/granular surface all complete as per Technical Specification Clause 503 and as directed by the Engineer.BI01010001010000000000000515BI01000013024895sqm
19212.06Providing and laying Premix Carpet complete as per Technical Specification Clause 508 and as directed by the Engineer.BI01010001010000000000000515BI01000013034895sqm
19312.07Construction of sub-grade and earthen shoulders with approved material deposited at site from roadway cutting and drain excavation all complete as per Technical Specification Clause 305 and as directed by the Engineer.BI01010001010000000000000515BI01000013041046cum
19412.08Providing, laying and jointing Hume pipes of 1200 mm dia for cross drainage works complete as per Technical Specification Section 2900 and as directed by the Engineer.BI01010001010000000000000515BI0100001305305Lm
19513BILL-13 ELECTRICAL AND MISCELLANEOUSBI01010001010000000000000515BI0100001306
19613.01Supply, installation, testing and commissioning of 8 M octagonal pole made of hot dip galvanized GI sheet 70mm top diameter,130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16mm suitable for wind speed as per IS 875 part III single arm bracket 0.5mt including foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 8 MetersBI01010001010000000000000515BI0100001307196Nos.
19713.02Supply, installation, testing and commissioning of 10M octagonal pole made of hot dip galvanized GI sheet 70mm top diameter,175mm bottom diameter thickness 3mm base plate dimensions of 275x275x16mm suitable for wind speed as per IS 875-part III single arm bracket 0.5mt including foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 10 MetersBI01010001010000000000000515BI010000130827Nos.
19813.03Supply, installation, testing and commissioning of 150W LED street light output greater than 105lumen/W 4000 – 6000 K with IP66 protection LED chip make cree/lumilled/NIchea with power factor greater than .95 at full load internal surge protection upto 8 kV and Aluminium pressure die cast powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than .98. RoHS complaint,duly wired up for use on 230V AC supply Driver compartment should be separately accessible for maintenance(LM 79 & 80 certificates from NABL accredited third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI0100001309196Nos.
19913.04Supply, installation, testing and commissioning of 200W LED street light output greater than 105lumen/W 4000 – 6000 K with IP66 protection LED chip make cree/lumilled/NIchea with power factor greater than .95 at full load internal surge protection upto 8 kV and Aluminium pressure die cast powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than .98. RoHS complaint,duly wired up for use on 230V AC supply Driver compartment should be separately accessible for maintenance(LM 79 & 80 certificates from NABL accredited third party lab to be produced mentioning chip manufacturer)BI01010001010000000000000515BI010000131027Nos.
20013.05Supply and laying of one number PVC insulated PVC sheathed armored aluminum power cable of 1.1KV grade of the following sizes in the existing RCC/HUME/STONE WARE/GI/DWC pipe as required. 4 core 16 sq.mmBI01010001010000000000000515BI01000013118325Lm
20113.06Providing and laying earth connection from earth electrode with 6 SWG dia G.I Wire in 15mm dia G.I pipe from earth electrode including connection with G.I thimble excavation and refilling as required.BI01010001010000000000000515BI0100001312261Nos.
20213.07Supplying, testing, installing and commissioning of 40mm HDPE pipe for underground cable layingBI01010001010000000000000515BI01000013136750Lm
20313.08Supply, erection of 8 way feeder pillar outdoor type panel complete with accessories and concrete foundation, service cable termination, testing and commissioning in completeBI01010001010000000000000515BI01000013146Nos.
20413.11Fees to be remitted to Electrical Inspectorate/KSEB/meter testing lab/ fire & rescue service Department(Actual amount incurred for the above items will be reimbursed on production of original Receipts)BI01010001010000000000000515BI01000013151L S
20513.12Earthing with G.I earth pipe 4.5 metre long, 40mm dia. including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.BI01010001010000000000000515BI010000131617Nos.
20614BILL-14 GENERAL ITEMBI01010001010000000000000515BI0100001317
20714.01Procure (purchase) and supply brand new vehicle for employer and engineer including registration ,full comprehensive insurance(first yr),number plate, road tax..etc a} Innova Type 2 Vehicle, complete and As Per Technical Specification 122BI01010001010000000000000515BI01000013181Nos.
20814.02Vehicles running cost of fuel and POL for 3000 Km.and as per Technical Specifications 122BI01010001010000000000000515BI010000131918Veh-Month
20914.03Maintenance of Type 2 Vehicles (Provided by Employer) including full comprehensive insurance, Driver's salary repairs including replacement of worn tyres, services as per manufacturer’s recommendation etc. and as per Technical specification 122BI01010001010000000000000515BI010000132018Veh-Month
21015BILL-15-ENVIRONMENTAL SAFETY, HEALTH SAFETY AND EMP COST\nBI01010001010000000000000515BI0100001321
21115.1Resources allocated to ESHS management all completed as per ESHS Clause 4BI01010001010000000000000515BI0100001322
21215.11ESHSE Manager having 10 years in designing and monitoring the implementation of ESHS management plans for construction works and In Similar Works Experience for 5 yearsBI01010001010000000000000515BI010000132318Month
21315.12ESHS Supervisor (one ESHS supervisor for each shift on each Project Area, respecting the provisions of 4.1.3), total work experience 5 years including 1 year similar work experienceBI01010001010000000000000515BI010000132418Month
21415.13Community Liaison Officer having total experience 5 years [Fluency in local languages should be mandatory for this position]BI01010001010000000000000515BI010000132518Month
21515.2Implementation of the Health and Safety Plan all completed as per ESHS Clauses (1, 9, 21 to 25, 27 to 35, 37, 38)BI01010001010000000000000515BI0100001326
21615.21Installation silt fencing for control sediment into nearby surface water bodies as listed in section 5.3.1.5 Risks & Impacts on Water Resources of ESIA report, including regular maintenance for entire construction period and removal of those fence on completion of work near surface water bodiesBI01010001010000000000000515BI01000013273580running meter
21715.22Provide and maintenance of personal protective equipment including nosal mask for prohibition of spread of Covid-10, as required, to all personnel, visitors or third parties entering a Project Area are equipped with Personal Protection Equipment (PPE) pursuant to the practices and standards specified in ESHS Clause 9BI01010001010000000000000515BI010000132818month
21815.23Medical Check Up - The Contractor shall organises medical check-ups carried out by a doctor or an appropriately qualified nurse for all Contractor’s Personnel prior to the initial mobilisation to the Project Area to check aptitude for the work.\n- 32.2. Hearing tests are conducted for the Contractor’s personnel exposed to noise levels above 80 dB(A) in order to establish initial audiograms. Annual test shall be carried out as per advise of the Engineer.\n- Covid-19 test to the Contractor's personal as and when requiredBI01010001010000000000000515BI01000013296Quarterly
21915.24Provide and maintain first-aid provisions on any work site, including: suitably stocked first-aid kits; a person, respectively an adequate number of staff appointed and trained to take charge of first-aid arrangements and ensure that staff and workers are informed about first-aid arrangements.BI01010001010000000000000515BI010000133018month
22015.3Accommodation, drinking water, meals and transportation of staff all completed as per ESHS Clauses 36, 40, 41BI01010001010000000000000515BI0100001331
22115.31Accommodation, drinking water, meals and transportation of staff(*)\nContractor shall provide to his personnel safe drinking water at all project areas. The quantity and quality of this water complies with the standards of the World Health Organization at supply pointsBI01010001010000000000000515BI01000013321Lump Sum
22215.32Provide and maintain accommodation for non-resident Personnel in a camp or an alternative structure outside of the Project Areas, such as a hotel or rented house, will comply with the conditions of the present ESHS Sub-Clause in pursuance of Sub-Clause 6.6 of the CC. The quality of accommodation shall comply with ESHS clause 40.2BI01010001010000000000000515BI01000013331Lump Sum
22315.33Contractor provides meals at a reasonable cost or free of charge to its Contractor’s Personnel per shift in a canteen area and according to a procurement system which complies with the provisions of this ESHS Specifications Sub-ClauseBI01010001010000000000000515BI01000013341Lump Sum
22415.4Training and local recruitment management costs all completed as per ESHS Clauses 8, 39BI01010001010000000000000515BI0100001335
22515.41Contractor shall organize training sessions for his personnel in two-folds: introductory sessions for starting work at the Project Area, and technical training as required in relation to the execution of the works as per ESHS Clause 8.3 and 8.5BI01010001010000000000000515BI01000013366Quarterly
22615.42The Contractor will take out and maintain the necessary insurance to cover the cost of the sanitary repatriation of its Contractor’s PersonnelBI01010001010000000000000515BI01000013371Lump Sum
22715.5Protection of adjacent areas, biodiversity, prevention of erosion and wastewater management all completed as per ESHS Clauses 10, 11, 12, 17, 18BI01010001010000000000000515BI0100001338
22815.51Protection of adjacent areas, prevention of erosion and wastewater management - The Contractor shall take the necessary measures to ensure that pollution to air, water or land is prevented or, where this is not possible, reduced and mitigated as far as practicable during the construction phase. If required in the PA-ESMP the Contractor will develop a pollution prevention Plan for managing e.g. atmospheric emissions and dust, e.g. noise and vibrations,BI01010001010000000000000515BI01000013391Lump Sum
22915.52Installation and maintenance of Oil Interceptor (refer schematic diagram at Annexure 8.4 of ESIA Report) for removal of oil and grease at vehicle wash bayBI01010001010000000000000515BI01000013401Lump sum
23015.53Sprinkling of water for suppression of dust all along the construction areas for the entire construction periodBI01010001010000000000000515BI01000013411Lump Sum
23115.6Traffic, noise and atmospheric emissions management, land take all completed as per ESHS Clauses 13, 14, 42, 43, 44BI01010001010000000000000515BI0100001342
23215.61Contractor shall carry out or contracting the monitoring of the effluent quality pursuant to the present ESHS Specifications by external accredited agency for sampling and laboratory analysis and submit the analysis results the engineer.BI01010001010000000000000515BI01000013436Sample
23315.62Contractor shall carry out monitoring of environmental attributes of as per environmental monitoring plan for Construction phase\nBI01010001010000000000000515BI0100001344
23415.621Ambient Air QualityBI01010001010000000000000515BI010000134510number
23515.622Surface Water QualityBI01010001010000000000000515BI010000134610number
23615.623Ground Water QualityBI01010001010000000000000515BI010000134710number
23715.624Noise LevelBI01010001010000000000000515BI010000134810number
23815.625Soil QualityBI01010001010000000000000515BI01000013496number
23915.626Contractor shall carry out monitoring of environmental attributes of as per environmental monitoring plan for 1 year of operational phase/Defect Liability Period\nBI01010001010000000000000515BI0100001350
24015.627Ambient Air QualityBI01010001010000000000000515BI01000013513number
24115.628Surface Water QualityBI01010001010000000000000515BI01000013526number
24215.629Ground Water QualityBI01010001010000000000000515BI01000013532number
24315.63Noise LevelBI01010001010000000000000515BI01000013543number
24415.631Soil QualityBI01010001010000000000000515BI01000013552number
24515.7Waste and hazardous products management all completed as per EHSH Clauses 15, 26BI01010001010000000000000515BI0100001356
24615.71Identifying, collecting, transporting and treating all waste produced on the Project Areas..BI01010001010000000000000515BI01000013571Lump Sum
24715.8Vegetation clearing and site rehabilitation all completed as per ESHS Clauses 16, 19, 20BI01010001010000000000000515BI0100001358
24815.81Site rehabilitation - the Contractor will rehabilitate all Project Areas and landscapes disturbed by the works, to their original condition where possible upon completion of construction and prior to the provisional acceptance of the works. Close collaboration with all statutory stakeholders will be conducted in cooperation with the Employer during the reinstatement. This will include all temporarily acquired sites including borrow areas, quarry areas, camp site, storage areas, diversions, etc.BI01010001010000000000000515BI01000013591Lump Sum

