Directorate Of Technical Education-DTE has published Supply Of Control Of Electrical Machines Lab Equipments. Submission Date for this Tender is 15-02-2021. Gear Product Tenders in CHIDHAMBARAM Tamil Nadu. Bidders can get complete Tender details and download the document.
Name of Work: Supply of CONTROL OF ELECTRICAL MACHINES LAB EQUIPMENTS | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supply of CONTROL OF ELECTRICAL MACHINES LAB EQUIPMENTS (FOR TECHNICAL SPECIFICATIONS REFER NIT) | |||
2 | 1.01 | Automatic Rotor Resistance Starter using PLC With Starting resistance of 20ohm\n Start and Stop Switches\n 4 nos. of 3 phase 16A Contactors\n Inputs to PLC and outputs from PLC\n Provision to wire external resistances in the rotor circuit \n Institute has to provide 9 external resistances to be connected in the rotor circuit Provision to wire control and power wiring\n Screen Printed Board, powder coated MS tube stands, back cover\n Detailed instruction manual\n | Item1 | 1 | Nos |
3 | 1.02 | Transformer Oil Test Kit\n Input voltage 230V, Single Phase\n Output 0-60KV\n Test cup, Transparent hood, interlocking switch\n HT On switch starting at zero voltage\n Tripping Current: 2.5mm gap – 10/20mA\n Sample Transformer Oil\n | Item2 | 1 | Nos |
4 | 1.03 | Acidity Test Kit | Item3 | 1 | Nos |
5 | 1.04 | Lift working Model using PLC\n 3 floors (Ground plus two floors) sheet metal model\n Floor request switches and Floor sensing switches – 6 inputs to PLC\n Cabin – stepper motor with controller/geared DC motor with forward and reverse control \n Proper termination to wire inputs and outputs to PLC\n | Item4 | 1 | Nos |
6 | 1.05 | Water Level working Model using PLC\n Level sensors as input to the PLC\n Water tap as output from the PLC\n Water Pump motor control using outputs of the PLC\n Water Tank with sump and Overhead tank model\n 2 Levels sensor switches and 12 V Pump\n 24 V Solenoid valve to drain water, 12 V and 24V Power Supply\n Foot valve arrangement to take the water from the sump \n | Item5 | 1 | Nos |
7 | 1.06 | Conveyor working Model using PLC\n Sloped conveyor with shawl sheet metal model\n Proximity sensor to sense the shawl - input to PLC\n Start, Stop Push switches and FWD / REV toggle switch, Buzzer output to give alarm \n Conveyor belt with geared DC Motor drive\n | Item6 | 1 | Nos |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy