Construction Of Rajiv Gandhi Multipurpose Sports Stadium At Katasni Shimla Sh Providing Networking Wifi Therein, SHIMLA-Himachal Pradesh

Public Works Department-PWD has published Construction Of Rajiv Gandhi Multipurpose Sports Stadium At Katasni Shimla Sh Providing Networking Wifi Therein. Submission Date for this Tender is 26-02-2021. Stadium Tenders in SHIMLA Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

26908354
Construction Of Rajiv Gandhi Multipurpose Sports Stadium At Katasni Shimla Sh Providing Networking Wifi Therein
Open Tender
Indian
Himachal Pradesh
SHIMLA
26-02-2021

Tender Details

Construction Of Rajiv Gandhi Multipurpose Sports Stadium At Katasni Shimla Sh Providing Networking Wifi Therein

Key Value

Document Fees
INR 500 /-
EMD
INR 38300.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:C/O Rajiv Gandhi Multipurpose Sports Stadium at Katasni Shimla.(SH-Providing Networking & Wifi therein).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Supply Installation, Testing and Commissioning of Network Switch L2, 24 x 10/100/1000 + 4 x Gigabit SFP (2 combo), Switching capacity : 56 Gbps Forwarding performance (64- byte packet size) : 38.69 Mpps, MAC address table: 16K entries, 4096 active vlans, support for jumbo frames, SNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, TFTP, SSH, CLI, Layer 3 switching, Layer 2 switching, DHCP support, VLAN support, IGMP snooping, syslog support, DoS attack prevention, port mirroring, DiffServ support, weighted round-robin (WRR) queuing, broadcast storm control, IPv6 support, multicast storm control, unicast storm control, firmware upgradable, Spanning Tree Protocol (STP) support, Auto SmartPorts, RAM 512Mb, flash memory 256mb, Min Operating temp: 32 °F, Max operating temp: 104 °F. Humidity: 10-90%(non-condensing), complete in all respect Make: Brocade/ Cisco / Juniper or any equivalent approved by engineer in charge.\n\n\n 4 each
2 2 Supply Installation, Testing and Commissioning of Network Switch L2, (PoE) 24 x 10/100/1000 + 4 x Gigabit SFP (2 combo), PoE (24 ports, 195 W), Switching capacity : 56 Gbps Forwarding performance (64-byte packet size) : 38.69 Mpps, MAC address table: 16K entries, 4096 avtive vlans, support for jumbo frames, SNMP 1, RMON 1, RMON 2, RMON 3, RMON 9, Telnet, SNMP 3, SNMP 2c, HTTP, HTTPS, TFTP, SSH, CLI,\nLayer 3 switching, Layer 2 switching, DHCP support, VLAN support, IGMP snooping, syslog support, DoS attack prevention, port mirroring, DiffServ support, weighted round- robin (WRR) queuing, broadcast storm control, IPv6 support, multicast storm control, unicast storm control, firmware upgradable, Spanning Tree Protocol (STP) support, Rapid Spanning Tree Protocol (RSTP) support, Multiple Spanning Tree Protocol (MSTP) support, Trivial File Transfer Protocol (TFTP) support, access control list (ACL) support, quality of service (QoS), jumbo frames support, MLD snooping, SNMP, RMON, SNTP, Cisco Discovery Protocol, Auto SmartPorts, RAM 512Mb, flash memory 256mb, AC 120/230 V (50/60 Hz). Min Operating temp: 32 °F, Max operating temp: 104 °F. Humidity: 10-90%(non-condensing), complete in all respect Make: Brocade/ Cisco etc or any atther approved make by engineer in charge. 4 each
3 3 Supply Installation testing and commissioning of Switch L3, interface: 24 x 10/100/1000 + 2 x 10GE copper/SFP+ combo + 2 x 10GE SFP+. Switching capacity: 128GBPS. Forwarding performance: 95.23Mpps. MAC address table sine: 16,000 entries. Routing protocol: RIPv2, VRRP, PBR, static IPv4/IPv6 routing. Should support: Stacking, flow control, Layer 2 switching, Layer 3 switching, VLAN support, IPv6 support, Spanning Tree Protocol (STP) support, Rapid Spanning Tree Protocol (RSTP) support, Multiple Spanning Tree Protocol (MSTP) support, access control list (ACL) support, quality of service (QoS), reset button, LACP support, Energy Efficient Ethernet, dynamic VLAN support (GVRP), advanced threat protection, IPv6 first- hop security, static routing, dynamic routing, policy based routing, sFlow, RSPAN, hardware redundancy. Compliant IEEE standards: 802.3, 802.3u, 802.3z, 802.1D, 802.1Q, 802.3ab, 802.3ae, 802.3an, 802.1p, 802.3x, 802.3ad (LACP),\n802.1w, 802.1x, 802.1s, 802.3az. RAM: 512MB, Flash: 256MB.\nPower: AC 120/230V (50/60 Hz). Operating Temp: Min/Max: 32°F (0°C)/122°F (50°C). Humidity range operating: 10-90% (noncondensing). complete in all respect Make: Brocade/ Cisco / Juniper or any equivalent approved by engineer in charge. 1 each
4 4 Supply, Installation, Testing and Commissioning of 1G Single mode LC SFP transceiver, complete in all respect. Make: Brocade/ Cisco /Juniper or any other make approved by engineer in charge.\n 8 each