AI Tender Summary

OUR REF NO 26923885
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 29-03-2021
Authority
Authority Name Kerala State Transport Project
Work Description Rehabilitation And Up Gradation Of Vadayar Chandappalam Mulakkulam Road And Vadayar Kallattippalam Muttuchira Road Length Of 22 . 476 Km In Kottayam District
Basic Detail
Tender No KSTP/KfW/RKI PKG-IV/Work/Rd-2
Bidding Type Tender
Location
City Kottayam
State Kerala
Key Dates
Publish Date 01 Mar 2021
Submission Date 29 Mar 2021
Open Date 29 Mar 2021
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
TenderdrawingDCS.pdf
Biddoc.pdf
Tendernotice_1.pdf
Tenderdrawings_2.pdf
Tenderdrawings_1.pdf
Streetlightingpole.pdf
D02947BE-2C5C-4A04-AA82-8A437D44BE6C.html
ESIAreport.pdf
BOQ_588107.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 01, 2021
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 29, 2021
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 29, 2021
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 29, 2021

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

TenderdrawingDCS.pdf

pdf

Biddoc.pdf

pdf

Tendernotice_1.pdf

pdf

Tenderdrawings_2.pdf

pdf

Tenderdrawings_1.pdf

pdf

Streetlightingpole.pdf

html

D02947BE-2C5C-4A04-AA82-8A437D44BE6C.html

pdf

ESIAreport.pdf

xls

BOQ_588107.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders