Tender For Job Order, GarrisonEngineer West-Delhi

Military Engineer Services-MES has published Tender For Job Order. Submission Date for this Tender is 22-02-2021. Consultancy Service Tenders in GarrisonEngineer West Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

26913184
Corrigendum : Tender For Job Order
Open Tender
Indian
Delhi
GarrisonEngineer West
22-02-2021

Tender Details

Tender For Job Order - Consultancy For Rehabilitation And Restrengthening Of Bldg No P-01 ( Main Bldg ) At Hq Dgbr Which In+A1cludes :- . ( A ) Survey For Condition Of Bldgs : To Carry Out A Detailed Visual Inspection For Surface Damages, Cracks, Seepage, Local Weekness And To Identify Locations Of Structural And Functional Distress And Locations Suspected To Develop Structural And Functional Distress Of The Buildings. ( B ) Non Destructive Test ( Ndt ) : Non Destructive Evaluation Of The Structural Elements By Various Tests As Required Locations And Structural Assessment Based On These Parameters. . ( C ) Rebound Hammer Test : To Check The Compressive Strength Of Concrete As Per Is-13311 1992 Part-Ii. ( D ) Ultrasonic Pulse Velocity ( Upv ) : As Per Is-516 Measurements On The Rcc Elements To Find Out The Quality Of Concrete.. ( E ) Ferroscanning: To Locate The Rcc Elements And Check Steel Bars And Its Details Like Spacing Cover And Approx Diameter ( F ) Carbonation : To Check The Penetration Depth Of Carbonation In Concrete. ( G ) Core Cutting & Compressive Strength Test: Take Out The Sample Of Cylindrical Concrete And Carryout Min Six Test Samples Of Compressive Strength Test. ( H ) Corrosion Monitoring : To Measure The Risk And Rate Of Corrosion Of Steel In Concrete By Half Cell Potential Of Reinforcement To Assess The Risk Of Corrosion. ( J ) Concrete Cover Measurement : Measurement Of Thickness Of Concrete Cover To Reinforcement Bars By Cover Meter Test. ( K ) Chemical Analysis : To Draw Samples Of Concrete And Carry Out Checical Analysis Of The Sample Including Measurement Of Chloride Content ( L ) Thermographic Imaging. For Inspection Of Moisture / Dampness In The Structures For Pin Pointing The Moisture Trail. ( M ) Structural Evaluation And Retrofitting Scheme This Would Include Assessment Of Adequacy Existing Structural Components And Providing Retrofitting Scheme To Strengthen The Inadequate Structural Components Including Repair Methodology, Preparation Of Bill Of Quantities ( Boq ) Specifications For The Work. Report / Boq / Drawing On Structural Issue Should Be Vetted By Iit / Nit. Report Must Be Submitted In Quadruplicate.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Feb-2021 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-02-2021

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work : JOB ORDER
Item Description Item Code / Make Quantity Units
1 Consultancy for Rehabilitation and restrengthening of Bldg No P-01 (Main bldg) at HQ DGBR which in+A1cludes :- . (a) Survey for Condition of Bldgs : To carry out a detailed visual inspection for surface damages, cracks, seepage, local weekness and to identify locations of structural and functional distress and locations suspected to develop structural and functional distress of the buildings. (b) Non Destructive Test(NDT): Non destructive evaluation of the structural elements by various tests as required locations and structural assessment based on these parameters. . (c) Rebound Hammer Test : To check the compressive strength of concrete as per IS-13311 1992 Part-II. (d) Ultrasonic Pulse Velocity (UPV): As per IS-516 measurements on the RCC elements to find out the quality of concrete.. (e) Ferroscanning: To locate the RCC elements and check steel bars and its details like spacing cover and approx diameter (f) Carbonation : To check the penetration depth of carbonation in concrete. (g) Core Cutting & Compressive Strength Test: Take out the sample of cylindrical concrete and carryout min six test samples of compressive strength test. (h) Corrosion Monitoring : To measure the risk and rate of corrosion of steel in concrete by half cell potential of reinforcement to assess the risk of corrosion. (j) Concrete Cover Measurement : Measurement of thickness of concrete cover to reinforcement bars by cover meter test. (k) Chemical Analysis : To draw samples of concrete and carry out checical analysis of the sample including measurement of chloride content (l) Thermographic Imaging. For inspection of moisture/dampness in the structures for pin pointing the moisture trail. (m) Structural Evaluation and Retrofitting Scheme This would include assessment of adequacy existing structural components and providing retrofitting scheme to strengthen the inadequate structural components including repair methodology, preparation of bill of quantities (BOQ) specifications for the work. Report/BOQ/Drawing on structural issue should be vetted by IIT/NIT. Report must be submitted in quadruplicate. item1 1 Complete Job