5 5 Supply, Installation, Testing and Commissioning of Wireless Controller for managing access point. Hardware or cloud controller. Make: Cisco / Ruckus / Quantum or any other make approved by engineer in charge. 1 each
6 6 Supply, Installation, Testing and Commissioning of Wireless Access Point. Make: Cisco / Ruckus / Quantum or any other make approved by engineer in charge 32 each
7 7 Supply, Installation, Testing and Commissioning of Straight 24 Port Patch Panel Keystone Type Loaded with Black color Information Outlet and rear Cable Manager. Different jacks of Cat 5/ Cat 6/ Cat 6A should be supported on the same panel for future upgrade. Port should be easily replaceable.\nConforms to IEC-60603-7 (603-7) for keystone-type, Snap-On apertures and supported with Connecting Hardware Keystone and ETL Verified complete in all respect . Make: Panduit / Rit / Systimax. 6 each
8 8 Supply, Installation, Testing and Commissioning of Cat-6 Patch Cord 1 meter, conforms to ANSI/TIA/EIA-568-2.D, ISO/IEC 11801 2nd edition and CENELEC EN50173 for Category 6/Class E tested on 600Mhz for better performance. Flame Retardant PVC Jacket, RoHS Compliant. Eight wires stranded bare copper, 7 x 0.19mm (24 AWG). ETL Verified and UL Listed complete in all respect . Make: Panduit / Rit / Systimax or any other make approved by engineer in charge. 109 each
9 9 Supply, Installation, Testing and Commissioning of Cat-6 Patch Cord 2 meter, conforms to ANSI/TIA/EIA-568-2.D, ISO/IEC 11801 2nd edition and CENELEC EN50173 for Category 6/Class E tested on 600Mhz for better performance. Flame Retardant PVC Jacket, RoHS Compliant. Eight wires stranded bare copper, 7 x 0.19mm (24 AWG). ETL Verified and UL Listed complete in all respect Make: Panduit / Rit / Systimax or any other make approved by engineer in charge. 70 each
10 10 Supply, Installation, Testing and Commissioning of UTP Cat 6 Cable Box, 23 AWG FR-PVC Jacket Blue, Cable should be tested on 600MHZ with 4 connector certificates. Cable should be ETL verified and UL Listed marking on Cable with RoHS compliant with ANSI/TIA-568-C.2, ISO/IEC 11801:2010 (Ed. 2.2), IEEE 802.3bt (PoE Type 4) support. Outer Dia - 6mm with 0.57mm Copper complete in all respect Make: Panduit / Rit / Systimax or any other make approved by engineer in charge. 1375 p/mtr
11 11 Supply, Installation, Testing and Commissioning of Fiber Patch Panel / LIU Modular Sliding Drawer Type 24 Port Blank LIU Loaded with 6 SC SM Duplex Adapter and 12 SC SM LSZH 1 Mtr Pigtails. LIU Should be Loaded with 24 Core Splice Tray and UL94V0 rated Cable spool for proper routing of Fiber Cable. Height: 44mm[1U], Width: 483mm[19”], Depth: 222mm, complete in all respect Make: Panduit / Rit / Systimax or any other make approved by engineer in charge.\n 6 each
12 12 Supply, Installation, Testing and Commissioning of Fiber Patch cord SC-LC Duplex, SM, LSZH, Length - 3m Length. Tensile - 100N with durability of 500times, the insertion loss change=0.2dB. Yellow LSZH Tight Buffered Cable, complete in all respect . Make: Panduit / Rit / Systimax or any other make approved by engineer in charge 8 each
13 13 Supply, Installation, Testing and Commissioning of 6 core OS2 10G supported Fiber Cable Single Mode Outdoor Multi Tube construction. Corrugated steel Tape and steel wire central strength Member. Min Tensile 1500N with Crush of 1000N. Cable Dia 9mm with Black HDPE for Direct burial. IEC60794-2- 20/21, IEC11801 ITU-T G.652D; G.657A1; G.657A2; G.657B3,EIA/TIA, RoHS Compliant complete in all respect Make: Panduit / Rit / Systimax\n 539 p/mtr
14 14 Supply, Installation, Testing and Commissioning of Rack wall mount 12U with front glass door, with two fans, PDU with 5x5A sockets, horizontal cable manager MS 1U 1No, mounting hardware 10pieces complete in all respect . Make: ComRack / Netrack / Valrack or any other make approved by engineer in charge. 5 each
15 15 Supply, Installation, Testing and Commissioning of Rack floor mount 27U (800 mm by 800 mm) with front glass door, with two fans, PDU with 5x16A sockets, horizontal cable manager MS 1U 1No, mounting hardware 20pieces complete in all respect Make:ComRack / Netrack / Valrack or any other make approved by engineer in charge\n 1 each
16 16 Supply and erection of PVC pipe25 mm dia ISI marked ( Medium ) surface mounted on wall or ceiling etc. including the cost of PVC bends , inspection boxes , iron clamps etc. complete in all respect . Make: AKG / BEC / Diplast / Kalinga. 810 p/mtr
17 17 Supply, Installation, Testing & Commissioning of 3 Core Power Cable 1.5 sq mm complete in all respect Make: Finolex,Hewells,polycab etc. 560 p/mtr
18 18 Supply, Installation, Testing and Commissioning of 3 KVA UPS On Line. With thirty-minute backup, complete in all respect . Make: APC /Emerson / Numeric or any other approved by engineer in charge.\n 1 each