}

Tender For Ridf Project, Mohanpur, Nadia-West Bengal

Bidhan Chandra Krishi Viswavidyalaya has published Tender For Ridf Project. Submission Date for this Tender is 01-03-2021. Kitchen Equipment Tenders in Mohanpur, Nadia West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

26903863
Tender For Ridf Project
Open Tender
Indian
West Bengal
Mohanpur, Nadia
01-03-2021

Tender Details

Tender For Ridf Project - Atomic Absorption Spectrometer :A Bench Top High Sensitive Atomic Absorption Spectrometer For Metal & Metalloids Analysis In Food & Agricultural Matrix Along With Software To Meet Global And Domestic Food Regulations Like Eu / Usfda / Japan / Fssai With Following Specifications.1. Type: Pc Controlled True Double Beam Atomic Absorption Spectrometer N2. Optics: Fully Sealed Narrow Beam Fibre Optics For Maximum Light Transmission For The Best Detection Limits With Least Maintenance.3. Wavelength Range: 190-900 Nm Or Better. N4. Monochromator: Computer Controlled Wavelength Selection With Diffraction Grating Of 1800 Lines / Mm Or More Using High Capability Detector And Focal Length Of 250 Mm Or More. N5. Slit: Automated Slit Selection With Settings Of 0.2 To 1.0 Nm Or Better.6. Detector: Wide Range Photomultiplier Tubes ( Pmt ) Covering Full Wavelength Range Or Solid State Detector, With Highest Quantum Efficiency. N7. Background Corrector: High Intensity / Speed Deuterium Background Corrector Or Better Technology.8. Hollow Cathode Lamps: Single Elements Hollow Cathode Lamp For Analysis For Various Elements Viz., Ag, Au, As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Zn. The Lamps Should Have Guaranteed 5000 Ma Hour Of Usage Time Or More. Super Lamps / Edl Lamps Should Also Be Provided For As And Hg.9. Lamps Positions: Minimum 8 Or More. N10. Furnace Atomizer:I. The Graphite Furnace Atomizer Alignment Should Be Fully Automatic.Ii. The Furnace Autosampler Must Be Integrated To Main Spectrometer With A Minimum Of 50 Sample Positions Or More And Should Have Auto-Dilution Capability For Standards And Samples.Iii. System Should Be Equipped With Pyrolytically Coated Graphite Tube For Rapid Furnace Heating Up To 2700 °C Or Better With Facility For Background Correction.Iv. Facility Of Imported Re-Circulating Chiller Of Appropriate Capacity For Cooling The Graphite Furnace. Nv. Matrix Modifier Options In Software And Supply Of Appropriate Modifier Solutions Along With The System Is Desirable. Vi. Variable Gas Flow For Furnace For Minimum Consumption, An External Protective Gas Stream Around The Graphite Tube To Maximize Tube Life.Vii. Accessibility To Run Different Elements Sequentially Without Manual Disturbance.Viii. Furnace Should Have Option Of Injection Temperature For Samples Like Oils And Organics. 11. Nebulizer: Adjustable Nebulizer With Inert Platinum / Iridium Capillary And Venturi For Corrosion Resistance.12. Burner: Air / Acetylene Burner With Corrosion Shield. System Should Come With 10 Cm Standard Titanium Burner Head For More Sensitivity. The System Should Have Software Controlled Automatic Vertical And Horizontal Alignment Of The Flame Burner Head For Optimum Light Transmission.13. Spray Chamber: Fluorinated And Acid Resistant High-Density Polyethylene For Aqueous And Organic Solutions. The Spray Chamber And Nebulizer Should Be Stack Design And Easy To Demount And User Cleanable. N14. Impact Bead: Externally Adjustable Impact Bead With Option For Inert Impact Bead For Samples With Hf.15. Sensitivity: Better Than 0.9 Absorbance With Precision Less Than 0.5% Rsd For 5 Ppm Cu Solution. N16. Hydride Generator: Should Be Continuous Flow / Mercury Hydride System / Flow Injection Type For High Sensitivity And Analysis Of All The Hydride Forming Elements.17. Vapor Generation Accessory: Modular Accessory For Determination Of Hydride Forming Elements Like Hg, As, Etc. Spare Hydride Modules Should Be Available.18. Software: User Friendly Updated Software Must Be Provided For Seamless Control Of The System. N19. Gas Cylinder: High Purity Acetylene, Argon And Other Required Gas Cylinders With Compatible Regulators And Necessary Tubes, Nuts And Ferules.20. Air Compressor: Oil Free Air Compressor21. Vent And Hood Assembly: Should Be Provided With Ducting ( 10 Ft. Or More ) Including Fitting And Fixing.22. Safety System: There Should Be Adequate Safety Features Required For Flame Control, Automatic Internal Gas Connections, Flame Shields And Protection, External Adjustment Of All Burner And Spray Chamber Controls. N23. Computer & Printer: Suitable Branded Pc ( Window Workstation With A 22” Monitor ) With Inbuilt Software & Tested For Fool Proof Operation To Operate The Instrument With Laser Jet Printer.24. Housing, Installation And Demonstration: Nthe Minimum Facility Like Tables, Electrical & Gas Panel Fittings, Dehumidifier Machine For Moisture Removing With Temperature-Humidity Controller [ Capacity: 20 L / Day ( 30?, 80% ) ; Area Coverage: Min. 3500 Cu Ft; Rotary Compressor; Circulating Air Volume-225 M3 / H; Automatic Mode ] Should Be Provided For Housing The System In The Laboratory; The Aas System Should Be Installed In Lab Free Of Cost; Onsite Demonstration & Training Of The System By The Application Specialist To Lab Personal Followed By Issuance Of Training Certificates To The Trainees. 25. Warranty & System Calibration: At Least 2 Years Onsite Warranty With One Year Amc Should Also Be Quoted Along With The Offer. Supplier Must Have Kolkata Based Service Facility With Factory Trained Engineer. System Calibration Should Be Done Once In Every Year With Issue Of Calibration Certificate As Per Iso: 17025 During The Warranty Period.26. Performance Certificate: Quoted Equipment Should Be Latest With Proof Of Installation Report / Performance Certificate From At Least 3 Users Of Reputed Organizations Is To Be Attached Along With Technical Bid.27. Emd: Rs. 30, 000 ( Rupees Thirty Thousand Only ) In The Form Of Bank Draft In Favour Of ‘Bidhan Chandra Krishi Viswavidyalaya’ Payable At Kalyani ( Ifsc: Sbin0001082 ) . Scan Copy Of The Draft Must Be Uploaded As The Supporting Document During Submission Of E-Tender. Without Emd Quotations Will Not Be Considered For Technical Or Financial Comparison. However, Bidders Are Requested Not To Send The Original Draft During Tendering Process. N

Key Value

Document Fees
Refer document
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:RIDF Project
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Equipment BI01010001010000000000000515BI0100001112
2 1.1 Atomic Absorption Spectrometer :A Bench Top high sensitive Atomic Absorption Spectrometer for Metal & Metalloids analysis in Food & Agricultural matrix along with software to meet global and domestic food regulations like EU/USFDA/Japan/FSSAI with following specifications.1. Type: PC controlled True Double beam Atomic Absorption Spectrometer\n2. Optics: Fully sealed narrow beam fibre optics for maximum light transmission for the best detection limits with least maintenance.3. Wavelength range: 190-900 nm or better.\n4. Monochromator: Computer controlled wavelength selection with diffraction grating of 1800 lines/mm or more using high capability detector and focal length of 250 mm or more.\n5. Slit: Automated slit selection with settings of 0.2 to 1.0 nm or better.6. Detector: Wide range Photomultiplier tubes (PMT) covering full wavelength range or Solid State Detector, with highest quantum efficiency.\n7. Background corrector: High intensity/speed deuterium background corrector or better technology.8. Hollow cathode lamps: Single elements hollow cathode lamp for analysis for various elements viz., Ag, Au, As, Cd, Cr, Cu, Fe, Hg, Mn, Ni, Pb, Zn. The lamps should have guaranteed 5000 mA hour of usage time or more. Super Lamps/EDL Lamps should also be provided for As and Hg.9. Lamps positions: Minimum 8 or more.\n10. Furnace Atomizer:i. The Graphite Furnace Atomizer alignment should be fully automatic.ii. The Furnace Autosampler must be integrated to main Spectrometer with a minimum of 50 sample positions or more and should have auto-dilution capability for standards and samples.iii. System should be equipped with pyrolytically coated graphite tube for rapid furnace heating up to 2700 °C or better with facility for background correction.iv. Facility of imported re-circulating chiller of appropriate capacity for cooling the Graphite Furnace. \nv. Matrix modifier options in software and supply of appropriate modifier solutions along with the system is desirable. vi. Variable gas flow for furnace for minimum consumption, an external protective gas stream around the graphite tube to maximize tube life.vii. Accessibility to run different elements sequentially without manual disturbance.viii. Furnace should have option of injection temperature for samples like oils and organics. 11. Nebulizer: Adjustable nebulizer with inert platinum/iridium capillary and venturi for corrosion resistance.12. Burner: Air/acetylene burner with corrosion shield. System should come with 10 cm standard Titanium burner head for more sensitivity. The system should have software controlled automatic vertical and horizontal alignment of the flame burner head for optimum light transmission.13. Spray chamber: Fluorinated and acid resistant high-density polyethylene for aqueous and organic solutions. The spray chamber and nebulizer should be stack design and easy to demount and user cleanable.\n14. Impact Bead: Externally adjustable impact bead with option for inert impact bead for samples with HF.15. Sensitivity: Better than 0.9 absorbance with precision less than 0.5% RSD for 5 ppm Cu solution.\n16. Hydride generator: Should be continuous flow/ mercury hydride system/flow injection type for high sensitivity and analysis of all the hydride forming elements.17. Vapor Generation Accessory: Modular accessory for determination of hydride forming elements like Hg, As, etc. Spare hydride modules should be available.18. Software: User friendly updated software must be provided for seamless control of the system.\n19. Gas cylinder: High purity Acetylene, Argon and other required gas cylinders with compatible regulators and necessary tubes, nuts and ferules.20. Air compressor: Oil Free Air Compressor21. Vent and Hood Assembly: Should be provided with ducting (10 ft. or more) including fitting and fixing.22. Safety system: There should be adequate safety features required for flame control, automatic internal gas connections, flame shields and protection, external adjustment of all burner and spray chamber controls.\n23. Computer & printer: Suitable branded PC (Window Workstation with a 22” Monitor) with inbuilt software & tested for fool proof operation to operate the instrument with Laser Jet Printer.24. Housing, Installation and Demonstration: \nThe minimum facility like Tables, Electrical & gas panel fittings, Dehumidifier machine for moisture removing with temperature-humidity controller [Capacity: 20 L/day (30?, 80%); Area Coverage: Min. 3500 cu ft; Rotary Compressor; Circulating Air Volume-225 m3/h; Automatic mode] should be provided for housing the system in the laboratory; The AAS system should be installed in lab free of cost; Onsite Demonstration & Training of the system by the application specialist to Lab Personal followed by issuance of training certificates to the trainees. 25. Warranty & System Calibration: At least 2 years onsite warranty with one year AMC should also be quoted along with the offer. Supplier must have Kolkata based service facility with factory trained engineer. System calibration should be done once in every year with issue of calibration certificate as per ISO: 17025 during the warranty period.26. Performance certificate: Quoted equipment should be latest with proof of installation Report/Performance certificate from at least 3 users of reputed organizations is to be attached along with technical bid.27. EMD: Rs. 30,000 (Rupees thirty thousand only) in the form of bank draft in favour of ‘Bidhan Chandra Krishi Viswavidyalaya’ payable at Kalyani (IFSC: SBIN0001082). Scan copy of the draft must be uploaded as the supporting document during submission of e-tender. Without EMD quotations will not be considered for technical or financial comparison. However, bidders are requested not to send the original draft during tendering process.\n BI01010001010000000000000515BI0100001118 1 Nos
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail